• Title/Summary/Keyword: Aortic valve, surgery

Search Result 584, Processing Time 0.025 seconds

Surgical Management of Aortic Root Dilatation with Advanced Aortic Regurgitation: Bentall Operation versus Valve-sparing Procedure

  • Lim, Ju-Yong;Kim, Joon-Bum;Jung, Sung-Ho;Choo, Suk-Jung;Chung, Cheol-Hyun;Lee, Jae-Won
    • Journal of Chest Surgery
    • /
    • v.45 no.3
    • /
    • pp.141-147
    • /
    • 2012
  • Background: Although the aortic valve-sparing procedure has gained popularity in recent years, it still remains challenging in patients with advanced aortic regurgitation (AR). We compared the long-term outcomes of the aortic valve-sparing procedure with the Bentall operation in patients with advanced aortic regurgitation secondary to aortic root dilatation. Materials and Methods: A retrospective review of 120 patients who underwent surgery for aortic root dilatation with moderate to severe AR between January 1999 and June 2009 was performed. Forty-eight patients underwent valve-sparing procedures (valve-sparing group), and 72 patients underwent the Bentall procedure (Bentall group). The two groups' overall survival, valve-related complications, and aortic valve function were compared. Results: The mean follow-up duration was $4.9{\pm}3.1$ years. After adjustment, the valve-sparing group had similar risks of death (hazard ratio [HR], 0.61; p=0.45), and valve related complications (HR, 1.27; p=0.66). However, a significant number of patients developed moderate to severe AR in the valve-sparing group at a mean of $4.4{\pm}2.5$ years of echocardiographic follow-up (p<0.001). Conclusion: Both the Bentall operation and aortic valve-sparing procedure showed comparable long-term clinical results in patients with advanced aortic regurgitation with aortic root dilatation. However, recurrent advanced aortic regurgitation was more frequently observed following valve-sparing procedures.

Bentall Operation in a Patient with a Unicommissural Unicuspid Aortic Valve

  • Park, Sung Joon;Lee, Jae Hoon;Chung, Eui Suk
    • Journal of Chest Surgery
    • /
    • v.52 no.5
    • /
    • pp.368-371
    • /
    • 2019
  • A unicuspid aortic valve is a rare congenital malformation that frequently presents with valvular dysfunction and dilatation or aortic aneurysm, requiring combined aortic valve surgery and aortic repair. Some patients show severe valve calcification extending into the interventricular septum, possibly resulting in damage to the conduction system during debridement for valve replacement. We present a rare case of severe aortic stenosis with a unicommissural unicuspid aortic valve diagnosed by preoperative transesophageal echocardiography in a 36-year-old man. After composite graft replacement of the aortic valve, aortic root, and ascending aorta, a permanent pacemaker was placed because of postoperative complete heart block.

Aortic Valve Sparing Operations: A Review

  • David, Tirone E.
    • Journal of Chest Surgery
    • /
    • v.45 no.4
    • /
    • pp.205-212
    • /
    • 2012
  • Aortic valve sparing operations were developed to preserve the native aortic valve during surgery for aortic root aneurysm as well as surgery for ascending aortic aneurysms with associated aortic insufficiency. There are basically two types of aortic valve sparing oprations: remodeling of the aortic root and reimplantation of the aortic valve. These operations have been performed for over two decades and the clinical outcomes have been excellent in experienced hands. Although remodeling of the aortic root is physiologically superior to reimplantation of the aortic valve, long-term follow-up suggests that the latter is associated with lower risk of developing aortic insufficiency. Failure of remodeling of the aortic root is often due to dilatation of the aortic annulus. Thus, this type of aortic valve sparing should be reserved for older patients with ascending aortic aneurysm and normal aortic annulus whereas reimplantation of the aortic valve is more appropriate for young patients with inherited disorders that cause aortic root aneurysms. This article summarizes the published experience with these two operations. They are no longer experimental procedures and should be part of the surgical armamentarium to treat patients with aortic root aneurysm and ascending aortic aneurysms with associated aortic insufficiency.

Emergency Quadrido-Bentall Procedure for Aortic Rupture in a Patient with Behcet's Disease

  • Park, Sung Jun;Lee, Jeong-woo;Kim, Joon Bum
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.364-367
    • /
    • 2015
  • Cardiovascular involvement in cases of Behcet's disease is a rare but life-threatening condition, and prosthetic valve detachment is a frequent and serious complication attributable to Behcet's disease following the surgical repair of aortic regurgitation. We report the case of a patient with Behcet's disease presenting with contained aortic rupture around the aortic root. The patient had previously undergone aortic valve surgery three times due to recurrent prosthetic valve detachment. An emergency operation was performed, consisting of aortic root replacement (ARR) using a composite valved conduit and the replacement of the hemiarch. ARR may be an appropriate surgical option for patients with Behcet's disease in order to prevent recurrence of the disease.

Comparable Outcomes of Bicuspid Aortic Valves for Rapid-Deployment Aortic Valve Replacement

  • Somin Im;Kyung Hwan Kim;Suk Ho Sohn;Yoonjin Kang;Ji Seong Kim;Jae Woong Choi
    • Journal of Chest Surgery
    • /
    • v.56 no.6
    • /
    • pp.435-444
    • /
    • 2023
  • Background: Edwards Intuity is recognized as a relatively contraindicated bioprosthesis for bicuspid aortic valve disease. This study compared the early echocardiographic and clinical outcomes of rapid-deployment aortic valve replacement for bicuspid versus tricuspid aortic valves. Methods: Of 278 patients who underwent rapid-deployment aortic valve replacement using Intuity at Seoul National University Hospital, 252 patients were enrolled after excluding those with pure aortic regurgitation, prosthetic valve failure, endocarditis, and quadricuspid valves. The bicuspid and tricuspid groups included 147 and 105 patients, respectively. Early outcomes and the incidence of paravalvular leak were compared between the groups. A subgroup analysis compared the outcomes for type 0 versus type 1 or 2 bicuspid valves. Results: The bicuspid group had more male and younger patients. Comorbidities, including diabetes mellitus, hypertension, chronic kidney disease, and coronary artery disease, were less prevalent in the bicuspid group. Early echocardiographic evaluations demonstrated that the incidence of ≥mild paravalvular leak did not differ significantly between the groups (5.5% vs. 1.0% in the bicuspid vs. tricuspid groups, p=0.09), and the early clinical outcomes were also comparable between the groups. In the subgroup analysis between type 0 and type 1 or 2 bicuspid valves, the incidence of mild or greater paravalvular leak (2.4% vs. 6.7% in type 0 vs. type 1 or 2, p=0.34) and clinical outcomes were comparable. Conclusion: Rapid-deployment aortic valve replacement for bicuspid aortic valves demonstrated comparable early echocardiographic and clinical outcomes to those for tricuspid aortic valves, and the outcomes were also satisfactory for type 0 bicuspid aortic valves.

Neo-Leaflet Failure after Comprehensive Aortic Root and Valve Reconstruction

  • Park, Sung Jun;Lee, Jeong Woo;Chung, Cheol Hyun
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.359-363
    • /
    • 2015
  • The comprehensive aortic root and valve reconstruction (CARVAR) technique comprises two main procedures, which are aortic root reduction using prosthetic rings and neo-leaflet reconstruction using a pericardial patch. Although concerns about durability of the pericardial neo-leaflet have been raised in the CARVAR technique, complications related to leaflet reconstruction have not been reported to date. The present report describes two cases of complications associated with leaflet reconstruction. After resecting the reconstructed leaflets, aortic valve replacement was performed in the patients. Careful and close follow-up is required for patients who had undergone CARVAR surgery, and aortic valve surgery should be performed in a timely manner if needed.

Two-Dimensional Echocardiographic Prediction of Prosthetic Aortic Valve Size (심초음파도를 이용한 대동맥인공판막치수 예)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.655-658
    • /
    • 1987
  • Aortic annulus size was measured by two-dimensional echocardiography [2DE] in 29 patients undergoing aortic valve replacement or double valve replacement in order to predict prosthetic aortic valve size. Fifteen patients had aortic stenoinsufficiency, eleven had aortic insufficiency, and three had aortic stenosis. 2DE measurements of aortic annulus diameter, as determined from the parasternal long-axis view, demonstrated a high correlation with actual prosthetic valve size implanted at surgery [r=0.85, p<0.05]. 2DE exactly predicted actual prosthetic valve size in 8 of 29 patients [27.6%], was within 1mm of prosthetic valve size in 11 of 29 patients [37.9%], was within 2mm of prosthetic valve size in 8 of 29 patients, and was within 3mm of prosthetic valve size in 2 patients.

  • PDF

Aortic Periannular Abscess Invading into the Central Fibrous Body, Mitral Valve, and Tricuspid Valve

  • Oh, Hyun Kong;Kim, Nan Yeol;Kang, Min-Woong;Kang, Shin Kwang;Yu, Jae Hyeon;Lim, Seung Pyung;Choi, Jae Sung;Na, Myung Hoon
    • Journal of Chest Surgery
    • /
    • v.47 no.3
    • /
    • pp.283-286
    • /
    • 2014
  • A 61-year-old man was diagnosed with aortic stenoinsufficiency with periannular abscess, which involved the aortic root of noncoronary sinus (NCS) that invaded down to the central fibrous body, whole membranous septum, mitral valve (MV), and tricuspid valve (TV). The open complete debridement was executed from the aortic annulus at NCS down to the central fibrous body and annulus of the MV and the TV, followed by the left ventricular outflow tract reconstruction with implantation of a mechanical aortic valve by using a leaflet of the half-folded elliptical bovine pericardial patch. Another leaflet of this patch was used for the repair of the right atrial wall with a defect and the TV.

Valve-Sparing Root Replacement in a Turner Syndrome Patient with Bicuspid Aortic Valve and Juxtacommissural Origin of the Right Coronary Artery: A Case Report

  • Son, Dong Hyeon;Cho, Sungkyu;Song, Mi Kyoung
    • Journal of Chest Surgery
    • /
    • v.55 no.5
    • /
    • pp.413-416
    • /
    • 2022
  • A 32-year-old woman diagnosed with Turner syndrome presented to the hospital for an evaluation of cardiovascular complications. Preoperative computed tomography (CT) and echocardiography showed progression of aortic root and ascending aorta dilatation, as well as a bicuspid aortic valve. There was no evidence of aortic regurgitation. We planned valve-sparing aortic root replacement and ascending aorta replacement with a high risk of aortic rupture. Intraoperatively, we incidentally found a juxtacommissural origin of the right coronary artery (RCA). We performed aortic valve reimplantation using a graft designed with a key-shaped hole to wrap the juxtacommissural-origin RCA by modifying the Florida sleeve technique. Coronary blood flow was patent on postoperative CT angiography, and there was no evidence of aortic regurgitation on postoperative echocardiography. The patient was discharged from the hospital on postoperative day 7 without any complications.

Valve-Sparing Root Replacement: Aortic Root Remodeling with External Subvalvular Ring Annuloplasty

  • Cho, Sang-Ho;Kim, Dae Hyun;Kwak, Young Tae
    • Journal of Chest Surgery
    • /
    • v.49 no.6
    • /
    • pp.489-492
    • /
    • 2016
  • The original valve-sparing procedures for aortic root aneurysms were remodeling and reimplantation of the aortic root. The remodeling technique provides more physiologic movement of the cusps within 3 reconstructed neo-sinuses, thus preserving root expansibility through the interleaflet triangles. However, the durability of remodeling has been a matter of concern due to the high rate of aortic insufficiency when annular dilation is not addressed. Therefore, a modified approach was developed, combining a physiologic remodeling of the root with a subvalvular annuloplasty. This case report highlights the first case of successful aortic root remodeling with external subvalvular ring annuloplasty in Korea.