• 제목/요약/키워드: Aortic valve, surgery

검색결과 584건 처리시간 0.026초

Minimally Invasive Approach for Redo Mitral Valve Replacement: No Aortic Cross-Clamping and No Cardioplegia

  • Kim, Hong Rae;Kim, Gwan Sic;Yoo, Jae Suk;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • 제48권2호
    • /
    • pp.126-128
    • /
    • 2015
  • A 75-year-old woman who had previously undergone a double valve replacement was admitted to Asan Medical Center because of severe bioprosthetic mitral valve dysfunction and tricuspid regurgitation. Under hypothermic fibrillatory arrest without aortic cross-clamping, minimally invasive mitral and tricuspid valve surgery was performed via a right minithoracotomy.

대동맥판륜 성형술을 동반한 Ross 술식 (Ross Operation with Aortic Ring Annuloplasty)

  • 이재원;정성호;김건일;송명근
    • Journal of Chest Surgery
    • /
    • 제33권9호
    • /
    • pp.744-747
    • /
    • 2000
  • Pulmonic autograft replacement of the aortic valve(Ross procedure) has been to have potential for growth in children, no complication of antiocagulation, and enhanced durability. Therefore, Ross operation is indicated in the young, in patients with an active life style, and when anticoagulation is contraindicated. However, late autograft valve has occurrd more frequently in patients with significant size discrepancy between the pulmonay valve annulus and the aortic valve annulus. In order to resolve this problem, we performed aortic annuloplasty with Duran ring for more accurate and strong reinforcement. We report a case using the Duran ring as a method of aortic annuloplasty during Ross procedure.

  • PDF

Subvalvular Septal Myectomy and Enlargement of the Narrow Aortic Root in Patients with Aortic Valve Replacement

  • Schulte, H.D.;Birchs, W;Horstkotte, D;Kim, Y.H.;Kerstholt, J;Preusse, C.J.;Winter, J
    • Journal of Chest Surgery
    • /
    • 제22권2호
    • /
    • pp.220-224
    • /
    • 1989
  • In candidates for aortic valve replacement [AVR]it is our primary intention to implant the largest possible vale prosthesis of at least 23 mm in diameter in patients with severe valvular aortic stenosis. However, in many patients there is an additional subvalvular asymmetric septal hypertrophy which in some cases may cause an postextrasystolic increase of the LV-aortic gradient. Another component of the aortic stenosis syndrome is a narrow valvular ring, or a combination of both. After complete removal of the diseased valve and decalcification the narrow aortic ring [< 23 mm] can be widened firstly by transaortic subvalvular septal myectomy- [TSM] thus unfolding the left ventricular outflow tract[LVOT]and secondly by extending the oblique aortic incision into the aortic valve ring or further down into the anterior leaflet of the mitral valve. The sub-and supra-valvular defect will be closed by patch enlargement of the aortic root [PEAR] using autologous pericardium. These techniques allow a considerable enlargement of the valvular ring of about 4 to 10 mm in circumference. In a retrospective study using a computerized program, 847 patients with AVR [1980-1984]were reviewed to evaluate the intraoperative hemodynamic results mainly concerning relief of the transvalvular gradient. In 626 patients AVR was performed, 151 patients had double valve replacement [AVR+MVR], and 70 patients had AVR plus additional surgical procedures. Concentrating on the AVR-group [n=626] there were 103 patients with TSM, 24 patients with PEAR and 20 patients with TSM+PEAR which demonstrated that in a total, of 147 patients of this groups [23.5%] an additional procedure was necessary. The Statistical evaluation of the intraoperative pressure measurements before and after AVR in relation to the size of the implanted prostheses indicated the lowest preoperative mean gradient in patients with AVR alone, the highest in patients who afforded TSM plus PEAR. However, after AVR the mean gradients in all three groups were very low [mean 5 to 10 mmHg]. These data indicate that in patients with a narrow aortic ring and additional considerable ASH, TSM and PEAR are suitable techniques to enlarge the aortic root to enable the implantation of an adequate aortic valve prosthesis. Long-term controls have shown that autologous pericardium is a qualified graft material for the ascending aorta.

  • PDF

선천성 사엽성 대동맥 판막 질환 (Congenital Quadricuspid Aortic Valve Disease)

  • 박찬범;김재준;조민섭;진웅;조덕곤;박건;조규도;김치경
    • Journal of Chest Surgery
    • /
    • 제38권11호
    • /
    • pp.780-782
    • /
    • 2005
  • 사엽성 대동맥 판막 질환은 매우 드문 선천적 심기형이다. 혈역학적으로 사엽성 대동맥 판막 질환은 대부분 판막폐쇄부전을 일으키며, 드물게는 협착과 폐쇄부전을 동반하거나 협착 소견만을 보이기도 한다. 저자들은 매우 드문 것으로 알려진 사엽성 대동맥 판막 질환을 경험하여 보고하는 바이다.

Clinical Midterm Results of Surgical Aortic Valve Replacement with Sutureless Valves

  • Soonchang Hong;Jung-Woo Son;Yungjin Yoon
    • Journal of Chest Surgery
    • /
    • 제57권3호
    • /
    • pp.255-262
    • /
    • 2024
  • Background: Sutureless aortic valves may enable shorter procedure times, which benefits patients with elevated surgical risk. We describe the outcomes of patients with aortic stenosis who underwent aortic valve replacement (AVR) using the sutureless Perceval aortic bioprosthesis. Methods: Data from a retrospective cohort were obtained from a clinical database. The study enrolled patients with symptomatic severe aortic stenosis who underwent surgical AVR with a sutureless bioprosthesis between August 2015 and December 2020. In total, 113 patients were included (mean age, 75.3±8.4 years; 57.5% women; median Society of Thoracic Surgeons score, 9.7%; mean follow-up period, 51.19±20.6 months). Of these patients, 41 were octogenarians (36.2%) and 3 were nonagenarians (2.6%). Transthoracic echocardiography was employed to assess changes in ejection fraction (EF), left ventricular mass index (LVMI), and mean pressure gradient (MPG). Results: The in-hospital mortality rate was 2.6%, and 13 patients developed new-onset atrial fibrillation. A permanent pacemaker was implanted in 3 patients (2.6%). The median intensive care unit stay was 1 day (interquartile range [IQR], 1-2 days), and the median hospital stay was 12 days (IQR, 9.5-15 days). The overall survival rate at 5 years was 95.9%. LVMI and MPG were reduced postoperatively, while EF increased over the follow-up period. No structural valve deterioration was observed, and no meaningful paravalvular leakage developed during follow-up. Conclusion: The use of a sutureless valve in the aortic position is safe and feasible, even for high-risk elderly patients requiring surgical AVR. LVMI and MPG decreased postoperatively, while EF increased over the follow-up period.

Mechanical versus Tissue Aortic Prosthesis in Sexagenarians: Comparison of Hemodynamic and Clinical Outcomes

  • Son, Jongbae;Cho, Yang Hyun;Jeong, Dong Seop;Sung, Kiick;Kim, Wook Sung;Lee, Young Tak;Park, Pyo Won
    • Journal of Chest Surgery
    • /
    • 제51권2호
    • /
    • pp.100-108
    • /
    • 2018
  • Background: The question of which type of prosthetic aortic valve leads to the best outcomes in patients in their 60s remains controversial. We examined the hemodynamic and clinical outcomes of aortic valve replacement in sexagenarians according to the type of prosthesis. Methods: We retrospectively reviewed 270 patients in their 60s who underwent first-time aortic valve replacement from 1995 to 2011. Early and late mortality, major adverse valve-related events, anticoagulation-related events, and hemodynamic outcomes were assessed. The mean follow-up duration was $58.7{\pm}44.0$ months. Results: Of the 270 patients, 93 had a mechanical prosthesis (mechanical group), and 177 had a bioprosthesis (tissue group). The tissue group had a higher mean age and prevalence of preoperative stroke than the mechanical group. The groups had no differences in the aortic valve mean pressure gradient (AVMPG) or the left ventricular mass index (LVMI) at 5 years after surgery. In a sub-analysis limited to prostheses in the supra-annular position, the AVMPG was higher in the tissue group, but the LVMI was still not significantly different. There was no early mortality. The 10-year survival rate was 83% in the mechanical group and 90% in the tissue group. The type of aortic prosthesis did not influence overall mortality, cardiac mortality, or major adverse valve-related events. Anticoagulation-related events were more common in the mechanical group than in the tissue group (p=0.034; hazard ratio, 4.100; 95% confidence interval, 1.111-15.132). Conclusion: The type of aortic prosthesis was not associated with hemodynamic or clinical outcomes, except for anticoagulation-related events.

Early Clinical Experience with Sutureless Aortic Valve Replacement for Severe Aortic Stenosis

  • Kim, Do Jung;Kim, Hyo-Hyun;Lee, Shin-Young;Lee, Sak;Chang, Byung-Chul
    • Journal of Chest Surgery
    • /
    • 제51권1호
    • /
    • pp.1-7
    • /
    • 2018
  • Background: Sutureless aortic valve replacement (SU-AVR) has been developed as an alternative surgical treatment for patients with symptomatic severe aortic stenosis (AS). The aim of this study was to evaluate the clinical outcomes of SU-AVR through an assessment of hemodynamic performance and safety. Methods: From December 2014 to June 2016, a total of 12 consecutive patients with severe AS underwent SU-AVR. The endpoints were overall survival and valve-related complications (paravalvular leakage, valve thrombosis, migration, endocarditis, and permanent pacemaker implantation). The mean follow-up duration was $18.1{\pm}8.6months$. Results: The mean age of the patients was $77.1{\pm}5.8years$ and their mean Society of Thoracic Surgeons score was $9.2{\pm}17.7$. The mean cardiopulmonary bypass and aortic cross-clamp times were $94.5{\pm}37.3$ minutes and $54.9{\pm}12.5minutes$, respectively. Follow-up echocardiography showed good prosthesis function with low transvalvular pressure gradients (mean, $13.9{\pm}8.6mm\;Hg$ and peak, $27.2{\pm}15.0mm\;Hg$) at a mean of $9.9{\pm}4.2months$. No cases of primary paravalvular leakage, valve thrombosis, migration, or endocarditis were reported. A new permanent pacemaker was implanted in 1 patient (8.3%). The 1-year overall survival rate was $83.3%{\pm}10.8%$. Conclusion: Our initial experience with SU-AVR demonstrated excellent early clinical outcomes with good hemodynamic results. However, there was a high incidence of permanent pacemaker implantation compared to the rate for conventional AVR, which is a problem that should be solved.

심장판막질환과 동반된 관상동맥질환의 수술 (Cardiac Valve Replacement and Simultaneous Myocardial Revascularization)

  • Reiner, Korfer;Jee, Heng-Ok
    • Journal of Chest Surgery
    • /
    • 제21권1호
    • /
    • pp.164-168
    • /
    • 1988
  • Between November, 1984, and May, 1986, 93 patients underwent combined valvular and coronary artery operation. They were 70 male and 23 female, the age ranging from 29 to 82. From this population 89 patients underwent single valve replacement and 4 patients underwent double valve replacement. Patients with mitral valve disease were in the majority present in the age group between 50 till 70, where as in the group after 60 years, patients with aortic valve disease were dominant. The main indication for aortic valve replacement was aortic stenosis and the indication for mitral valve replacement was equal between mitral stenosis and mitral incompetence, the later was due to papillary dysfunction after myocardial infarction. Dyspnea was a very frequent symptom and it was found in nearly all patients. 28 patients had a previous myocardial infarction and severe left ventricular dysfunction. The grafts were placed prior to valve replacement and periods of myocardial ischemia were kept at a minimum by maintaining coronary perfusion throughout the operation. It is our opinion that simultaneous valve replacement and myocardial revascularization does not increase the risk of cardiac valve replacement substantially.

  • PDF

협소한 대동맥판윤의 첨포확대후 대동맥 및 승모판막 대치술 치험 1예 (Mitral and Aortic Valce Replacement with Patch Enlargement of Narrow Aortic Annulus)

  • 강면식
    • Journal of Chest Surgery
    • /
    • 제12권1호
    • /
    • pp.56-60
    • /
    • 1979
  • Replacement of the aortic valve in a normal or large aortic root can be accomplished with ease and safety in most instances. The presence of a narrowed aortic annulus remains a problem in that the replaced smaller prosthetic valve has a significant resting pressure gradient across the orifice. This narrowing causes not only technical difficulties, but also increased mortality and post-op. complication. Therefore this problem deserves special attention. This report presents our experience with a case of a small aortic root caused by rheumatic heart disease [AI and MS]. This is the method of enlargement of the aortic annulus with a woven Dacron patch and replacement of a larger prosthetic aortic valve combined with mitral valve replacement.

  • PDF

Valve-Sparing Neo-Aortic Root Replacement for Neo-Aortic Root Dilatation 20 Years after Arterial Switch Operation for Transposition of the Great Arteries: A Case Report

  • Sangjun Lee;Chan Hyeong Kim;Jae Hong Lee;Jae Gun Kwak
    • Journal of Chest Surgery
    • /
    • 제56권6호
    • /
    • pp.445-448
    • /
    • 2023
  • A 25-year-old man returned to Seoul National University Children's Hospital with mild dyspnea on exertion. He had undergone an arterial switch operation at 1 month after birth to correct a complete transposition of the great arteries and a ventricular septal defect. When the patient was 15 years old, dilatation of the neo-aortic sinus and annulus was first identified; since then, it had gradually increased. Given the young age of the patient and the degree of aortic regurgitation (AR), which was mild to moderate, we opted to perform a valve-sparing neo-aortic root replacement with aortic valve repair. Postoperative echocardiography showed successful reductions in the sizes of the aortic sinus and annulus, with only mild AR remaining.