• Title/Summary/Keyword: Apartment Supply

Search Result 321, Processing Time 0.026 seconds

Preferences of Mixed Types in a Social Mix Apartment Community and It's Residents' Social Behavior - Focused on the first district in Eunpyeong New Town in Seoul - (사회적 혼합아파트 거주자의 혼합유형 선호특성과 사회적 행태 연구 -서울시 은평뉴타운을 대상으로-)

  • Lee, Hye-Jin;Lee, Yeun-Sook;Lee, Soo-Jin
    • KIEAE Journal
    • /
    • v.11 no.5
    • /
    • pp.69-77
    • /
    • 2011
  • In order to solve social exclusion and segregation phenomenon and to realize social integration, the necessity of social combination and consensus has been presented and existing conception about the public lease apartment confronts a turning point due to the diversification of apartment supply system. With this social background, Eunpyeong New Town Project implemented by Seoul Metropolitan Government is the first example that supplied diverse apartments for social integration. Survey was made upon the residents aged 20 and over and living in combination apartments, lease apartments and common apartments for private ownership in the Enpyeong New Town Apartment Complex in section 1 area, and the survey sheets filled up by the respondents were collected by personal visits or by using specified gathering spots. Summary of study results is as follows: Firstly, regarding the combination method, respondents preferred the irregular combination of lease apartment units and common apartment units in the same apartment building at the top, analyzing by survey groups marked that residents of common apartment with initial ownership responded not to choose combination apartment complex or combination apartment in future. Secondly, the living consciousness with neighbors revealed that respondents were generally satisfied without difference between the residents of lease apartment and common apartment. As the demand and policies for diverse lease apartments are increasing recently, Eunpyeong New Town Project aimed for positive social integration and consensus will be evaluated as model case for social combination apartment in future. And it is necessary to introduce the policies that consider the differences in consciousness and interest of the residents among the lease apartments and common apartments.

A Study on the Application Method of Cold & Hot Water Manifold System for Hot Water Supply System in Residential Buildings (주거건물의 급탕방식별 급수.급탕헤더시스템 적용방안에 관한 연구)

  • Cha, Min-Chul;Je, Sung-Ho;Seok, Ho-Tae
    • Journal of the Korean housing association
    • /
    • v.19 no.1
    • /
    • pp.79-88
    • /
    • 2008
  • Hot water is used by having a wash, dishes, taking tub and drinking water in residential buildings, and the use objective is to raise comfort of human body sense, washing and sterilization effect and so on. Cold & hot water supply system is understanded simpler than HVAC systems relatively, so it is true that pace of performance improvement is slower than other systems for plan and technical development. In this study, the performance evaluations are conducted under the condition of composition ratio by 1:1 for cold & hot water supply manifold system using functionally complex valves such as constant flow regulating valve and 3-way mixing valve in the area of $105.6m^2$ apartment which consist of the largest part of the whole apartment. Also, flow rate related to simultaneous use of faucets and change of hot water temperature are compared with the existing method.

A Study on the Indoor Airflow Pattern by Changing the Location of Mechanical Terminal Unit (실내 급.배기구 위치변화에 따른 실 공기유동에 관한 연구)

  • Choi, Jeong-Min;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.3
    • /
    • pp.193-200
    • /
    • 2009
  • The ventilation system of apartments can be divided by supply and exhaust fan, supply fan and exhaust free and supply free and exhaust fan. Recently, the individual ventilation system and central ventilation system which is combined cooling system with duct system are applied to apartment ventilation system. The airflow pattern is affected by location of supply unit and exhaust unit in indoor. This study is to investigate the proper distance between supply unit and exhaust unit using CFD. As a result of this study, the proper distance between supply unit and exhaust unit could be suggested at the interval of 3 m in supply and exhaust fan system and 2.5 m in supply fan and exhaust free.

A Study on the Determinants of Apartment Price during COVID-19 Pandemic Using Dynamic Panel Model: Focusing on the Large-scale Apartment Complex of More than 3,000 Households in Seoul (동적패널모형을 활용한 코로나19 팬데믹 기간 아파트가격 결정요인 연구: 서울특별시 3000세대 이상 대규모 아파트 단지를 중심으로)

  • Jung-A, Park;Jong-Jin, Kim
    • Land and Housing Review
    • /
    • v.14 no.1
    • /
    • pp.33-46
    • /
    • 2023
  • This study investigated price factors for large apartment complexes in Seoul during the COVID-19 pandemic and compared Gangnam and non-Gangnam areas, which have been recognized as heterogeneous markets. We find that the change in apartment prices in large-scale complexes did not significantly affect the individual characteristics of apartments, unlike previous studies, but was affected by macroeconomic variables such as interest rates and money. On the other hand, considering the units of the interest rate and total monetary volume variables, the effects of two variables on the apartment sales price is significantly high. In addition, the Gangnam area model analysis shows that apartment prices are greatly affected by interest rates and currency volume, and, the non-Gangnam area model analysis shows that apartment prices are greatly affected by interest rates and currency volume, but the degrees are different from the Gangnam area model. Overall, our study shows that interest rates and money supply were the main factors of apartment price changes, but apartment prices in non-Gangnam areas are more sensitive to changes in interest rates and money supply.

Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home (제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

Analysis of Microclimate in Apartment Complex by Age (시대별 아파트 단지의 미기후 분석)

  • Kim, Chul-Hee;Jung, Eung-Ho;Kim, Dae-Wuk;Cha, Jae-Gyu
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.104-108
    • /
    • 2009
  • Rapid urbanization resulted in expansion of urban area and increase of population bringing deepened housing shortage. Supply-oriented housing policy made apartment a representative residential space in Korea in spite of the short history of apartment. This study analyzed the shape and arrangement of main building by year and the microclimate in the complex depending on the number of floors. The purpose of this study was to present the basic data in developing apartment complex to solve problems like the stagnation of pollution source and the rise of temperature due to the declined ventilation in apartment complex, and the worsened urban heat island phenomenon due to the impeded flow of wind. This study rearranged the shape and arrangement of main building by year and the tendency of the number of floors by year in the process of change, by generalizing the process of change of apartment complex, a representative modern residential space through preliminary research. Based on it, 8 object lot by age was selected and simulated by using Envi-met. Simulation identified that the change of apartment complex takes place having a positive effect on microclimate in the apartment complex and the microclimate in the apartment complex is influenced a lot by the shape of complex. If in future apartment complex plan, a systematic legal criteria of design is made about the shape and arrangement of main building, it might have a positive effect on the improvement of microclimate in the apartment complex, a representative residential space in Korea.

  • PDF

The Effects of Hot Water Supply on Energy Consumption for Floor Radiant Heating System (바닥복사 난방시스템의 공급온수특성에 따른 에너지 소비특성 연구)

  • Song, Jae-Yeob;Ahn, Byung-Cheon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.15 no.4
    • /
    • pp.32-38
    • /
    • 2019
  • In this study, the effect of hot water supply flow rates on energy consumption for radiant floor heating system in apartment were researched by computer simulation. The parametric study of different hot water supply flow rates was done with regard to energy performance and control characteristics, respectively. Also the effect of different hot water supply flow rates on the hot water supply temperatures is studied. As a result, energy consumption were reduced but the response time is increased by reducing the supply flow rate. And energy consumption can be saved by adjusting the hot water supply temperatures with different supply flow rates.

A Study on the Ventilation Efficiency of Apartment Housing Bathroom Based on the Flexible Installation Method of Exhaust Fan. (공동주택 욕실 배기팬의 플랙시블 덕트 시공상태에 따른 환기효율에 관한 연구)

  • Lee Kwang Myung;Ham Jin Sik
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.73-79
    • /
    • 2005
  • The ventilation efficiency of apartment housing bathroom has been measured by the flexible's diameter, length, and installation format to the exhaust In. The gas density attenuation method of Tracer Gas Method has been specifically utilized for this measurement. Full size mock-up of apartment housing bathroom, which was approximately $100 m^2$ in size, has been established for the ventilation emciency measurement. In addition, the ventilation efficiency has been studied by the possibility of air-supply In. The diameters of flexible are 100 mm, 125 mm, and 150mm. It also have the length of 1.0m, and 1.5 m. The installation formats are I shape, L shape, and S shape. As a result of this measurement, the flexible which has the highest ventilation efficiency was the one has bigger diameter, short in length, and I shape installation format.

A Study on the Current Trends of Cyber Apartment for Vitalizing Communities (커뮤니티 활성화를 위한 사이버 아파트 구축 현황에 관한 연구)

  • Sung, Mun-Hee;Choi, Jin-Won
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.109-114
    • /
    • 2003
  • Fast economic growth resulted in fast industrialization and metropolitanization. At that time, housing was supplied in large quantity, and the apartment became a dominant type of housing in Korea It is partly due to the high population density. But, large quantity supply of apartments caused a lot of problems. One of the biggest problems is decomposition of traditional communities. As interest about quality of life grows since the 90's, the recovery of communities is getting an import assignment that should be solved. Architects investigate ways of arrangement and community facilities planning. off-line Communities might be substituted by or supported with cyber communities through the use of IT technology. The construction of cyber apartment is getting popular by the governmental incentive in 1999. At first, the infrastructure has been constructed, and then the current emphasis in on forming the information community to provide various service.

  • PDF