• Title/Summary/Keyword: Apartment Supply

Search Result 321, Processing Time 0.022 seconds

Proposed concept design for electric vehicle charger in public places (공공장소에서의 전기 자동차 충전기 디자인 콘셉트 제안)

  • Jin, A-Young
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.13-19
    • /
    • 2022
  • Recently, electric vehicles are gaining popularity among many domestic and foreign users due to their eco-friendly advantages of reducing fine dust and environmental greenhouse gases. As the demand and supply of electric vehicles increase, the demand for electric vehicle charging infrastructure is also growing together. Many users are experiencing inconvenience due to poor charging infrastructure, which makes them hesitant to buy electric vehicles. Research on the user experience of chargers in apartment complexes, a common residential type in Korea, is being conducted somewhat, but research on the design of electric vehicle charging devices in public places is insufficient. The purpose of this research is to identify user requirements and complaints based on the product design of the electric vehicle charger in public places and propose a new electric vehicle product design concept that meets the requirements. The research method understood the charging base and status of electric vehicles in public places through literature research and examined and analyzed the characteristics and problems of product design cases that improved the charging problem of electric vehicles recently released in the market. It is intended to identify and analyze the problems of the charging device product design through user interviews, a qualitative research method, and based on this, it is intended to propose a user-centered product design concept that improves major complaints.

A Study on the Planning and its Periodic Changes of Public Housing in Malaysia (말레이시아 공공부문공동주택 계획의 특성 및 시대별 추이에 관한 연구)

  • JU, Seo Ryeung;JEON, So Young
    • The Southeast Asian review
    • /
    • v.22 no.1
    • /
    • pp.207-245
    • /
    • 2012
  • With rapid industrialization and urbanization, numerous cities are faced with urban slum phenomenon combined with housing shortage fueled by population explosion. In Kuala Lumpur, the capital city of Malaysia, the government hereby embarked on supply of public housing to resolve such pending issue. This study aims to understand the periodic changes of public housing as a common basis for basic housing policies with analysis specific features of site plan, block layout, and unit plans. For this purposes, the filed survey during January, 2011 were proceeded. We hereby visited and surveyed a total of 40 apartment complexes for the 1970s~the 2000s (10 complexes respectively on a decade basis). Consequently, Malaysian public apartments prove to offer a very uniform pattern based upon standard plans. Their early plans aren't fairly distincted from those of other countries, but their layouts of plan become differentiated compared with other nations as they actively apply a ventilator called 'air well' in response to tropical climate amid the change of times. This study is expected to broaden our understanding of Malaysia's unique housing culture and lifestyle.

An Application of GIS Technique to Analyze the Location of Fastfood Stores : The Case of Kangnam-Gu , Seoul (GIS 기법을 활용한 패스트푸드점의 입지분석에 관한 연구 - 서울시 강남구를 중심으로)

  • 이희연;이정미
    • Spatial Information Research
    • /
    • v.4 no.2
    • /
    • pp.131-146
    • /
    • 1996
  • The purpose of this study is to extract the main locational factors to affect the location of fastfood stores in Kangnam -Gu, Seoul by using Geographic Information Systems. The Franchise system, which came to be employed in full scale since 1990, now enjoying the booming period, especially fast food industry. The procedure of this research has four steps. First, the spatial distribution of fastfood chain stores in Seoul is analyzed by the land use and road map. Second, the spatial variations of fastfood stores in dong districts of Seoul is explained by multiple regression analysis. Third, the main locational factors to affect the location of fast food stores in Kangnam -Gu are extracted by demand and supply sides using GIS technologies. Finally, the potentiallocational zones where are selected by extracted locational factors are compared with the actual distribution of f astf ood stores in Kangnam - Gu. In terms of demand side, the main locational factors include commercial and service facilities, sub¬ways and bus stops which have a lot of pedestrians, and large apartment districts that have high popu¬lation densities. In terms of supply sides, the main locational factors include land use types and land value, accessibility. After fast food chain stores of Kangnam -Gu are overlaid final potentiallocational zones extracted by demand and supply sides of locational factors, it can be identified that over 80 % of fastfood stores are located in the potentiallocational zone. In conclusion, this study shows that spatial analysis functions may potentially be improved using GIS technologies. However there are still difficulties for the locational analysis for service industries to col¬lect appropriate data in terms of computerized base maps as well as consumer behavior and store characteristics itself.

  • PDF

Development and Safety Evaluation of Earth Leakage Alarm Breaker Equipped with Fire Current (IGR) Alarming Function (화재전류(IGR) 경보 기능이 내장된 누전경보차단기의 개발 및 안전성 평가에 관한 연구)

  • Ko, Wan-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The purpose of this study is to develop an earth leakage alarm circuit breaker, equipped with a leakage alarming function (JER-E2S, ETECKOREA Co., Korea), and to analyze its characteristics. The developed mechanism is exclusively used for single-phase and 220 V circuits, with a rated current of 32 A, 20 A, 20 A (for restrooms), 16 A, etc. It satisfies all characteristics of existing earth leakage circuit breakers (ELB). If a fire current, which is a resistive leakage current (Igr), flows through an electric line, the device detects the leakage current in real time and warns against the leakage through a blinking LED lamp. Since the developed device displays a tolerance to a capacitative leakage current (Igc) that inevitably occurs in LED lamps, communication devices, etc., it ensures a stable power supply. In addition, the earth leakage alarm circuit breaker protects against power failure due to a momentary ground fault. Therefore, it can supply power without the risk of the circuit breaker malfunctioning due to a momentary ground fault caused by water droplets, leaves, etc. Moreover, with a standby power of less than 0.1 W, the developed earth leakage alarm circuit breaker exhibits a power saving performance that is 3~8 times greater than that of other ELBs. Installation of approximately 10 earth leakage alarm circuit breakers in one apartment household, with an area of 120 ㎡, can save 2~5 kWh per month. Therefore, the developed earth leakage alarm breaker not only satisfies the characteristics of existing earth leakage breakers, but also exhibits outstanding power supply quality since it has the functions of electric fire prevention and malfunction prevention. Therefore, this device can innovatively contribute to electric fire prevention.

Development of Estimation Models for Parking Units -Focused on Gwangju Metropolitan City Condominium Apartments- (주차원단위 산정 모형 개발에 관한 연구 -광주광역시 공동 주택 아파트를 대상으로-)

  • Kwon, Sung-Dae;Ko, Dong-Bong;Park, Je-Jin;Ha, Tae-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.549-559
    • /
    • 2014
  • The rapid expansion of cities led to the shortage of housing in urban areas. The government compensated for this shortage through large scale residential developments that increased the housing supply. The supply of condominium apartments remains above 83% of the entire housing supply, and the proportion of apartments are at a steady increase, at about 50%. Due to the increase, illegally parked cars resulting from the shortage of parking spaces within the apartment complex have become increasingly problematic as they block the transit of emergency vehicles, and heighten the tension among neighboring residents in obtaining a parking space. Especially, the future residents are considered to plan the parking based on the estimated demand for parking. However, the parking unit method utilized to estimate the parking demand accounts for the exclusive use of space, which is believed to be far from the parking demands in reality. The reason for this discrepancy is that, as the number of households decrease, and area of exclusive space is expanded, the planned parking increases. On the other hand, when the number of households increase, and the area of exclusive space is reduced, the planned parking decreases, thus methods to recalculate the parking units based on estimated parking demand is an urgent concern. To estimate the parking units based on condominium apartments, this study first examined the existing research literature, and appointed the field of investigation to collect the necessary data. In addition, field study data and surveys collected and analyzed, in order to identify the problems underlying parking units, and problems regarding the current traffic impact assessment parking unit calculation method were deduced. Through identifying the influential factors on parking demand estimates, and performing a factorial analysis based on the collected data, the variables were selected in relation to the parking demand estimates, to develop the parking unit estimate model. Finally, through comparing and verifying the existing traffic impact assessment parking unit estimate against the newly developed model using collected data, a far more realistic parking unite estimate was suggested, reflecting the characteristics of the residents. The parking unit estimate model developed in this study is anticipated to serve as the guidelines for future parking lot legislature, as wel as the basis to provide a more realistic estimate of parking demands based on the resident characteristics of an apartment complex.

A Study on the Water Quality of Reservoir Tank in the Building Complex on Jeonnam Area (대형건축물 저수조의 수질실태 및 개선방안에 관한 연구)

  • Lee, J.H.;Lee, H.H.;Kim, H.B.;Ahn, G.W.;Park, K.N.;Kim, Y.K.;Bae, J.S.;Mun, H.;Park, C.U.;Oh, E.H.;Park, S.I.;Seo, Y.G.
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.59-77
    • /
    • 2000
  • This study was carried out to investigate on several factors, which contaminative the water quality through the water pipe during feeding water, in 42 largescaled apart-ments(total 84 cases) and assayed the Volatile Organic Compounds(VOCs) and concen-tration of heavy metals that inflow and outflow in reservior water in Jeonnam area(Mokpo, Suncheon, Yeosu) from January 1999 to December 1999. The results obtained were summarized as follows ; 1. The quality of the water pipe composition in the order of frequency in the quality of water pipes were Copper(45.2%)> Zinc(38.9%)> Stainless steel(9.5%)> PVC(4.8%)> PM(2.4%) in observing 42 sites. All of the drain pipes were used the cast iron quality. 2. The result of certification curve from 12 items(17kind) of VOCs was $1.0-4.0{\mu{g}}/{\ell}$ range, a coefficient of correlation was shown 0.99 over. A MDL of each substance range was within $0.1-1.0{\mu{g}}/{\ell}$. 3. The result of the assay, 5 kinds(Viny chloride, Dichloromethane, Ethylbenzene, M,P-xylene, Styrene) of the VOCs of 14 kinds was not detected and the other items were detected slightly. The detection rate of one item and over in total VOCs samples, were 25.9% in inflow and 27.9% in outflow. And frequency of detect in inflow/outflow of THM(Chloroform, Bromodichloro-methane, Dibromochloromethane, Bromoform) were shown higher than 94.1%, 97.0% each stages. It comes to the conclusion that all of the samples were reason able for drinking water standards. 4. The coefficient of correlation were reasonable, it shown 0.999 over in $0.1-1.0{\mu{g}}/{\ell}$ of a measuring range conditions of 4kinds in organic substance(Zn, Cu, Fe, Mn). 5. The results were showed suitability in 78 cases(92.9%) and unsuitability in 6 cases (7.1%), in 84 cases of in organic substances. Compare to inflow stage, mean concentrations of heavy metal, were increased slightly in Zn, Cu, Fe except Mn than outflow stage. The result of the mean concentration in organic substance inflow and outflow in the apartment water tank using Pair-compared T-test, in 95% reliance index, were $0.179mg/{\ell}(0.151-0.307mg/{\ell})$ in Zinc, $0.136mg/{\ell}(0.113-0.230mg/{\ell})$ in Copper, $0.052mg/{\ell}(0.048-0.098mg/{\ell})$ in Fe, and there was a bit growing tendency but there was no differece in Mn. 6. The mean concentration of Copper which used Cu pipe as a water supply pipe in apartment were $0.216mg/{\ell}(0.161-0.338mg/{\ell})$ in case of the Zine pipe were $0.286mg/{\ell}(0.204-0.435mg/{\ell})$. It shows that the detection rate was more higher than the other material used in Cu or Zn as the water supply pipe. We supposed to Cu and Zn substance were gushing out water supply pipe.

  • PDF

Estimation and Adjustment Model Considering Time Value of Money for Long-Term Maintenance Cost of Apartment House (시간적 가치를 고려한 공동주택 장기수선충당금 산정 및 조정 모델)

  • Koo, Seonkeun;Kim, Jonghyeob;Jun, Inyeong;Kim, Yeongjin;Yoon, Yousang;Hyun, Changtaek
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.3
    • /
    • pp.12-21
    • /
    • 2017
  • From 1960, the government decided to build apartment houses on a large scale in order to resolve the rising housing problems. However, the maintenance issues that have arisen from the deterioration of housing has not received adequate attention. The policy focuses only on the supply of housing. By passing new laws, the durable period during which buildings allowed reconstruction was increased, and long term maintenance plans were treated as important issues. The government was then obligated to establish certain long term maintenance plans and costs by legislating a Housing Act and requiring it be adjusted every three years. However, when planning long-term repair costs, doing so without considering the time value of money would become a problem. In addition, if differences between the planned repair costs and actual costs occur, it becomes necessary to adjust the long-term repair costs but, as of yet, the criteria to adjust such things does not exist. For these reasons, if there is lack of money to execute large-scale repair work, a building is unlikely to respond to deterioration of housing; on the other hand, an unnecessary reserve or pool of money can lead to conflict among residents. Therefore, this paper will propose estimation and adjustment models considering the time value of money for long term maintenance costs of apartment houses.

Analysis of the Public Rental Housing Default in Korea (공공건설 임대주택의 부도 실태에 관한 연구)

  • Kim, Han-Su;Im, Jun-Hong
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.484-493
    • /
    • 2013
  • The Korean Government has provided public rental housing to stabilize civilian dwelling. However, unreliable management of public rental housing threatens the stability of residency. This study analyzes the default of public rental housing and the cause of default through a case study, which was intended for the residents in apartment complexes in danger of default. It also suggests countermeasures to cope with the problem of public rental housing. The results are listed as follows. First, rental housing apartments contribute a lot to the housing stability policy. On the other hand, the default of housing development, which is derived from the bankruptcy of housing management companies and the negligent control of government, brings about a serious problem for housing stability. Second, although the government has made a steady effort to solve this default problem, 9000 residents from 8 apartment complexes in Korea have experienced extreme unstable residency. Third, there are many causes for the default of public rental housing such as unqualified management companies and cursory monitoring by the government. The fundamental solution is to prevent public rental housing management companies from managing, or to build a new management system of public rental housing. To solve this problem, it's recommendable to delete the application term in the special law on the default of public rental housing so that it can be applied to all default apartments. If it is not possible to perform the policy for financial reasons, a new supply of civil housing provided by private companies needs to be re-examined completely or banned.

The Study on Automatic Temperature Transmission System for the Heating pipe at Home (가정식난방배수관내의자동온도송신장치에대한연구)

  • Park, Chul-Min;Jo, Heung-Kuk;Lee, Hoon-Jae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2641-2646
    • /
    • 2009
  • The more growing on home automation system at automatic control, the more efficiency required for energy consumption and for recycling energy in near future. Heating is essential in general apartment. Heating method is two types in apartment. One uses electricity, and other one uses warm water. If use electricity, is not efficient by rise of electric charges. But, It can reduce much in expense aspect, if use warm water. When use warm water, temperature of warm water is not equal from all pipe parts. Therefore, indoor tempera can be unequal with set point. Solution of these problems is as following. Temperature sensor in warm water attach pipe. The measured temperature transmits by real time. Temperature of warm water controls in receiver side. In this paper, we propose an automatic temperature transmission system for the heating pipe at home, that is a low-power based, and supply the energy source from a small AC motor resided in bottom cement mortal. The proposed system is used in power mechanism from a collision process of water-jet using propeller water-difference and also designed a CPU module by Atmega8 at ATMEL co., Inc. and a communication module by CC1020 at Chipcon co., Inc.

Analysis on the Effect of Regional Characteristics and Housing Market Characteristics on Population Growth (지역 및 주택 시장 특성이 인구 증가에 미치는 영향 분석)

  • Oh, Sang-Ho;Suh, Jeong-Yeal
    • Journal of Cadastre & Land InformatiX
    • /
    • v.49 no.1
    • /
    • pp.123-144
    • /
    • 2019
  • The purpose of this study is to grasp factors the increasing population growth rate of the region through the regional and housing market characteristics. This paper has used multiple regression as the dependent variable (average of the population growth rate of 85cities during the last five years) and the independent variables analyzed the regional and housing market characteristics on the average. The results of the analysis, The regional and housing market variables that have had a significant impact on the regional population growth rate over the last five years are birth rate, employment rate, production available population growth rate, apartment rate, resale rights rate, and apartment turnover rate and the number of businesses per thousand and has decreased. In other words, The regions where the population increased by region for the last five years were the ones with the transfer of public institutions (innovation cities) and land development among the Seoul metropolitan area and non-Seoul metropolitan area excluding Seoul and metropolitan cities. The results of this study is intentional to suggest Policy point of view for the balanced regional development presented at the government level for other the metropolitan area, such as the small and medium cities that are undergoing population decline.