• Title/Summary/Keyword: Application Procedures

Search Result 1,208, Processing Time 0.031 seconds

In Vitro Efficacies of Complex of Cedrol and Three Peptides, and Wrinkle Improvements and Lips Volumization effects of Applied Formulations (Cedrol 및 펩타이드 3 종 Complex 의 In Vitro 효능 및 적용 제형의 입술 주름 개선 및 Volumization 효과에 대한 연구)

  • Seongsu Kang;Seung-Hyun Jun;Jinyong Lee;Myoung Jin An;Nae Gyu Kang
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.4
    • /
    • pp.365-373
    • /
    • 2023
  • Since the lips are a representative facial part that can express human attraction, aesthetic interest in them has always existed in human history. However, as lips age, they tend to form wrinkles, become thinner, and lose their volume. To counteract this phenomenon, medical procedures such as fillers or fat transplantation have been suggested. In this study, we verified that the one of main effective material complex of L G H&H L IPCERIN®, combination of cedrol, a sesquiterpene found in cedarwood, and three peptides (acetyl hexapeptide-8, acetyl tetrapeptide-9, and desamidocollagen) could ameliorate the photo-aging and reduce the wrinkles through in vitro experiments. The possibility of improving collagen and elastin expression in skin fibroblasts and reducing MMP expression under photoaging conditions was verified. In addition, it was confirmed that the amount of fat tissue in the lips can be increased by promoting adipose stem cell differentiation and increasing the amount of fat produced in the in vitro adipose stem cell differentiation experiment. Two weeks of human application tests confirmed that a combination of cedrol and peptides can improve the wrinkles, texture, elasticity, and volume of the lips. This study verified that the combination of cedrol and three peptides can be used as effective cosmetic materials to decrease the various signs of aging in the lips.

Development and Case Study of Unmanned Aerial Vehicles (UAVs) for Weather Modification Experiments (기상조절 실험용 드론의 설계·제작과 활용에 관한 연구)

  • Hae-Jung Koo;Miloslav Belorid;Hyun Jun Hwang;Min-Hoo Kim;Bu-Yo Kim;Joo Wan Cha;Yong Hee Lee;Jeongeun Baek;Jae-Won Jung;Seong-Kyu Seo
    • Atmosphere
    • /
    • v.34 no.1
    • /
    • pp.35-53
    • /
    • 2024
  • Under the leadership of the National Institute of Meteorological Sciences (NIMS), the first domestic autonomous flight-type weather modification experimental drone for fog and lower-level cloud seeding was developed in 2021. This drone is designed based on a multi-copter configuration with a maximum takeoff weight of approximately 25 kg, enabling the installation of up to four burning flares for seeding materials and facilitating weather observations (temperature, pressure, humidity, and wind) as well as aerosol (PM10, PM2.5, and PM1.0) particle measurements. This research aims to introduce the construction of the drone and its recent applications over the past two years, providing insights into the experimental procedures, effectiveness verification, and improvement directions of the weather modification drone-based rain enhancement. In particular, partial confirmation of the experimental effects was obtained through the fog dissipation experiment on December 10, 2021, and the lower-level cloud seeding case study on October 5, 2022. To enhance the scope and rainfall amount of weather modification experiments using drones, various technological approaches, including adjustments to experimental altitude, seeding lines, seeding amount, and verification methods are necessary. Through this research, we aim to propose the development direction for weather modification drone technology, which will serve as foundational technology for practical application of domestic rain enhancement technology.

Application of Multiple Linear Regression Analysis and Tree-Based Machine Learning Techniques for Cutter Life Index(CLI) Prediction (커터수명지수 예측을 위한 다중선형회귀분석과 트리 기반 머신러닝 기법 적용)

  • Ju-Pyo Hong;Tae Young Ko
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.594-609
    • /
    • 2023
  • TBM (Tunnel Boring Machine) method is gaining popularity in urban and underwater tunneling projects due to its ability to ensure excavation face stability and minimize environmental impact. Among the prominent models for predicting disc cutter life, the NTNU model uses the Cutter Life Index(CLI) as a key parameter, but the complexity of testing procedures and rarity of equipment make measurement challenging. In this study, CLI was predicted using multiple linear regression analysis and tree-based machine learning techniques, utilizing rock properties. Through literature review, a database including rock uniaxial compressive strength, Brazilian tensile strength, equivalent quartz content, and Cerchar abrasivity index was built, and derived variables were added. The multiple linear regression analysis selected input variables based on statistical significance and multicollinearity, while the machine learning prediction model chose variables based on their importance. Dividing the data into 80% for training and 20% for testing, a comparative analysis of the predictive performance was conducted, and XGBoost was identified as the optimal model. The validity of the multiple linear regression and XGBoost models derived in this study was confirmed by comparing their predictive performance with prior research.

A Design of Authentication Mechanism for Secure Communication in Smart Factory Environments (스마트 팩토리 환경에서 안전한 통신을 위한 인증 메커니즘 설계)

  • Joong-oh Park
    • Journal of Industrial Convergence
    • /
    • v.22 no.4
    • /
    • pp.1-9
    • /
    • 2024
  • Smart factories represent production facilities where cutting-edge information and communication technologies are fused with manufacturing processes, reflecting rapid advancements and changes in the global manufacturing sector. They capitalize on the integration of robotics and automation, the Internet of Things (IoT), and the convergence of artificial intelligence technologies to maximize production efficiency in various manufacturing environments. However, the smart factory environment is prone to security threats and vulnerabilities due to various attack techniques. When security threats occur in smart factories, they can lead to financial losses, damage to corporate reputation, and even human casualties, necessitating an appropriate security response. Therefore, this paper proposes a security authentication mechanism for safe communication in the smart factory environment. The components of the proposed authentication mechanism include smart devices, an internal operation management system, an authentication system, and a cloud storage server. The smart device registration process, authentication procedure, and the detailed design of anomaly detection and update procedures were meticulously developed. And the safety of the proposed authentication mechanism was analyzed, and through performance analysis with existing authentication mechanisms, we confirmed an efficiency improvement of approximately 8%. Additionally, this paper presents directions for future research on lightweight protocols and security strategies for the application of the proposed technology, aiming to enhance security.

Workflow Procedures and Applications in BIM-based Design for Safety (DfS) (BIM 기반 설계안전성검토의 업무 절차와 활용 방안에 관한 연구)

  • Jaewoong Hwang;Heetaek Yoon;Junhyun Bae;Youngkon Park
    • Land and Housing Review
    • /
    • v.15 no.2
    • /
    • pp.125-137
    • /
    • 2024
  • A conventional Design for Safety (DfS), introduced to eliminate potential hazards in the design phase proactively, has encountered persistent challenges, such as perfunctory risk assessments and hazard identifications based on 2D drawings and inefficient workflow processes. This study proposes a BIM-based approach to Design for Safety (DfS) to address the limitations of conventional methods, aiming to enhance efficiency and achieve practical safety management benefits. The proposed workflow process for BIM-based DfS has been refined and validated for on-site applicability through various case studies, including risk assessments during the design phase and field applications for safety management activities during the construction phase. Specifically, the critical process of risk assessment within the DfS methodology has also been transitioned to a BIM-based approach. This BIM-based risk assessment process has been evaluated through case studies, encompassing safety reviews for structural design, construction equipment operation, and construction methodology with sequence in design projects. Additionally, the proposed BIM-based DfS has demonstrated exceptional on-site applicability and efficiency, as validated by the application of a BIM deliverable embedded in DfS information for CDE-based daily activity briefing, VR-based safety training, AR-based mitigation measures inspections, and other safety management activities in the construction phase.

A Study on the Improvement of the TRA Framework for Complex Weapon Systems from the System Integration Perspective (시스템 통합 관점의 복합 무기체계 기술성숙도 평가 프레임워크 개선에 관한 연구)

  • Jiin Koo;Sukjae Jeong
    • Journal of The Korean Institute of Defense Technology
    • /
    • v.5 no.2
    • /
    • pp.23-30
    • /
    • 2023
  • TRA(Technology Readiness Assessment) quantitatively assesses the current level of domestic technology and is used as a key tool for determining the possibility of domestic R&D and risk management. However, since the current TRA utilizes hardware-oriented TRL(Technology Readiness Level), it is suitable for independent assessment of each technologies, but has limitations in evaluation from a system integration perspective. In addition, the checklist-based assessment is highly likely to involve subjective evaluation. This study proposes an enhanced TRA framework by redefining TRA procedures and criteria from the systems integration perspective of system engineering. We focused on developing a framework that overcomes the limitations of the current TRL/TRA and enables easier and more intuitive assessment. The proposed framework distinguishes between TE(Technology Element) and CTE(Critical Technology Element) in terms of HW, SW and interface and redefines TRL. TRA is performed according to the TRL redefined from the above three points of view, and the lowest evaluation value is used as system maturity level in consideration of risk management. The proposed CTE selection method minimizes the intervention of the evaluator by utilizing the quantitative goal of the key ROC(Required Operational Capability), development difficulty, and application of COTS(Common Off The Shelf) technology. The effectiveness of this framework was confirmed through a case study of the TSS(Target Surveillance System). It is hoped that starting with this study, research at the framework level will be activated and contribute to the improvement of the TRA system.

  • PDF

A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs (성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구)

  • Yoon, Byung-Soo;Choi, Byung-Ho;Lee, Won-You;Kim, Kyoung-Nam;Shim, Hyung-Bo;Park, Jin-Hyung
    • The korean journal of orthodontics
    • /
    • v.31 no.5 s.88
    • /
    • pp.517-523
    • /
    • 2001
  • Titanium miniscrews we being used increasingly as an anchorage for tooth movement, because they ate easy to place and to remove, increase the number of sites available, give minimum strain to patients regarding surgical procedures, and offer uneventful healing alter removal. The use of titanium miniscrews as an orthodontic anchorage has been reported in clinical case reports, but clinicians have experienced screw loosening when using such screws.' To our knowledge, there are no published reports evaluating the stability of miniscrews. Information about the length of miniscrews used in relation to the location is of some importance, as stability will vary depending on bone duality The purpose of this study was to evaluate a variety of Lengths of miniscrews (dimeter: 2mm) which were inserted in maxilla or mandible and to demonstrate in a dog model which miniscrew provides fundamental stability in the jaws. 10 mm long miniscrews in the maxilla and 8mm long: miniscrews in the mandible showed no clinical mobility and retained their position throughout an 8 weeks force (200g) application. The mucosal condition around the screws was healthy in cases in which miniserews were inserted in the alveolar bone between the roots and the head of the screws emerged into the attached gingiva. When the force application was terminated, radiographic analysis revealed neither rent resorption not periodontal pathology around the miniscrews that remained stable during the entire treatment period. This study suggests that if titanium miniscrews with adequate length are properly used depending on the location, they provide sufficient stability for orthodontic anchorage.

  • PDF

Clinical Application of 11C-Acetate Positron Emission Tomography-Computed Tomography (PET-CT) in Patients of Urinary System Cancer (비뇨기암 환자에서 11C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용)

  • Nam-Koong, Hyuk;Ham, Joon chul;Kim, Sang kyoo;Choi, Yong hoon;Lim, Han sang;Kim, Jae sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.9-13
    • /
    • 2016
  • Purpose PET-CT examinations using $^{18}F-FDG$ to treat urinary system cancer are limited in terms of anatomical structure and excretion route of $^{18}F-FDG$. But one of the ongoing examinations utilizing $^{11}C-Acetate$ can compensate for such defects. We would like to introduce a clinical application of $^{11}C-Acetate$ PET-CT in urinary cancer patients. Materials and Methods We conducted a clinical survey of 22 patients diagnosed with urinary cancer at our hospital, 10 prostate cancer patients, 10 renal cell carcinoma patients, and 2 bladder cancer patients. All patients were performed $^{18}F-FDG$ PET-CT examinations, $^{11}C-Acetate$ examinations were performed after two weeks on average. The equipment used to D-710 PET-CT in GE Company and we performed PET-CT procedures 15 minutes after injecting $^{11}C-Acetate$, and a medical doctor from the department of nuclear medicine appraised and compared images between $^{18}F-FDG$ and $^{11}C-Acetate$. Results According to our survey, prostate cancer patients generally had lower uptake of $^{18}F-FDG$ than other cancer patients did. In 2 out of 10 prostate cancer patients, metastasized cancer showed greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. In renal cell carcinoma cases, 8 out of 10 patients displayed evidently greater uptake in $^{11}C-Acetate$ than $^{18}F-FDG$. We excluded bladder cancer cases in this study because uptake of $^{18}F-FDG$ in the bladder was too hot, the number of patients was insufficient, and the cases did not meet criteria such as the use of diuretics. Conclusion It is too premature to draw solid conclusions from the survey, since it involved only a small number of participants. However, there are a number of studies conducted abroad that prove the effectiveness of the $^{11}C-Acetate$ PET-CT examinations in treating urinary system cancer, and this study is still ongoing at our hospital. If the tests were to be conducted on a larger number of participants, this study could lead to numerous other potential research topics, such as the correlation between Prostatic specific antigen (PSA) values and $^{11}C-Acetate$ PET-CT, Gleason sum values from biopsy before surgery, Specificity, sensitivity, positive predictive value (PPV), negative predictive value (NPV) between $^{18}F-FDG$ PET-CT examinations and $^{11}C-Acetate$ PET-CT examinations in other urinary system cancers.

  • PDF

$^{99m}Tc$ Labeling Kit Preparation and Characteristics of Anti-NCA-95 Monoclonal Antibody (항 NCA-95 단일클론항체의 $^{99m}Tc$표지 키트 제조 및 특성 연구)

  • Hong, Mee-Kyoung;Jeong, Jae-Min;Chung, June-Key;Choi, Seok-Rye;Kim, Chae-Kyun;Lee, Yong-Jin;Lee, Dong-Soo;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.541-547
    • /
    • 1996
  • The previous monoclonal antibody labeling method for bone marrow immunoscintigrapy was complicated and laborious for clinical application. Also it showed a relatively low labeling efficiency. To improve this procedure, we compared several direct labeling methods of $^{99m}Tc$. 1) The labeling efficiency in the method using gluconate as a transchelator was low (40-70%), but immunoscintigraphy using this radiotracer produced a clear image. 2) To improve labeling efficiency, ${\beta}$-mercaptoethanol was removed after reduction. The labeling efficiency was improved up to 70-80%, but the radioactivity of the blood pool was high. 3) The higest labeling efficiency (>90%) and best quality images could be obtained by using MDP as a transchelating agent. It did not require additional procedures for separation of labeled antibodies. The immunoreactivity of this antibody was 60%. Residual MDP which can be taken up by the bone could be removed by PD-10 column. The reduced antibodies were stable with a high labeling efficiency (>90%) for up to 47 days by deep freezing. We concluded that the improved procedure for $^{99m}Tc$ labeling of anti-NCA-95 monoclonal antibody using MDP as a transchelating agent will be a simple and useful method for clinical application.

  • PDF

SHEAR BOND STRENGTH AND MICROLEAKAGE OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF CONTAMINATED SURFACE AFTER APPLYING A BONDING AGENT (접착제 도포후 오염된 표면의 처리방법에 따른 복합레진의 전단결합강도와 미세누출)

  • Park, Joo-Sik;Lee, Suck-Jong;Moon, Joo-Hoon;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.647-656
    • /
    • 1999
  • The purpose of this study was to investigate the shear bond strength and marginal microleakage of composite to enamel and dentin according to different treatment methods when the applied bonding agent was contaminated by artificial saliva. For the shear bond strength test, the buccal and occlusal surfaces of one hundred twenty molar teeth were ground to expose enamel(n=60) and dentin surfaces(n=60). The specimens were randomly assigned into control and 5 experimental groups with 10 samples in each group. In control group, a bonding system(Scotchbond$^{TM}$ Multi-Purpose plus) and a composite resin(Z-100$^{TM}$) was bonded on the specimens according to manufacture's directions. Experimental groups were subdivided into 5 groups. After polymerization of an adhesive, they were contaminated with at artificial saliva on enamel and dentin surfaces: Experimental group 1 ; artificial saliva was dried with compressed air. Experimental group 2 ; artificial saliva was rinsed with air-water spray and dried. Experimental group 3 ; artificial saliva was rinsed, dried and applied an adhesive. Experimental group 4 ; artificial saliva was rinsed, dried, and then etched using phosphoric acid followed by an adhesive. Experimental group 5, artificial saliva was rinsed, dried, and then etched with phosphoric acid followed by consecutive application of both a primer and an adhesive. Composite resin(Z-100$^{TM}$) was bonded on saliva-treated enamel and dentin surfaces. The shear bond strengths were measured by universal testing machine(AGS-1000 4D, Shimaduzu Co. Japan) with a crosshead speed of 5mm/minute under 50kg load cell. Failure modes of fracture sites were examined under stereomicroscope. The data were analyzed by one-way ANOVA and Tukey's test. For the marginal microleakage test, Class V cavities were prepared on the buccal surfaces of sixty molars. The specimens were divided into control and experimental groups. Cavities in experimental group were contaminated with artificial saliva and those surfaces in each experimental groups received the same treatments as for the shear test. Cavities were filled with Z-100. Specimens were immersed in 0.5% basic fuchsin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from the one specimen. Marginal microleakages of enamel and dentin were scored under streomicroscope and averaged from four sections. The data were analyzed by Kruskal-Wallis test and Fisher's LSD. The results of this study were as follows. 1. The shear bond strength to enamel showed lower value in experimental group 1(13.20${\pm}$2.94MPa) and experimental group 2(13.20${\pm}$2.94MPa) than in control(20.03${\pm}$4.47MPa), experimental group 4(20.96${\pm}$4.25MPa) and experimental group 5(21.25${\pm}$4.48MPa) (p<0.05). 2. The shear bond strength to dentin showed lower value in experimental group 1(9.35${\pm}$4.11MPa) and experimental group 2(9.83${\pm}$4.11MPa) than in control group(17.86${\pm}$4.03MPa), experimental group 4(15.04${\pm}$3.22MPa) and experimental group 5(14.33${\pm}$3.00MPa) (p<0.05). 3. Both on enamel and dentin surfaces, experimental group 1 and 2 showed many adhesive failures, but control and experimental group 3, 4 and 5 showed mixed and cohesive failures. 4. Enamel marginal microleakage was the highest in experimental group 1 and there was a significant difference in comparison with other groups (p<0.05). 5. Dentin marginal microleakages of experimental group 1 and 2 were higher than those of other groups (p<0.05). This result suggests that treatment methods, re-etching with 35% phosphoric acid followed by re-application of adhesive or repeating all adhesive procedures, will produce good effect on both shear bond strength and microleakage of composite to enamel and dentin if the polymerized bonding agent was contaminated by saliva.

  • PDF