• Title/Summary/Keyword: Approach Detection System

Search Result 893, Processing Time 0.026 seconds

Convergence of Remote Sensing and Digital Geospatial Information for Monitoring Unmeasured Reservoirs (미계측 저수지 수체 모니터링을 위한 원격탐사 및 디지털 공간정보 융합)

  • Hee-Jin Lee;Chanyang Sur;Jeongho Cho;Won-Ho Nam
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_4
    • /
    • pp.1135-1144
    • /
    • 2023
  • Many agricultural reservoirs in South Korea, constructed before 1970, have become aging facilities. The majority of small-scale reservoirs lack measurement systems to ascertain basic specifications and water levels, classifying them as unmeasured reservoirs. Furthermore, continuous sedimentation within the reservoirs and industrial development-induced water quality deterioration lead to reduced water supply capacity and changes in reservoir morphology. This study utilized Light Detection And Ranging (LiDAR) sensors, which provide elevation information and allow for the characterization of surface features, to construct high-resolution Digital Surface Model (DSM) and Digital Elevation Model (DEM) data of reservoir facilities. Additionally, bathymetric measurements based on multibeam echosounders were conducted to propose an updated approach for determining reservoir capacity. Drone-based LiDAR was employed to generate DSM and DEM data with a spatial resolution of 50 cm, enabling the display of elevations of hydraulic structures, such as embankments, spillways, and intake channels. Furthermore, using drone-based hyperspectral imagery, Normalized Difference Vegetation Index (NDVI) and Normalized Difference Water Index (NDWI) were calculated to detect water bodies and verify differences from existing reservoir boundaries. The constructed high-resolution DEM data were integrated with bathymetric measurements to create underwater contour maps, which were used to generate a Triangulated Irregular Network (TIN). The TIN was utilized to calculate the inundation area and volume of the reservoir, yielding results highly consistent with basic specifications. Considering areas that were not surveyed due to underwater vegetation, it is anticipated that this data will be valuable for future updates of reservoir capacity information.

The Detection and Diagnosis Methods of Infectious Viroids caused Plant Diseases (식물체에 감염성 질병을 유발하는 바이로이드 검출 및 진단 방법)

  • Lee, Se Hee;Kim, Yang-Hoon;Ahn, Ji-Young
    • Journal of Life Science
    • /
    • v.26 no.5
    • /
    • pp.620-631
    • /
    • 2016
  • Viroids are about 250-400 base pair of short single strand RNA fragments have been associated with economically important plant diseases. Due to the lack of protein expression capacity associated with replication, it is very difficult to diagnosis viroid diseases in serological methods. For detecting viroid at plants, molecular-based techniques such as agarose gel electrophoresis, polyacrylamide gel electrophoresis (PAGE), DNA-hybridization, blotting analysis and conventional RT-PCR are reliable. Real-time RT-PCR methods that grafted on RT-PCR methods with improved confirmation methods have been also utilized. However, they are still labor-intensive, time-consuming, and require personnel with expertise. Loop-mediated Isothermal Amplification (LAMP) method is a nucleic acid amplification method under the isothermal condition. The LAMP methodology has been reported to be simple, rapid, sensitive and field applicable in detecting a variety of pathogens. The results of LAMP method can be colorized by adding a visible material such as SYBR green I, Evagreen, Calcein, Berberine and Hydroxy naphthol blue (HNB) with simple equipment or naked eyes. The combination of LAMP method and nucleic pathogens, viroids, can be used to realize simple diagnosis platform for the genetic point-of care testing system. The aim at this review is to summary viroid-caused diseases and the simple visible approach for diagnosing viroids using Loop-mediated Isothermal Amplification (LAMP) method.

Acoustic Emission Monitoring of Incipient Failure in Journal Bearing Part II : Intervention of Foreign Particles in Lubrication (음향방출을 이용한 저어널 베어링의 조기파손감지(II) - 윤활유 이물질 혼입의 영향 및 감시 -)

  • Yoon, Dong-Jin;Kwon, Oh-Yang;Jung, Min-Hwa;Kim, Kyung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.122-131
    • /
    • 1994
  • Journal bearings in the rotating machineries are vulnerable to the contamination or the insufficient supply of lubricating oil, which is likely to be the cause of unexpected shutdown or malfunction of these systems. Various destructive and nondestructive testing methods had been used for the reduction of maintenance cost and the operational safety problems due to the accidents related to bearing damages. In this experimental approach, acoustic emission monitoring is employed to the detection of incipient failure caused by intervention of foreign particles most probable in the journal bearing systems. Experimental schedules for the intervention of foreign particles was composed to be more quantitative and systematic than last study in consideration of minimum oil film thickness and particle size. The experiment was conducted under such designed conditions as inserting alumina particles to the lubrication layer in the simulated journal bearing system. Several parameters such as AE rms level, waveform, AE energy distribution and other AE event parameters are used for analysis and characterization of damage source. The results showed that the history of damage was well correlated with the changes of AE rms level and the type of damage source signal can be verified using other informations such as waveform, distributions of AE parameters etc.

  • PDF

DEVELOPMENT OF AN AMPHIBIOUS ROBOT FOR VISUAL INSPECTION OF APR1400 NPP IRWST STRAINER ASSEMBLY

  • Jang, You Hyun;Kim, Jong Seog
    • Nuclear Engineering and Technology
    • /
    • v.46 no.3
    • /
    • pp.439-446
    • /
    • 2014
  • An amphibious inspection robot system (hereafter AIROS) is being developed to visually inspect the in-containment refueling storage water tank (hereafter IRWST) strainer in APR1400 instead of a human diver. Four IRWST strainers are located in the IRWST, which is filled with boric acid water. Each strainer has 108 sub-assembly strainer fin modules that should be inspected with the VT-3 method according to Reg. guide 1.82 and the operation manual. AIROS has 6 thrusters for submarine voyage and 4 legs for walking on the top of the strainer. An inverse kinematic algorithm was implemented in the robot controller for exact walking on the top of the IRWST strainer. The IRWST strainer has several top cross braces that are extruded on the top of the strainer, which can be obstacles of walking on the strainer, to maintain the frame of the strainer. Therefore, a robot leg should arrive at the position beside the top cross brace. For this reason, we used an image processing technique to find the top cross brace in the sole camera image. The sole camera image is processed to find the existence of the top cross brace using the cross edge detection algorithm in real time. A 5-DOF robot arm that has multiple camera modules for simultaneous inspection of both sides can penetrate narrow gaps. For intuitive presentation of inspection results and for management of inspection data, inspection images are stored in the control PC with camera angles and positions to synthesize and merge the images. The synthesized images are then mapped in a 3D CAD model of the IRWST strainer with the location information. An IRWST strainer mock-up was fabricated to teach the robot arm scanning and gaiting. It is important to arrive at the designated position for inserting the robot arm into all of the gaps. Exact position control without anchor under the water is not easy. Therefore, we designed the multi leg robot for the role of anchoring and positioning. Quadruped robot design of installing sole cameras was a new approach for the exact and stable position control on the IRWST strainer, unlike a traditional robot for underwater facility inspection. The developed robot will be practically used to enhance the efficiency and reliability of the inspection of nuclear power plant components.

The Evaluation of Potential Hepatotoxicity by Calcium Channel Blockers, Renin-Angiotensin System Blockade and Diuretics (칼슘채널차단제, 레닌-안지오텐신시스템 차단제, 이뇨제의 잠재적 간독성 평가)

  • Kim, Jae Yun;Lee, Ok Sang;Jung, Sun Hoi;Lee, Hye-Suk;Lee, Chang Ho;Kim, Sang Geon;Lim, Sung Cil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.4
    • /
    • pp.330-339
    • /
    • 2012
  • Background : Hypertension is treated with both lifestyle modification and pharmacotherapy. The Seventh Report of the Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure (JNC-7), published in 2003, provides a streamlined management approach to hypertension for the primary care physician. The JNC-7 is the gold standard also in Korea. According to the JNC-7, special therapeutic considerations are recommended for high-risk individuals with compelling indications. The presence of compelling indications in any given patient should be considered when selecting specific pharmacotherapy to treat hypertension. However, in patients with compelling indications, it is unknown that hepatotoxicity is caused by Calcium Channel Blocker (CCB), one of 1st anti-hypertensive drugs. Now, the CCB is the most used 1st anti-hypertensive drug in Korea Therefore, we evaluated the changes in blood liver function parameters (ALT, AST, Total bilirubin, serum albumin) for the study group. Methods : We randomly collected and retrospectively analyzed Electronic Medical Record data (n=28,788) of patients, and who took calcium channel blockers(non-dihydropyridines; diltiazem, verapamil, dihydropyridines; amlodipine, barnidipine, benidipine, clinidipine, efonidipine, felodipine, isradipine, lacidipine, lercanidipine, nicardipine, nifedipine, nimodipine), with having liver function tests (LFTs) from July 1st 2009 to June 30th 2010 at the Seoul National University Hospital in Korea. Control groups are two antihypertensive agents: RAS blockade (ARB; candesartan, irbesartan, losartan, olmesartan, telmisartan, valsartan, ACE-I; cilazapril, enalapril, fosinopril, imidapril, perindopril, ramipril) and, Diuretics (loop; furosemide, torsemide, thiazide; hydrochlorothiazide[HCTZ], indapamide). Patients not having LFT results at these three standard points of time(baseline, during, medication, and after finishing medication) were excluded. The collected data were analyzed by using the SPSS (Version12.0) and Microsoft Excel (Version2007). Results : 711 patients who were treated CCB (297), RAS blockade (232) or Diuretics (182) monotherapy were selected for the study. In selected patients, liver damage degree(changes of each LFTs value) was higher in diuretics group than other groups, followed by RAS blockade and CCB. In diuretics group's was loop-diuretics group was higher than thiazide-diuretics group. In CCB group, Nondihydropyridine-CCB's damage degree was higher than Dihydropyrine-CCB's that. Conclusions : Despite the limitations due to the retrospective study, among patients with abnormal LFTs, the use of CCBs led to a less liver damage than other 1st anti-hypertensive agents. It can be recommended CCBs as one of the initial treatments of hypertension in patients with liver disease.

Promoting Oral Cancer Awareness and Early Detection using a Mass Media Approach

  • Saleh, Amyza;Yang, Yi-Hsin;Ghani, Wan Maria Nabillah Wan Abd;Abdullah, Norlida;Doss, Jennifer Geraldine;Navonil, Roy;Rahman, Zainal Ariff Abdul;Ismail, Siti Mazlipah;Talib, Norain Abu;Zain, Rosnah Binti;Cheong, Sok Ching
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1217-1224
    • /
    • 2012
  • Background and Aim: Less than 50% of oral cancer cases are diagnosed at early stages of the disease and this is in part due to poor awareness and lack of knowledge on the signs and symptoms of oral cancer. This study sought to measure the baseline awareness of oral cancer in Malaysia and aimed to increase public awareness and knowledge of oral cancer using a mass media campaign. Methods: Baseline awareness and impact of the campaign was measured using self-administered questionnaires sent via email to individuals. The campaign was aired on two national television channels and the reach was monitored through an independent programme monitoring system. Results: 78.2% of respondents had heard of oral cancer, and this increased significantly after the campaign. However, the ability to recognize signs and symptoms remains unchanged. We found that the level of awareness differed between the distinct ethnic subgroups and the reach of the campaign was not uniform across all ethnicities. Conclusion: This substantial study to measure the oral cancer awareness in Malaysia provides important baseline data for the planning of public health policies. Despite encouraging evidence that a mass media campaign could increase the awareness of oral cancer, further research is required to address the acceptability, comprehensiveness and effectiveness. Furthermore, different campaign approaches may be required for specific ethnic groups in a multi-ethnic country such as Malaysia.

New Decision Rules for UWB Synchronization (UWB 동기화를 위한 새로운 결정 법칙들)

  • Chong, Da-Hae;Lee, Young-Yoon;Ahn, Sang-Ho;Lee, Eui-Hyoung;Yoo, Seung-Hwan;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.2C
    • /
    • pp.192-199
    • /
    • 2008
  • In ultra-wideband (UWB) systems, conventionally, the synchronization is to align time phases of a locally generated template and any of multipath components to within an allowable range. However, the synchronization with a low-power multipath component could incur significant performance degradation in receiver operation (e.g., detection) after the synchronization. On the other hand, the synchronization with a high-power multipath component can improve the performance in receiver operation after the synchronization. Generally, the first one among multipath components has the largest power. Thus, the synchronization with the first path component can make better performance than that with low-power component in receiver operation after the synchronization, Based on which, we first propose an optimal decision rule based on a maximum likelihood (ML) approach, and then, develope a simpler suboptimal decision rule for selecting the first path component. Simulation results show that the system has good demodulation performance, which uses new synchronization definition and the proposed decision rules have better performance than that of the conventional decision rule in UWB multipath channels. Between macroblocks in the previous and the current frame. On video samples with high motion and scene change cases, experimental results show that (1) the proposed algorithm adapts the encoded bitstream to limited channel capacity, while existing algorithms abruptly excess the limit bit rate; (2) the proposed algorithm improves picture quality with $0.4{\sim}0.9$dB in average.

Conceptual Design of Automatic Control Algorithm for VMSs (VMS 자동제어 알고리즘 설계)

  • 박은미
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.7
    • /
    • pp.177-183
    • /
    • 2002
  • Current state-of-the-art of VMS control is based upon simple knowledge-based inference engine with message set and each message's priority. And R&Ds of the VMS control are focused on the accurate detection and estimation of traffic condition of the subject roadways. However VMS display itself cannot achieve a desirable traffic allocation among alternative routes in the network In this context, VMS display strategy is the most crucial part in the VMS control. VMS itself has several limitations in its nature. It is generally known that VMS causes overreaction and concentration problems, which may be more serious in urban network than highway network because diversion should be more easily made in urban network. A feedback control algorithm is proposed in this paper to address the above-mentioned issues. It is generally true that feedback control approach requires low computational effort and is less sensitive to models inaccuracy and disturbance uncertainties. Major features of the proposed algorithm are as follows: Firstly, a regulator is designed to attain system optimal traffic allocation among alternative routes for each VMS in the network. Secondly, strategic messages should be prepared to realize the desirable traffic allocation, that is, output of the above regulator. VMS display strategy module is designed in this context. To evaluate Probable control benefit and to detect logical errors of the Proposed feedback algorithm, a offline simulation test is performed using real network in Daejon, Korea.

Detection of Freshwater Jellyfish (Craspedacusta sowerbii Lankester, 1880) by Biofilm eDNA in Miho River Watershed (미호강 수계 생물막의 환경유전자를 이용한 담수해파리 (Craspedacusta sowerbii Lankester, 1880) 유전자 탐색)

  • Keonhee Kim ;Hyeonjin Cho ;Jeong-Hui Kim;Yun-mo Yang;Hyunji Ju;Hyun-Gi Jeong
    • Korean Journal of Ecology and Environment
    • /
    • v.56 no.3
    • /
    • pp.250-258
    • /
    • 2023
  • Freshwater jellyfish, a type of jellyfish exclusively found in freshwater, has a limited number of species but is found globally. However, their ecology and causes of occurrence are largely unknown. Therefore, understanding the distribution of polyps, which produce the larvae of freshwater jellyfish, can provide important data for comprehending their ecology. This study aims to explore the COI gene of freshwater jellyfish using environmental DNA from the microbial film in the Miho River system. Among the 12 survey points in the Miho River watershed, genetic material of freshwater jellyfish was detected in 8 points, mainly located upstream near reservoirs. These genetic materials were identified as genes of the well-known freshwater jellyfish species, Craspedacusta sowerbii. Notably, the C. sowerbii genes found in the Miho River watershed survey points were closely related to a species previously discovered in Italy. Consequently, utilizing environmental DNA to explore the genetic traces of freshwater jellyfish enables rapid screening of areas with a high likelihood of freshwater jellyfish occurrence. This approach is deemed to provide crucial information for understanding the distribution and ecology of freshwater jellyfish in Korea.

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.2
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF