• Title/Summary/Keyword: Anti-fire

Search Result 118, Processing Time 0.021 seconds

Analysis of Waterproof Time by Number of Twists between Ordinary Fire Hose and Anti-twist Fire Hose (일반 소방호스와 꼬임방지 소방호스의 꼬임 횟수에 따른 방수시간 분석)

  • Hong, Suk-Hwan;Kim, Seo-Young;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.23 no.4
    • /
    • pp.55-60
    • /
    • 2021
  • This study is to check waterproof by number of twists of fire hose and measure the first waterproof time to analyze the relationship between twists of fire hose and first waterproof time and waterproof by position of twists so as to suggest the efficient plan to prevent twists of fire hose. Ordinary fire hose did not make waterproof in case that position of twists was near the nozzle with twists 5 times or more, while anti-twist fire hose had no problem for waterproof only with delayed time. Like ordinary fire hose, anti-twist fire hose also showed the tendency to increase the waterproof time in proportion to the number of twists. In case that the position of twists was near waterproof port even with 10 times of twists in anti-twist fire hose, the first waterproof time was increase by 0.63 seconds on average without any problem for waterproof, which was somewhat faster than that in ordinary fire hose. With respect to the position of twists, waterproof of anti-twist fire hose was affected more as the number of twists was increased more near the nozzle rather than near the waterproof port, like ordinary fire hose. In summary, anti-twist fire hose equipped with anti-twist tool at the middle connection port and the nozzle showed a good waterproof performance with delayed waterproof time regardless of number of twists, as a solution for the twist problem of ordinary fire hose.

A Study on the Improvement of Anti-Fire System of Temples (사찰 화재예방시스템의 개선방안에 관한 연구)

  • Kong, Ha-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.87-90
    • /
    • 2008
  • This research is to study and analyze our country's management of disasters, the present condition of cultural heritages bases on the examples of temples, and Japan's safety management prevention of buddhist temple. As a result, this research aims to how to improve the temple fire prevention system. To improve the anti-fire system of temples, it is important to make new laws about fire lose to minimize cultural property lose. Secondly, to protect self-contained type fire alarm device, with aerosol type hand propelled fire extinguishers to prevent fire lose. Lastly, construction work of electric engineer is necessary to prevent temple fire loses.

A study on the implementation of digital anti-fire monitoring system with multipoint communication protocol (다중포인트 통신 프로토콜을 지원하는 디지털 화재 방지 모니터링 시스템 구현에 관한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1423-1428
    • /
    • 2012
  • In this paper, we investigated an implementation of anti-fire monitoring system based on the RS-485 communication to support local area coverage within a range of 1 Km range. We developed a Multi Point Communication Protocol supporting input/output information processing and control up to 8128 terminal check points, which provides an interface between the anti-fire monitoring system receiver and multiplex transponders. Additionally, a multiplex transponders controller has been designed for the implemented system to comply with the government regulation on fire protection, especially to monitor, report and control 1016 terminal check points within the time limit.

Analysis on the Fire Accident of Vehicle Due to Damage of Connector and wiring on an Anti-lock Brake System(ABS) Module (ABS 모듈의 접속부 및 전원배선 손상으로 인한 차량화재 사고사례 분석)

  • Park, Nam-Kyu;Kim, Jin-Pyo;Nam, Jung-Woo;Park, Jong-Taek;Song, Jae-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.13-19
    • /
    • 2017
  • In this paper, study of vehicle fire cases caused by connector and power wiring of anti-lock brake system(ABS) module damage is presented. The purpose of ABS module is to improve braking and steering ability under sudden stop of the vehicle by repeatedly activating and releasing the brake with electric signal via electric control unit. The electric control unit for ABS may experience incomplete contact between power line and signal line or electrical breakdown on the printed circuit board by undergoing repetitive signal change which would consequently result in electrical heat and spark, eventually leading to automotive fire. Therefore, the purpose of this paper is to provide fundamental data by analyzing connector and power wiring of ABS module damage conducive to the precise investigation on the cause of vehicle fire.

Comparative study on characteristics of domestic and foreign civil anti-disaster organizations (국내외 민간 방재조직의 특성에 관한 비교 분석)

  • Kim, Bo-Kyun;Lee, Jeong-Hyeok;Chae, Jong-Sik
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.127-143
    • /
    • 2021
  • Purpose: The purpose of the study is to investigate the actual state of activity on domestic and foreign civil anti-disaster organizations, related suggestions, and development plans. Methods: This study used the documentary survey research method and the technical approach method. Civil anti-disaster organizations' information was derived from detailed scholarly monographs, specialty publications, and previous studies of master doctorate dissertation. Results: Volunteer Fire Department and voluntary crime prevention groups show problems related to budgetary deficits and volunteer deficiency. In order to resolve these issues, laws must be enacted to guarantee interest and support. In addition, the Citizen Corps Active in Disaster (CAIND) organization requires a dedicated salary system to address the investment of its workforce and the cost of heavy equipment. Moreover, deficiencies were revealed regarding the lack of systems in support of occupational education and training. In conclusion, several weak points require close attention. Conclusion: The results of this comparative analysis study about the domestic and foreign civil anti-disaster organizations provide insight into identity materialization and concept establishment.

Decay Resistance and Anti-mold Efficacy of Wood Treated with Fire Retardants (난연처리 목재의 방미 및 방부성능)

  • Son, Dong Won;Kang, Mee Ran;Lee, Dong-Heub;Park, Sang-Bum
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.6
    • /
    • pp.559-565
    • /
    • 2013
  • This study evaluated the ability of white and brown rot fungi to decompose fire retardant-treated wood by measuring mass loss. Anti efficacy of FRT against sapstain and mold fungi was evaluated. Wood was treated with liquid sodium silicate and boric acid, ammonium borate, di-ammonium phosphate. Retardant treated wood was then subjected to fungal decay resistance tests performed according to KS standard method using a brown-rot fungus, Fomitopsis palustris and white rot fungus Trametes versicolor. Aspergillus niger, Penicillium funiculosum, Rhizopus nigricans, Aureobasidium pullulans, Tricoderma virede fungi were used anti-sapstain and mold test. Boron and phosphorus chemicals used in this study increased the resistance of fire retardant treated wood against both fungal attack. Anti mold and sapstain efficacy of the fire retardant treated wood was excellent but there were difference depend on mold. After the liquid sodium silicate treatment, the second chemical treatment process could lead chemical fixation into wood, which effects decay resistance.

A Study on Firing Risk Assessment of Film Manufacturing Process (필름제조 공정의 착화 위험성에 관한 연구)

  • Min, Se-Hong;Heo, Won-Il
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.107-112
    • /
    • 2011
  • We have considered the fire hazard by the static in anti-static film manufacturing factory on this study. Solvents that the flash point as ethanol, methanol and iso-propyl alcohol is low are used on the manufacturing process of anti-static film, and the minimum ignition energy of these solvents is ignited easily despite less discharge energy form 0.16 mJ to 0.65 mJ. After the static electric potential produced on each of the manufacturing plants was measured, electric potential on films of paste board is measured form 17 kV to 20 kV. But this exceeds 5 kV, which is electrifiable of objective of nonconductor for fire & explode protection. Therefore, We figure out the fire hazard was high by a static discharge in anti-static film manufacturing factory.

A Study on Ignition and Fire Risks of Electric Heat Wire (전기적 열선의 발화 및 화재 위험성에 관한 연구)

  • Min, Se-hong;Song, Byeong-jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.