• Title/Summary/Keyword: Arc Detection

Search Result 198, Processing Time 0.027 seconds

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Kim, Eung-Sik;Kim, Hong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2433-2440
    • /
    • 2009
  • Whole system and network for supply of electric power and electricity safety are essential element. Electricity safety technology need rating for product and research about certification as product development that is done electric power u-IT cotton flannel mixed with development of u-IT, u-City base technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power u-IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication module about function of product for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in electric leakage, high voltage, Arc, fire detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

A Study on Performance Evaluation and Security Methods of u-IT Electrical Safety Integrated Management System's Module (u-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dae-Woo;Kim, Eung-Sik;Choi, Choung-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.6
    • /
    • pp.1447-1452
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. u-City in order to prevent the disaster of u-IT Power Equipment Performance Module and the security for the safety of the u-City is necessary. In this paper, the power unit of u-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation methods and security methods will be studied. u-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as u-IT integrated management system for electrical safety and strengthen the security, safety and security with a u-City will contribute to the construction and operation.

A Study on Performance Evaluation and Security Measures of U-IT Electrical Safety Integrated Management System's Module (U-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dea-Woo;Choi, Choung-Moon;Kim, Eung-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.307-310
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. U-City in order to prevent the disaster of U-IT Power Equipment Performance Module and the security for the safety of the U-City is necessary. In this paper, the power unit of U-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation and security measures will be studied. U-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as U-IT integrated management system for electrical safety and strengthen the security, safety and security with a U-City will contribute to the construction and operation.

  • PDF

A Study of Evaluation Certification on Electronic Power u-IT Convergence Equipment (전력 u-IT 융복합화 기기의 평가와 인증 연구)

  • Yi, Jeong-Hoon;Park, Dea-Woo;Bae, Suk-Myong;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.499-502
    • /
    • 2009
  • Supply of electric power and electricity safety for whole system and network are essential element. Electricity safety technology need rating for product and research about certification as product development that is done cotton flannel mixed with development of u-IT technology consists. Study on serve to develop electricity safety integration supervision system to apply product to u-City electric power appliance and cotton flannel mixed of u-IT appliance, Connection badness sensing instrument made device built-in electric power IT cotton flannel mixed in outlet that is used most in electric power appliance terminal. Using sensor on ZigBee, RFID performance estimation of communication and module for remote safety check of electricity safety integration supervision system. A performance experiment and estimation in PD, Arc detection diagnosis system and certification KS, electricity safety about product that get fitness finding.

  • PDF

A method for automatically generating a route consisting of line segments and arcs for autonomous vehicle driving test (자율이동체의 주행 시험을 위한 선분과 원호로 이루어진 경로 자동 생성 방법)

  • Se-Hyoung Cho
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Path driving tests are necessary for the development of self-driving cars or robots. These tests are being conducted in simulation as well as real environments. In particular, for development using reinforcement learning and deep learning, development through simulators is also being carried out when data of various environments are needed. To this end, it is necessary to utilize not only manually designed paths but also various randomly and automatically designed paths. This test site design can be used for actual construction and manufacturing. In this paper, we introduce a method for randomly generating a driving test path consisting of a combination of arcs and segments. This consists of a method of determining whether there is a collision by obtaining the distance between an arc and a line segment, and an algorithm that deletes part of the path and recreates an appropriate path if it is impossible to continue the path.

LH-FAS v2: Head Pose Estimation-Based Lightweight Face Anti-Spoofing (LH-FAS v2: 머리 자세 추정 기반 경량 얼굴 위조 방지 기술)

  • Hyeon-Beom Heo;Hye-Ri Yang;Sung-Uk Jung;Kyung-Jae Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.1
    • /
    • pp.309-316
    • /
    • 2024
  • Facial recognition technology is widely used in various fields but faces challenges due to its vulnerability to fraudulent activities such as photo spoofing. Extensive research has been conducted to overcome this challenge. Most of them, however, require the use of specialized equipment like multi-modal cameras or operation in high-performance environments. In this paper, we introduce LH-FAS v2 (: Lightweight Head-pose-based Face Anti-Spoofing v2), a system designed to operate on a commercial webcam without any specialized equipment, to address the issue of facial recognition spoofing. LH-FAS v2 utilizes FSA-Net for head pose estimation and ArcFace for facial recognition, effectively assessing changes in head pose and verifying facial identity. We developed the VD4PS dataset, incorporating photo spoofing scenarios to evaluate the model's performance. The experimental results show the model's balanced accuracy and speed, indicating that head pose estimation-based facial anti-spoofing technology can be effectively used to counteract photo spoofing.

Welder's Exposure to Airborne Hexavalent Chromium and Nickel during Arc Welding in a Shipyard (모 조선업체 아크 용접 작업자의 공기중 6가 크롬 및 니켈 노출에 관한 연구)

  • Shin, Yong Chul;Yi, Gwang Yong;Lee, Na Roo;Oh, Se Min;Kang, Seong Kyu;Moon, Young Hahn;Lee, Ki Ra
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.2
    • /
    • pp.209-223
    • /
    • 1998
  • The aim of this study was to evaluate welders' exposure to hexavalent chromium (Cr(VI)) and nickel (Ni) during welding operations in a Korean shipyard. The airborne Cr(VI) and Ni concentrations were measured during metal inert gas (MIG) welding on mild and stainless steel, and manual metal arc (MMA) welding on mild steel. The geometric mean (GM) of Cr(VI) concentrations inside the welding helmet during MIG welding on mild steel were $0.0018mg/m^3$ inside a ship section, and $0.0015-0.0026mg/m^3$ at the welding shops. All of the personal breathing zone air samples were below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value ($TLV^{(R)}$) of $0.01mg/m^3$. Conversely, eighty-eight percent(21 of 24) of the personal breathing zone air samples exceeded the National Institute for Occupational Safety and Health (NIOSH) recommended exposure limit of $0.001mg/m^3$. Ni was not detected on 20 of 23 air samples collected during MIG welding on mild steel. The three Ni samples above the limit of detection ranged from 0.015 to $0.044mg/m^3$. The GM of Cr(VI) concentrations during MMA welding on mild steel were $0.0013mg/m^3$, but Ni was not detected in the air samples during this operation. It is assumed that the airborne Cr(VI) and Ni during mild steel welding were derived from the base metals which contained about 0.03% Cr and 0.03% Ni. The GM of airborne total Cr, Cr(VI) and Ni concentrations during MIG welding on stainless steel were 4.02, 0.13 and $0.86mg/m^3$, respectively, and the levels of Cr(VI) and Ni were above the ACGIH-$TLV^{(R)}$. Cr(VI) comprised about 35.5% of the total chromium(Cr) from MIG welding on mild steel, and about 8.4% of total Cr from MIG welding on stainless steel. The ratios of Cr(VI) to total Cr were significantly different among welding shops. It was concluded that welders were exposed to high levels of Cr(VI) and Ni during welding on stainless steel, and were exposed to low levels of Cr(VI) even during welding on mild steel.

  • PDF

A COMPARISON OF FLUORESCENCE EFFECT OF VARIOUS LIGHT SOURCES IN EARLY ENAMEL CARIES (초기 우식 병소에서 광원에 따른 형광효과 비교)

  • Jeon, Jeong-Hoon;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.611-619
    • /
    • 2005
  • The aim of this study was to apply the quantitative light-induced fluorescence(QLF) and use of fluorescein-enhanced QLF method for quantitative assessment of early enamel demineralization in vitro, comparing effectiveness of light sources : argon laser, halogen lamp, light emitting diode (LED) and plasma arc lamp. Sixty extracted teeth were used, prepared by gentle pumicing and coating in an acid-resistant nail-varnish, except for an exposure to a demineralizing solution. Teeth were removed at regular intervals (24, 48 and 72hrs), air-dried and QLF image were taken. Mineral loss, as measured by difference of optical density, was recorded. For dyeenhanced QLF a 0.075% sodium fluorescein dye was applied after QLF examination and mineral loss was recorded. The following result were obtained : 1. Comparing with mean difference of optical density, plasma arc lamp was higher than other light sources in all group (p<0.05). 2. Comparing each group with mean difference of optical density, there was significant different using plasma are lamp and halogen lamp. 3. For use of dye-enhanced QLF, comparing with mean difference of optical density, plasma arc lamp were higher than other light sources in all group(p<0.05). 4. With this model dye-enhanced QLF compared with QLF in optical density, dye-enhanced QLF was higher than QLF in optical density. From the results presented in this paper, it was concluded that plasma light source was more effective compared with other light source for the detection and the quantification of early enamel caries.

  • PDF

Iron Oxide-Carbon Nanotube Composite for NH3 Detection (산화철-탄소나노튜브 나노복합체의 암모니아 가스센서 응용)

  • Lee, Hyundong;Kim, Dahye;Ko, DaAe;Kim, Dojin;Kim, Hyojin
    • Korean Journal of Materials Research
    • /
    • v.26 no.4
    • /
    • pp.187-193
    • /
    • 2016
  • Fabrication of iron oxide/carbon nanotube composite structures for detection of ammonia gas at room temperature is reported. The iron oxide/carbon nanotube composite structures are fabricated by in situ co-arc-discharge method using a graphite source with varying numbers of iron wires inserted. The composite structures reveal higher response signals at room temperature than at high temperatures. As the number of iron wires inserted increased, the volume of carbon nanotubes and iron nanoparticles produced increased. The oxidation condition of the composite structures varied the carbon nanotube/iron oxide ratio in the structure and, consequently, the resistance of the structures and, finally, the ammonia gas sensing performance. The highest sensor performance was realized with $500^{\circ}C/2h$ oxidation heat-treatment condition, in which most of the carbon nanotubes were removed from the composite and iron oxide played the main role of ammonia sensing. The response signal level was 62% at room temperature. We also found that UV irradiation enhances the sensing response with reduced recovery time.

A Study of Corona Discharge in Polymer Insulators by Artificial UV Radiation (인위적인 자외선 조사량에 따른 폴리머애자에서의 코로나 방전 특성)

  • Kim, Y.S.;Choi, M.I.;Kim, C.M.;Bang, S.B.;Shong, K.M.;Kwag, D.S.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.643-648
    • /
    • 2013
  • In this study, degradation was observed by irradiating UV rays to the polymer insulators which have been widely used in outdoor electric power facilities. For an indoor accelerated UV test, 0.55 w/m2 of UV rays were applied using a xenon-arc method. A UV detection system with 65 ${\phi}mm$ in diameter, 100 mm in length and 1.0 of brightness (F/#) has been designed. Even though efflorescence on the surface of polymer insulators wasn't observed according to the accelerated UV test. UV rays were detected at around 50% and 40% of insulation breakdown in EPDM and silicone-type insulators respectively. As degradation continued because of an indoor accelerated UV test, breakdown voltage with which UV rays can be detected in an early stage decreased as well. A silicone polymer insulator would be severer than EPDM polymer insulator in terms of surface degradation because of UV strength against $V_m/V_{BD}$ was high in silicone polymer insulators. UV strength in silicone-type insulators increased at 1,000 $kJ/m^2$ because contact angle at the intial stage sharply decreased to from $113^{\circ}$ to $92.1^{\circ}$.