• Title/Summary/Keyword: Apparatus design

Search Result 571, Processing Time 0.026 seconds

Investigation Into the Development Of Automatic VLM-ST (VLM-STA) Process and Its Apparatus (완전자동화된 단속적 재료 공급식 가변적층 쾌속조형공정 밀 장치 개발에 관한 연구)

  • 양동열;안동규;이상호;김효찬;박승교
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.4
    • /
    • pp.109-119
    • /
    • 2004
  • Rapid prototyping (RP) technologies have been widely used to reduce the lead-time and development cost of new products. $VLM-_{ST}$ process has been developed to overcome the currently developed RP technologies such as a large building time, a high building cost, an additional post-processing and a large apparatus cost. $VLM-_{ST}$ process requires an additional human interaction due to the manual stacking and bonding. Hence, building time, building cost and the part quality are dependent on the skill of labor. A novel RP process, fully automated $VLM-_{ST}$ process ($VLM-_{ST}$), has been developed to improve building efficiency of the process and the human dependency of the part. The objective of this work is to propose a $VLM-_{ST}$ process and to develop an apparatus for implementation of the process. $VLM-_{ST}$ process and its apparatus have various technical novelties such as two step cutting using a rotating table, an automatic stacking method using two pilot holes and two reference shapes, a concept of automatic unit shape layer (AUSL), and an automatic bonding using the bonding roller and building magazine. In order to examine the efficiency and the applicability of the proposed process, various three-dimensional shapes, such as a piston, a human head shape and a human bust shape, were fabricated on the apparatus.

Comparative study of sediment erosion on alternative designs of Francis runner blade

  • Rajkarnikar, Bidhan;Neopane, Hari P.;Thapa, Biraj S.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.3
    • /
    • pp.183-192
    • /
    • 2015
  • The aim of this study was comparative analysis of sediment-induced erosion on optimized design and traditional design of Francis runner blade. The analysis was conducted through laboratory experiments in a test rig called Rotating Disc Apparatus. The results showed that the extent of erosion was significantly less in the optimized design when compared based on the material loss. It was observed that the optimized design could reduce sediment erosion by about 14.4% if it was used in place of the reference design for entire duration of the experiment. Based on the observations and results obtained, it has been concluded that the optimization of hydraulic design of blade profile of Francis runner can significantly reduce the effect of sediment-induced erosion.

The Design Evaluation of Cutting Chip Collecting Apparatus to Manufacture Aircraft Components (항공기 기체 가공용 대용량 절삭칩 회수 장치의 설계 평가)

  • Kim K. Y.;Kim D. S.;Kang J. H.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.6
    • /
    • pp.110-116
    • /
    • 2005
  • A single-piece-machined-part has superior characteristics to an assembly of several pieces of part especially for aircraft components. It is necessary to develop high efficient 'multi-head router machine' for machining a large size single-piece-part on a large scale. In this type machine, many cutting chips are generated. These chips should be removed automatically f3r productivity and part precision. In this study, the design evaluation of the cutting chip collecting apparatus for 'multi-head router machine' was complemented using performance test and finite element analysis.

A Study on Design of Multi-Winding Transformer for Poly Silicon Production using Heat Pipe (히트파이프를 이용한 폴리실리콘 제조용 다중권선 변압기 설계에 관한 연구)

  • Lee, Chun-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.11
    • /
    • pp.1626-1630
    • /
    • 2015
  • This paper reflected the Temperature test value and compare the Computational Fluid Dynamic analysis value on particular characteristics of the multi-winding transformer's cooling apparatus equipped by heat pipe with excellent heat transfer ability on design Particularly if you look at multi-winding transformers that supply high-quality Direct current power to silicon production apparatus, heat generation due to high current supply is excessive thus, an innovative cooling apparatus is required in particular for reduced size transformer.

Development of Evaluation Checklist for Personal Office Furniture and Apparatus and Fact-Finding Survey

  • Park, Hee Sok;Jeong, Byung Yong;Jung, Myung-Chul
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.167-177
    • /
    • 2015
  • Objective: The objective of this research is to develop evaluation checklist for personal office furniture and apparatus to shape comfortable and efficient worksite for workers' welfare improvement, productivity enhancement and labor force preservation, and to identify office work environment by applying the checklist. Background: Because most office workers work using computers in a sitting posture, the ratio of office workers among total musculoskeletal disorders patients is forecast to increase. In this regard, an effort to prevent and manage such musculoskeletal disorders is required. Method: This research developed evaluation checklist for personal office furniture and apparatus by examining 25 domestic and international ergonomic literature and anthropometric data. This research carried out a fact-finding survey targeting the A Office and B Office of one public agency using the checklist. Results: Although, the checklist items on desks, chairs, computers and other goods conformed to the checklist standards, the following items did not conformed: desk height adjustment, seat board depth adjustment, lumbar support depth, foot rest, wrist rest, mouse tray, headset, speaker phone and Bluetooth. Conclusion: The evaluation checklist for personal office furniture and apparatus and fact-finding survey results are considered to be used as basic data for office work environment and workers' welfare improvement. Application: The information drawn from this research can be helpful to manufacturers' design and manufacture of ergonomic furniture and apparatus.

Development of an Apparatus for Removing Magnetic Sludge by Permanent Magnets Set up in the Condenser of the Power Plant (영구자석을 이용한 복수기 집수정 내부 자성이물질 제거장치 개발)

  • Bae, Jun-Ho;Kim, Moon-Saeng;Hwang, Beom-Cheol;Kim, Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.938-948
    • /
    • 2009
  • In this paper, permanent magnets were used to remove magnetic sludge in the condenser of the power plant. To obtain the flow characteristics and magnetic information that are needed for determining a proper design of the magnetics sludge removal apparatus, numerical simulations were performed through the use of two commercial codes, ANSYS Workbench-Emag and CFX. Experiments were also performed on various kinds and sizes of magnets to obtain the magnetic information through a gauss meter. By analyzing the results of simulations and experiments, the minimum magnetic force that is able to remove the any size of the magnetic sludge in the condenser was calculated, and the design of the removal apparatus was confirmed. The test model which was confirmed by simulations and experiments was made. After testing, the test results were compared with those of numerical simulations and have good agreements.

Design of a composite diagnostic DC test apparatus for high voltage power cable (고압전력케이블 현장진단시험용 종합 직류시험설비의 검토)

  • Ryoo, Hee-Suk;Kang, Dong-Sik;Sim, Jong-Tae;Lee, Ho-Jin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2326-2328
    • /
    • 1999
  • Developments of effective and economic diagnostic apparatus for industrial plastic insulated high voltage power cables are in discontented condition still. Some report told that DC high voltage was damaged plastic insulation of a partially aged power cable to lead breakdown easily. But now, we have no alternative tools of DC diagnostic apparatus, and we try to reduce a possibility of hazard DC diagnosis. DC diagnostic apparatus still have many advantages to field cable engineer like low price, portability easy applications and sufficient data. Main hazard of DC diagnosis is excessive hight of applied voltage Recent developments for DC diagnosis use considerably low voltage. But new test methods need special measuring device and manipulator, like high input impedance voltmeter, low leakage current high voltage switches, etc. So that reason, new DC diagnostic devices are normally very expensive and have low efficiency, economically. We try to design a composite test device for 3$\sim$4 newly developed method, have economical benefit th industrial engineer.

  • PDF

Development and demonstration of an erosion-corrosion damage simulation apparatus (배관 침부식 손상 연속모사 장비 개발 및 실증)

  • Nam, Won Chang;Ryu, Kyung Ha;Kim, Jae Hyoung
    • Corrosion Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.179-184
    • /
    • 2013
  • Pipe wall thinning caused by erosion and corrosion can adversely affect the operation of aged nuclear power plants. Some injured workers owing to pipe rupture has been reported and power reduction caused by unexpected pipe damage has been occurred consistently. Therefore, it is important to develop erosion-corrosion damage prediction model and investigate its mechanisms. Especially, liquid droplet impingement erosion(LDIE) is regarded as the main issue of pipe wall thinning management. To investigate LDIE mechanism with corrosion environment, we developed erosion-corrosion damage simulation apparatus and its capability has been verified through the preliminary damage experiment of 6061-Al alloy. The apparatus design has been based on ASTM standard test method, G73-10, that use high-speed rotator and enable to simulate water hammering and droplet impingement. The preliminary test results showed mass loss of 3.2% in conditions of peripheral speed of 110m/s, droplet size of 1mm-diameter, and accumulated time of 3 hours. In this study, the apparatus design revealed feasibility of LDIE damage simulation and provided possibility of accelerated erosion-corrosion damage test by controlling water chemistry.

Study on the Thermal Properties of Electric Moxibustion Apparatus for Presenting Assessment Guideline in Korea (국내 평가 가이드라인 제시를 위한 전기식 온구기의 열특성에 관한 연구)

  • Yi, Seung-Ho;Kang, Jung-Won;Nam, Dong-Woo;Kim, Eun-Jung;Lee, Hye-Jung;Kim, Kap-Sung;Lee, Jae-Dong
    • Journal of Acupuncture Research
    • /
    • v.26 no.6
    • /
    • pp.31-39
    • /
    • 2009
  • Objectives : To characterize the thermal properties of several Korean electric moxibustion apparatus and to suggest methods for improving their quality for related industry as well as the welfare of Korean. Methods : We reviewed previous literatures on traditional moxibustion to find necessary factors for electric moxibustion apparatus. We measured the thermal characteristics of electric moxibustion apparatus commercially available by using an automatic temperature acquisition system in a controlled environment. Uniformity and heat loss of the apparatus were also analysed. We followed the user's manuals of apparatus provided by manufacturers. Results : Temperature control of all apparatus could not be achieved by automatic manners. Most of them were dependent on user's discretion. Maximum temperatures obtained were barely in the therapeutic temperature of $40-45^{\circ}C$. Unnecessary heating of moxibustion parts was detected. Chemicals from moxa were not properly delivered to the human skin. Conclusions : Temperature control of all apparatus needs to be improved in terms of temperature setting, retention time and maximum temperature. Design should be altered to utilize pharmacological effects from moxa to obtain its maximum efficacy. User's manuals should be revised for its clarity.

  • PDF

A 3 Dimensional Characteristic Analysis of SLIM by the 2-D Finite Element Method (2차원 유한요소법에 의한 SLIM의 3차원적 특성 해석)

  • Cho, Yun-Hyun;Kim, Yong-Joo;Shin, Pan-Seok;Kang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.37-42
    • /
    • 1990
  • In order to obtain optimal design criteria and operating parameters, a Single-sided Linear Induction Motor (SLIM) is analysed by using a 2-D finite element method with magnetic and current vector potential. In the analysing procedures, the governing equation is derived from Maxwell's equation combined with the magnetic vector potential. As a forcing term, 3-phase voltage source is employed using the Kirchhoff's voltage law in order to look into effects of the unbalanced 3-phase currents and air gap flux density. Also, 2ndary eddy current distribution, longitudinal end and transverse edge effects are in turns visualized by flux lines in 3 different analysing planes as functions of frequency and input power.

  • PDF