• Title/Summary/Keyword: Angular measurement

Search Result 342, Processing Time 0.035 seconds

Behavior of angular distortion in butt joint welding of thin plate structure (맞대기 용접시의 각변형 거동에 관한 연구)

  • 배강열;김희진
    • Journal of Welding and Joining
    • /
    • v.6 no.3
    • /
    • pp.21-26
    • /
    • 1988
  • The behavior of angular distortion in butt joint wleding of thin plate structure is investigated with an experimental model and partially with a computational model. The experimental model studying the effects of specimene size and degree of restraint on the angular distorion offers a good method for analyzing the behavior of the distrotion. In addition, the distrotion during welding was demonstrated by both experimental measurement and numericla prediciton. The facts evealed in this study are as follows : 1) distrotion angles were changed with variations of specimene wldth. 2) With the restraint, angular distrotion was reduced to 20% to that of free joint. 3) After the restraint being removed, the effect of restraint was also remained. 4) Same heat input per unit thickness caused same amount of distortion. 5) The mode of angular distortion was expected to be changed with expected to be changed with time, i.e. convex movement during heating and concave one during cooling.

  • PDF

Quantification of the Bradykinesia in Idiopathic Parkinson's Disease Patients using Angular velocity measurement system: The Correlation between angular velocity and UPDRS scores in motor examination part (각속도 측정시스템을 이용한 특발성 파킨슨병 환자의 완서증 정량화:운동기능검사 항목에 대한 UPDRS 점수와의 상관관계 분석)

  • Kim, J.W.;Lee, K.M.;Eom, G.M.;Kwon, D.Y.;Koh, S.B.;Park, K.W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2009.06a
    • /
    • pp.71-72
    • /
    • 2009
  • PDF

Tomographic Reconstruction of Asymmetric Soot Structure from Multi-angular Scanning (다각 주사법을 이용한 비대칭 매연분포의 재구성)

  • Lee, Sang-Min;Hwang, Jun-Young;Chung, Suk-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.8 no.3
    • /
    • pp.24-30
    • /
    • 2003
  • A convolution algorithm combined with Fourier transformation has been applied to the tomographic reconstruction of asymmetric soot structure to identify the local soot volume fraction distribution. Line-of-sight integrated data from light extinction measurement with multi-angular scanning formed basic information for the deconvolution. Multi-peak following interpolation technique was applied to obtain the effect of increasing number of scanning angles. Height-by-height reconstructed soot volume fraction distribution was compared with laser-induced incandescence signals.

  • PDF

ANGULAR CLUSTERING OF FIR-SELECTED GALAXIES IN THE AKARI ALL-SKY SURVEY

  • Pollo, A.;Takeuchi, T.T.;Suzuki, T.L.;Oyabu, S.
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.4
    • /
    • pp.343-344
    • /
    • 2012
  • We present the first measurement of the angular two-point correlation function for AKARI $90{\mu}m$ point sources, detected outside of the Milky Way plane and selected as candidates for extragalactic sources. This is the first measurement of the large-scale angular clustering of galaxies selected in the far-infrared after IRAS. We find a positive clustering signal in both hemispheres extending up to ~ 40 degrees, without any significant fluctuations at larger scales. The observed correlation function is well fitted by a power law function. However, southern galaxies seem to be more strongly clustered than northern ones and the difference is statistically significant. The reason for this difference - technical or physical - is still to be found.

A Transfer Alignment Method considering a Data Latency Compensation for an Inertial Navigation System in High Dynamic Applications (고기동 환경에서 관성항법장치의 시간지연 보상 전달정렬 기법)

  • Lee, Hyung-Sub;Han, Kyung-Jun;Lee, Sang-Woo;Yu, Myung-Jong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1742-1747
    • /
    • 2015
  • An improved transfer alignment method for a strap-down inertial navigation system (SDINS) is presented here. The alignment accuracy in conventional method is vulnerable to the data latency of a Master INS (MINS) in high maneuverable platforms. We propose a time delay compensation equation considering higher-order terms in the attitude measurement equation of the Kalman filter. The equation incorporates additional information including angular rate, angular acceleration and linear acceleration from the MINS. Simulation results show that the transfer alignment accuracy is significantly improved in the high dynamic environment by incorporating the latency compensation technique.

Angular-based Measurement for Quantitative assay of Albumin in three-dimensional Paper-based analytical Device (회전각도를 이용한 알부민 농도 측정용 3차원 종이 칩)

  • Kim, Dong-Ho;Jeong, Seong-Geun;Lee, Chang-Soo
    • Korean Chemical Engineering Research
    • /
    • v.58 no.2
    • /
    • pp.286-292
    • /
    • 2020
  • This study presents an angular-based measurement on three-dimensional paper-based analytical devices (3D-PADs) for quantitative detection of albumin without using an image analyzer. We demonstrate a simple quantitative and straightforward approach based on the angle of the discolored area as detection criteria. 3D-PADs are rapidly fabricated by the wax-printing and laminating process. The 3D-PADs are treated with citrate buffer and tetrabromophenol blue to react with albumin in a sample solution. Dropping sample solution into sample pad in the 3D-PAD, fluid flows toward the assay zone laterally and vertically by capillary action. We find that the change of angle of the discolored area correctly reflects the concentration of albumin and is reliable determinant for the measurement of the albumin concentration. It is the first demonstration of angular-based detection as a simple, inexpensive, and equipment-free approach for point-of-care diagnosis.

Evaluation for Performance of a Military Radiation Detecter PDR-1K : Focused on Dependence of Angular and Energy (군사용 방사선 계측기 PDR-1K 반응도 평가 : 방향 및 에너지 의존성을 중심으로)

  • Park, Wonseok;Choi, Junhyuk;Jung, Doyoung;Kim, Jango;Min, Byungin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.300-305
    • /
    • 2017
  • In this paper, we performed a evaluation for angular and energy dependence of military radiation detector PDR-1K. Its measuring range is divided into two section, low and high, and each range has a GM tube separately owing to broad scale. We observed a change in relative angular reactivity within 0.928 ~ 1.188 in low range and within 0.743 ~ 1.000 in high range from $-90^{\circ}$ to $+90^{\circ}$. The evaluation for energy dependence appeared a relative reactivity within 0.892 ~ 1.000 above 83 keV. This means PDR-1K isn't possible to use below 83 keV of radiation energy. It is possible to provide response information to user and to increase reliability of radiation measurement through this paper.

Development and performance test of a complex laser interferometer for simultaneously measuring displacement and 2-D angles (변위 각도 동시 측정용 복합 레이저 간섭계의 제작과 특성 분석)

  • Kim J.W.;Kim J.A.;Kang C.S.;Eom T.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.573-576
    • /
    • 2005
  • A compact linear and angular displacement measurement device was developed by combining a Michelson interferometer and an autocollimator to characterize the movement of a precision stage. A Michelson interferometer and an autocollimator are typical devices for measuring linear and angular displacement, respectively. By controlling the polarization of reflected beam from the target mirror of the interferometer, some part of light was retro-reflected to the light source and the reflected beam was used for angle measurement. The interferometer and the autocollimator use the same optic axis and the target mirror can be easily and precisely aligned orthogonal to the optic axis by monitoring the autocollimator s signal. The autocollimator was designed for angular resolution of 0.1 arcsec and dynamic range of 60 arcsec. The nonlinearity error of interferometer was minimized by trimming the gain and offset of the photodiode signals. Through the experiments, we evaluate the performance of measurement device and discuss its applications.

  • PDF

Study on Uncertainty Factors of Head Vibration Measurements

  • Cheung, Wan-Sup;Ryu, Je-Dam;Hong, Dong-Pyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.101-104
    • /
    • 2004
  • This paper addresses uncertainty issues encountered recently in measuring head vibration using the conventional 6-axis or 9-axis bite-bar Those conventional bite-bars are shown to present insufficient information to measure a complete 6 degree-of-freedom motion of head vibration. In order to overcome such limit, a theoretical measurement model that consists of four 3-axis linear accelerometers is suggested (Theoretical backgrounds presented in this paper shall have been addressed in the international congress of ICA 2004 in this April). It is shown to enable the direct measurement of three angular acceleration components and six angular velocity-dependent nonlinear terms. In audition to the three linear acceleration terms, those nine angular motion-dependent ones are found to make it possible to evaluate the general head vibration for a given position. To examine the feasibility of the proposed method, a newly designed 12-axis bite-bar was developed. Detailed experimental results obtained using the developed 12-axis bite-bar are illustrated in the presentation of this paper, which illustrates what amount of measurement accuracy provides. But, this paper provides more detailed experimental data and extended uncertainty factors.

  • PDF