Jain, Vaibhav;Madan, Ankit;Thakur, Manoj;Thakur, Amit
Neurospine
/
제15권4호
/
pp.368-375
/
2018
Objective: To evaluate the results of operative management of subaxial spine injuries managed with 2-level anterior cervical corpectomy and fusion with a cervical locking plate and autologous bone-filled titanium mesh cage. Methods: This study included 23 patients with a subaxial spine injury who matched the inclusion criteria, underwent 2-level anterior cervical corpectomy and fusion at our institution between 2013 and 2016, and were followed up for neurological recovery, axial pain, fusion, pseudarthrosis, and implant failure. Results: According to Allen and Ferguson classification, there were 9 cases of distractive extension; 4 of compressive extension; 3 each of compressive flexion, vertical compression, and distractive flexion; and 1 of lateral flexion. Sixteen patients had a score of 6 on the Subaxial Injury Classification system, and the rest had a score of more than 6. The mean follow-up period was 19 months (range, 12-48 months). Neurological recovery was observed in most of the patients (78.21%). All patients experienced relief of axial pain. None of the patients received a blood transfusion. Twenty-one patients (91.3%) showed solid fusion and 2 (8.69%) showed possible pseudarthrosis, with no complications related to the cage or plate. Conclusion: Two-level anterior cervical corpectomy and fusion, along with stabilization with a cervical locking plate and autologous bone graft-filled titanium mesh cage, can be considered a feasible and safe method for treating specific subaxial spine injuries, with the benefits of high primary stability, anatomical reduction, and direct decompression of the spinal cord.
Zhang, Ho-Yeol;Thongtrangan, Issada;Le, Hoang;Park, Jon;Kim, Daniel H.
Journal of Korean Neurosurgical Society
/
제38권6호
/
pp.435-441
/
2005
Objective : Expandable cage used for spinal reconstruction after corpectomy has several advantages over nonexpendable cages. Here we present our clinical experience with the use of this cage after anterior column corpectomy with an average of one year follow up. Methods : Ten patients underwent expandable cage reconstruction of the anterior column after single-level or multilevel corpectomy for various cervical spinal disorders. Anterior plating with or without additional posterior instrumentation were performed in all patients. Functional outcomes, complications, and radiographic outcomes were determined. Results : There was no cage-related complication. Functionally, neurological examination revealed improvement in 7 of 10 patients and no patient had neurological deterioration after the surgery. Immediate stability was achieved and maintained throughout the period of follow-up. There was minimal subsidence [<2mm] noticeable in three of the cases that underwent a two-level corpectomy. Subsidence was noted in osteoporotic patients and patients undergoing multi-level corpectomies. Average pre-operative kyphotic angle was 9 degrees. This was corrected to an average of 5.4 degrees in lordosis postoperatively. Conclusion : In conclusion, expandable cages are safe and effective devices for vertebral body replacement after cervical corpectomy when used in combination with anterior plating with or without additional posterior stabilization. The advantages of using expandable cages include its ability to easily accommodate itself into the corpectomy defect, its ability to tightly purchase into the end plates after expansion and thus minimizing the potential for migration, and finally, its ability to correct kyphosis deformity via its in vivo expansion properties.
Direct anterior approach for lesions located anterior to the thecal sac is definitely superior to lateral or posterior approach in many respects. However, various anatomical obstacles and technical difficulties often hinder direct anterior approach. Thanks to ripe experience of retroperitoneal approach to the lumbar spine for anterior lumbar interbody fusion and total disc replacement, the authors could perform lumbar corpectomy and reconstruction by using midline retroperitoneal approach recently. During this approach, we repaired anterior longitudinal ligament also to reduce the risk of graft extrusion and to prevent erosion of vascular wall due to direct contact between metallic hardware, which was used for reconstruction of vertebral body, and major vessels.
Objective : Anterior cervical corpectomy with fusion (ACF) or laminoplasty may be associated with substantial number of complications for treating multilevel cervical ossification of the posterior longitudinal ligament (OPLL) with significant cord compression. For more safe decompression and stabilization in multilevel cervical OPLL with prominent cord compression, we propose circumferential cervical surgery (selective ACF and laminoplasty) based on our favorable experience. Methods : Twelve patients with cervical myelopathy underwent circumferential cervical surgery and all patients showed multilevel OPLL with Signal change of the spinal cord on magnetic resonance imaging (MRI). A retrospective review of clinical, radiological. and surgical data was conducted. Results : There were 9 men and 3 women with mean age of 56.7 years and a mean follow up period of 15.6 months. The average corpectomy level was 1.16 and laminoplasty level was 4.58. The average Japanese Orthopedic Association score for recovery was 5.1 points and good clinical results were obtained in 11 patients (92%) (p < 0.05). The average space available for the cord improved from 58.2% to 87.9% and the average Cobb's angle changed from 7.63 to 12.27 at 6 months after operation without failure of fusion (p < 0.05). Average operation time was 8.36 hours, with an estimated blood loss of 760 mL and duration of bed rest of 2.0 days. There were no incidences of significant surgical complications, including wound infection. Conclusion : Although the current study examined a small sample with relatively short-term follow-up periods, our study results demonstrate that circumferential cervical surgery is considered favorable for safety and effectiveness in multilevel OPLL with prominent cord compression.
Zidan, Ihab;Khedr, Wael;Fayed, Ahmed Abdelaziz;Farhoud, Ahmed
Journal of Korean Neurosurgical Society
/
제62권1호
/
pp.61-70
/
2019
Objective : Corpectomy of the first lumbar vertebra (L1) for the management of different L1 pathologies can be performed using either an anterior or posterior approach. The aim of this study was to evaluate the usefulness of a retroperitoneal extrapleural approach through the twelfth rib for performing L1 corpectomy. Methods : Thirty consecutive patients underwent L1 corpectomy between 2010 and 2016. The retroperitoneal extrapleural approach through the 12th rib was used in all cases to perform single-stage anterior L1 corpectomy, reconstruction and anterior instrumentation, except for in two recurrent cases in which posterior fixation was added. Visual analogue scale (VAS) was used for pain intensity measurement and ASIA impairment scale for neurological assessment. The mean follow-up period was 14.5 months. Results : The sample included 18 males and 12 females, and the mean age was 40.3 years. Twenty patients (67%) had sensory or motor deficits before the surgery. The pathologies encountered included traumatic fracture in 12 cases, osteoporotic fracture in four cases, tumor in eight cases and spinal infection in the remaining six cases. The surgeries were performed from the left side, except in two cases. There was significant improvement of back pain and radicular pain as recorded by VAS. One patient exhibited postoperative neurological deterioration due to bone graft dislodgement. All patients with deficits at least partially improved after the surgery. During the follow-up, no hardware failures or losses of correction were detected. Conclusion : The retroperitoneal extrapleural approach through the 12th rib is a feasible approach for L1 corpectomy that can combine adequate decompression of the dural sac with effective biomechanical restoration of the compromised anterior loadbearing column. It is associated with less pulmonary complication, no need for chest tube, no abdominal distention and rapid recovery compared with other approaches.
Kim, Min-Ki;Kim, Sung-Min;Jeon, Kwang-Mo;Kim, Tae-Sung
Journal of Korean Neurosurgical Society
/
제51권3호
/
pp.135-140
/
2012
Objective : To evaluate radiographic results of anterior fusion methods in two-level cervical disc disease : tricortical autograft and plate fixation (ACDF-AP), cage and plate fixation (ACDF-CP), stand-alone cage (ACDF-CA), and corpectomy and plate fixation (ACCF). Methods: The numbers of patients were 70 with a minimum 6 month follow-up (ACDF-AP : 12, ACDF-CP : 27, ACDF-CA : 15, and ACCF : 16). Dynamic simple X-ray and computed tomography were evaluated preoperatively, postoperatively, 6 month, and at the final follow-up. The fusion and subsidence rates at the final were determined, and global cervical lordosis (GCL), cervical range of motion, fused segment angle (FSA), and fused segment height (FSH) were analyzed. Results: Nonunion was observed in 4 (25%) patients with ACDF-CA, 1 (8%) patient with ACDF-AP, 1 (4%) patient with ACDF-CP. The number of loss of FSH (%) more than 3 mm were 2 patients (16%) in ACDF-AP, 3 patients (11%) in ACDF-CP, 5 patients (33%) in ACDF-CA, and 3 patients (20%) in ACCF. The GCL was decreased with ACDF-CA and increased with others. The FSA was increased with ACDF-AP, ACDF-CP, and ACCF, but ACDF-CA was decreased. At the final follow-up, the FSH was slightly decreased in ACDF-CP, ACDF-AP, and ACCF, but ACDF-CA was more decreased. Graft related complication were minimal. Screw loosening, plate fracture, cage subsidence and migration were not identified. Conclusion: ACDF-CP demonstrated a higher fusion rate and less minimal FSH loss than the other fusions in two-level cervical disc disease. The ACDF-AP and ACCF methods had a better outcome than the ACDF-CA with respect to GCL, FSA, and FSH.
Objective : In a variety of thoracolumbar diseases, corpectomy followed by interbody bone graft and anterior instrumentation has allowed direct neural decompression and reconstruction of the weight-bearing column by short segments fusion. In this study, we compared spinal stability of the two different anterior thoracolumbar instruments : Z-plate and Kaneda device representing plate and two-rods type, respectively. Methods : A retrospective review was performed for all the patients with thoracolumbar diseases or traumas treated with anterior corpectomy, autologous iliac bone graft, and fixation with instruments from 1996 to 2000. For the anterior instrumentation, Z-plate or Kaneda device was used for 24 [M:F=5:9, average age=37] and 12 [M:F=9:3, average age=41] patients, respectively. The plain AP and lateral flexion-extension films were taken immediately after surgery and at each follow-up. The sagittal and coronal Cobb's angles at the operation segments were used to observe the change of initial fixation status. The surgical time length and bleeding amount of the two groups were compared. Intra-operative and post-operative instrument associated complications were evaluated. Student t-test was used for statistical analysis and p-value less than 0.05 was considered to be significant. Results : Mean follow-up durations for Z-plate and Kaneda device were 24 and 21 months, respectively. The fusion rate was 91% for Z-plate and 100% for Kaneda device. Two cases of Z-plate group showed instrumentation failure during the follow up period, in which additional surgery was necessary. The mean differences of sagittal Cobb's angles among the AP images immediate after surgery and at follow-up were 7 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. The mean differences of coronal Cobb's angles were 5 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. No Intra-operative complication has occurred in both groups. There was no difference in surgery time and bleeding amount between two groups. Conclusion : We think that Kaneda device [rod type] is stronger than Z-plate [plate type] to keep the spinal stability after anterior thoracolumbar surgery.
We present a case of delayed oral extrusion of a screw after anterior cervical interbody fusion in a 68-year-old man with osteoporosis. Fifteen months earlier, he had undergone C5 corpectomy and anterior cervical interbody fusion at C4-6 for multiple spinal stenoses. The patient was nearly asymptomatic, except for a foreign body sensation in his throat. We conclude that the use of a mesh graft or other instrument in elderly patients and those with osteoporosis or problematic bone quality should be considered carefully and that if surgery were to be performed, periodic postoperative follow-up evaluations are mandatory.
Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.
Objective : To investigate the prognostic factors associated with outcome in patients with ossification of posterior longitudinal ligament. Method : During the past 4 years, we have operated on 35 patients with cervical OPLL. Anterior cervical decompression(total or subtotal corpectomy, discectomy, and removal of the OPLL) and interbody fusion with iliac bone were performed in all patients. Results : Eight cases(22.9%) were continuous type, 11(31.4%) segmental, 13(37.1%) Mixed, and 3(8.6%) localized type. Thirty-two patients(91.4%) showed an excellent or good results. Conclusion : These results indicate that surgical treatment should be considerated in case of clinical grading higher than II and the surgical outcome is worse when duration of preoperative symptom is longer and when percentage of spinal narrowing is higher. Anterior cervical decompression and interbody fusion seems to be a better method in patients with lesions limited to one or two level. Age at surgery did not significantly affect the outcom.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.