• Title/Summary/Keyword: Apartment Supply

Search Result 321, Processing Time 0.025 seconds

Simulation of Pipe Network for Optimum Heat Supply in the Hot Water Heating System of Apartment House (공동주택 온수난방 시스템의 적정 열공급을 위한 배관망 시뮬레이션)

  • Kim, J.Y.;Mim, M.K.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.3
    • /
    • pp.157-168
    • /
    • 1993
  • Pipe network of hot water heat supply system in an apartment house was analyzed. Flowrate and supply heat capacity of each household in which constant flowrate balancing valve is installed in a single zone system were calculated and the results were investigated. In the existing piping system, the non-uniformity of heat supply with floors due to the static pressure and temperature difference between supply main and return main can not be avoided and this tendency get intense with the increase of the height of building. The non-uniformity of heat supply can be prevented by the installation of balancing valve at each household, however if the performance of supply pump is not sufficient to overcome the energy loss due to the installation of balancing valve for constant flow rate or if the selection of the valve capacity is not adequate, the valves will may lose their controllability.

  • PDF

The Effect of Macroeconomic and Real Estate Policies on Seoul's Apartment Prices (거시경제와 부동산정책이 서울 아파트가격에 미치는 영향 연구)

  • Bae, Jong-Chan;Chung, Jae-Ho
    • Land and Housing Review
    • /
    • v.12 no.4
    • /
    • pp.41-59
    • /
    • 2021
  • This study reviews theoretical considerations and past studies about real estate prices, macroeconomic variables, and real estate policies. Monthly data from January 2003 to June 2021 are used, and a VEC model, the most widely used multivariate time series analysis method, is employed for analysis. Through the model, the effects of macroeconomic variables and real estate regulatory policies on real estate prices in Seoul are analyzed. Findings are summarized as follows. First, macroeconomic variables such as money supply and interest rates do not have a significant impact on Seoul's apartment prices. Due to the high demand for housing and insufficient supply, there is a demand for buying a home regardless of macroeconomic booms or recessions. Second, tax and financial regulatory policies have an initial impact on the rise in apartment prices in Seoul, and their influence diminishes over time. Third, anti-speculation zones are expected to decrease apartment prices through the suppression of demand. However, these zones cause a rise in apartment prices. This could be understood as a lock-in effect due to the strengthening of capital gains tax. Fourth, the price ceiling did not decrease apartment prices. These findings propose that, in Seoul, where demand is high and supply is insufficient, the supply of high-quality and sufficient housing should be prioritized over various regulations such as tax regulations, financial regulations, anti-speculation zones, and price caps. Moreover, the findings provide an implication that city-specific real estate policies should be implemented for Seoul rather than regulation-oriented approaches in public policy.

A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System (상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구)

  • Park, Junyeol;Shin, Hwisu;Seo, Jeewon;Kim, Kibum;Koo, Jayong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.

Analysis on Heat Supply Piping Network for Apartment House (아파트의 온수공급배관망해석)

  • 박윤철;황광일
    • Journal of the Korean housing association
    • /
    • v.13 no.6
    • /
    • pp.89-99
    • /
    • 2002
  • The purpose of this research is to analyze the characteristics of flow rate distribution in hot-water piping networks in the apartment building. A 14-story apartment house was selected as a sample building and analyzed numerically by Hardy-Cross method. Two different piping networks, one has three vertical zones and the other of a single zone with automatic balancing valves, were compared. Some of research results are as follows; As the temperature of supply hot-water increases, the flow rate of it does by buoyancy effect, but this effect is not found in the piping network with automatic balancing valves. Non-uniformity in hot-water flow distributions to all stories in the piping system of single vertical zone can be completely reformed by the installation of either manually operated or automatic balancing valves in every story.

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택내 다분기챔버형 환기시스템 적용을 통한 풍량분배 개선효과에 관한 연구)

  • Kim, Sung-Soo;Son, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.545-552
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This process has been resulted increasing the initial cost for the residential ventilation system because of man-hour and accessories such as volume control damper or diffuser. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system.

A study on the Improvement of Ventilation Performance in Apartment House According to the Location of Exterior Air-Vents (공동주택에서의 실외 급.배기구 위치에 따른 환기효율 향상 연구)

  • Park, Jin-Chul;Yu, Hyung-Kyu;Cha, Jin-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.71-79
    • /
    • 2005
  • In this study, the ventilation performance of mechanical ventilation system in apartment House was analyzed through model test according to characteristics of air-vent. Then adequate interval of air-vent was suggested using computer simulation which will create comfort environment through improvement of ventilation performance in apartment house. The result of experiment with separation plate to prevent mixture of contaminated exhaust air with fresh supply air, the ventilation efficiency improved about 10%. The result of simulation with horizontal location of exterior air-vent, contaminated exhaust air is mixed regardless of interval variation. Consequently, mixture of the exhaust air can be prevented through locating the supply air vent on the top side and exhaust air vent on the lower side.

A Study on the Housing Policies and Design Characteristics of Apartment Remodeling by Comparative Analysis between Korea and France Cases (프랑스와 한국의 리모델링 사례분석을 통한 아파트 계획과 주택정책 비교 연구)

  • Jang, Han-Doo;Je, Hae-Seong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.9
    • /
    • pp.131-142
    • /
    • 2019
  • The purpose of this study was to find out the characteristics of housing policies and apartment designs by comparison of supplying and remodeling apartments between France and Korea. The literature review was used in Korea cases and the literature review, site investigation, and expert interviews were used in France cases. At first, by reviewing the related literatures about the apartment developments and regenerations in France and Korea, twelve remodeling cases were represented respectively in Ile de France and Seoul. As a result, in housing policy, the Korean housing market had a shortage of low-priced houses related to biased apartment developments by private sector dependence. Consequently, the living in Korea generally required the high price in low quality houses. But in France, the housing policies were very successful in housing quantity, quality, and expense. It is involved in balances between the public housing supply and the activation of a private housing market based on the government support policy. Nevertheless, in the success of the apartment as a house type, apartments in France means the social elimination because of the supply method problems and the management failures of HLM institutions. However, in Korea, the apartment implies the successful life of the middle class population because of the competitive evolutions during 40 years as a market housing. Secondly, In the characteristics of remodeling, the remodeling in Korea was for property value improvements. It mainly executed to expand the size of a house by expansion of living space. However the remodeling in France was for social mixes and connections with the surrounding area. It mostly performed by various design methods such as vertical merging houses, partial removal, reconstruction, and construction of a local community centers and mixed-use residential buildings. This study shows the simultaneously remodeling features of those two countries. These findings can be used in developing effective strategies for the public housing regenerations in Korea and other countries.

A study on development of dry ondol access floor system for sustainable apartment (지속가능형 공동주택 구현을 위한 건식온돌 이중바닥 시스템 개발)

  • Oh, Jin-Kyun;Sohn, Jang-Ryul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.689-689
    • /
    • 2010
  • Since the apartment was built by Korea National Housing Cooperation in 1961, the amount of its supply has been increased greatly, especially from the late 70's. Recently there are many ongoing studies regarding sustainable construction apartment in Korea, one of the research is developing sustainable apartment that has longer life cycle. Also according as life's quality of residents is upgrading, complain for impact noise and plumbing system noise from upstair or downstair are increasing more and more. To solve this complains, government established impact noise standard as lightweight impact noise of 58dB, heavyweight impact noise of 50dB and presented standard floor system or recognition floor system to satisfy this impact noise standard. So in this study, the aim is to develop dry ondol access floor system for sustainable apartment which have pleasant and quiet life environment.

  • PDF

The Economic Analysis on the Heating System Remodeling by the Life Cycle Costing in Permanent Rental Apartment (LCC 기법을 이용한 영구임대아파트 난방방식 리모델링에 대한 경제성분석 -유지관리비용을 중심으로-)

  • 박민용;장승재
    • Journal of the Korean housing association
    • /
    • v.15 no.1
    • /
    • pp.33-40
    • /
    • 2004
  • Considering the present development situation of rental apartment since 1982, the supply of rental housing for low-income dwellers has contributed a amount of quantities, but has been deficient qualities in housing policy. To propose the device of remodeling for low-income dwellers in deteriorated apartment, this study investigated the energy consumption of central heating system and the characteristics of maintenance cost in permanent rental apartment. The results of evaluation of alternative heating systems by Life Cycle Costing in permanent rental apartment were as follows; From Life Cycle 15∼20 years by Present Worth Method, the economic heating system of remodeling is central heating system (heat source: B-C oil), unit heating system(natural gas), central heating system(natural gas) in order.

A Study on the Cases and Factors of Defect Management in Apartment Housing (공동주택에서 하자관리 실태조사를 통한 공동주택 하자 유형 및 원인 분석)

  • Kang, Sang-Hun;Park, Jae-Woo;Sohn, Sung-Geun;Park, Hyun-Jung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.187-188
    • /
    • 2019
  • The supply of apartments has continuously increased, and the housing supply rate has exceeded 100 percent and the demands and standards of tenants have also been raised as technology has developed. This has led to the conflict and caused social and economic losses. In this study, the case investigation and research methods of the prior research are analyzed as the basis for identifying the defects cases of causes and influences occurring in the apartment building. To analyze various studies, we divided the prior research into the defect management process and the study on the type of defects and countermeasures, and investigated the features and limitations. Future research will be conducted on apartment buildings within 10 years of completion among conglomerate's nationwide apartments to compensate for the limitations of prior research. In addition, AHP static method and relational chart will be used to identify the relationship between the type of defect and the cause and the importance of the influencing factors.

  • PDF