• Title/Summary/Keyword: Ankle joint angle

Search Result 282, Processing Time 0.023 seconds

Mid-Term Results of Modified Hoffman Procedure for Rheumatoid Forefoot Deformity (류마티스 전족부 변형에 대한 변형 Hoffman 술식의 중기 결과)

  • Kim, Yoon-Chung;Choi, Hyun Chul;Lee, Hyo Jin;Ahn, Jae Hoon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.484-490
    • /
    • 2021
  • Purpose: A rheumatoid forefoot deformity includes severe hallux valgus and claw toe of the four lateral toes. The authors intended to analyze the mid-term results of the modified Hoffman procedure for a rheumatoid forefoot deformity. Materials and Methods: Twenty-two feet of eighteen patients were followed up for more than two years after the modified Hoffman procedure. The mean age was 54.7 years, and the mean follow-up period was three years and four months. Clinically visual analogue scale (VAS) and American Orthopaedic Foot and Ankle Society (AOFAS) MP-IP score were analyzed preoperatively and postoperatively. The postoperative complications, the satisfaction of patients, and the presence of plantar callosity were also analyzed. Radiographically, the hallux valgus angle, the 1st intermetatarsal angle, the 1st interphalangeal angle, the 1st interphalangeal joint arthritic change after the operation, and the dorsiflexion angle and the time to union of the 1st metatarsophalangeal joint were analyzed. Results: Clinically, the VAS and AOFAS score were respectively improved from 7.1 points and 30.3 points preoperatively to 1.5 points and 83.1 points postoperatively (p<0.001). All patients were satisfied with the results. Plantar callosity disappeared in all cases. Radiographically, the mean hallux valgus angle, the 1st intermetatarsal angle, and the 1st interphalangeal angle changed from 52.8°, 13.3°, and 7.5° preoperatively to 16.2°, 8.7°, and 14.6° postoperatively (p<0.001). The mean dorsiflexion angle of the 1st metatarsophalangeal joint was 17.2° postoperatively. The mean time to radiographic union of the 1st metatarsophalangeal joint was 11.1 weeks. There were two cock-up deformities of the lesser toe, one wound problem, and two hallux interphalangeal joint arthritis as a complication. There were no cases of nonunion of the 1st metatarsophalangeal joint. Conclusion: The modified Hoffman procedure appears to be a safe and satisfactory procedure for a rheumatoid forefoot deformity.

Walking motion capture system for the biped-walking robot (이족 보행로봇의 걸음새구현을 위한 모셔냅쳐 시스템)

  • 최형식;김영식;전대원;김명훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.114-117
    • /
    • 2000
  • We developed a motion capture system to get angle data of human joints in walking mode. The data are used to coordinate the biped-walking robot developed in our laboratory. A pair of motion capture system is composed of three links with the ankle, knee, and pelvis joints. The system has six axes attached with potentiometers. We used an A/D converter was used to get digital data from joint angles. We filterd the data using the Butterworth 4th order digital filter, and simulated walking motion based on the data using the Matlab.

  • PDF

Kinematical Analysis of Up-Down Motion in Ski Simulator (스키 시뮬레이터 업-다운 동작의 운동학적 분석)

  • Nam, Chang-Hyun;Woo, Byung-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.41-49
    • /
    • 2007
  • This study was to investigate the kinematical analysis using ski simulator. Twelve people(six skilled, six unskilled) participated in the experiment. Each phase of motion time was slight differences between the skilled group and the unskilled group but not significant difference in statistics. In displacement of vertical on COG(Center of Gravity), left and right down motion showed significant difference between group. In velocity of horizontal on COG, both left and right down motion showed significant difference between group, and up motion of between down motion showed significant difference. In displacement of angle on ankle, knee, hip joint almost showed significant difference between group. Almost in body position was lower skilled group than unskilled group.

Effects of an 8-week Pilates Core Training on the Stability and Symmetry of the L-sit on Rings

  • Gil, Hojong;Yoo, Sihyun;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.383-390
    • /
    • 2016
  • Objective: Gymnastics on rings needs a high level of muscle strength with balance ability for controlling the body. A study on a new balance training program is necessary for elite gymnasts. Therefore, the purpose of this study was to investigate the effects of an 8-week pilates core-muscle training on balance ability and asymmetry index of the L-sit on the rings in male elite gymnasts. Method: Ten elite gymnasts (age: $20.6{\pm}0.7years$, height: $169.9{\pm}4.9cm$, weight: $65.4{\pm}5.6kg$, career duration: $20.6{\pm}0.7years$), who are students at K-university, participated in this study. Results: First, the range of the COM tended to decrease in the anterior-posterior direction. Second, the left hip joint angle and knee extension and ankle dorsiflexion angles significantly increased after the pilates training. Third, the ROM also increased. Fourth, the symmetry value increased in the hip angle, while the symmetry index in all joints of the ROM decreased. As a result, the pilates core-muscle training influenced the static balance ability during the L-sit on the rings. Conclusion: Accordingly, the pilates core-muscle training is suitable in enhancing the basic balance ability in gymnastics on rings.

Posture Stabilization Control of Biped Transformer Robot under Disturbances (이족 트랜스포머 로봇의 외란 대응 자세 안정화 제어)

  • Geun-Tae Kim;Myung-Hun Yeo;Jung-Yup Kim
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.3
    • /
    • pp.241-250
    • /
    • 2023
  • This paper describes the posture stabilization control of a bipedal transformer robot being developed for military use. An inverted pendulum model with a rectangular that considers the robot's inertia is proposed, and a posture stabilization moment that can maintain the body tilt angle is derived by applying disturbance observer and state feedback control. In addition, vertical force and posture stabilization moments that can maintain the body height and balance are derived through QP optimization to obtain the necessary torques and vertical force for each foot. The roll and pitch angles of the IMU sensor attached to the robot's feet are reflected in the ankle joint to enable flexible adaptation to changes in ground inclination. Finally, the effectiveness of the proposed algorithm in posture stabilization is verified by comparing and analyzing the difference in body tilt angle due to disturbances and ground inclination changes with and without algorithm application, using Gazebo dynamic simulation and a down-scale test platform.

Gait Analysis of a Pediatric-Patient with Femoral Nerve Injury : A Case Study (대퇴신경 손상 환아의 보행분석 : 사례연구)

  • Hwang, S.H.;Park, S.W.;Son, J.S.;Park, J.M.;Kwon, S.J.;Choi, I.S.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.2
    • /
    • pp.165-176
    • /
    • 2011
  • The femoral nerve innervates the quadriceps muscles and its dermatome supplies anteromedial thigh and medial foot. Paralysis of the quadriceps muscles due to the injury of the femoral nerve results in disability of the knee joint extension and loss of sensory of the thigh. A child could walk independently even though he had injured his femoral nerve severely due to the penetrating wound in the medial thigh. We measured and analyzed his gait performance in order to find the mechanisms that enabled him to walk independently. The child was eleven-year-old boy and he could not extend his knee voluntarily at all during a month after the injury. His gait analysis was performed five times (GA1~GA5) for sixteen months. His temporal-spatial parameters were not significantly different after the GA2 or GA3 test, and significant asymmetry was not observed except the single support time in GA1 results. The Lower limb joint angles in affected side had large differences in GA1 compared with the normal normative patterns. There were little knee joint flexion and extension motion during the stance phase in GA1 The maximum ankle plantar/dorsi flexion angles and the maximum knee extension angles were different from the normal values in the sound side. Asymmetries of the joint angles were analyzed by using the peak values. Significant asymmetries were found in GA1with seven parameters (ankle: peak planter flexion angle in stance phase, range of motion; ROM, knee: peak flexion angles during both stance and swing phase, ROM, hip: peak extension angle, ROM) while only two parameters (maximum hip extension angle and ROM of hip joint) had significant differences in GA5. The mid-stance valleys were not observed in both right and left sides of vertical ground reaction force (GRF) in the GA1, GA2. The loading response peak was far larger than the terminal stance peak of vertical ground reaction curve in the affected side of the GA3, GA4, GA5. The measured joint moment curves of the GA1, GA2, GA3 had large deviations and all of kinetic results had differences with the normal patterns. EMG signals described an absence of the rectus femoris muscle activity in the GA1 and GA2 (affected side). The EMG signals were detected in the GA3 and GA4 but their patterns were not normal yet, then their normal patterns were detected in the GA5. Through these following gait analysis of a child who had selective injuries on the knee extensor muscles, we could verify the actual functions of the knee extensor muscles during gait, and we also could observe his recovery and asymmetry with quantitative data during his rehabilitation.

A convergence study of the effects of asymmetric standing posture on knee joint position and lower extremity muscle activity in subjects with hyper-extended knee (무릎 과다 폄을 가진 대상자에게 비대칭 선 자세가 무릎 관절 위치와 근활성도에 미치는 영향에 대한 융합적 연구)

  • Jung, Sung-hoon;Ha, Sung-min
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.9
    • /
    • pp.63-68
    • /
    • 2019
  • The purpose of this study was to investigate the effect of hyper-extended knee and asymmetric standing posture on knee joint position and lower extremity muscle activity. Thirty-three voluntary participants participated and included sixty legs in the study. The sixty legs were divided into two groups: hyper-extended knee and normal group. The muscle activity and knee extension angle were measured. In the asymmetric standing posture, the knee joint extension angle and the muscle activity of the gastrocnemius were statistically significant between the normal group and the hyper-extended knee group. Based on the results, we confirmed that the asymmetric standing posture increases the hyper-extended knee. Therefore, it will contribute to the establishment of therapeutic guide for the subjects with hyper-extended knee to maintain the symmetrical standing posture, and future studies need to be conducted including the effects of the hip joint and ankle joints.

The Diagnostic Usefulness of Stress Radiography in Chronic Lateral Ankle Instability (만성 발목 관절 외측 불안정성의 진단에서 스트레스 방사선검사의 유용성)

  • Kim, Yong-Min;Cho, Byung-Ki;Kim, Dong-Soo;Choi, Eui-Sung;Shon, Hyun-Chul;Park, Kyoung-Jin;Kim, Dong-Hwan
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.35-40
    • /
    • 2011
  • Purpose: This study was performed to evaluate the diagnostic usefulness of ankle stress radiograph for evaluation of chronic lateral ankle instability. Materials and Methods: Among patients undergoing the modified-Brostrom procedure, 42 cases with complete rupture of the anterior talofibular ligament were enrolled in this study. Sixty Korean adults (120 cases) were recruited as the control group. Radiologic measurement of talar tilt and anterior talar translation was performed through stress radiographs using Telos device. We obtained the normal range of Korean adults, and used as a standard value for judgment of mechanical instability. We analyzed the sensitivity, specificity, positive and negative prediction value of ankle stress radiograph. Results: On ankle stress radiograph, normal range of talar tilt angle and anterior talar translation was below $8.3^{\circ}$, below 7.6mm. Talar tilt angle on varus stress radiograph showed 57% of sensitivity, 97% of specificity, 89% of positive and 86% of negative prediction value. Anterior talar translation on anterior drawer stress radiograph showed 69% of sensitivity, 97% of specificity, 91% of positive and 90% of negative prediction value. Conclusion: Ankle stress radiograph had a good specificity, positive and negative prediction value for the evaluation of mechanical instability. However it underestimated the mechanical instability of ankle joint. It must be remembered that normal stress radiograph does not exclude ankle instability.

  • PDF

Technical-note : Real-time Evaluation System for Quantitative Dynamic Fitting during Pedaling (단신 : 페달링 시 정량적인 동적 피팅을 위한 실시간 평가 시스템)

  • Lee, Joo-Hack;Kang, Dong-Won;Bae, Jae-Hyuk;Shin, Yoon-Ho;Choi, Jin-Seung;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.2
    • /
    • pp.181-187
    • /
    • 2014
  • In this study, a real-time evaluation system for quantitative dynamic fitting during pedaling was developed. The system is consisted of LED markers, a digital camera connected to a computer and a marker detecting program. LED markers are attached to hip, knee, ankle joint and fifth metatarsal in the sagittal plane. Playstation3 eye which is selected as a main digital camera in this paper has many merits for using motion capture, such as high FPS (Frame per second) about 180FPS, $320{\times}240$ resolution, and low-cost with easy to use. The maker detecting program was made by using Labview2010 with Vision builder. The program was made up of three parts, image acquisition & processing, marker detection & joint angle calculation, and output section. The digital camera's image was acquired in 95FPS, and the program was set-up to measure the lower-joint angle in real-time, providing the user as a graph, and allowing to save it as a test file. The system was verified by pedalling at three saddle heights (knee angle: 25, 35, $45^{\circ}$) and three cadences (30, 60, 90 rpm) at each saddle heights by using Holmes method, a method of measuring lower limbs angle, to determine the saddle height. The result has shown low average error and strong correlation of the system, respectively, $1.18{\pm}0.44^{\circ}$, $0.99{\pm}0.01^{\circ}$. There was little error due to the changes in the saddle height but absolute error occurred by cadence. Considering the average error is approximately $1^{\circ}$, it is a suitable system for quantitative dynamic fitting evaluation. It is necessary to decrease error by using two digital camera with frontal and sagittal plane in future study.

Biomechanical Comparison during Isolation Movement in B-boy and K-pop Dancers (B-boy와 K-pop 댄서 중심으로 한 분리 동작의 생체역학적 비교)

  • Jang, Young Kwan;Hong, Su Yeon;Jang, In Young
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.2
    • /
    • pp.91-99
    • /
    • 2017
  • The purpose of this study was to clarify the differences between the K-pop and B-boy dancers'characteristics based on the biomechanical variables through the isolation movement by independent variable t-test using spss 18.0. As a result, first, the CoM composite displacement of the K-pop dancer was larger than that of the B-boy(p<.05) in phase1 and phase2. Second, in phase2 and phase3, the movement speed of CoM was faster in K-pop dancer than in B-boy(p<.05). Third, in phase1, the planar angle between the body and pelvis was greater in the right planar angle of the K-pop dancer, while in the phase2 and phase3, the left planar angle of the B-boy was larger(p<.05). Fourth, the composite hip joint moments of B-boy were larger than those of K-pop in phase1, However, K-pop dancers showed greater moments in phase2, phase3 and phase4, and ankle joint moments in phase3(p<.05). Thus, even with the same isolation, we found that K-pop and B-boy dancers performed differently.