• Title/Summary/Keyword: Apparent Power

Search Result 273, Processing Time 0.025 seconds

Power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal

  • Cao, Xiaoling;Yan, Liangjun
    • Geosystem Engineering
    • /
    • v.21 no.5
    • /
    • pp.251-261
    • /
    • 2018
  • With the urbanization in recent years, the power line interference noise in electromagnetic signal is increasing day by day, and has gradually become an unavoidable component of noises in magnetotelluric signal detection. Therefore, a kind of power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal is put forward in this paper. The method first uses wavelet decomposition to change single-channel signal into multi-channel signal, and then takes advantage of blind source separation principle of independent component analysis to eliminate power line interference noise. There is no need to choose the layer number of wavelet decomposition and the wavelet base of wavelet decomposition according to the observed signal. On the treatment effect, it is better than the previous power line interference removal method based on independent component analysis. Through the de-noising processing to actual magnetotelluric measuring data, it is shown that this method makes both the apparent resistivity curve near 50 Hz and the phase curve near 50 Hz become smoother and steadier than before processing, i.e., it effectively eliminates the power line interference noise.

Expected Future Market Volume of HTS Equipment in South Korea

  • Yoon, Jae-Young;Lee, Seung-Ryul;Yang, B.;Lee, Seung-Yeup;Won, Young-Jin
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.129-133
    • /
    • 2011
  • This paper shows the entire future market volume of the HTS power industry, one of main smart grid equipment, in the case of the final market penetration ratio reaching 100% in the domestic market (South Korea). In this paper, the market penetration ratio is determined using the judgment method, with the market penetration S-curve induced using the Delphi method and the Product Life Cycle from 2011 (supposed launching year, not realistic physical year), to 2050 (expected final target year). This paper analyzes the HTS market penetration ratio of each stage, apparent innovation, early adapters, and the early/late majority and laggard stage, using the S-curve, thus calculating the total future market volume of HTS equipment in the positive sense. Finally, this paper estimates the quantitative analysis results for the HTS4-items (cable, FCL, transformer, rotation machine) of each year within the domestic market.

The Monitoring system for the measurement of the operating performance of a LIM which can be drive a new vehicle (신교통 차량 추진용 리니어모터의 운전성능측정 및 모니터링시스템 구축)

  • Jang, S.M.;Park, Y.T.;Seo, J.H.;Jeong, S.S.;Lee, S.H.;Ham, S.Y.;Park, C.I.;Jeong, R.G.;Lee, J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.74-76
    • /
    • 1997
  • This paper describes the implementation for electrical quanties and mechanical quanties monitoring system of the LIM driven by a inverter. The monitoring system can be display the characteristics of it's quanties, such as voltage, current, power, power factor, frequency, apparent power, thrust, speed, position, normal force, on the real time.

  • PDF

Cooling Geometry Dependent Operation Properties in a Diode End-Pumped Monolithic Yb:YAG Laser

  • Moon, Hee-Jong;Lim, Changhwan
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.5
    • /
    • pp.593-600
    • /
    • 2016
  • Operation properties, such as output power, beam radius, and crystal temperature rise were investigated in a diode-pumped edge-cooled monolithic Yb:YAG laser with ~ 4 W pumping level. The output power showed saturation behavior because of severe temperature rise and poor spatial overlapping between pump beam and lasing mode. Face cooling geometry by using a sapphire plate was also investigated. No apparent saturation behavior in output power was observed due to the reduced temperature rise, which could be attributed to efficient heat removal through the crystal-sapphire interface.

Evaluating Predictive Ability of Classification Models with Ordered Multiple Categories

  • Oong-Hyun Sung
    • Communications for Statistical Applications and Methods
    • /
    • v.6 no.2
    • /
    • pp.383-395
    • /
    • 1999
  • This study is concerned with the evaluation of predictive ability of classification models with ordered multiple categories. If categories can be ordered or ranked the spread of misclassification should be considered to evaluate the performance of the classification models using loss rate since the apparent error rate can not measure the spread of misclassification. Since loss rate is known to underestimate the true loss rate the bootstrap method were used to estimate the true loss rate. thus this study suggests the method to evaluate the predictive power of the classification models using loss rate and the bootstrap estimate of the true loss rate.

  • PDF

A Study for Operation Zone of Distance Relay on Transmission Line Connected UPFC (UPFC가 설치된 선로에서 거리계전기의 동작특성에 관한 연구)

  • Jung, Chang-Ho;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.130-132
    • /
    • 2001
  • This paper discusses the operation zone of distance relay on transmission line connected unified power flow controller(UPFC). Depending on operating conditions of UPFC, the trip characteristics of distance relay is influenced by the prefault conditions. In this paper, apparent impedance of distance relay influenced by the UPFC control of distance is calculated.

  • PDF

SURVEY OF ENERGY MANAGEMENT SYSTEMS FOR GENERATION AND TRASMISSION SYSTEMS THROUGHOUT THE WORLD (전세계(全世界) 발송전계통(發送電系統)의 에너지관리(管理)시스템조사(調査))

  • Yoon, Kap-Koo;Yoo, Hong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1983.07a
    • /
    • pp.177-179
    • /
    • 1983
  • This paper provides a primer for the Energy Control Center designers and a comprehensive overview for utility management personnel that desire an understanding of the Energy Management System for a Generation-Transmission System. Any errors or apparent misrepresentation of facts that may appear in the list are entirely unintentional. I would greatly appreciate being informed of any such omissions and errors.

  • PDF

Characteristic of Power Consumption for Paddle Impeller in Various Agitated Vessels (여러 가지 교반조에서 Paddle 임펠러의 교반소요동력 특성)

  • Lee, Young Sei;Kato, Yoshihito
    • Applied Chemistry for Engineering
    • /
    • v.16 no.5
    • /
    • pp.698-704
    • /
    • 2005
  • Power consumption for paddle impeller in spherical and cylindrical agitated vessel was measured over a wide range of Reynolds number from laminar to turbulent flow regions. The power correlation was obtained for both spherical and cylindrical vessels, where the apparent diameter of the spherical vessel was equal to the diameter of the cylindrical vessel (height equal to its diameter and had the same volume as the spherical vessel). The power consumption well correlated with the experimental results of Nagata, et al. and Hixson-Baum. Also the critical Reynolds numbers was directly related to the transition coefficient $C_{tr}$ characterizing the transition from a laminar to a turbulent flow region in the correlation proposed here.

Performance Verification and Improvement of UHF Sensor for the Increasement of the Partial Discharge Detection Reliability (부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1461-1466
    • /
    • 2014
  • GIS(Gas Insulated Switchgear) is important power apparatus which have strong dielectric strength, supply electric power and is a part of the power system. Most substation type is configured as GIS. Recently, because of continuous increasement of GIS demand resulted from high quality & big capacity of electric power, the necessity of the preventive & diagnosis system is being expanded gradually. GIS partial discharge occurred on the UHF band is detected effectively by the method to IEC 60270 that recommend to be able to detect the apparent minimum discharge, 5 pC. Additionally, the UHF sensor should be installed to detect PD signal if Partial discharge signal, 5 pC occur in every part of GIS. Currently PD diagnosis system applying UHF sensor for GIS with various voltage level like 154 kV, 345 kV, 765 kV have been operated. And it is necessary to measure and analyze insulation breakdown phenomenon of inside GIS exactly. In this paper, we proposed Fat-dipole patch UHF sensor that is developed and more sensitive, excellent wide-range characteristic than the exising UHF sensor. And we performed KERI (Korea Electrotechnology Research Institute) reference test, which showed the excellent result for the all tests.

A Characteristic Study on the Power Factor Correction Application for Induction Motor (유도전동기에 대한 역률 보상설비의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.25-31
    • /
    • 2008
  • The field of induction motor is magnetized and demagnetized for each reversal of the current. This field component of the motor accounts for most of the reactive component of inductive load. Reactive power needs to sustain the electromagnetic field required for the induction motor to operate. Power factor of induction motor is usually low and power factor correction needs. Power factor becomes low by the effect of the reduction operation of load capacity. In most cases, Capacitor capacity for the power factor correction should be complied with the recommendation by the motor capacity. But Capacitor value for power factor correction can't change during the normal operation. In this paper, we analyzed characteristics of power and power factor changing by load fluctuation of low-voltage small size induction motor and show that lower power factor correction's parameter of existing recommendation should be revised by new value.