• Title/Summary/Keyword: Angular Error

Search Result 313, Processing Time 0.029 seconds

Improving Orbit Determination Precision of Satellite Optical Observation Data Using Deep Learning (심층 학습을 이용한 인공위성 광학 관측 데이터의 궤도결정 정밀도 향상)

  • Hyeon-man Yun;Chan-Ho Kim;In-Soo Choi;Soung-Sub Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.3
    • /
    • pp.262-271
    • /
    • 2024
  • In this paper, by applying deep learning, one of the A.I. techniques, through angle information, which is optical observation data generated when observing satellites at observatories, distance information from observatories is learned to predict range data, thereby increasing the precision of satellite's orbit determination. To this end, we generated observational data from GMAT, reduced the learning data error of deep learning through preprocessing of the generated observational data, and conducted deep learning through MATLAB. Based on the predicted distance information from learning, trajectory determination was performed using an extended Kalman filter, one of the filtering techniques for trajectory determination, through GMAT. The reliability of the model was verified by comparing and analyzing the orbital determination with angular information without distance information and the orbital determination result with predicted distance information from the model.

Geocentric parallax measurements of Near-Earth Asteroid using Baselines with domestic small-size observatories (국내 소형천문대 기선을 이용한 근접 소행성 지심시차 측정)

  • Jeong, Eui Oan;Sohn, Jungjoo
    • Journal of the Korean earth science society
    • /
    • v.37 no.7
    • /
    • pp.398-407
    • /
    • 2016
  • We cooperated with four domestic educational astronomical observatories to construct a baseline and perform simultaneous observations to determine the geocentric parallax, distance, and motion of 1036 Ganymed, an Amor asteroid near the Earth. Observations were made on the day when simultaneous observations were possible from September to November 2011. Measured distances of 1036 Ganymed were 0.394 AU on Sept. 26, 0.365 AU on Oct. 11, and 0.340 AU on Oct. 25, respectively, which were within the error range as compared with the measured distances proposed by the US Jet Propulsion Laboratory. The 1036 Ganymed showed a tilting motion during the observation period, and the tangential angular velocities were measured at $0.037-0.052^{{\prime {\prime}}\;sec^{-1}$. Through this study, it was shown that the simultaneous observations among educational astronomical observations can obtain distance measurements with an error range of about 5% for asteroids near 0.4 AU. And it expected to be used as a research & education program emphasizing collaborative observation activities based on a network between observatories.

Computer Interface for the Disabled Using Gyro-sensors and Artificial Neural Network (자이로 센서와 인공신경망을 이용한 장애인용 컴퓨터)

  • 안용식;엄광문;김철승;허지운;나유진
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.411-419
    • /
    • 2003
  • This paper aims at developing 'gyro-mouse' which provides decent and comfortable human-computer interface that supports the usage of such software as an internet-browser in PC for the people paralyzed in upper limbs. This interface operates on information collected from head movement to get the cursor control. The interface is composed of two modules. One is hardware module in which the head horizontal and vertical angular velocities are detected and transmitted into PC. The other is a PC software that translates the received data into movement and click signals of the mouse. The ANN (artificial neural network) learns the quick nodding pattern of each user as click input so that it can provide user-friendly interface. The performance of the system was evaluated by three indices that are click recognition rate. error in cursor position control. and click rate of the moving target box. The performance result of the gyro-mouse was compared with that of the optical-mouse to assess the efficiency of the gyro-mouse. The average click recognition rate was 93%, average error in cursor position control was 1.4∼5 times of optical mouse. and the click rate with 50 pixels target box was 40%(30 clicks/min) to that of optical mouse. The click rate increased monotonously with the number of trial from 35% to 44%. The suggested system is expected to provide a new possibility to communicate with the society.

Efficient Skew Estimation for Document Images Based on Selective Attention (선택적 주의집중에 의한 문서영상의 효율적인 기울어짐 추정)

  • Gwak, Hui-Gyu;Kim, Su-Hyeong
    • Journal of KIISE:Software and Applications
    • /
    • v.26 no.10
    • /
    • pp.1193-1203
    • /
    • 1999
  • 본 논문에서는 한글과 영문 문서 영상들에 대한 기울어짐 추정(skew estimation) 알고리즘을 제안한다. 제안 방법은 전체 문서 영상에서 텍스트 요소들이 밀집되어 있는 영역을 선별하고, 선별된 영역에 대해 허프 변환을 적용하는 선택적 주의집중(selective attention) 방식을 채택한다. 제안 방법의 기울기 추정 과정은 2단계로 구성되는데, coarse 단계에서는 전체 영상을 몇 개의 영역으로 나누고 동일한 영역에 속하는 데이타들간의 연결 각도를 계산하여 각 영역별 accumulator에 저장한다. accumulator에 저장된 빈도치를 기준으로 $\pm$45$^{\circ}$범위 내에서 최대 $\pm$1$^{\circ}$의 오차를 가진 각 영역별 기울기를 계산한 후, 이들 중 최대 빈도값을 갖는 영역을 선정하고 그 영역의 기울기 각도를 문서 영상의 대략적인 기울기 각도로 결정한다. Refine 단계에서는 coarse 단계에서 선정된 영역에 허프 변환을 적용하여 정확한 기울기를 계산하는데, coarse 단계에서 추정한 기울기의 $\pm$1$^{\circ}$범위 내에서 0.1$^{\circ}$간격으로 측정한다. 이와 같은 선택적 주의집중 방식을 통해 기울기 추정에 소요되는 시간 비용은 최소화하고, 추정의 정확도는 최대화 할 수 있다.제안 방법의 성능 평가를 위한 실험은 다양한 형태의 영문과 한글 문서 영상 2,016개에 적용되었다. 제안 방법의 평균 수행 시간은 Pentium 200MHz PC에서 0.19초이고 평균 오차는 $\pm$0.08$^{\circ}$이다. 또한 기존의 기울기 추정 방법과 제안 방법의 성능을 비교하여 제안 방법의 우수성을 입증하였다.Abstract In this paper we propose a skew estimation algorithm for English and Korean document images. The proposed method adopts a selective attention strategy, in which we choose a region of interest which contains a cluster of text components and then apply a Hough transform to this region. The skew estimation process consists of two steps. In the coarse step, we divide the entire image into several regions, and compute the skew angle of each region by accumulating the slopes of lines connecting any two components in the region. The skew angle is estimated within the range of $\pm$45 degree with a maximum error of $\pm$1 degree. Next we select a region which has the most frequent slope in the accumulators and determine the skew angle of the image roughly as the angle corresponding to the most frequent slope. In the refine step, a Hough transform is applied for the selected region within the range of $\pm$1 degree along the angle computed from the coarse step, with an angular resolution of 0.1 degree. Based on this selective attention strategy, we can minimize the time cost and maximize the accuracy of the skew estimation.We have measured the performance of the proposed method by an experiment with 2,016 images of various English and Korean documents. The average run time is 0.19 second on a Pentium 200MHz PC, and the average error is $\pm$0.08 degree. We also have proven the superiority of our algorithm by comparing the performance with that of other well-known methods in the literature.

A Feasibility study on the Simplified Two Source Model for Relative Electron Output Factor of Irregular Block Shape (단순화 이선원 모델을 이용한 전자선 선량율 계산 알고리듬에 관한 예비적 연구)

  • 고영은;이병용;조병철;안승도;김종훈;이상욱;최은경
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2002
  • A practical calculation algorithm which calculates the relative output factor(ROF) for irregular shaped electron field has been developed and evaluated the accuracy of the algorithm. The algorithm adapted two-source model, which assumes that the electron dose can be express as sum of the primary source component and the scattered component from the shielding block. Original two-source model has been modified in order to make the algorithm simpler and to reduce the number of parameters needed in the calculation, while the calculation error remains within clinical tolerance range. The primary source is assumed to have Gaussian distribution, while the scattered component follows the inverse square law. Depth and angular dependency of the primary and the scattered are ignored ROF can be calculated with three parameters such as, the effective source distance, the variance of primary source, and the scattering power of the block. The coefficients are obtained from the square shaped-block measurements and the algorithm is confirmed from the rectangular or irregular shaped-fields used in the clinic. The results showed less than 1.0 % difference between the calculation and measurements for most cases. None of cases which have bigger than 2.1 % have been found. By improving the algorithm for the aperture region which shows the largest error, the algorithm could be practically used in the clinic, since one can acquire the 1011 parameter's with minimum measurements(5∼6 measurements per cones) and generates accurate results within the clinically acceptable range.

  • PDF

Seq2Seq model-based Prognostics and Health Management of Robot Arm (Seq2Seq 모델 기반의 로봇팔 고장예지 기술)

  • Lee, Yeong-Hyeon;Kim, Kyung-Jun;Lee, Seung-Ik;Kim, Dong-Ju
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.3
    • /
    • pp.242-250
    • /
    • 2019
  • In this paper, we propose a method to predict the failure of industrial robot using Seq2Seq (Sequence to Sequence) model, which is a model for transforming time series data among Artificial Neural Network models. The proposed method uses the data of the joint current and angular value, which can be measured by the robot itself, without additional sensor for fault diagnosis. After preprocessing the measured data for the model to learn, the Seq2Seq model was trained to convert the current to angle. Abnormal degree for fault diagnosis uses RMSE (Root Mean Squared Error) during unit time between predicted angle and actual angle. The performance evaluation of the proposed method was performed using the test data measured under different conditions of normal and defective condition of the robot. When the Abnormal degree exceed the threshold, it was classified as a fault, and the accuracy of the fault diagnosis was 96.67% from the experiment. The proposed method has the merit that it can perform fault prediction without additional sensor, and it has been confirmed from the experiment that high diagnostic performance and efficiency are available without requiring deep expert knowledge of the robot.

Reverse engineering technique on the evaluation of impression accuracy in angulated implants (경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법)

  • Jung, Hong-Taek;Lee, Ki-Sun;Song, So-Yeon;Park, Jin-Hong;Lee, Jeong-Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.261-270
    • /
    • 2021
  • Purpose. The aim of this study was (1) to compare the reverse engineering technique with other existing measurement methods and (2) to analyze the effect of implant angulations and impression coping types on implant impression accuracy with reverse engineering technique. Materials and methods. Three different master models were fabricated and the distance between the two implant center points in parallel master model was measured with different three methods; digital caliper measurement (Group DC), optical measuring (Group OM), and reverse engineering technique (Group RE). The 90 experimental models were fabricated with three types of impression copings for the three different implant angulation and the angular and distance error rate were calculated. One-way ANOVA was used for comparison among the evaluation methods (P < .05). The error rates of experimental groups were analyzed by two-way ANOVA (P < .05). Results. While there was significant difference between Group DC and RE (P < .05), Group OM had no significant difference compared with other groups (P > .05). The standard deviations in reverse engineering were much lower than those of digital caliper and optical measurement. Hybrid groups had no significant difference from the pick-up groups in distance error rates (P > .05). Conclusion. The reverse engineering technique demonstrated its potential as an evaluation technique of 3D accuracy of impression techniques.

Study on the Optimum Positions of Theodolite Station for Control Surveying (기준점측량(基準點測量)을 위한 데오돌라이트 관측점(觀測點)의 최적위치(最適位置)에 관한 연구(研究))

  • Yeu, Bock Mo;Lee, Jae Ki;Park, Hong Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.4 no.4
    • /
    • pp.95-103
    • /
    • 1984
  • This paper is a study on improving the accuracy of control points by suggesting angular requirements which make geometric conditions to be optimum. For this purpose, a equation, by which the accuracy of control point coordinates measured in an arbitrary station can be estimated, is derived. This equation is integrated and average standard error of the coordinates is computed, so that the optimum location of observatory station is determined. In the case of triangulation, a regular triangle has been generally considered as the best geometric condition, but because the precision of each side is different, the $52.77^{\circ}$ isosceles triangle is founded to be the best one. Also in trigonometric leveling, the geometric condition is founded to be optimum when the base angle of a isosceles triangle is $45^{\circ}$. In control surveying for close-range photogrammetry the optimum relation between base length($B_0$) and object distance($D_0$) can be founded to be as follow; $D_0=0.357587-0.357967B_0+0.308555B_0{^2}$.

  • PDF

Color Restoration Method Using the Dichromatic Reflection Model for Low-light-level Environments (저조도 환경에 적합한 이색도 반사 모델을 이용한 색 복원 기법)

  • Lee, Woo-Ram;Jun, WooKyoung;Jun, Byoung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7324-7330
    • /
    • 2014
  • Color distortion of the dark images acquired under a low-light-level environment with a weak light source can be cause of the performance decreation of various vision systems. Therefore, recovering the original color of the images is an important process for enhancing the performance of the system. For this, this study proposes a color restoration method using a dichromatic reflection model. This paper assumes that the dark images can be classified into two parts affected by specular or diffuse reflection. Two different color constancy methods were then applied to the images to remove the effects of each reflection and two images were created as a result. The resulting images produced a one color-corrected image by combining with different weights according to the position in the images. For the performance evaluation, this paper used a synthesized image, and considered the Euclidean distance and angular error as an evaluation factor. In addition, a performance comparison was performed with the existing various color constancy method to achieve the objectivity of evaluation. The experimental results showed that the proposed method can be a more suitable solution for color restoration than the existing method.

Vibration Analysis of SAR Antenna Reflectors During Satellite Maneuver (위성 기동 시 SAR 안테나 반사판에 발생하는 진동 분석)

  • Kim, Tae-Hyun;Kim, Dae-Yeon;Suh, Jong-Eun;Han, Jae-Hung;Lee, Jae-Eun;Jung, Hwa-Young
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.3
    • /
    • pp.225-231
    • /
    • 2020
  • Recently, there has been an increasing demand for SAR satellite as it can be operated regardless of the weather condition. In general, main reflector of the SAR is formed of multiple deployable panels to increase performance in the constrained payload envelope. By nature, deployable structure lacks structural stiffness and it is vulnerable to external disturbances and excitation. In particular, SAR satellites may have high levels of vibration occurring at the antenna reflecting surface due to higher angular rate requirements. During image capturing it is important to keep high surface accuracy of the reflector for the quality of images. In this research, a performance degradation of deployable SAR antenna due to structural deformation is analyzed. Panels for main reflectors are assumed to be flexible structures and multi-body simulation environment is established. Then, deflection of the panel is calculated while the satellite performs maneuvers. In addition, antenna gain and beam pointing error are analyzed to determine how these deflections affect antenna performance and mission.