• 제목/요약/키워드: Annual energy performance assessment

검색결과 22건 처리시간 0.025초

풍력자원 계측자료 분석용 상용 소프트웨어 비교분석 (Comparative Analysis of Commercial Softwares for Wind Climate Data Analysis)

  • 김현구
    • 신재생에너지
    • /
    • 제6권2호
    • /
    • pp.5-11
    • /
    • 2010
  • This paper reviews three commercial softwares for wind climate data analysis in wind resource assessment; WAsP/Observed Wind Climate, WindRose and Windographer. Windographer is evaluated as the best software because of its variety of input data format, analysis functions, easiness of user interface, etc. For a quantitative understanding of uncertainty depending on software selection, a benchmark is carried out with the met-mast observation dataset at the Gimnyeong Wind Turbine Performance Test Site. It is found that Weibull parameter calculation and air density correction have a dependency on the software so that such uncertainty should be considered when an analysis software is selected. It is confirmed that annual energy production calculated by WAsP using a statistical table of frequency of occurrence may have some error compared to a time-series calculation method used by the other softwares.

투자회수기간을 고려한 군 주거시설의 단열수준 산정 연구 (Insulation Level Assessment on the Military Residential Facilities Considering the Investment Payback Period)

  • 박영준;맹준호;김태희;김성중;이승민;손기영
    • KIEAE Journal
    • /
    • 제15권6호
    • /
    • pp.57-62
    • /
    • 2015
  • Purpose: This study, which is based on the investment payback periods, aims to suggest the proper insulation level which can be adapted to the Defense Military Facility Criteria regarding the military residential condominiums. For the energy performance simulation, it is required to collect the residential data regarding the military condominiums and climatic data concerning the regions they belongs to. The estimates through energy performance simulation are the regional heating loads and the heating transmission coefficients of building components. Method: With the heating loads, the annual heating cost saving per square meters is assessed. With the heating transmission coefficients of building components, the additional insulation installment cost per square meters is evaluated. With two outcomes, one as an annual value and the other as a present value, the investment payback period is calculated. Result: In result, it could be concluded that 55~70% insulation ratio can lead a superior residental environments as well as be contributed to the national policy associated with zero-energy buildings because the estimated investment payback period is shorter than the life span of the military residental condominiums. This upshot can be used as a foundation to enactment the Defense Military Facility Criteria associated with military residential condominiums.

풍력 터빈의 요 제어에 따른 하중 및 성능 영향성 평가 (Assessment of Wind Turbine Load and Performance Effects by Yaw Control)

  • 김진;김지언;고장욱;권기영
    • 풍력에너지저널
    • /
    • 제4권1호
    • /
    • pp.46-52
    • /
    • 2013
  • The wind generally includes turbulence characteristics in nature. So the yaw errors between wind turbine direction and wind direction occur due to turbulence fluctuation. The yaw errors affect the fatigue load of wind turbine system and power reduction. The components of turbulence intensity are different from those of each site where the wind turbines are installed. We studied that the fatigue load and power efficiency are improved by controlling yaw motions. In this study, we controlled the averaged yaw error time according to site conditions by turbulence intensity.

업무용 건물의 이중외피 성능평가를 위한 해석기법의 고찰 - 이중외피 설계안의 에너지 저감 성능 및 환기성능을 중심으로 - (A Study on Analysis Method for Performance Evaluation of Double-leaf facade of Office Building)

  • 정환교;정광섭;이용준;신승철;김영일
    • 에너지공학
    • /
    • 제21권2호
    • /
    • pp.168-178
    • /
    • 2012
  • 본 연구는 업무용 건물에 적용되는 이중외피의 성능을 설계단계에서 평가할 수 있는 정량적인 평가방법을 정립하기 위한 기초적인 평가 수행을 목적으로 하였다. 이를 위하여 평가대상 건물을 선정하여 이중외피 적용을 위한 설계안에 대하여 이중외피 적용 전후의 연간 냉난방 부하를 동적 열부하 해석 프로그램을 이용하여 수행하였으며, 보다 현실적인 평가 결과의 도출을 위하여 CFD를 활용한 풍압계수 도출 및 이를 적용한 환기량 해석을 병행하였고, 이중외피의 환기구 및 중공층 내부의 차양 제어를 위한 모드 설정 및 제어를 통하여 이중외피의 적용 및 제어에 따른 효과를 보다 현실적으로 수행할 수 있는 기법을 제안하였다. 이를 통하여 대상 건물에 대한 이중외피 적용에 따른 연간 냉난방부하를 해석하여 적용 효과를 정량적으로 도출할 수 있는 가능성을 확인하였으며, 이중외피의 형태에 따른 중공층 환경 변화를 확인하였다.

자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구 (Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application)

  • 윤종호;김석기;송종화;이성진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

Probabilistic seismic performance evaluation of non-seismic RC frame buildings

  • Maniyar, M.M.;Khare, R.K.;Dhakal, R.P.
    • Structural Engineering and Mechanics
    • /
    • 제33권6호
    • /
    • pp.725-745
    • /
    • 2009
  • In this paper, probabilistic seismic performance assessment of a typical non-seismic RC frame building representative of a large inventory of existing buildings in developing countries is conducted. Nonlinear time-history analyses of the sample building are performed with 20 large-magnitude medium distance ground motions scaled to different levels of intensity represented by peak ground acceleration and 5% damped elastic spectral acceleration at the first mode period of the building. The hysteretic model used in the analyses accommodates stiffness degradation, ductility-based strength decay, hysteretic energy-based strength decay and pinching due to gap opening and closing. The maximum inter story drift ratios obtained from the time-history analyses are plotted against the ground motion intensities. A method is defined for obtaining the yielding and collapse capacity of the analyzed structure using these curves. The fragility curves for yielding and collapse damage levels are developed by statistically interpreting the results of the time-history analyses. Hazard-survival curves are generated by changing the horizontal axis of the fragility curves from ground motion intensities to their annual probability of exceedance using the log-log linear ground motion hazard model. The results express at a glance the probabilities of yielding and collapse against various levels of ground motion intensities.

Influence of EDZ on the Safety of a Potential HLW Repository

  • 황용수;강철형
    • 방사성폐기물학회지
    • /
    • 제2권4호
    • /
    • pp.253-262
    • /
    • 2004
  • Construction of tunnels in a deep crystalline host rock for a potential High-Level Radioactive Waste(HLW) repository inevitably generates an excavation disturbed zone (EDZ). There have been a series of debates on whether a permeability in an EDZ increases or not and what would be the maximum depth of an EDZ. Recent studies show mixed opinions on permeability. However, there has been an international consensus on the thickness of an EDZ; 30 cm for TBM and 1 meter for controlled blast. One of the impacts of an EDZ is on determining the distance between adjacent deposition holes. The void gap by the excavation hinders relaxation of temperature profiles so that the current Korean reference designing distance between holes should be stretched out more to keep the maximum temperature in a buffer region below 100 degrees Celsius. The other impact of an EDZ is on the long-term post closure radiological safety. To estimate the impact, the reference scenario, the well scenario, is chosen. Released nuclides diffuse through a bentonite buffer region experiencing strong sorption and reach a fracture surrounded by a porous medium. Inside a fractured porous region, radionuclides migrate by advection and dispersion with matrix diffusion into a porous medium. Finally, they reach a well assumed to be a source of potable water for local residents. The annual individual dose is assessed on this well scenario to find out the significance of an EDZ. A profound sensitivity study was performed, but all results show that the impact is negligible. Even though the role of an EDZ turns out to be limited on overall safety assessment, still it is worthwhile to study the chemical role of an EDZ, such as a potential source for natural colloids, potential sealing of an open fracture by fine clay particles generated by the process of an EDZ, and alteration of a sorption mechanism by an EDZ in the future.

  • PDF

Seismic fragility assessment of steel moment-resisting frames equipped with superelastic viscous dampers

  • Abbas Ghasemi;Fatemeh Arkavazi;Hamzeh Shakib
    • Earthquakes and Structures
    • /
    • 제25권5호
    • /
    • pp.343-358
    • /
    • 2023
  • The superelastic viscous damper (SVD) is a hybrid passive control device comprising a viscoelastic damper and shape memory alloy (SMA) cables connected in series. The SVD is an innovative damper through which a large amount of seismic energy can dissipate. The current study assessed the seismic collapse induced by steel moment-resisting frames (SMRFs) equipped with SVDs and compared them with the performance of special MRFs and buckling restrained brace frames (BRBFs). For this purpose, nonlinear dynamic and incremental dynamic analysis (IDA) were conducted in OpenSees software. Both 5- and 9-story special MRFs, BRBFs, and MRFs equipped with the SVDs were examined. The results indicated that the annual exceedance rate for maximum residual drifts of 0.2% and 0.5% for the BRBFs and MRFs with SVDs, respectively, were considerably less than for SMRFs with reduced-beam section (RBS) connections and that the seismic performances of these structures were enhanced with the use of the BRB and SVD. The probability of collapse due to residual drift in the SVD, BRB, and RBS frames in the 9-story structure was 1.45, 1.75, and 1.05 times greater than for the 5-story frame.

터빈설치를 위한 한국 연안 해상풍력발전 부존량 평가 (Assessment of Offshore Wind Power Potential for Turbine Installation in Coastal Areas of Korea)

  • 강금석;오남선;고동휘;정신택;황재동
    • 한국해안·해양공학회논문집
    • /
    • 제30권4호
    • /
    • pp.191-199
    • /
    • 2018
  • 본 연구에서는 한국 연안의 해상풍력 발전을 위한 적지를 검토하기 위해 기상청에서 제공하는 20개 지점의 풍속 자료를 수집하고 이를 분석하였다. 관측된 풍속 자료의 분석을 위하여 Rayleigh 모델과 Weibull 모델을 이용하였으며, 풍속 출현빈도에 따라 연간 부존량을 추정하였다. 풍력발전기 모델로는 출력 1.5~5 MW의 7종류를 선정하여 각각의 성능곡선을 이용하였다. 그 결과, 풍속이 7.15 m/s 이상인 지점에서는 Repower-5 MW의 터빈이 높은 에너지 생산이 가능한 것으로 나타났으나 그 이하의 풍속에서는 G128-4.5 MW의 터빈이 유리한 것으로 나타났다. 10 m/s 이상의 풍속 출현율이 높은 마라도, 거제도 및 포항의 경우 REpower사의 5 MW급 해상풍력발전기 설치 시 설비이용률이 56.49%, 50.92%, 50.08%로 높게 나타났다.

경안천 유역 수질 및 이행평가 자료를 통한 임의적 오염총량관리제도 시행의 성과 분석 (Effects of the Voluntary Scheme of Total Maximum Daily Load based on Water Quality and Annual Evaluation data in the Gyeongan Watershed, South Korea)

  • 이범연;이창희
    • 한국물환경학회지
    • /
    • 제37권4호
    • /
    • pp.263-274
    • /
    • 2021
  • This study presents the achievements and limitations of the voluntary-based Total Maximum Daily Load (TMDL) through statistical analysis of water quality monitoring data and performance assessments of TMDL plans implemented in the Gyeongan watershed. The results clearly showed that responsible local governments complied the allocated TMDL and the designated water quality goals were successfully achieved in the required period. This was possible because the Ministry of Environment provided innovative incentives, such as, relaxations of the existing tight land-use regulations and full-scale financial aids for constructing and operating public treatment facilities to draw local government voluntary participation. However, a couple of problems which decreased the effectiveness and efficiency of the voluntary TMDL were identified. The different TMDL implementation schedules between upstream (Yongin) and downstream (Gwangju) governments caused delay in water quality improvement and exaggerated TMDL allocation to the local development which made excessive investment in the treatment facilities. Although it is not directly related to the voluntary scheme, technical methods for establishing and assessing the water quality goals should be improved so that the effects of flow conditions on water quality are properly assessed. We expect that results of this case study contribute to developing a more effective voluntary-based scheme for the implementation of the so-called 'tributary TMDL' in the future.