• Title/Summary/Keyword: Anterior view image

Search Result 21, Processing Time 0.028 seconds

Comparison and Review of GBEF% on the Anterior and Right Lateral Images of Nuclear Hepatobiliary Scan (핵의학 간담도 스캔 시, 전면상과 우측 측면상에서의 담낭박출률에 대한 비교 및 고찰)

  • Lee, Eun-Byeol;Kim, Jae-Il;Do, Yong-Ho;Llm, Jung-Jin;Cho, Sung-Wook;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.92-96
    • /
    • 2018
  • Purpose In case of nuclear medical hepatobiliary scan, To quantitatively evaluate contractility of a gallbladder, gallbladder ejection fraction (GBEF%) is calculated from anterior images using fatty meal. However, when a gallbladder and other organs overlap on an anterior image, the gallbladder ejection fraction is not accurately evaluated. In order to reduce this error, the objective of our study was to figure out whether there is a significant difference in GBEF% calculated from the anterior and right lateral images. Materials and Methods After intravenous injection of 99mTc-Mebrofenin 370 MBq to randomly 50 patients who visited our hospital, we started to examine nuclear hepatobiliary scan. Using skylight(Philips, United States), we acquired anterior and right lateral image at 10 minutes, 20 minutes, 30 minutes, 60 minutes, 90minutes after injection. Using images at 60 and 90 minutes, gallbladder ejection fraction (GBEF%) was calculated from the anterior and right lateral images using JETstream workspace. For drawing more accurate ROI, CT images were referenced and 4 radiologists calculated the GBEF% in the same image and calculated the average value. We assessed whether there was a significant difference in GBEF% calculated from the anterior and right lateral images using SPSS program(Statistical Package for the Social Science, SPSS Ver.18 Inc. USA). Results About randomly 50 patients, the average value of the GBEF% calculated from the anterior image was 63.212 and the average value of the GBEF% calculated from the right lateral image was 62.666. GBEF% decreased 0.433% on the right lateral image compared with anterior image. Result of paired sample t-test, p value is over 0.05. So, there was no significant difference in GBEF% calculated from the anterior and right lateral images. Conclusion In the case that a gallbladder and other organs are not separated on an anteior image, Right lateral image would be better to acquire more accurate GBEF% than using anterior image.

A study on the Cochlear View in Multichannel Cochlear Implantees (인공와우 이식술 환자의 Cochlear View 촬영에 관한 연구)

  • Kweon, Dae-Cheol;Kim, Jeong-Hee;Kim, Seong-Lyong;Kim, Hae-Seong;Lee, Yong-Woo
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.27-32
    • /
    • 1999
  • Cochlear implant poses a contraindication to the magnetic resonance imaging(MRI) process, because MRI generates artifacts, inducing an electrical current and causing device magnetization. CT is relatively expensive and the metal electrodes scatter the image. Post-implantation radiological studies using anterior-posterior transorbital, submental-vertex and lateral views, the intracochlear electrodes are not well displayed. Therefore, the authors developed a special view, which we call the cochlear view. The patient is sitting in front of a vertical device. Then the midsagittal plane is adjusted to form an angle of $15^{\circ},\;30^{\circ}$, and $45^{\circ}$ with the film. The flexion of the neck is adjusted to make the infraorbitomeatal line(IOML) is parallel with the transverse axis of the film. The central ray is directed to exit from the skull at point which is 3.0 cm anterior and 2.0 cm superior to the EAM(external auditory meatus). Results have shown that single radiography of the cochlear view provides sufficient information to demonstrate the position of the electrodes array and the depth of insertion in cochlear. Radiography of the cochlear view in angle of $45^{\circ}$ is an excellent image. The cochlear view gives the greatest amount of medical information with the least radiation and lowest medical cost. It can be widely used in all cochlear implant clinics.

  • PDF

Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in 99mTc-DMSA Renal Scan (99mTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰)

  • Kim, Joo-Yeon;Lee, Han-Wool;Kwon, O-Jun;Kim, Jung-Yul;Park, Min-Soo;Cho, Seok-Won;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose $^{99m}Tc-DMSA$ renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received $^{99m}Tc-DMSA$ renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

  • PDF

A COMPARATIVE STUDY ON THE STANDARD AND INDIVIDUALLY CORRECTED RADIOGRAPHS IN TMJ TRANSCRANIAL RADIOGRAPHY (측사위 경두개 촬영시 표준사진과 개인별 수정사진의 비교연구)

  • Jung, Kyung-Yong;Lee, Ky-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.23 no.3 s.42
    • /
    • pp.405-414
    • /
    • 1993
  • Among the radiographs for temporomandibular joint, transcranial radiograph is widely used for screening and diagnosing temporomandibular disorder because it has sharp image and it is easy to take. This study was performed to compare condylar position and image sharpness in standard and individually corrected transcranial radiographs using Accurad-200 headholder. Submentovertex view, Reverse-Towne view, Standard and individually corrected transcranial radiographs of 45 university students who were randomly selected were traced, measured and analyzed. The results were as follows : 1. The means of condylar axes and lateral slopes were $16.8^{\circ}\;and\;22.5^{\circ}$ respectively. There were no differences between male and female or right and left side. 2. Individually corrected radiographs showed smaller posterior joint ,space and larger anterior joint space than standard radiographs, but superior joint space did net show a statistical difference between standard and individually corrected radiographs. 3. While a large number$(42.2\%)$ of the standard radiographs showed concentric condylar position, lots of(57.8) condylar positions were retropositioned in the individually corrected radiographs. 4. The image sharpness was inferior in the individually corrected radiographs to that of the standard radiographs.

  • PDF

Research on The Utility of Acquisition of Oblique Views of Bilateral Orbit During the Dacryoscintigraphy (눈물길 조영검사 시 양측 안 와 사위 상 획득의 유용성에 대한 연구)

  • Park, Jwa-Woo;Lee, Bum-Hee;Park, Seung-Hwan;Park, Su-Young;Jung, Chan-Wook;Ryu, Hyung-Gi;Kim, Ho-Shin
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.76-81
    • /
    • 2014
  • Purpose: Diversity and the lachrymal duct deformities and the passage inside the nasal cavity except for anterior image such as epiphora happens during the test were able to express more precisely during the dacryoscintigraphy. Also, we thought about the necessity of a method to classify the passage into the naso-lachrymal duct from epiphora. Therefore, we are to find the validity of the method to obtain both oblique views except for anterior views. Materials and Methods: The targets of this research are 78 patients with epiphora due to the blockage at the lachrymal duct from January 2013 to August 2013. Average age was $56.96{\pm}13.36$. By using a micropipette, we dropped 1-2 drops of $^{99m}TcO4^-$ of 3.7 MBq (0.1 mCi) with $10{\mu}L$ of each drop into the inferior conjunctival fold, then we performed dynamic check for 20 minutes with 20 frames of each minute. In case of we checked the passage from both eyes to nasal cavity immediately after the dynamic check, we obtained oblique view immediately. If we didn't see the passage in either side of the orbit, we obtained oblique views of the orbit after checking the frontal film in 40 minutes. The instrument we used was Pin-hole Collimator with Gamma Camera(Siemens Orbiter, Hoffman Estates, IL, USA). Results: Among the 78 patients with dacryoscintigraphy, 35 patients were confirmed with passage into the nasal cavity from the anterior view. Among those 35 patients, 15 patients were confirmed with passage into the nasal cavity on both eyes, and it was able to observe better passage patterns through oblique view with a result of 8 on both eyes, 2 on left eye, and 1 on right eye. 20 patients had passage in left eye or right eye, among those patients 10 patients showed clear passage compared to the anterior view. 13 patients had possible passage, and 30 patients had no proof of motion of the tracer. To sum up, 21 patients (60%) among 35 patients showed clear pattern of passage with additional oblique views compared to anterior view. People responded obtaining oblique views though 5 points scale about the utility of passage identification helps make diagnoses the passage, passage delayed, and blockage of naso-lachrymal duct by showing the well-seen portions from anterior view. Also, when classifying passage to naso-lachrymal duct and flow to the skin, oblique views has higher chance of classification in case of epiphora (anterior:$4.14{\pm}0.3$, oblique:$4.55{\pm}0.4$). Conclusion: It is considered that if you obtain oblique views of the bilateral orbits in addition to anterior view during the dacryoscintigraphy, the ability of diagnose for reading will become higher because you will be able to see the areas that you could not observe from the anterior view so that you can see if it emitted after the naso-lachrymal duct and the flow of epiphora on the skin.

  • PDF

A RADIOGRAPHIC STUDY ON THE MUCOSAL CYST OF THE MAXILLARY SINUS (상악동 점액성 낭에 관한 방사선학적 연구)

  • Park Eung-Chun;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.23 no.2
    • /
    • pp.277-285
    • /
    • 1993
  • This study was performed to evaluate the role of Waters' view and panoramic view for the interpretation of mucosal cyst of the maxillary sinus and to determine the radiographic features of that according to the sites and sizes. For this study, clinically 25 cases of mucosal cyst of the maxillary sinus were used, and experimentally with two dry skulls, rubber ball of 15mm in diameter for marked radiopacity, and two jelly balls of 8 and 20㎜ in diameter for the similar radiopacity to cyst were used. The 25 cases with 25 panoramic views and 15 Waters' views were first analyzed, and secondly, the radiographic features of artificial lesions attached to the each wall of the antrum on Waters' view and panoramic view were analyzed. The obtained results were as follows: At clinical analysis, 1. 4 cases of 13-14㎜, 4 cases of 15-19mm, 14 cases of 20-25㎜, 3 cases of over 30㎜ in dia- meter were found on panoramic views. And 24 cases of 25 cases showed no relationship with teeth, and only 1 case was associated with advanced periodontal disease 2. The majority of mucosal cysts appeared to arise the posterior portion of the floor of the sinus and were superimposed with the inominate line of zygoma and the horizontally linear image of hard palate on panoramic view. 3. Only 2 cases of 15 cases were identified on both films. At experimental analysis, 4. On Waters' view, the images of the artificial lesion of the anterior portion and midportion of the floor of the sinus were lessend in diameter compared with the real size. On panoramic views, the images of the lesion were more radiolucent with lessened diameter than images on Water' view. 5. The images of the lesion of the posterior wall and the posterior portion of the floor of sinus on panoramic view were well detected by the preeducated group but not or poorly detected by the non-preeducated observer group. 6. On Waters' view, both observer groups recognized that the cystic images of the posterior portion of the floor of the maxillary sinus were superimposed with the petrous portion of the skull.

  • PDF

A RADIOGRAPHIC STUDY ON THE MORPHOLOGY OF THE MAXILLARY SINUS (상악동의 형태에 관한 방사선학적 연구)

  • Kim Bong-Young;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.297-306
    • /
    • 1991
  • The purpose of this study is to improve the availabilities of radiographic technics as diagnostic methods to evaluate maxillary sinus in dental clinic. For the morphologic study of maxillary sinus, 20 dry maxillas were used and intraoral standard views, orthopantomograms, and skull P-A views were taken. For measuring the vertical image magnification rates, 5 sites in maxillary molar regions of 5 dry mandibles were selected radndomly and 25 wires of the determined sizes for selected portions were attached to the sites, after then, intraoral radiograms with bisecting technic and orthopantomograms were taken. The acquired results were as follows: 1. The anterior extension of the maxillary sinus on orthopantomogram was the distal side of the canine in 45.45% of subjects, the mesial side of the canine in 27.27%, the lateral incisor in 9.09%, the mesial side of the 1st premolar in 9.09%, and the mesial side of the 2nd pre-molar in 9.09%. 2. The positional relationship between the floor of maxillary sinus and the apex of alveolar socket revealed superimposed type in 58.3% of subjects, approached type in 33.3%, and separated type in 8.4%. 3. The morphology of inferior border of maxillary sinus was simple V or U shape in edentulous stage and V or wide U shape in alveolar socket stage. 4. The vertical image length on intraoral film taken by bisecting technic was magnified by 27.23% on the average and the length on orthopantomogram by 12.35%. 5. The inferior borders of maxillary sinus coinciding with each of the areas bearing the anterior and the posterior teeth on skull P-A view were determined.

  • PDF

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

Influence of tooth position within the field of view on the intensity of cone-beam computed tomographic imaging artifacts when assessing teeth restored with various intracanal materials

  • de Oliveira Pinto, Martina Gerlane;Melo, Saulo Leonardo Sousa;Cavalcanti, Yuri Wanderley;de Lima, Elisa Diniz;Bento, Patricia Meira;de Melo, Daniela Pita
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.141-151
    • /
    • 2020
  • Purpose: This study aimed to quantify the influence of tooth position within the field-of-view (FOV) on cone-beam computed tomography (CBCT) imaging artifacts' intensity when assessing teeth restored with various intracanal materials. Materials and Methods: Seventy single-rooted teeth were divided into 7 groups (10 teeth per group): NiCr post (NC), AgPd post (AP), metal core fiberglass post (MCFG), fiberglass post (FG), anatomical fiberglass post (AFG), fiberglass post cemented with core build-up cement (FGCo), and anatomical fiberglass post cemented with core build-up cement (AFGCo). All posts were cemented using a regular dual-curing resin cement (Allcem), except FGCo and AFGCo which were cemented with a core build-up dual-curing resin cement (AllcemCore). Each tooth was scanned on a CS9000 in 5 positions within the FOV: a central position, anterior horizontal peripheral, peripheral superior, peripheral inferior, and posterior horizontal peripheral position. Hyperdense, hypodense, remaining teeth areas and ROI areas were quantitatively analyzed using ImageJ software. Results: Posterior horizontal peripheral position increased the intensity of artifacts on FGCo and AFGCo post groups (P<0.05), and specifically the hypodense artifact intensity on FG and AFG post groups (P<0.05). NC and AP groups presented greater intensity of artifacts than any other post groups(P<0.05). Conclusion: Artifact intensity increases in the presence of high atomic number materials and when the object is not centered within the FOV. The impact of positioning within the FOV on artifact was greater for fiberglass posts cemented with core build-up dual-curing cement than for metal posts and fiberglass posts cemented with regular dual-curing cement.