• Title/Summary/Keyword: Anterior cervical fusion

Search Result 110, Processing Time 0.021 seconds

Analysis of Noninstrumented Anterior Cervical Discectomy and Interbody Fusion in Degenerative Cervical Disease (퇴행성 경추질환에서 전방경유 추간판 절제술 및 골유합술의 결과분석)

  • Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.180-185
    • /
    • 2001
  • Objectives : We retrospectively studied the efficacy of anterior cervical discectomy and interbody fusion without plate fixation in degenerative cervical disease. Methods : Thirty two consecutive patients with degenerative cervical disease treated by decompression and interbody fusion(Smith-Robinson technique) without anterior cervical plating were studied for postoperative complication rate as well as the clinical and radiologic outcomes and were compared the result of ours with other reported series where the anterior cervical plating was used. Results : All cases were reviewed after average period of 13 months for the purpose of this study. There were 4 postoperative complications related to grafting. A solid fusion was obtained in all cases with single-level fusion(n=21) and 81.8 % of the cases with a two-level fusion(n=11). The overall fusion rate was 93.8 % and fusion rate per level fused was 95.3%. The clinical outcome of the patients was comparable with that in the literature, with one patient having a poor result. Comparing the result of this study with others of the anterior cervical plating, clinical outcome and fusion rate were not superior in plate fixation group in single-level fusion, but increased fusion rate and decreased graft-related complication rate were noted in multilevel fusion with plate fixation. However, the clinical outcome was not superior to noninstrumented fusion group of this study. Conclusion : These results demonstrate that anterior cervical discectomy and interbody fusion(Smith-Robinson technique) without instrumentation is safe and reliable method of single-level fusion in degenerative cervical disease. Plate fixation system doesn't seem necessary in single level fusion in degenerative cervical disease.

  • PDF

Outcome Analysis of the Patients with and without Anterior Plating in Multi-Level Degenerative Cervical Diseases (다분절 퇴행성 경추질환에서의 전방 금속판 사용 유무에 따른 환자의 예후분석)

  • Kim, Sang Woo;Kim, Sung Min;Shin, Dong Ik;Cho, Yong Jun;Shim, Young Bo;Choi, Sun Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1369-1374
    • /
    • 2001
  • Objectives : The rates of pseudarthrosis for two- and three level fusion have been reported to be 17-63 and 50% without anterior cervical plating. The purpose of this study is to assess the effects of anterior cervical plating in the treatment of multilevel degenerative cervical disease such mostly the additional risks associated with hardware implants and its benefits, fusion rate and radiographic results, and clinical outcomes. Methods : Forty-seven patients who underwent operations between 1993 and 1997 were retrospectively reviewed. The technique for operation was same for both groups(Smith Robinson with autologous iliac bone graft). Group I consisted of 35 consecutive patients treated with anterior cervical decompression and fusion with anterior cervical plate fixation. Group II consisted of 12 consecutive patients treated without plate fixation. We compared clinical outcomes by Prolo score, radiographic results in the rate of fusion, cervical lordosis by Gore angle, disc height by Farfan method, and surgical complications between two groups. Results : The favorable clinical outcomes(excellent and good) by Prolo score were observed with the use of anterior cervical plate fixation(89% vs 75%). The successful fusion rate of multilevel cervical fusion was as seen with anterior cervical plate fixation(97% vs 75%). The overall graft complication rate in multilevel fusions was decreased, with anterior cervical plate fixation, and the hardware related complications were relatively minimal without serious consequences. Conclusion : Anterior cervical plate fixation in the treatment of multilevel cervical disorders is an effective stabilizing method which provides increased bony fusion rate, decreased graft complications, maintained cervical lordosis, early mobilization of the these patients without serious hardware related complications.

  • PDF

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Esophageal Fistula Related to Anterior Cervical Spine Surgery after Severe Cervical Trauma (심한 경추부 외상후에 전방 경추부 수술후 발생한 식도의 누공)

  • Paeng, Sung Hwa
    • Journal of Trauma and Injury
    • /
    • v.25 no.4
    • /
    • pp.278-282
    • /
    • 2012
  • An esophageal perforation following anterior cervical fusion is rare. Early development of an esophageal perforation after anterior cervical fusion is usually due to iatrogenic injury from retraction, injury associated with the original traumatic incident, improperly placed instruments or a bone graft. A 31-year-old man had a cervical dislocation and spinal cord injury because of severe cervical trauma after a traffic accident. He was quadriplegic and had no feeling below T4 dermatome. Anterior decompression of the cervical spine and anterior fusion with mesh with autobone were performed. An esophagocutaneous fistula occurred 7 days after anterior cervical surgery. A second anterior surgery was done because of pus drainage. The mesh was changed with an iliac bone graft, and the esophagocutaneous fistula site was primary repaired, but pus continued to drain. Conservative treatment, which consisted of wound drainage and intravenous administration of antibiotics, was tried, but was unsuccessful. After all, we removed the plate and screws, but did not removed the iliac bone graft, We closed the esophageal fistula, and transposed the sternocleidomastoid muscle flap to the interspace between the esophagus and the cervical spine. The wound to the esophagus was well repaired. In conclusion, precautionary measures are needed to avoid the complication, and adequate treatment is necessary to resolve those complications when they occur.

Cost-Effectiveness Analysis of Cervical Anterior Fusion and Cervical Artificial Disc Replacement in the Korean Medical System

  • Lee, Hyosang;Kim, Ui Chul;Oh, Jae Keun;Kim, Taehyun;Park, Sohee;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.1
    • /
    • pp.83-89
    • /
    • 2019
  • Objective : This study is a retrospective cost-benefit analysis of cervical anterior interbody fusion and cervical artificial disc replacement, which are the main surgical methods to treat degenerative cervical disc disease. Methods : We analyzed 156 patients who underwent anterior cervical disc fusion and cervical artificial disc replacement from January 1, 2008 to December 31, 2009, diagnosed with degenerative cervical disc disorder. In this study, the costs and benefits were analyzed by using quality adjusted life year (QALY) as the outcome index for patients undergoing surgery, and a Markov model was used for the analysis. Only direct medical costs were included in the analysis; indirect medical costs were excluded. Data were analyzed with TreeAge Pro $2015^{TM}$ (TreeAge Software, Inc, Williamstown, MA, USA). Results : Patients who underwent cervical anterior fusion had a total cost of KRW 2501807/USD 2357 over 5 years and obtained a utility of 3.72 QALY. Patients who underwent cervical artificial disc replacement received 4.18 QALY for a total of KRW 3685949/USD 3473 over 5 years. The cumulative cost-effectiveness ratio of cervical spine replacement surgery was KRW 2549511/QALY (USD 2402/QALY), which was lower than the general Korean payment standard. Conclusion : Both cervical anterior fusion and cervical artificial disc replacement are cost-effective treatments for patients with degenerative cervical disc disease. Cervical artificial disc replacement may be an effective alternative to obtain more benefits.

Subsidence Ratio after Anterior Cervical Interbody Fusion Using an Intraoperative Custom-made Cervical Cage

  • Kim, Dok-Ryong;Moon, Byung-Gwan;Kim, Jae-Hoon;Kang, Hee-In;Lee, Seung-Jin;Kim, Joo-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.5
    • /
    • pp.301-305
    • /
    • 2007
  • Objective : The postoperative subsidence of anterior cervical interbody fusion for cervical degenerative diseases gives rise to segmental kyphotic collapse, screw loosening, and chronic neck pain. So, intraoperative custom-made polymethylmethacrylate [PMMA] C-cage has been developed to prevent subsidence following anterior cervical fusion. Methods : A total of patients who underwent anterior cervical interbody fusion with a intraoperative custom - made cervical cage filled with local bone and demineralized bone matrix [group A] were analyzed prospectively from June 2004 to June 2005. These were compared with 40 patients who were treated with iliac bone graft [group B]. We evaluated subsidence ratio, change of segmental angle, distraction length and segmental angle. Statistical analysis was performed using independent sample t-test and Pearson correlation coefficient. Results : Group A had a statistically significant decrease in subsidence ratio [$0.64{\pm}0.43%$, p=0.00]. distraction length [$2.42{\pm}1.25\;mm$, p=0.02], and follow angle change [$1.78{\pm}1.69^{\circ}$, p=0.01] as compared with Group B. However, there was no statistically significant difference in postoperative segmental angle change [p=0.66]. On the analysis of the correlation coefficient, the parameters showed no interrelationships in the group A. On the other hand, subsidence ratio was affected by distraction length in the group B [Pearson correlation=0.448]. Conclusion : This operative technique would be contributed for the reduction of a postoperative subsidence after the anterior cervical interbody fusion procedure for cervical disc disease with moderate to severe osteoporotic condition and segmental loss of lordosis.

Anterior Cervical Discectomy and Fusion Using a Stand-Alone Polyetheretherketone Cage Packed with Local Autobone : Assessment of Bone Fusion and Subsidence

  • Park, Jeong-Ill;Cho, Dae-Chul;Kim, Kyoung-Tae;Sung, Joo-Kyung
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.189-193
    • /
    • 2013
  • Objective : It remains debatable whether cervical spine fusion cages should be filled with any kind of bone or bone substitute. Cortical and subcortical bone from the anterior and posterior osteophytes of the segment could be used to fill the cage. The purposes of the present study are to evaluate the clinical outcomes and radiological outcomes including bone fusion and subsidence that occurred after anterior cervical discectomy and fusion using a stand-alone cage packed with local autobone graft. Methods : Thirty-one patients who underwent anterior cervical fusion using a stand-alone polyetheretherketone (PEEK) cage packed with local autobone graft from July 2009 to december 2011 were enrolled in this study. Bone fusion was assessed by cervical plain radiographs and computed tomographic scan. Nonunion was evaluated according to the absence of bony bridge on computed tomographic scan. Subsidence was defined as a ${\geq}2$ mm decrease of the interbody height at the final follow-up compared to that measured at the immediate postoperative period. Results : Subsidence was observed in 7 patients (22.6%). Of 7 patients with subsidence greater 2 mm, nonunion was developed in 3. Three patients with subsidence greater 2 mm were related with endplate damage during intraoperative endplate preparation. Solid bone fusion was achieved in 28 out of 31 patients (90.3%). Conclusion : With proper patient selection and careful endplate preparation, anterior cervical discectomy and fusion (ACDF) using a stand-alone PEEK cage packed with local autobone graft could be a good alternative to the standard ACDF techniques with plating.

Clinical Experience of Anterior Cervical Interbody Fusion with the PCB System (전방 경추 유합술에서의 PCB System의 임상적 경험)

  • Kim, Sung Han;Kim, Ho Jin;Kang, Jae Kyu;Doh, Jong Oung;Lee, Chun Dae
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1170-1176
    • /
    • 2001
  • Objective : The purpose of the study was to evaluate the clinical and radiological results after discectomy and Lubboc bone graft in the surgical management of the cervical diseases with a new titanium interbody implant and integrated screw fixation(PCB) by anterior approach. Methods : The authors retrospectively analyzed 28 cases of anterior cervical fusion with PCB system and Lubboc bone(xeno graft) from september 1998 to december 2000. Twenty-eight patients with cervical diseases underwent decompression cervical lesion and followed from 5 to 27 months with a mean follow-up of 14 months. There patients were evaluated with clinically and radiologically at immediate postoperative period and at 3, 6, 9, and 12 months. Result : The authors investigated the pre- and postoperative intervertebral disc space, clinical outcomes, radiography fusion rate, and Cobb angle in the fixed segments by anterior approach. The lordotic angles and height of disc space were increased after the operation. The clinical outcome of patients follow-up was good or excellent result based on Odom's criteria with improvement of clinical symptom in about 92.9% of the cervical diseases. Two patients showed loosening of the lower and upper cervical screw of PCB instruments, and two patients showed swallowing difficulty and wound infection Conclusion : The PCB system is a new implant for anterior cervical interbody fusion in the degenerative cervical disease and disc herniations. It provides immediate stability and segment distraction. The results of this study indicate that the PCB system is safe, easy handling of hardware, less complications, high fusion rate, and has provide the keeping the intervertebral disc space height and lordotic angles.

  • PDF

Anterior Cervical Instrumentation Using Intradiscal Cage with Integrated Plate

  • Ahn, Kyoung-Rok;Ryu, Kyeong-Sik;Chang, In-Bok;Cho, Byung-Moon;Park, Se-Hyuck;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.260-264
    • /
    • 2006
  • Objective : The retrospective study is undertaken to report clinical results of anterior cervical interbody fusion with an intradiscal cage with an integrated plate [PCB cervical plating system]. Methods : 38 patients underwent anterior cervical interbody fusion with PCB cervical plating system and followed $6{\sim}24\;months$. The authors investigated overall surgical results; clinical outcome, fusion rate, change of interspace height & lordotic angle, and complications. Results : No complication was observed during the operation. Clinical improvement was identified in 34 cases [89.5%]. Bone fusion observed in 44 out of 49 sites [90.7%]. After operation, the interspace height increased from $5.4{\pm}1.3mm$ to $7.8{\pm}1.5mm$ and maintained $7.4{\pm}1.1mm$ and, interspace angle went up from $4.2{\pm}0.7^{\circ}$ to $4.8{\pm}1.1^{\circ}$ and maintained $4.6{\pm}$0.9^{\circ}. The loosening of screw was observed in 6 cases, one of which had reoperation because of the expulsion of the device accompanied. Conclusion : PCB cervical plating system could restore interbody height and lordosis in anterior cervical interbody fusion. But, if the insertion of the spacer is not precise, the frequencies of hardware failure are relatively high. It is considered necessary for the operator to be careful in the procedure.

Analysis of Posterior Cervical Fixation and Fusion in Subaxial Cervical Spine Injury (중하부 경추손상에서 후방 경추 내고정술 및 골유합술의 분석결과)

  • Lee, Dong Hoon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.12
    • /
    • pp.1388-1393
    • /
    • 2001
  • Objective : In the retrospective analyzing 19 consecutive patients with subaxial cervical spine(C3~T1) injury treated by posterior cervical fixation and fusion, clinical manifestation, radiologic finding, operative technique, and postoperative results following 6 months were analyzed. Materials and Methods : Most common fracture level was C4-5, mean age 41, and male to female ratio 13 : 6. The most common cause of injury was motor vehicle accident(17 cases). In 19 cervical procedures, interspinous triple wiring was done in 14 cases, lateral mass plating in 5 cases, and additional anterior fusion in 2 cases. Results : Twelve weeks after operation, all cases were reviewed by plain cervical radiogram. In 17 cases that treated by posterior fusion only, 14 cases(81%) had kyphotic angle change less than $5^{\circ}$, 2 cases(12%) $5-20^{\circ}$, and 1 case(6%) more than $20^{\circ}$. Overall fusion rate was 88%, and there was no significant difference of bone fusion rate between autogenous bone graft and allogenous bone graft. Conclusion : In the case of severe posterior column injury or displacement, posterior approach seems superior to anterior approach, but in the case of combined anterior column injury, anterior approach is considered necessary. In this study, posterior fixation and fusion might be acceptable procedure for subaxial cervical fracture and dislocation, owing to its high fusion rate, low kyphotic angulation and low operation related complication rate.

  • PDF