• Title/Summary/Keyword: Apartment noise

Search Result 365, Processing Time 0.026 seconds

Prediction of Floor Impact Sound by Measuring the Vibration Acceleration Level on the Interior Structures of Receiving Room in Apartment Buildings (수음실 내 구조체의 진동량 계측을 통한 바닥충격음레벨 예측)

  • 김명준;김흥식;김하근
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.1
    • /
    • pp.3-9
    • /
    • 2003
  • In an apartment building, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. To set the optimum design for sound insulation. it is nesessary to suggest the useful tools or technique that predict the floor impact sound. The purpose of this study is to investigate the applicability of the theory of sound radiation. We measured the vibration acceleration levels on the interior structures and predicted the sound pressure level of the room by using them. The result show that the predicted value, in general, were in good agreement with the measured values within 5∼10% in error rate.

A Study on the Acoustic Performance Indication Standards of Apartment Housing Performance Grade Indication System (공동주택 성능등급 표시제도 상의 음성능 표시기준 고찰)

  • Yang, Kwan-Seop;Kim, Kyoung-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1252-1255
    • /
    • 2006
  • The government has enforced Housing Performance Grade Indication System (Article 21, Paragraph 2 of Housing Act) starting January 2006 for the purpose of giving users in hope of toying an apartment opportunities to select housing based on personal preferences by providing information on housing performance at the time of tenant recruitment announcement as well as securing desirable environment (comfort) by encouraging construction companies to build housing of the indicated performance level. The acoustic performance indication items include three items such as floor impact isolation performance(light weight impact sound, heavy weight impact sound), bathroom noise and insulation performance of boundary walls between households. This paper explains the background, the basis of creation and evaluation method focused on the acoustic environment performance helping for the developer of technique and a staff in charge of construction business who cope with this system.

  • PDF

Vibration Characteristics of the Floor Structures Inserted with Damping Materials (제진재가 삽입된 바닥 구조의 진동특성에 대한 실험연구)

  • Jeon, Jin-Yong;Jeong, Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1036-1043
    • /
    • 2006
  • Damping materials for reducing heavy-weight floor impact noise in reinforced concrete structures were tested in apartment buildings. The effect of damping materials and an impact isolator were compared with an on-site experiment conducted in a high-rise apartment building. The loss factor of damping material analyzed more than 2 times than rubber to $1.5{\sim}2.3$, could know that Damping layer has excellent attenuation performance in side of vibration reduction. The results showed that the resonance frequency increased but vibration acceleration level decreased when the damping materials were used. The heavy-weight impact sound levels of the structure decreased substantially at 63 Hz, whereas the sound levels of the structure with the impact isolator increased.

Development and Evaluation for Improvement of the Sound Insulation of Balcony Window in Apartment (차음성능 향상을 위한 발코니 창호의 개발 및 평가)

  • Kim, Ha-Geun;Kim, Myung-Jun;Oh, Jin-Kyun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.5 s.98
    • /
    • pp.519-526
    • /
    • 2005
  • Recently, the interest on the comfortable dwelling environment is increasing and the effort to solve the problem of exterior noise was tried. The propose of this study is to suggest the design of balcony window in apartment and to evaluate the sound insulation of it. So, we designed five types of balcony window which were considered not only sound insulation but ventilation. The sound reduction index of window was evaluated by the measurement in mock-up room. The results showed that case 2 improved about 6 dB in the weighted apparent sound reduction index than case 1, and case 3 reduced about $39 \%$ in construction cost than case 4.

A Study on the Characteristics of the Floor Impact Noise and Vibration According to Structure Types of Apartment House (공동주택 구조 유형별 바닥진동 및 바닥충격음 특성)

  • Lee, Ku-Dong
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.35-39
    • /
    • 2009
  • Recently, the flat-plate structure is widely used because it has many advantages such as reduction of story height, long span etc than the RC rahmen structure. Furthermore, application of the flat-plate is on the increase because of flexible plan unlike wall structure. Long span have been at a disadvantage for vibration serviceability evaluation, however studies about vertical direction vibration of flat-plate structure has not been carried out. This study analysis the characteristics according to slab structure to make an experiment on vibration and floor impact noise for the flat-plate structure in construction performance laboratory in Kolon E&C R&D center, the flat-plate structure applied to the post-tension method, and the wall structure in apartment houses.

  • PDF

Development and Evaluation for Improvement of the Sound Insulation of Balcony window in Apartment (차음성능 향상을 위한 발코니 창호의 개발 및 평가)

  • Oh, Jin-Kyun;Kim, Ha-Geun;Kim, Myung-Jun;Kim, Yun-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.445-450
    • /
    • 2004
  • Recently, the interest on the comfortable dwelling environment is increasing and the effort to solve the problem of exterior noise was tried. The propose of this study is to suggest the design of balcony window in apartment and to evaluate the sound insulation of it. So, we designed five types of balcony window which were considered not only sound insulation but ventilation. The sound reduction index of window was evaluated by the measurement in mock-up room. The results showed that case 2 improved about 6dB in the weighted apparent sound reduction index than case 1, and case 3 reduced about 39% in construction cost than case 4.

  • PDF

Characteristics of Reducing the Water-drainage Noise of Toilet-bowl According to the Composition of Water Drainage Piping Materials of the Bathrooms of Apartment Housing (공동주택 욕실 배수배관 자재 구성에 따른 양변기 배수소음 저감 특성)

  • Jeong, A-Yeong;Kim, Kyoung-woo;Shin, Hye-kyung;Yang, Kwan-seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.114-120
    • /
    • 2017
  • Water supply and drainage noise in the bathroom is recognized as one of the main noises, along with the floor-impact sounds, in apartment housings. Recently, to solve such noise issues, a new construction method of installing the piping on the slab has been adopted. rather than the traditional method of penetrating the piping through the slab between the upper and the lower bathrooms. However, this new method has limitations due to high costs and constructional difficulties. Therefore, this study was conducted to develop noise reducing piping and elbows, where the noise can be reduced simply by replacing the existing pipings. The noise level was measured in a laboratory by installing the horizontal drainage piping (three types) and the elbows (three types) developed in this study. The results showed that the horizontal pipings reduced the noise level in LAmax by 0.3 dB(A)~1.0 dB(A), as compared to the existing pipings (VG2), indicating an insignificant noise reduction effect. The elbow reduced the noise level in LAmax by 5.5 dB(A) ~ 11.5 dB(A), as compared to the existing elbow (DRF elbow), with the result of reducing the noise level at all frequencies evenly. Consequently, it was shown that using the elbows is more effective in reducing the water-drainage noise from the toilet than using the horizontal pipings.

A Study on the Indoor Noise Limits of Apartment Houses from the Road Traffic Noise (도로교통소음에 대한 공동주택 내부소음 기준설정에 관한 연구)

  • Lee, Ju-Yeob;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1084-1091
    • /
    • 2005
  • The indoor noise limit for road traffic noises is needed to secure comfortable acoustical quality in apartment houses. To achieve this goal, psycho-acoustic experiments were carried out with road traffic noise sources modulated by the transmission loss characteristics of the external windows. Finally, a correlation analysis between noise rating index and subjective responses, and an analysis of satisfactory percentage of the dose-response curves varied with respondents was conducted. As a result of this study, followings are suggested. (1) On correlation between dose level and psycho-acoustical response, the initial level of negative feeling is located on $40.1\~40.6\;L_{eq}$ dB(A), (2) On the degree of satisfaction to road traffic noise. near $35\;\%$ point being same dissatisfaction degree is to be assumed $40\~41$ dB(A) of indoor noise level presented into three vocabulary. It is suggested to be reasonable level of 40 dB(A) on the indoor noise limits for intruding road traffic noise. and it is appropriate to be the 5 dB level difference between grades. The results of this study may be used to evaluate the acoustic threshold level for road traffic noise or as a basis for specifying the desired acoustic environment of dwellings.

Development and Verification of Prediction Model for Road Traffic Noise in the Apartment Complex (아파트단지에서 도로교통소음 예측식 개발 및 검증)

  • Lee, Nae-Hyun;Sun, Woo-Young;Cho, Il-Hyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.67-73
    • /
    • 2006
  • 10 sites in building development areas were selected and the noise level were measured by the apartment floors of apartment complex. With the fitted regression analysis, the distribution ratio($R^2$) and correction coefficient(r) was 25%(0.5) in the NIER('87) and 7.5%(0.274) in the NIER('99), respectively. The measured values of the noise level on the seventh floor of complex did not show a good agreement with the predicted noise level in the NIER('87, '99) formula. However, the developed formula demonstrated that the measured values were reasonably close to the predicted values, indicating the validity and adequacy of the predicted models with the fitted vs residual analysis in the 95% of confidence interval and 95% of predict interval. The results suggested that application of this development model obtained by the results according to the apartment floor can be improved in road traffic noise.