• Title/Summary/Keyword: Anode-supported planar SOFC

Search Result 20, Processing Time 0.027 seconds

Development of stacks and power generation systems based on anode-supported SOFCs for intermediate temperature operation (연료극 지지체형 SOFC를 이용한 중.저온용 스택 및 발전시스템 개발)

  • Lee, Tae-hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Young-Sung;Park, Jin-Woo
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1986-1991
    • /
    • 2007
  • KEPRI has studied anode-supported planar SOFCs and kW class stacks operated at intermediate temperature for development of a combined heat and power unit. A single cell composed of Ni-YSZ/FL/ScSZ/LSCF showed the maximum power density of 0.55 W/$cm^2$ at $650^{\circ}C$ and 1.8 W/$cm^2$ at $750^{\circ}C$. With 37 cells of 10${\times}10cm^2$ and stainless steel interconnects, a 1kW class SOFC stack was manufactured. When a 1kW class SOFC system was operated at $750^{\circ}C$ with city gas, it showed the power output of 1.3 kWe at 50 A. It also recuperated heat of 0.57-1.2 kWth according to the loaded current through combustion of unreacted anode off-gas. Recently, KEPRI is developing a new kW class SOFC stack and system to increase efficiency and durability at intermediate temperature.

  • PDF

Study on Reversible Electrolysis Characteristic of a Planar Type SOFC (평판형 고체산화물 연료전지의 양방향 수전해 특성 연구)

  • CHOI, YOUNGJAE;AHN, JINSOO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.657-662
    • /
    • 2017
  • This paper presents the reversible electrolysis characteristics of a solid oxide fuel cell (SOFC) using a $10{\times}10cm^2$ anode supported planar cell with an active area of $81cm^2$. In this work, current-voltage characteristic test and reversible electrolysis cycle test were carried out sequentially for 2,114 hours at a furnace temperature of $700^{\circ}C$. The current-voltage characteristics for reversible electrolysis mode was measured at a current of ${\pm}26.7A$ under various $H_2O$ utilization conditions. The reversible electrolysis cycle was performed 50 times at a current of ${\pm}32.4A$. As a result, The performance degradation of SOEC mode was larger than that of SOFC mode.

Simplified Resistor Network Calculation for Electrical and Mass Transport in Anode-Supported Planar Solid Oxide Fuel Cell (연료극지지 평판형 고체산화물 연료전지 내에서의 전기 및 물질전달에 대한 간략화된 저항 네트워크 계산)

  • Lee, Hyun-Jae;Nam, Jin-Hyun;Kim, Charn-Jung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1740-1745
    • /
    • 2004
  • A simplified resistor network model for electrical and mass transport in anode-supported planar solid oxide fuel cell (SOFC) was constructed in order to investigate the effect of interconnect rib geometry on the cell performance. For accurate potential calculation, activation and concentration over-potentials at the electrode/electrolyte interfaces were fully considered in this calculation. When contact resistance was not considered, the optimum interconnect rib length were calculated to be $0.1{\sim}0.2$ mm for 2 mm half unit cell for given operation conditions and properties. However, with realistic contact resistance, the interconnect rib length should be increased to provide larger contact area and thus to obtain better performance.

  • PDF

Current Status of SOFC Materials and Processing Core Technology (고체산화물 연료전지 소재공정 요소기술 개발 현황)

  • Lee, Jong-Ho;Son, Jiwon;Kim, Heryong;Kim, Byong-Kook;Lee, Hae-Weon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.123.1-123.1
    • /
    • 2010
  • The solid oxide fuel cell (SOFC) has attracted great deal of attention due to its high electrical efficiency, high waste-heat utilization, fuel flexibility, and application versatility. However, SOFC technology is still not matured enough to fulfill the practical requirements for commercialization. Therefore, all the research and development activities are mainly focused on a development of practically viable SOFCs with higher performance and better reliability. We were successful in fabricating high-performance anode-supported unit cells by employing hierarchically controlled multi-layered electrodes for both structural reliability and high performance. In addition, a novel composite sealing gasket made it possible to achieve excellent sealing integrity even with considerable surface irregularities in a multi-cell planar arrayed stack.

  • PDF

Performance Characteristics of Anode-Supported Tubular Solid Oxide Fuel Cell (연료극 지지체식 원통형 고체산화물 연료전지의 성능 특성)

  • Song Rak-Hyun;Song Keun-Suk
    • Korean Journal of Materials Research
    • /
    • v.14 no.5
    • /
    • pp.368-373
    • /
    • 2004
  • To improve the conventional cathode-supported tubular solid oxide fuel cell (SOFC) from the viewpoint of low cell power density, expensive fabrication process and high operation temperature, the anode-supported tubular solid oxide fuel cell was investigated. The anode tube of Ni-8mol% $Y_2$O$_3$-stabilized $ZrO_2$ (8YSZ) was manufactured by extrusion process, and, the electrolyte of 8YSZ and the multi-layered cathode of $LaSrMnO_3$(LSM)ILSM-YSZ composite/$LaSrCoFeO_3$ were coated on the surface of the anode tube by slurry dip coating process, subsequently. Their cell performances were examined under gases of humidified hydrogen with 3% water and air. In the thermal cycle condition of heating and cooling rates with $3.33^{\circ}C$/min, the anode-supported tubular cell showed an excellent resistance as compared with the electrolyte-supported planar cell. The optimum hydrogen flow rate was evaluated and the air preheating increased the cell performance due to the increased gas temperature inside the cell. In long-term stability test, the single cell indicated a stable performance of 300 mA/$\textrm{cm}^2$ at 0.85 V for 255 hr.

Fabrication and Performance Test in Stacks up to 1kW Planar Solid Oxide Fuel Cell (1kW 평판형 SOFC 스택제작 및 성능평가)

  • Cho, Nam-Ung;Hwang, Soon-Cheoi;Han, Sang-Moo;Kim, Yeong-Woo;Kim, Seung-Goo;Jun, Jae-Ho;Kim, Do-Hyeong;Jun, Joong-Hwan
    • New & Renewable Energy
    • /
    • v.3 no.3
    • /
    • pp.5-13
    • /
    • 2007
  • Stacks of solid oxide fuel cell with 1kW max power performance were designed on planar type employing anode-supported cells and metallic interconnects. The stacks composed of 3-cells, 8-cells, and 16-cells were fabricated and tested in serials by using anode-supported cells purchased from Indec, and sealants/interconnects prepared at RIST. In the performance test of the final 16-cells stack, OCV was recorded to be 16.7V. The peak power and the power density showed 1 kW, $0.77W/cm^2$ at $820^{\circ}C$, respectively. In addition, the long-term degradation rate of the power exhibited 2.25 % during 500h at $750^{\circ}C$.

  • PDF

Bi-layer Electrolyte for Preventing Solid Oxide Fuel Cell Stack Degradation (고체산화물 연료전지 스택 열화 방지를 위한 전해질 기술)

  • Park, Mi Young;Bae, Hongyeul;Lim, Hyung-Tae
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.4
    • /
    • pp.289-294
    • /
    • 2014
  • The stability of a solid oxide fuel cell (SOFC) stack is strongly dependent on the magnitude and profile of the internal chemical potential of the solid electrolyte. If the internal partial pressure is too high, the electrolyte can be delaminated from the electrodes. The formation of high internal pressure is attributed to a negative cell voltage, and this phenomenon can occur in a bad cell (with higher resistance) in a stack. This fact implies that the internal chemical potential plays an important role in determining the lifetime of a stack. In the present work, we fabricate planar type anode-supported cells ($25cm^2$) with a bi-layer electrolyte (with locally increased electronic conduction at the anode side) to prevent high internal pressure, and we test the fabricated cells under a negative voltage condition. The results indicate that the addition of electronic conduction in the electrolyte can effectively depress internal pressure and improve the cell stability.

Self-sustainable Operation of a 1kW class SOFC System (1kW급 고체산화물 연료전지 발전시스템 자열운전)

  • Lee, Tae-Hee;Choi, Jin-Hyeok;Park, Tae-Sung;Yoo, Young-Sung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • KEPRI has studied planar type SOFC stacks using anode-supported single cells and kW class co-generation systems for residential power generation. A 1kW class SOFC system consisted of a hot box part, a cold BOP part and a water reservoir. A hot box part contains a SOFC stack made up of 48 single cells and ferritic stainless steel interconnectors, a fuel reformer, a catalytic combustor and heat exchangers. Thermal management and insulation system were especially designed for self-sustainable operation. A cold BOP part was composed of blowers, pumps, a water trap and system control units. When a 1kW class SOFC system was operated at $750^{\circ}C$ with hydrogen after pre-treatment process, the stack power was 1.2kW at 30 A and 1.6kW at 50A. Turning off an electric furnace, the SOFC system was operated using hydrogen and city gas without any external heat source. Under self-sustainable operation conditions, the stack power was about 1.3kW with hydrogen and 1.2kW with city gas respectively. The system also recuperated heat of about 1.1kW by making hot water.

  • PDF