• Title/Summary/Keyword: Angular specificity

Search Result 10, Processing Time 0.027 seconds

Comparison of Radiography Findings and Magnetic Resonance Image Findings of Lumbar Spine Instability Patients (요추 불안정 환자에서 단순방사선 소견과 자기공명영상 소견의 비교)

  • Lee, In-Hee;Park, Hee-Joon;Jin, Jong-Sik;Lee, Jyung-Hyun;Kim, Yoon-Nyun
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.3
    • /
    • pp.41-46
    • /
    • 2007
  • Purpose: This study was to investigate how dose the radiography findings are to magnetic resonance (MR) image findings in the L5-S1 instability patients. The subjects of this study were comprised of eleven males and fifteen females, who had Lumbago and agreed with this research. Methods: Radiography and MR images of Lumbar spine were acquired respectively from subjects in conditions of maximum flexion and extension. The horizontal and angular displacements in lumabosacral spine radiography were used to assess the instability of lumbar spine. MR images were also used to evaluate the intervertebral disc abnormalities and change of bone marrow. Results: The results are as follows. 1. In the case of flexion transitional displacement proposed by Dupuis et al, the specificity and negative predictive value were good accuracy ($0.7{\sim}0.8$), and the negative predictive value was in average. In the case of extension displacement, the negative predictive value was about average ($0.6{\sim}0.7$), but the sensitivity, specificity and positive predictive value were below the poor (<0.6). On the other side, the specificity was about average but other things were below in the case of angular displacement. 2. In the case of flexion transitional displacement proposed by Dupuis et al., compared with the intervertebral disc abnormalities, the negative prediction value was excellent, the sensitivity good, and the specificity about average. In the case of extension, the negative prediction value was about average, but the other things were poor. On the other side the specificity and negative predictive value had good accuracy and the sensitivity and positive prediction value were below average in the case of angular displacement. Conclusion: The above results show that the radiography finding is sufficiently helpful to find the lumbar spine instability as an economic point of view.

  • PDF

Emergency Monitoring System Based on a Newly-Developed Fall Detection Algorithm

  • Yi, Yun Jae;Yu, Yun Seop
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.3
    • /
    • pp.199-206
    • /
    • 2013
  • An emergency monitoring system for the elderly, which uses acceleration data measured with an accelerometer, angular velocity data measured with a gyroscope, and heart rate measured with an electrocardiogram, is proposed. The proposed fall detection algorithm uses multiple parameter combinations in which all parameters, calculated using tri-axial accelerations and bi-axial angular velocities, are above a certain threshold within a time period. Further, we propose an emergency detection algorithm that monitors the movements of the fallen elderly person, after a fall is detected. The results show that the proposed algorithms can distinguish various types of falls from activities of daily living with 100% sensitivity and 98.75% specificity. In addition, when falls are detected, the emergency detection rate is 100%. This suggests that the presented fall and emergency detection method provides an effective automatic fall detection and emergency alarm system. The proposed algorithms are simple enough to be implemented into an embedded system such as 8051-based microcontroller with 128 kbyte ROM.

Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Ghandari, Farnaz;Hadinezhad, Arash
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.265-272
    • /
    • 2019
  • Purpose: To compare the diagnostic accuracy of cone-beam computed tomography (CBCT) with that of parallel(PPA) and oblique projected periapical(OPA) radiography for the detection of different types of peri-implant bone defects. Materials and Methods: Forty implants inserted into bovine rib blocks were used. Thirty had standardized bone defects(10 each of angular, fenestration, and dehiscence defects), and 10 were defect-free controls. CBCT, PPA, and OPA images of the samples were acquired. The images were evaluated twice by each of 2 blinded observers regarding the presence or absence and the type of the defects. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were determined for each radiographic technique. The 3 modalities were compared using the Fisher exact and chi-square tests, with P<0.05 considered as statistical significance. Results: High inter-examiner reliability was observed for the 3 techniques. Angular defects were detected with high sensitivity and specificity by all 3 modalities. CBCT and OPA showed similar AUC and sensitivity in the detection of fenestration defects. In the identification of dehiscence defects, CBCT showed the highest sensitivity, followed by OPA and PPA, respectively. CBCT and OPA had a significantly greater ability than PPA to detect fenestration and dehiscence defects(P<0.05). Conclusion: The application of OPA radiography in addition to routine PPA imaging as a radiographic follow-up method for dental implantation greatly enhances the visualization of fenestration and dehiscence defects. CBCT properly depicted all defect types studied, but it involves a relatively high dose of radiation and cost.

Muscle Fatigue according to Joint Angle and the Transfer Effect with Isometric Training (관절각도에 따른 근 피로도와 등척성 훈련 전이효과)

  • Song, Young-Hee;Kwon, Oh‐Yun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.4
    • /
    • pp.93-101
    • /
    • 2006
  • This study examined whether there is a transfer effect to other joint angles and the angular specificity of muscle fatigue after 6 weeks of isometric training of the vastus medialis. Twenty subjects were randomly assigned to 30° and 90° knee flexion groups and were trained at 80% maximal voluntary isometric contraction(MVIC) three times a week for 6 weeks. The pre-and post-training values of the 80% holding time(endurance time) of MVIC, the Fatigue Index(FI), and the MVIC at 30°, 60°, and 90° were compared. After isometric training for 6 weeks, in the 30° knee flexion group, FI decreased significantly(p<0.05) only at 30°, which was the training angle; there was no change at other angles. By contrast, in the 90° knee flexion group, FI decreased significantly(p<0.05) at both the trained angle and at the other angles, indicating a transfer effect of training. MVIC did not increase significantly(p<0.05) at any trained angle in either the 30° or 90° knee flexion groups after 6 weeks of isometric training, neither did the 80% holding time of MVIC differ significantly compared with pre-training in either group. These findings suggest that training at 90° of knee flexion is more effective than training at 30° of knee flexion for obtaining a training transfer effect on muscle fatigue in the vastus medialis.

Sleep apnea detection from a single-lead ECG signal with GAF transform feature-extraction through deep learning (GAF 변환을 사용한 딥 러닝 기반 단일 리드 ECG 신호에서의 수면 무호흡 감지)

  • Zhou, Yu;Lee, Seungeun;Kang, Kyungtae
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.07a
    • /
    • pp.57-58
    • /
    • 2022
  • Sleep apnea (SA) is a common chronic sleep disorder that disrupts breathing during sleep. Clinically, the standard for diagnosing SA involves nocturnal polysomnography (PSG). However, this requires expert human intervention and considerable time, which limits the availability of SA diagnoses in public health sectors. Therefore, ECG-based methods for SA detection have been proposed to automate the PSG procedure and reduce its discomfort. We propose a preprocessing method to convert the one-dimensional time series of ECG into two-dimensional images using the Gramian Angular Field (GAF) algorithm, extract temporal features, and use a two-dimensional convolutional neural network for classification. The results of this study demonstrated that the proposed method can perform SA detection with specificity, sensitivity, accuracy, and area under the curve (AUC) of 88.89%, 81.50%, 86.11%, and 0.85, respectively. Our experimental results show that SA is successfully classified by extracting preprocessing transforms with temporal features.

  • PDF

Discrimination of Fall and Fall-like ADL Using Tri-axial Accelerometer and Bi-axial Gyroscope

  • Park, Geun-Chul;Kim, Soo-Hong;Baik, Sung-Wan;Kim, Jae-Hyung;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • A threshold-based fall recognition algorithm using a tri-axial accelerometer and a bi-axial gyroscope mounted on the skin above the upper sternum was proposed to recognize fall-like activities of daily living (ADL) events. The output signals from the tri-axial accelerometer and bi-axial gyroscope were obtained during eight falls and eleven ADL action sequences. The thresholds of signal vector magnitude (SVM_Acc), angular velocity (${\omega}_{res}$), and angular variation (${\theta}_{res}$) were calculated using MATLAB. When the measured values of SVM_Acc, ${\omega}_{res}$, and ${\theta}_{res}$ were compared to the threshold values (TH1, TH2, and TH3), fall-like ADL events could be distinguished from a fall. When SVM_Acc was larger than 2.5 g (TH1), ${\omega}_{res}$ was larger than 1.75 rad/s (TH2), and ${\theta}_{res}$ was larger than 0.385 rad (TH3), eight falls and eleven ADL action sequences were recognized as falls. When at least one of these three conditions was not satisfied, the action sequences were recognized as ADL. Fall-like ADL events such as jogging and jumping up (or down) have posed a problem in distinguishing ADL events from an actual fall. When the measured values of SVM_Acc, ${\omega}_{res}$, and ${\theta}_{res}$ were applied to the sequential processing algorithm proposed in this study, the sensitivity was determined to be 100% for the eight fall action sequences and the specificity was determined to be 100% for the eleven ADL action sequences.

Design and Implementation of Robot-Based Alarm System of Emergency Situation Due to Falling of The Eldely (고령자 낙상에 의한 응급 상황의 4족 로봇 기반 알리미 시스템 설계 및 구현)

  • Park, ChulHo;Lim, DongHa;Kim, Nam Ho;Yu, YunSeop
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.781-788
    • /
    • 2013
  • In this paper, we introduce a quadruped robot-based alarm system for monitoring the emergency situation due to falling in the elderly. Quadruped robot includes the FPGA Board(Field Programmable Gate Array) applying a red-color tracking algorithm. To detect a falling of the elderly, a sensor node is worn on chest and accelerations and angular velocities measured by the sensor node are transferred to quadruped robot, and then the emergency signal is transmitted to manager if a fall is detected. Manager controls the robot and then he judges the situation by monitoring the real-time images transmitted from the robot. If emergency situation is decided by the manager, he calls 119. When the fall detection system using only sensor nodes is used, sensitivity of 100% and specificity of 98.98% were measured. Using the combination of the fall detection system and portable camera (robot), the emergency situation was detected to 100 %.

Threshold-based Pre-impact Fall Detection and its Validation Using the Real-world Elderly Dataset (임계값 기반 충격 전 낙상검출 및 실제 노인 데이터셋을 사용한 검증)

  • Dongkwon Kim;Seunghee Lee;Bummo Koo;Sumin Yang;Youngho Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.384-391
    • /
    • 2023
  • Among the elderly, fatal injuries and deaths are significantly attributed to falls. Therefore, a pre-impact fall detection system is necessary for injury prevention. In this study, a robust threshold-based algorithm was proposed for pre-impact fall detection, reducing false positives in highly dynamic daily-living movements. The algorithm was validated using public datasets (KFall and FARSEEING) that include the real-world elderly fall. A 6-axis IMU sensor (Movella Dot, Movella, Netherlands) was attached to S2 of 20 healthy adults (aged 22.0±1.9years, height 164.9±5.9cm, weight 61.4±17.1kg) to measure 14 activities of daily living and 11 fall movements at a sampling frequency of 60Hz. A 5Hz low-pass filter was applied to the IMU data to remove high-frequency noise. Sum vector magnitude of acceleration and angular velocity, roll, pitch, and vertical velocity were extracted as feature vector. The proposed algorithm showed an accuracy 98.3%, a sensitivity 100%, a specificity 97.0%, and an average lead-time 311±99ms with our experimental data. When evaluated using the KFall public dataset, an accuracy in adult data improved to 99.5% compared to recent studies, and for the elderly data, a specificity of 100% was achieved. When evaluated using FARSEEING real-world elderly fall data without separate segmentation, it showed a sensitivity of 71.4% (5/7).

Clinical Application and Limitations of the Capsular Pattern (관절낭 패턴의 임상적 적용과 한계)

  • Lim, Wootaek
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.13-17
    • /
    • 2021
  • A normal range of motion is essential for performing activities of daily living. The capsular pattern is the proportional motion restriction in range of motion during passive exercises due to tightness of the joint capsule. Although the capsular pattern is widely referred to in clinical practice, there is no scientific evidence to support the concept. In this review, the appropriateness of the capsular pattern for evaluation of joint pathology was assessed. In the Textbook of Orthopaedic Medicine written by Cyriax, the capsular pattern did not specify how much reduction in angular motion is considered motion restriction. As the definition proposed initially was unclear, different methods have been used in previous studies investigating capsular pattern. In addition, the capsular pattern described all the major joints of the human body, but only the hip joint, knee joint, and shoulder joint were studied in experimental studies. Sensitivity and specificity were reported in one study and were meaningful in specific pathologies (loss of extension to loss of flexion). There was no consensus on the reliability and validity. In summary, the capsular pattern suggested by Cyriax or Kaltenborn is not supported or applies only to certain conditions. Various components around a joint complement each other and provide stability to the joint. It is recommended that the therapist perform multiple assessments rather than rely on a single assessment when evaluating joints.

COMPARATIVE STUDY ON THE HORIZOTAL MEASUREMENTS OF SKELETAL CLASS III MALOCCLUSION USING THE ROC ANALYSIS (ROC 분석을 이용한 골격성 III급 부정교합의 수평계측방법간 비교연구)

  • Choi, Hee-Young;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.153-163
    • /
    • 1995
  • In this study, Receiver Operating Characteristic(ROC) analysis was used to evaluate the ability of cephalometric measurements to identify patients with Class III malocclusions. ROC analysis is the method for determining the validity of a diagnostic measure and for evaluating the relative value of diagnostic tests. The sample consisted of 496 patients with malocclusion. Class III malocclusion is defined as the dental relationship for which The mesiobuccal groove of the lower first molar is deviated mesially from the mesiobuccal cusp of the upper first molar. Of the total sample of 496 patients, 245 had Class III malocclusions. 16 cephalometric measurements were selected, each of which was treated as a diagnostic test. The ROC curves were generated for each cephalometric measurement with intervals of $1.0^{\circ}$ for angular measurements, 1.0mm for linear measurements. The area under the ROC curves was measured for direct comparison among different diagnostic tests. The results were as follows; 1. The 'Wits' appraisal was found to be a better diagnostic criterion for the presence of Class III malocclusion than any other commonly'used cephalometric measurement. 2. AB plane angle, ANB angle, App-Bpp distance, AF-BF distance, APDI, Distance of point A and Pog to N perpendicular, maxillomandibular differential had high diagnostic value. 3. Cephalometric measurements which evaluate the position of the mandible had moderate diagnostic value. 4. Cephalometric measurements related to the maxilla discriminated least between patients with and without Class III malocclusion.

  • PDF