• Title/Summary/Keyword: Annular Gap

Search Result 73, Processing Time 0.028 seconds

Preliminary Study for the Development of Optimum Fuel Contact Conductance Model (최적 핵연료 접촉 열전도도 모델 개발을 위한 예비 연구)

  • Yang, Yong-Sik;Shin, Chang-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2488-2493
    • /
    • 2007
  • A gap conductance is very important factor which can affect nuclear fuel temperature. Especially, in case of an annular fuel, a gap conductance effect can lead an unexpected heat split phenomena which is caused by a large difference of an inner and outer gap conductance. The gap conductance mechanism is very complicated behavior due to the its strong dependency on microscopic factors such as a contact surface roughness, local contact pressure and local temperature. In this paper, for the decision of test temperature and pressure range, a procedure and calculation results of in-reactor fuel temperature and pressure analysis are summarized which can be applied to test equipment design and determination of test matrix. Based upon analysis results, it is concluded that the minimum and maximum test temperature are $300^{\circ}C$ and $530^{\circ}C$ respectively, and the maximum pellet/cladding interfacial contact pressure should be observed up to 45MPa.

  • PDF

Analytical and experimental study on natural sloshing frequencies in annular cylindrical tank with a bottom gap

  • Lee, H.W.;Jeon, S.H.;Cho, J.R.;Seo, M.W.;Jeon, W.B.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.5
    • /
    • pp.877-895
    • /
    • 2016
  • This paper is concerned with the analytical derivation of natural sloshing frequencies of liquid in annular cylindrical tank and its verification by experiment. The whole liquid domain is divided into three simple sub-regions, and the region-wise linearized velocity potentials are derived by the separation of variables. Two sets of matrix equations for solving the natural sloshing frequencies are derived by enforcing the boundary conditions and the continuity conditions at the interfaces between sub-regions. In addition, the natural sloshing frequencies are measured by experiment and the numerical accuracy of the proposed analytical method is verified through the comparison between the analytical and experimental results. It is confirmed that the present analytical method provides the fundamental sloshing frequencies which are in an excellent agreement with the experiment. As well, the effects of the tank radial gap, the bottom flow gap and the liquid fill height on the fundamental sloshing frequency are parametrically investigated.

Temperature and Heat Split Evaluation of Annular Fuel (이중냉각핵연료 온도 및 열유속 분리 평가)

  • Yang, Yong-Sik;Chun, Tae-Hyun;Shin, Chang-Hwan;Song, Kun-Woo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2236-2241
    • /
    • 2008
  • The surface heat flux of nuclear fuel rod is the most important factor which can affect safety of reactor and fuel. If fuel rod surface heat flux exceeds the CHF(${\underline{C}}ritical$ ${\underline{H}}eat$ ${\underline{F}}lux$), fuel can be damaged. In case of double cooled annular fuel, which is under developing, contains two coolant channels. Therefore, a generated heat in the fuel pellet can move to inner or outer channel and heat flow direction is decided by both sides heat resistance which varied by dimension and material property change which caused by temperature and irradiation. The new program(called DUO) was developed. For the calculation of surface heat flux, a both sides convection by inner/outer coolant, s gap temperature jump and conduction in the fuel are modeled. Especially, temperature and time dependent fuel dimension and material property change are considered during the iteration. A sample calculation result shows that the DUO program has sufficient performance for annular fuel thermal hydraulics design.

  • PDF

Design of Direct-Shear Mode MR Damper (전단 모드형 자성유체댐퍼의 설계)

  • Kim, Hae-Lan;Lee, Young-Shin;Lee, Eun-Yup;Lee, Gyu-Seop;Oh, Boo-Jin
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.626-631
    • /
    • 2007
  • MR(Magneto-rheological) fluid is smart material that can be changed viscosity by controlling the magnetic field. MR damper with MR fluid can control damping force. It can be used extensively many engineering structures for reducing the effect of dynamic external disturbances. There are three kinds of MR dampers, such as valve mode, direct-shear mode and squeeze mode. In this study, design process of direct-shear mode MR damper with the MR fluid gap was developed. The parameters that used in the direct-shear mode MR damper Informed from the experiment of valve mode MR damper of Lord company. Magnetic analysis with finite element method was performed to find the optimal annular gap.

  • PDF

Counter-Current Gas-Liquid Two-Phase Flow Regimes in Narrow Rectangular Channels (협소 사각 유로에서 대향류 기/액 2상 유동양식)

  • Sohn, B.H.;Kim, B.J.;Jeong, S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.136-141
    • /
    • 2000
  • A study of counter-current two-phase flow in narrow rectangular channels has been performed. Two-phase flow regimes were experimentally studied in 760 mm long and 100 mm wide test sections with 2.0 and 3.0mm gaps. The resulting data have been compared to previous transition models. For the transition from bubbly to slug flow the superficial velocity of gas increased as the gap width increased. The comparison of experimental data to the transition model developed by Taitel and Barnea showed relatively good agreement for the bubbly-to-slug transition in the case of 2mm gap width. For the criteria of Mishima and Ishii to be applicable to the slug-to-churn transition the distribution parameter should be well defined for narrow channels. Even though the gap width of narrow channels increased the superficial gas velocity did not change for the transition form chum to annular flow regime. For the chum-to-annular transition the model of Taitel and Barnea showed discrepancies with experimental data, especially in the channel with larger gap.

  • PDF

The Design of a PCS Band Microstrip Patch Antenna with Auxiliary Wire and Annular Gap (보조 도선과 Annular Gap을 추가한 PCS 대역 마이크로스트립 패치 안테나 설계)

  • Choi, Kyoung-Sik;Yoon, Jong-Soeb;Ryu, Mi-Ra;Lee, Won-Hui;Hur, Jung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.3
    • /
    • pp.329-338
    • /
    • 2001
  • In this paper, we designed microstrip patch antenna to enhance the weak point of general microstrip patch antenna that has narrow bandwidth and analyzed that. To reduce reactance in probe feed antenna, capacitive gap added to the patch. Using single patch and auxiliary wire, makes dual frequency resonant. So bandwidth is improved and gain also becomes higher. To verify with experiment, PCS band antenna is designed, fabricated. For PCS band antenna, bandwidth is 180 MHz in VSWR<1.5 and gain is 8.6 dBi.

  • PDF

Sloshing characteristics of an annular cylindrical tuned liquid damper for spar-type floating offshore wind turbine

  • Jeon, S.H.;Seo, M.W.;Cho, Y.U.;Park, W.G.;Jeong, W.B.
    • Structural Engineering and Mechanics
    • /
    • v.47 no.3
    • /
    • pp.331-343
    • /
    • 2013
  • The natural sloshing frequencies of annular cylindrical TLD are parametrically investigated by experiment, aiming at the exploration of its successful use for suppressing the structural vibration of spar-type floating wind turbine subject to multidirectional wind, wave and current excitations. Five prototypes of annular cylindrical TLD are defined according to the inner and outer radii of acryl container, and eight different liquid fill heights are experimented for each TLD prototype. The apparent masses near the first and second natural sloshing frequencies are parametrically investigated by measuring the apparent mass of interior liquid sloshing to the acceleration excitation. It is observed from the parametric experiments that the first natural sloshing frequency shows the remarkable change with respect to the liquid fill height for each TLD model with different container dimensions. On the other hand, the second natural sloshing frequency is not sensitive to the liquid fill height but to the gap size, for all the TLD models, convincing that the annular cylindrical sloshing damper can effectively suppress the wave- and wind-induced tilting motion of the spar-type floating wind turbine.

EFFECTS OF GEOMETRIC PARAMETERS ON NUCLEATE POOL BOILING OF SATURATED WATER IN VERTICAL ANNULI

  • Kang, Myeong-Gie
    • Nuclear Engineering and Technology
    • /
    • v.41 no.3
    • /
    • pp.271-278
    • /
    • 2009
  • Nucleate pool boiling of water in vertical annuli at atmospheric pressure has been studied experimentally and two empirical correlations have been suggested to obtain effects of geometric parameters on heat transfer. Data of the present and the previous tests range over a tube length of 0.50-0.57 m, a diameter of 16.5-34.0 mm, and an annular gap size of 3.7-44.3 mm. Through the analysis, tube bottom confinement (open or closed) has been investigated, as well. The developed correlations predict experimental data within a ${\pm}25%$ error bound. It has been identified that effects of the diameter and the length of heated tubes as well as the annular gap size should be counted into the analyses to estimate heat transfer coefficients accurately.

Design of Dual-Band, Dual-Polarized Microstrip Patch Antenna with Two Input Ports (두 입력단자를 갖는 이중대역 이중편파 마이크로스트립 패치 안테나 설계)

  • Jeong Hae-Young;Lee Kwang-Chun;Lee Sung-Jun;Choi Ik-Guen
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.11 s.102
    • /
    • pp.1164-1170
    • /
    • 2005
  • This paper presents a dual-band, dual-polarized microstrip patch antenna with simple dual-probe feed. The inter-port isolation and cross-polarization are greatly improved by designing feed structure with annular gap between patch and feed-probe. Measured results show that the antenna's inter-port isolation and cross-polarization in each -10 dB return loss bandwidth of $1.84\;GHz\~l.93\;GHz$ and $2.62\;GHz\~2.81\;GHz$ are greater than 21 dB, greater than 22.2 dB and greater than 27 dB, greater than 19 dB, respectively. The antenna gain is about 6.9 dBi in both frequency bands.

Dynamic Stability of a Flexible Cylinder Subjected to Inviscid Flow in a Coaxial Cylindrical Duct Based on Spectral Method (스펙트럼 배치방법에 의한 원형도관내의 비점성유동장에 놓인 유연성 실린더의 안정성 분석)

  • Sim, Woo-Gun;Bae, Yoon-Yeong
    • Nuclear Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.212-224
    • /
    • 1994
  • A numerical method has been developed for studying the dynamics of a flexible cylinder in a coaxial cylindrical duct, immersed in inviscid flow. The unsteady inviscid fluid-dynamic force acting on the oscillating cylinder has been estimated more rigorously by means of a spectral collocation method without simplification of governing equations. This numerical approach is applicable to the system haying wider annular gap and/or shorter length of cylinder as compared to existing potential theory. The governing equation of the unsteady flow was obtained from Laplace equation. The equation of cylinder motion coupled with the fluid motion was discretized by Galerkin's method, from which the dynamic behaviour of the system has been evaluated. The effect of the length of the cylinder and the annular gap on the critical flour velocity, where the system loses stability by buckling, was investigated. To validate the numerical method, the potential flow theory developed by Hobson based on thin film approximation has been improved. Typical results of the present numerical theory on the dynamics and stability of the system are compared with those of available existing theory and the present approximate results. Good agreement was found between the results. It was also found that a nondimensional critical flow velocity becomes larger as increasing the annular gap and decreasing the length of cylinder.

  • PDF