• Title/Summary/Keyword: Angle of plate

Search Result 1,125, Processing Time 0.032 seconds

An Analysis of the Reinforced Concrete Circular Ring Sector Plates with Arbitrary Boundary Conditions (I) - Part I Effects of open-angle - (임의의 경계조건을 갖는 철근 콘크리트 선형판의 해석 -제1보 개각의 영향)

  • 조진구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.33 no.2
    • /
    • pp.94-103
    • /
    • 1991
  • This study was carried out to investigate the engineering characteristics of the R.C circular ring sector plate with various boundary conditions and then to propose a rational and paraical method for application of finite element method to R.C structures. The stiffness matrix of the circular ring sector plate was obtained by using the multi-base coordinate system in which the base-coordinate systems were constructed for each nodal point of the quadrilateral element in order to reflect the complicated boundary conditions conveniently and correctly. The R.C element stiffness matrix was constructed by adding the stiffness coefficients of the steel-bar element into the plate bending element stiffness matrix. Herein, the steel-bar element was treated as the common beam element. Using the above method, the effects of steel-bar can be considered without increasing of the numbers of element and nodal points.

  • PDF

Performance Analysis of the Swash Plate Type Compressor using CO2 Refrigerant (CO2용 사판식 압축기 성능 해석)

  • Lee, Geon-Ho;Park, Ik-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.564-569
    • /
    • 2005
  • Recently, from the viewpoint of global wanning, natural gas CO2 is considered as a main refrigerant for hot water system. The characteristics of CO2 is not toxic, not flammable, high pressure, and high refrigerating capacity. Also it is widely available as a byproduct of industrial processes. This paper describes the performance analysis program of the swash plate type compressor using CO2 refrigerant. Estimates of the refrigerant flow rate, compression work, discharge temperature and volumetric, compressor efficiencies of the CO2 swash plate type compressor are obtained from the various design parameter such as the inclination angle of the swash plate, discharge hole area and suction hole area.

  • PDF

A Study on the Flow Characteristics of a Two - Dimensional Oblique Plate Impinging Jet (경사진 평판에서 2차원 충돌 제트의 유동 특성에 관한 연구)

  • 윤순현;김경문;김대성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.1
    • /
    • pp.37-42
    • /
    • 1997
  • Turbulent flow characteristics of a two - dimensional oblique plate impinging jet(OPIJ) were experimentally investigated. The jet mean velocity and turbulent intensity profIles were also measured along the plate. The jet Reynolds numbers(Re, based on the nozzle width)ranged from 10, 000 to 35, 000, the nozzle - to - plate distance(H/B) from 2 to 16, and the oblique angle (a) from 60 to 90 degree. It has been found that the stagnation point shifted toward the minor flow region as the oblique angle decreases and the position of the stagnation point nearly coin¬cided with that of the maximum turbulent intensity.

  • PDF

An Experimental Study on Condensation Heat Transfer Characteristics and Pressure Drop of Plate Heat Exchangers using the Alternative Refrigerant R410A (대체 냉매 R410A를 적용한 판형열교환기의 응축열전달 특성 및 압력강하에 대한 실험적 연구)

  • Kim, Y.H.;Han, D.H.;Lee, K.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.220-225
    • /
    • 2001
  • The plate heat exchanger is characterized. by low pressure drop and high heat transfer coefficient. The experimental study has been performed on the condensation heat transfer and pressure drop characteristics of the plate heat exchangers in this study. In the present study, a brazed type plate heat exchanger was investigated at a chevron angle of $45^{\circ},\;55^{\circ},\;and\;70^{\circ}$ with R410A. Condensation temperatures were varied from $20^{\circ}C\;and\;30^{\circ}C$, and mass flux was ranged from $13{\sim}34\;kg/m^{2}s$ with constant heat flux ($=5\;kw/m^{2}$). The heat transfer coefficient and pressure drop increased with the chevron angle. Average condensation heat transfer coefficients and pressure drops are decreased with increasing condensation tempeature.

  • PDF

Experiments on Condensation Heat Transfer and Pressure Drop in Plate Heat Exchangers with Different Chevron Angles (판형 열교환기의 세브론각에 따른 응축열전달 및 압력강하 실험)

  • 김윤호;한동혁;이규정
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1141-1148
    • /
    • 2001
  • Experiments on the condensation heat transfer and pressure drop in the brazed type plate heat exchangers are performed with refrigerants R410A/R22. To investigate the geometric effect, plate heat exchangers with the same pitch and height but different $45^{\circ},\;35^{\circ}and\;20^{\circ}$ chevron angles are used. Varying the mass flux of refrigerant (13~34 kg/$m^2$), the condensing temperatures ($20^{\circ}C\;and\;30^{\circ}C$) and the vapor quality (from 0.9 to 0.15) at the same constant heat flux ($5kW/m^2$), the condensation heat transfer coefficients and pressure drops are measured. The heat transfer coefficients decrease slightly with increasing the condensing temperature at a given mass flux in all plate heat exchangers. The pressure drop increases with increasing the mass flux and the quality and decreasing the condensing temperature and the chevron angle.

  • PDF

DESIGN OF TRANSBUCCAL TROCAR TIP USED IN MANDIBULAR ANGLE FRACTURES (하악골 골절시 사용되는 TRANSBUCCAL TROCAR TIP의 새로운 고안)

  • Ahn, Byoung-Keun;Rhee, Gun-Ju;Han, Ho-Jin;Park, Hyoung-Tae
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.87-92
    • /
    • 1989
  • Transbuccal trocar has been an established method of fixation for the bone plate in the case of mandibular angle fracture. Other than extraoral approaches, this transbuccal approach has many advantages in the treatment of the fracture of mandibular angle. These advantages are as follows ; (1) Damage to the facial nerve branches is minimal. (2) Less postoperative scar is formed. (3) Good vision of occlusion can be easily obtained on the entire operation. (4) Shorter operation time is needed. But, in the clinical procedure of plate fixation, it is has a difficulty in manipulation of the plate and correction of position. To solve these problems, we designed and used a trocar tip which can be easily attached to the trocar, and could make an improvement in the clinical procedures.

  • PDF

Optimum Design of the Laminated Composite Sandwich Plate Structure of Honeycomb Core considering Vibration Characteristics (복합적층 하니콤 코어형 샌드위치 판무구조물의 진동특성을 고려한 최적설계)

  • Seo, J.;Hong, D. K.;Ahn, C. W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.710-715
    • /
    • 1997
  • This paper deals with the analysis of the optimum value of honeycomb core considering variable design parameter. As thickness and height of core rises in design parameter, natural frequency of laminated composite plate increases. The angle-phy has the maximum value when the plate of honeycomb core join to opposite direction. This paper shows that the natural frequency of CFRP was higher than that of GFRP and mode shapes were various at angle-ply.

  • PDF

An analysis of uniformly loaded RIC skew-Plates with all edges built-in (II) - Part 2 effects of edge ratio - (등분포 하중을 받는 4변고정 철근콘크리트 사판의 해석(II) -제2보 변장비의 영향-)

  • 조진구;이원준
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.28 no.1
    • /
    • pp.75-82
    • /
    • 1986
  • In this paper. the characteristics of mechanical behaviour due to various edge-ratio of uniformly loaded clamped skew-~plates has been described. In this study, the skew-plate was discretized using 8-noded isoparametric element and Mindlin's plate theory was adapted in finite element formulation. The edge-ratio 0.5,0.8,1.0,1.2,1.5,2.0 and 2.5 were considered. Hence, five cond- itions of the skew-angle, the seven levels of edge ratio were tried. When the edge-ratio was 2.5 or the edge-ratio was 2.0 and the skew-angle was less than 45 degree, the behaviour of the uniformly loaded the skew-plate with all edges clamped was independent of the skew-angle.

  • PDF

Clinical and Radiologic Results Comparing the Periarticular Proximal Humerus Locking Plate and Polarus Nail for Displaced Proximal Humerus Fractures

  • Min, Young-Kyoung;Lee, Seung-Jun;Gwak, Heui-Chul;Kang, Sang-Woo;Suh, Kuen-Tak
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.208-216
    • /
    • 2017
  • Background: This study compared the clinical and radiological outcomes of the single calcar screw plate and Polarus nail techniques for the treatment of the proximal humerus fractures. Methods: Seventy-two patients diagnosed with displaced proximal humerus fracture were enrolled for the study. Of these, 50 patients underwent the locking plate surgery with a single calcar screw (plate group), whereas 22 patients underwent the Polarus nail surgery (nail group). The plate group was further divided into plate 1 group (with medial support), and plate 2 group (without medial support). The radiological and functional results of both groups were compared to the nail group. Results: The ${\alpha}$ angle 1 year after surgery was significantly different between plate 1 and plate 2, and plate 2 and nail groups (p=0.041, p=0.043, respectively). The ratio that does not satisfy the reference value of ${\gamma}$ angle was 2.8% in plate 1, 7.1% in plate 2 and 22.7% in nail group (p=0.007); there was a significant difference between plate 1 and nail group, and plate 2 and nail group (p=0.014, p=0.033, respectively). Conclusions: No significant differences were observed in the clinical results between locking plate and Polarus nail. However, in the plate 2 group and nail group, the rate of failure to maintain reduction during the 1-year period after surgery was statistically and significantly higher than the plate 1 group (level of evidence: level IV, case series, treatment study).

Simplified Ground-type Single-plate Electrowetting Device for Droplet Transport

  • Chang, Jong-Hyeon;Kim, Dong-Sik;Pak, James Jung-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.402-407
    • /
    • 2011
  • The current paper describes a simpler ground-type, single-plate electrowetting configuration for droplet transport in digital microfluidics without performance degradation. The simplified fabrication process is achieved with two photolithography steps. The first step simultaneously patterns both a control electrode array and a reference electrode on a substrate. The second step patterns a dielectric layer at the top to expose the reference electrode for grounding the liquid droplet. In the experiment, a $5{\mu}m$ thick photo-imageable polyimide, with a 3.3 dielectric constant, is used as the dielectric layer. A 10 nm Teflon-AF is coated to obtain a hydrophobic surface with a high water advancing angle of $116^{\circ}$ and a small contact angle hysteresis of $5^{\circ}$. The droplet movement of 1 mM methylene blue on this simplified device is successfully demonstrated at control voltages above the required 45 V to overcome the contact angle hysteresis.