• 제목/요약/키워드: Architecture Configuration

검색결과 673건 처리시간 0.028초

Signaling and Control Procedures Using Generalized MPLS Protocol for IP over an Optical Network

  • Um, Tai-Won;Choi, Jun-Kyun;Kim, Young-Ae;Lee, Hyeong-Ho;Jung, Hae-Won;Jong, Sang-Gug
    • ETRI Journal
    • /
    • 제24권2호
    • /
    • pp.69-81
    • /
    • 2002
  • This paper reviews the existing research activities on signaling and control procedures for IP over optical networks. We focus on the IP-centric signaling and control architecture based on the generalized multi-protocol label switching (GMPLS) protocol and analyze various scenarios and technical issues for deploying the IP over an optical network. We analyze the signaling and operations and administration and maintenance requirements for integrating an IP network and an optical network in order to cope with the high bandwidth and poor resource granularity of the optical network, including the optical cross-connect system. On the basis of network architecture and a reference configuration model, we investigate the GMPLS-based control architecture and interconnection model appropriate for controlling IP bandwidth and optical lambda resources. The signaling and control procedure based on GMPLS on optical user-network interface and network-network interface are comparatively investigated to provide the optical lightpath. We also study protection and restoration procedures to protect link failure when it applies to generalized MPLS signaling.

  • PDF

Advances in White OLED Tandem Architecture for Next Generation AMOLED Displays

  • Hatwar, T.K.;Spindler, J.P.;Vargas, J.R.;Helber, M.;Klubek, K.;Begley, W.;Itoh, M.;Hamer, J.;VanSlyke, S.A.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.231-234
    • /
    • 2007
  • Advances in white OLED tandem architecture are discussed.With these structures, stable and low-power full color AMOLED displays can be fabricated that are anticipated to be suitable for large area applications such as TVs. With a tandem architecture, efficient (24 cd/A) OLED structures with exceptional stability (${\sim}100,000\;h$ at $1000\;cd/m^2$) are described. In addition, excellent color gamut (>100% NTSC) can be attained by incorporating advanced color filters into the AMOLED backplane in a typical bottom-emitting configuration.

  • PDF

자동 기계학습(AutoML) 기술 동향 (Recent Research & Development Trends in Automated Machine Learning)

  • 문용혁;신익희;이용주;민옥기
    • 전자통신동향분석
    • /
    • 제34권4호
    • /
    • pp.32-42
    • /
    • 2019
  • The performance of machine learning algorithms significantly depends on how a configuration of hyperparameters is identified and how a neural network architecture is designed. However, this requires expert knowledge of relevant task domains and a prohibitive computation time. To optimize these two processes using minimal effort, many studies have investigated automated machine learning in recent years. This paper reviews the conventional random, grid, and Bayesian methods for hyperparameter optimization (HPO) and addresses its recent approaches, which speeds up the identification of the best set of hyperparameters. We further investigate existing neural architecture search (NAS) techniques based on evolutionary algorithms, reinforcement learning, and gradient derivatives and analyze their theoretical characteristics and performance results. Moreover, future research directions and challenges in HPO and NAS are described.

Identifiability of Ludwik's law parameters depending on the sample geometry via inverse identification procedure

  • Zaplatic, Andrija;Tomicevic, Zvonimir;Cakmak, Damjan;Hild, Francois
    • Coupled systems mechanics
    • /
    • 제11권2호
    • /
    • pp.133-149
    • /
    • 2022
  • The accurate prediction of elastoplasticity under prescribed workloads is essential in the optimization of engineering structures. Mechanical experiments are carried out with the goal of obtaining reliable sets of material parameters for a chosen constitutive law via inverse identification. In this work, two sample geometries made of high strength steel plates were evaluated to determine the optimal configuration for the identification of Ludwik's nonlinear isotropic hardening law. Finite element model updating(FEMU) was used to calibrate the material parameters. FEMU computes the parameter changes based on the Hessian matrix, and the sensitivity fields that report changes of computed fields with respect to material parameter changes. A sensitivity analysis was performed to determine the influence of the sample geometry on parameter identifiability. It was concluded that the sample with thinned gauge region with a large curvature radius provided more reliable material parameters.

Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

  • Oh, Hyoung Seok;Shin, Hyeongyeop;Ju, Youngkyu;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권3호
    • /
    • pp.311-325
    • /
    • 2022
  • For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

성 이냐시오 채플에 나타난 현상학적 건축특성에 관한 연구 (A Study on the Phenomenological Characteristics of the St. Ignatius Chapel by Steven Holl)

  • 김준성;정태용
    • 한국실내디자인학회논문집
    • /
    • 제21권4호
    • /
    • pp.12-20
    • /
    • 2012
  • The aim of this study is to review phenomenological characteristics in Steven Holl's architecture through his design of St. Ignatius Chapel at Seattle University. To obtain this purpose, an analytical frame based on Holl's theory of phenomenological architecture is suggested to have a systematic study for St. Ignatius chapel. This chapel can be a good example of phenomenological architecture in that it is based on the concept of 'A Gathering of Different Lights' related to phenomenology and considered perception including multi sensory (as well as vision) as primary factors from site and program interpretation to spatial configuration. Unprecedented exterior of St. Ignatius chapel reflected on characteristics and function of rooms to magnify user's spatial experiences through inducing natural light and spatial effect. Holl used various openings and screen for natural light with colors to invoke religious inspiration. He also try to give spatial depth and multi foci for experiencing space through various ceiling forms. These phenomenological features originated in client's strong will as well as appropriateness of the function of facility's religious experiences through building to the purpose of phenomenological architecture.

  • PDF

보안 시스템의 자동 관리를 위한 보안 네트워크 관리 구조의 설계 및 성능 분석 (Design and Performance Analysis of Security Network Management Architecture for Auto-managing Security Systems)

  • 안개일
    • 한국통신학회논문지
    • /
    • 제30권8B호
    • /
    • pp.525-534
    • /
    • 2005
  • 본 논문에서는 정책 기반의 네트워크 관리 구조를 확장하여, 보안 네트워크의 구성의 자동화를 지원할 수 있는 보안 네트워크 관리 구조와 방법을 제안한다. 제안하는 구조 및 방법은 보안 관리 서버가 보안 시스템의 역할과 능력 그리고 보안 정책의 역할과 시간 정보를 기반으로 하여 보안 시스템이 필요로 하는 최적의 보안 정책을 자동 결정하고 보안 정책 룰을 가장 효과적이고 효율적으로 실행할 수 있는 보안 시스템을 자동 결정할 수 있게 한다 본 논문에서는 기존의 네트워크 시스템과 보안 시스템을 통합 제어할 수 있는 SNMP 프로토콜기반의 보안 네트워크 토폴러지 맵 자동 생성기도 제안한다. 본 논문에서 제안된 구조와 방법의 우수성을 보여주기 위하여 공격에 대한 자동 대응 기능을 시뮬레이션하고 그 성능을 평가한다.

Identification of progressive collapse pushover based on a kinetic energy criterion

  • Menchel, K.;Massart, T.J.;Bouillard, Ph.
    • Structural Engineering and Mechanics
    • /
    • 제39권3호
    • /
    • pp.427-447
    • /
    • 2011
  • The progressive collapse phenomenon is generally regarded as dynamic. Due to the impracticality of nonlinear dynamic computations for practitioners, an interest arises for the development of equivalent static pushover procedures. The present paper proposes a methodology to identify such a procedure for sudden column removals, using energetic evaluations to determine the pushover loads to apply. In a dynamic context, equality between the cumulated external and internal works indicates a vanishing kinetic energy. If such a state is reached, the structure is sometimes assumed able to withstand the column removal. Approximations of these works can be estimated using a static computation, leading to an estimate of the displacements at the zero kinetic energy configuration. In comparison with other available procedures based on such criteria, the present contribution identifies loading patterns to associate with the zero-kinetic energy criterion to avoid a single-degree-of-freedom idealisation. A parametric study over a family of regular steel structures of varying sizes uses non-linear dynamic computations to assess the proposed pushover loading pattern for the cases of central and lateral ground floor column failure. The identified quasi-static loading schemes are shown to allow detecting nearly all dynamically detected plastic hinges, so that the various beams are provided with sufficient resistance during the design process. A proper accuracy is obtained for the plastic rotations of the most plastified hinges almost independently of the design parameters (loads, geometry, robustness), indicating that the methodology could be extended to provide estimates of the required ductility for the beams, columns, and beam-column connections.

다양한 수평비정형성을 갖는 도시구조물의 등가정적해석에 의한 내진성능분석 (Seismic Performance of Urban Structures with Various Horizontal Irregularities using Equivalent Static Analysis)

  • 최기룡;최민호;김성일
    • 중소기업융합학회논문지
    • /
    • 제6권1호
    • /
    • pp.25-32
    • /
    • 2016
  • 현대건축의 변화와 발달에 따라 건축물의 형상은 더욱 다양해지고 비정형화 되어가는 추세에 있다. 그러나, 건축물의 내진성능에 대한 고려를 배재한 가운데 진행된 건축형상의 변화에 대한 시도는 지진 발생 시 심각한 구조적 피해를 초래할 수 있다. 따라서, 건축형상에 대한 합리적 분류를 기반으로, 보다 상세하고 발전된 내진설계 전략을 수립하는 것은 매우 중요한 기술적 대비로서의 의미가 있다. 본 연구에서는 다양한 요각모서리 형상을 갖는 수평비정형 구조물들에 대한 내진성능을 비교 검토하고자 하였다. 최대한 단순화 된 비교가 가능하도록 정형구조물 및 서로 다른 네 가지 수평비정형 구조물 모델을 선정하여 구조적 특징을 통일시키고, 각 비정형성에 대한 등가정적해석을 수행하였다. 해석 결과, 상대적으로 탁월한 정형구조물의 내진성능을 확인할 수 있었고, 수평비정형성을 반영하는 요각모서리 부분에서 상대적 응력집중 및 구조적손상이 확인되었다. 본 연구 결과를 통해 미래의 도시건축물 내진설계를 위한 내진성능 기반의 가이드라인을 제시할 수 있을 것으로 판단된다.

수의과대학 반려동물병원의 프로그램 및 공간구성에 관한 연구 - 최근 10년 내에 준공 된 국내 수의과대학 동물병원 분석을 중심으로 (A Study on the Medical Program and Space Configuration for Veterinary Medical Teaching Hospital - Focused on the Analysis of Veterinary Medical Teaching Hospital built in the last ten years of Korea)

  • 김도현
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제23권3호
    • /
    • pp.71-80
    • /
    • 2017
  • Purpose: At the moment prevention and treatment of animal related diseases is becoming a social concern as the demand for animal increases. Furthermore, The design of the veterinary medical teaching hospital are even more complex because they have to accommodate medical program for animal and education and research program for students. However, there are a few experience and useful guidelines for the planning of the veterinary medical teaching hospital. So it is not easy for the regional hub universities to work out the proper plan for the construction of the veterinary medical teaching hospital for their own. This study has been started in order to provide basic informations for the planning of Korean veterinary medical teaching hospital. Methods: Interview to veterinarian, intern and employee of the veterinary medical teaching hospital and Field surveys to veterinary medical teaching hospital in Korea have been conducted for the data collection. The drawings of three universities of veterinary medical teaching hospital have been analysed and diagramed. Results: The result of this study can be summarized into three points. The first one is that the veterinary medical teaching hospital spaces are divided into five areas (ambulatory care, central medical care, hospitalization, education and research, operations and support) and each area is divided independently and connected properly. The second one is that the veterinary medical teaching hospital differs from hospital in the detailed space plan in the sense that the animal is a patient. The third one is that each hospital has different operating practices and programs according to local conditions Implications: It is meaningful as a basic source of veterinary medical teaching hospital design in the future.