• Title/Summary/Keyword: Anterior cruciate ligament (ACL) reconstruction

Search Result 164, Processing Time 0.025 seconds

Two to Four Year Follow-Up Results after Anterior Cruciate Ligament Reconstruction Using Transtibial Femoral Tunnel at 10 or 2 O'clock Position (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 후 2~4년 추시 결과)

  • Cho, Sung-Do;Youm, Yoon-Seok;Jeong, Ji-Young;Park, Han-Chang
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.1-7
    • /
    • 2009
  • Purpose: To evaluate the 2 to 4-year follow-up results after arthroscopic anterior cruciate ligament (ACL) reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position. Materials and Methods: Eighty-six ACL reconstructions could be evaluated. Evaluations included 2000 International Knee Documentation Committee (IKDC) subjective knee score, Lachman test, Pivot-shift test, KT-1000 arthrometer measurement, 2000 IKDC knee examination and second-look arthroscopy. Results: Seventy-five patients (87.2%) had over 80 in 2000 IKDC subjective knee score. Eighty-three patients (96.5%) had 1+firm end or negative Lachmann test. Seventy-eight patients (90.7%) had a negative Pivot-shift test. Eighty-three patients (96.5%) had less than 5 mm difference by KT-1000 arthrometer. Eighty patients (93.0%) were normal or nearly normal by 2000 IKDC knee examination. Second-look arthroscopy was done in fifteen cases. Nine cases showed good synovialization, four cases showed partial synovialization, two cases showed poor synovialization and graft failure was noted in one case. Conclusion: ACL reconstruction using transtibial femoral tunnel at 10 or 2 O'clock position resulted in a good outcome in terms of rotatory stability as well as antero-posterior stability.

  • PDF

Effects of Knee Position during the Graft Fixation of the Arthroscopic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Graft (이식 건 고정 시 슬관절 위치가 자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 후 결과에 미치는 영향)

  • Lee, Churl-Woo;Yoo, Jae-Doo;Roh, Kwon-Jae;Park, Seong-Pil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.143-147
    • /
    • 2005
  • Purpose: In case of anterior cruciate ligament (ACL) reconstruction, graft tendon is generally fixed in tibial tunnel with knee extended. When reconstructing ACL using hamstring tendon, the authors aim to find out the effect of knee joint position during graft fixation on postoperative knee joint stability and range of motion. Materials and Methods: Prospective study was done on patients who have undergone ACL reconstruction using hamstring tendon from May 2002 to January 2003 We used Rigifix system (Mitek Product, Johnson and Johnson, USA) and Intrafix system for fixation. Thirty nine patients received ACL reconstruction during this period. Excluding 2 patients lost in the follow-up, 37 patients were analyzed. The mean follow-up period was 14 months $(13{\sim}25months)$. Knee position was decided alternatively without any bias. Clinical evaluation was based on Lachman test, pivot shift test, Lysholm score, IKDC(international knee documentation committee) assessment and side to side KT-1000 maximal manual arthrometer difference. Results: After the last follow-up, average postoperative Lysholm score was 93.1 poins(65-98points). According to IKDC score, 26 cases were normal, 10 cases were nearly normal, 1 case was abnormal and we had no case of severe abnormality. The mean difference from the normal side was 2.5 mm under maximal manual loading KT-1000 arthrometer. According to postoperative Lachman test, 32 cases were normal,2 cases were grade I and 1 case was grade II. There were 34 cases of normal, 2 cases of grade I and 1 case of grade II. When using maximal manual KT-1000 arthrometer side to side difference, the difference from the normal side while fixing the tibia at 20'knee flexion was 2.3 mm and at full extention the difference was 2.7 mm. The range of motion at postoperative 1 year showed 5 degree flexion contracture in 1 case at 20 degrees knee flexion and 10 degrees of flexion limitation was observed in 2 cases at full extension. Conclusion: When ACL reconstruction using autogenous hamstring tendon, anterior laxity showed no difference in its stability between two groups. Tibial side fixation at full extension may be helpful in preventing flexion contracture due to overconstrained graft tendon.

  • PDF

Arthroscopically Assited Reconstruction of the Anterior Cruciate Ligament using the Flexible Reamer (유연성 연마기를 이용한 관절경적 전방 십자 인대 재건술)

  • Lee Seoung-Joon;Park Jung-Ho;Chae In-Jung
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.176-182
    • /
    • 2003
  • Purpose : The purpose of this study is to describe the surgical technique of ACL reconstruction with the flexible reamer and evaluate the clinical results of this method. Materials and Methods : Twenty four patients who followed for 12 months were included. The results were evaluated by Lachman test, KT-2000 arthrometer, Lysholm score, and postoperative roentgenogram of the knee. Results : The range of motion of the affected knee was acceptable except one case(10 to 90 degree) and at the last follow up, two cases were positive in Lachman test. Mean Lysholm knee scoring scale was 63.7 point preoperatively and 91.4 point at the last follow up. The results of KT-2000 arthrometer was 6.6mm preoperatively and 1.5mm at the last follow up. In operative time, there were decrease of mean 13.5 minute than ACL reconstruction without the flexible reamer, Conclusion : ACL reconstruction with the flexible reamer achieves the ideal isometric point of tibia and femur with no difficulty, proper notchplasty preventing from the impingement, and lessens the operative time.

  • PDF

Notchyplasty with Flexible Reamer (대퇴과간절흔 성형술에서 유연성 연마기를 이용한 방법)

  • Chae, In-Jung;Lee, Kwang-Suk;Back, Jong-Ryoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.123-127
    • /
    • 1997
  • Arthroscopic anterior cruciate ligament reconstructions using bone-patella tendon-bone have been considered the best method by which others are compared. The notchyplasty is one of the important steps of this procedure and it is emphasized recently to prevent retear of the reconstructed ACL caused by impingement. However, until now, there is controversy about adequate amount of notchyplasty. Also, it is hard to examine the adequacy of notchyplasty even in the arthroscopic field, The purpose of this paper is to describe the surgical technique of notchyplasty, using the flexible reamer and preliminary result of its operation. In this study the results of ACL reconstruction with notchyplasty which is made by us were analized from January. 1994 to December, 1995. The results were as follows: 1. The notchyplasty with flexible reamer is the method that can be obtained adequate amount of removal, perfectly smooth notchyplasty. 2. The range of motion of the affected knee joint was normal ROM after post operation 6 month. 3. In the last follow up, 2 cases were positive in anterior drawer test 4 cases were positive in Lachmann's test and 1 knee was positive in Pivot shift test 4. Average Lysholm knee scoring scale was 70 points at preoperative and 92 points at the last follow up.

  • PDF

ACL Reconstruction with Hamstring Tendon and LA (Ligament anchor) Screw (슬괵건과 LA나사를 이용한 관절경적 전방 십자 인대 재건술)

  • Song Eun-Kyoo;Seon Jong-Keun;Cho Sang-Gwon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.189-195
    • /
    • 2003
  • Purpose : To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw Materials and Methods : 103 patients (104 cases) who were followed up at least more than 2 years after ACL reconstruction were included in this study. The average period of follow-up was 36 months. The clinical results such as physical examination and Lysholm knee score and instrumented anterior laxity test with Telos were evaluated. Results : The Lysholm knee score was 57.9 in average preoeratively and improved to 95.2 in average at follow up. On the Lachman test, there were mild (+) instability in 46 cases $(45\%)$, moderate (++) in 33 $(31\%)$, severe (+++) in 25 $(24\%)$ preoperatively. 90 cases $(87\%)$ were converted to negative and 14 $(13\%)$ to mild at follow up. On Pivot-shift test, there were negative (-) instability in 22 cases $(22\%)$, mild (+) in 62 $(59\%)$, moderate (++) in 12 $(11\%)$ and severe in 8 $(8\%)$ preoperatively. 87 cases $(84\%)$ were converted to negative and 17 $(16\%)$ to mild at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference on 20 lb was $13.4{\pm}5.6$ (7-25) mm in average preoperatively, and was decreased to $3.6{\pm}1.5$ (1-6) mm in average at follow-up. Complications were quadriceps muscle atrophy in 27 $(30.0\%)$, saphenous nerve paresthesia in 19 $(18.3\%)$, anterior knee crepitus in 13 $(12.5\%)$ and over-penetration of screw through lateral femoral cortex in 5 cases $(4.8\%)$. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of graft and fixatives in restoring knee stability and in improving clinical results with little complications such as anterior knee pain.

  • PDF

Comparison of Primary Stability of Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전 십자 인대 재건술에서 대퇴골측 고정 방법의 초기 안정성의 비교)

  • Song, Eun-Kyoo;Lee, Keun-Bae;Lee, Moon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.85-92
    • /
    • 1998
  • Various methods for fixation of graft have been widely used for reconstruction of anterior cruciate ligament. However, the biomechanical strength of each fixation techniques are not fully understood. The purpose of this study is to compare the pull out strength of different fixation techniques which is probably the most important factor for the success at the initial stage of healing. Biomechanical test was carried out to measure and compare the pull out tensile strength of five different fixation techniques in 35 pig(Yorkshire) knees. ANOVA and Duncan multiple comparison test was applied for statistical analysis. In the two fixation techniques with bone patellar tendon bone graft, the mean maximum tensile strength was $1333.4{\pm}148.5N$ with titanium interference screw, while it was $1310.1{\pm}168.9N$ with biodegradable interference screw. The failure mode were pulled out of bone plugs from the femoral tunnel in majority cases. In the fixations with hamstring tendon, the mean maximum tensile strength were $1405.9{\pm}135.1N$ with SemiFix screw, $820.3{\pm}104.5N$ with biodegradable interference screw, and $682.1{\pm}54.2N$ with Endobutton. The mode of failure was variable in each technique. The tendon was pulled out from the tunnel in biodegradable interference screw fixation, the screw was bent in the SemiFix system, and the polyester tape were ruptured or the buttons were pulled into tunnel in Endobutton fixation. The mean maximum tensile strength of two interference screws with bone patellar tendon bone was statistically comparable to that of SemiFix with hamstring tendon. However biodegradable interference screw and Endobutton with hamstring tendon showed weaker maximum tensile strength than above three fixation techniques (P<0.05).

  • PDF

Tibial Tunnel Enlargement following Arthroscopic ACL Reconstruction (관절경하 전방십자인대 재건술 후 경골 터널 크기 변화)

  • Lee, Kwang-Won;Lee, Byeong-Ki;Ryu, Chang-Soo;Keum, Teok-Seop;Choy, Won-Sik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.114-118
    • /
    • 1998
  • We retrospectively evaluated the changes in the diameter of the tibial tunnel over time following the reconstruction of the anterior cruciate ligament with a bone-patella tendon-bone(BPTB) autograft(25 cases) and quadruple semitendinosus(ST) graft(27 cases) in 52 patients at one year postoperatively. The changes in the geometry of the bony tunnel were measured with radiography. The demensions at final follow up were correated with the clinical results. An increased width of the tibial tunnel was noted in all cases. On the femoral side, however, no tunnel expansion was noted. In AP view, the average tibial tunnel enlargement in ST and BPTB graft groups were 1.30mm(13%) and 1.82mm(17%), respectively. In lateral view, the average tibial tunnel enlargement in ST and BPTB graft group was 1.30mm(13%) and 2.04mm(19%). The differences between two groups were not statistically significant, however, there was evidence of a borderline significance(P=0.0502). Although the tunnel enlargement does not appear to adversely affect the clinical outcome in the short term, the exact mechanism which are involved should be demonstrated. Furthermore histologic study is needed to evaluate graft replacements with emphasis on the graft-tunnel interface.

  • PDF

The Effectiveness of the IKDC Subjective Score in Clinical Outcome Study after Anterior Cruciate Ligament Reconstruction (전방 십자 인대 재건술 후 결과 판정에 있어 IKDC 주관적 점수의 유용성)

  • Kim, Ji-Yeong;Kim, Deuk-Won;Kim, Jin-Goo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.7 no.2
    • /
    • pp.95-121
    • /
    • 2008
  • Purpose: The goal is to identify the effectiveness of the IKDC subjective score in the clinical outcome study after reconstruction of the anterior cruciate ligament. Materials and Methods: Twenty-four patients after ACL reconstructions using twelve hamstring autografts and twelve Achilles allografts were evaluated. Lysholm knee score, IKDC subjective score, Knee Outcome Survey score and Tegner activity score were evaluated for the subjective outcome value. Static instability tests, Biodex dynamometer and one-legged hop for distance tests were done for the objective outcome value. Three functional performance tests (FPTs) including Carioca test, Shuttle run test and Co-contraction test were performed for deciding the final results. Each scale was compared with FPTs results and Pearson's correlation test was used to test the correlation between the parameters. Results: IKDC subjective score, single hop test, and quadriceps power in low velocity of Biodex dynamometer tests had a positive correlation with the total FPTs results. Conclusion: IKDC subjective score can be an effective test to evaluate the functional status as well as the subjective outcome after ACL reconstruction.

  • PDF

The effectiveness of MRI evaluation after anterior cruciate ligament reconstruction using hamstring tendon autograft (자가 슬괵건을 이용한 전방십자인대 재건술 후 결과 판정에 있어 MRI 검사의 유용성)

  • Kim, Jin-Goo;Kim, Young-Woo;Lee, Soo-Won;Shim, Jae-Chan;Oh, Soo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.32-39
    • /
    • 2008
  • Purpose: To evaluate the effectiveness of MRI after ACL reconstruction with femoral tunnel at 10 o'clock position. Materials and Methods: MRI findings of 29 patients after ACL reconstruction using hamstring tendon autograft were evaluated. The mean period from operation to MRI was 18.9 months($7{\sim}40$ months). Signal intensity, morphology and continuity of graft, femoral insertion, graft angle, roof impingement, cross pin breakage and position were evaluated. Those findings were compared with KT-2000, Lysholm knee score and pivot shift test. Results: There was no significant correlation between signal intensity of graft and the duration to MRI. Most common pattern of the morphology was straight, and the continuity was well-preserved. 13 cases of femoral tunnel insertion were zone 4 and 16 were zone 3. There were no roof impingement. 10 cases showed cross pin breakages, of which 5 were found at the outside of distal femoral posterior cortex. 9 showed cross pin directed posteriorly in axial view. There was no significant correlation between clinical results and cross pin breakage. Conclusion: MRI examinations after ACL reconstructions are useful to evaluate the graft status, position of the graft and cross pins. Since the direction of the cross pin is important especially in 10 o'clock femoral position, care should be taken to avoid cross pin breakage.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF