• Title/Summary/Keyword: Angle of curvature

Search Result 414, Processing Time 0.026 seconds

Clinical Study for Chuna Treatment on Neck Pain Patient with Hypolordotic Cervical Spine (과소전만된 경항통 환자에 대한 추나요법 임상연구)

  • Ryu, Heon-Sik;Jeon, Seong-Ha;Park, Dong-Soo;Lee, Soo-Keel
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.1 no.2
    • /
    • pp.11-20
    • /
    • 2006
  • Objectives: The aim of this study is to investigate clinical effects of Chuna treatment on the neck pain patient with hypolordotic cervical spine. Methods: From June 2006 to August 2006, 20 cases of neck pain patient with hypolordotic cervical spine were divided into 2 groups. Control group(n=10) was treated only acupuncture therapy, and sample group(n=10) was treated Chuna after acupuncture therapy same as control group. Degrees of pain were measured with Visual Analogue Scale(VAS), and the change of cervical curvature was assessed Depth of cervical curve, Method of Jochumsen, and Angle of cervical curve. Results: 1. After 3th and 5th treatment, there was statistical significance between control and sample group in VAS. 2. After 5th treatment, there was not statistical significance between control and sample group in Depth of cervical curve, Method of Jochumsen, and Angle of cervical curve. Conclusions: On treating the neck pain patient with hypolordotic cervical spine, Chuna treatment is more effective than only acupuncture therapy in reducing neck pain, but Chuna treatment for short-term is not more effective than only acupuncture therapy in restoring cervical curvature.

  • PDF

The posture correction effect of functional clothing to prevent turtle neck syndrome (거북목 증후군 예방용 기능성 의류의 자세 교정 효과)

  • Kim, Hyunsook;Chun, Jongsuk;Jee, Jungwoo
    • The Research Journal of the Costume Culture
    • /
    • v.24 no.3
    • /
    • pp.358-366
    • /
    • 2016
  • This study was performed to measure the posture correction effect of wearing ergonomic experimental clothing. Two types of experimental clothing (A, B) were developed. Both of them reinforced the muscles surrounding the spine. Experimental clothing A was developed by reflecting the shape and position of the pectoralis major muscle, abdominal muscle, and latissimus dorsi muscle. Experiment clothing B was developed by reflecting the integrated form of those muscles. Subjects were males in their 20s~30s (n=32). They were divided into two groups based on their acromion distance (AD): the turtle neck syndrome group (n=16, AD=3.81cm) and the normal group (n=16, AD=1.27cm). The correction of body posture was detected by three index values: change of the cervical curvature angle, horizontal distance between the seventh cervical vertebra and tragion, and AD. The comfort and tightness of the clothing were also measured. The results showed that both types of experimental clothing corrected body posture and that turtle neck syndrome can be prevented by wearing these types of posture correcting clothing. Two index values were decreased: cervical curvature angle ($0.31{\sim}1.32^{\circ}$) and horizontal distance between seventh cervical vertebra and tragion (0.22~0.31cm). The chest was also stretched. The comfort was rated as good for both types of experimental clothing. These results indicate that the experimental clothing had a posture correction effect without any discomfort for daily living.

A Study on the Influence of Lumbar Lordosis and Intervertebral Disc Angle by Obesity (비만에 의한 허리뼈 전만과 추간판 각도의 영향에 관한 연구)

  • Kwak, Jong Hyeok;Choi, Min Gyeong;Kim, Neung Gyun;Kim, A Yeon;Kim, Gyeong Rip
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.235-243
    • /
    • 2020
  • Lumbar Lordosis Angle (LLA) is an index that can be used to evaluate the curvature of the lumbar vertebrae. It can measure the structural stability of the lumbar spine and the stability of each segment of the vertebral column at the intervertebral disc angle (IDA). Especially, our data shows it is found to be a strong positive correlation between obesity and the angle of lordosis for lumbar vertebrae. Also, the reason for the large IDA in the case of obesity seems to be the result of the weakening of anatomical structure as well as the gravity effect. And, the obesity interferes with normal sagittal balance and fails to maintain a straight posture with minimal energy. Therefore, the obesity can be an important factor in causing back pain by changing the lumbar lordosis.

Determination of optimal parameters for perforated plates with quasi-triangular cutout by PSO

  • Jafari, Mohammad;Hoseyni, Seyed A. Mahmodzade;Chaleshtari, Mohammad H. Bayati
    • Structural Engineering and Mechanics
    • /
    • v.60 no.5
    • /
    • pp.795-807
    • /
    • 2016
  • This study tries to examine the effect of different parameters on stress analysis of infinite plates with central quasi-triangular cutout using particle swarm optimization (PSO) algorithm and also an attempt has been made to introduce general optimum parameters in order to achieve the minimum amount of stress concentration around this type of cutout on isotropic and orthotropic plates. Basis of the presented method is expansion of analytical method conducted by Lekhnitskii for circular and elliptical cutouts. Design variables in this study include fiber angle, load angle, curvature radius of the corner of the cutout, rotation angle of the cutout and at last material of the plate. Also, diagrams of convergence and duration time of the desired problem are compared with Simulated Annealing algorithm. Conducted comparison is indicative of appropriateness of this method in optimization of the plates. Finite element numerical solution is employed to examine the results of present analytical solution. Overlap of the results of the two methods confirms the validity of the presented solution. Results show that by selecting the aforementioned parameters properly, less amounts of stress can be achieved around the cutout leading to an increase in load-bearing capacity of the structure.

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

Effects of Corrugation Angle on Local Heat/Mass Transfer in Wavy Duct of Heat Exchanger (열교환기 내부 유로의 꺾임각 변화에 따른 국소 열/물질전달 특성 고찰)

  • Jang, In-Hyuk;Hwang, San-Dong;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.7
    • /
    • pp.789-799
    • /
    • 2004
  • An experimental study is conducted to investigate the effects of duct corrugation angle on heat/mass transfer characteristics in wavy ducts of a primary surface heat exchanger application. Local heat/mass transfer coefficients on the wavy duct sidewalls are determined by using a naphthalene sublimation technique. The corrugation angles(${\alpha}$) of the wavy ducts are 145$^{\circ}$, 130$^{\circ}$, 115$^{\circ}$ and 100$^{\circ}$. And the Reynolds numbers based on the duct hydraulic diameter vary from 300 to 3,000. The results show that at the low Re(Re $\leq$1000), the secondary vortices called Taylor-Gortler vortices perpendicular to the main flow direction are generated due to effect of duct curvature. By these secondary vortices, high heat/mass transfer regions are formed on both pressure-side and suction-side walls. At the high Re(Re $\geq$ 1000), these secondary flows are vanished with helping flow transition to turbulent flow and the regions which show high heat/mass coefficients by flow reattachment are formed on suction side. As corrugation angle decreases, the local peak Sh induced by Taylor-Gortler vortices increase at Re $\leq$1000. At high Re(Re $\geq$ 1000), by the existence of different kind of secondary flows called Dean vortices, non-uniform Sh distribution appears along spanwise direction at the narrow corrugation angle (${\alpha}$=100$^{\circ}$). Average Sh also increase by the enhanced effect of secondary vortices and flow reattachment. More pumping power (pressure loss) is required with the smaller corrugation angle due to the enhancement of flow instability.

Clinical Study on Idiopathic Scoliosis with Massotherapy (추나요법을 시행한 특발성 척추측만증 환자 30례에 관한 임상적 고찰)

  • Yang Ki-Young;Hong Kwon-Eui;Lee Hyun;Lee Byung-Ryul;Shin Young-Il
    • Journal of Acupuncture Research
    • /
    • v.18 no.6
    • /
    • pp.27-34
    • /
    • 2001
  • Objective : The purpose of this study was to inspect the effect of Massotherapy on idiopathic scoliosis patients, utilizing Cobb's angle to determine the degree of curvature progression in the thoracic and lumbar regions. Methods : To obtain this result, we examinated 30 case of parents who visit Dept. of Acupuncture and Moxibustion Oriental Medical Hospital. Taejon University. with idiopathic scoliosis. We observe their age, sex, symptoms and Cobb's angle. Results : As a result of this examination, we detected the fact that it's difficult to treat isiopathic scoliosis fundamentally. But, Their symptoms are improved. So it is necessary to treat scoliosis actively with massotherapy . Conclusion : We want to be put this knowledge to practical use on treating Scoliosis and think the study like this must be go on continuously.

  • PDF

Reflection of Plane Shock Wave over Concave and Convex Walls (오목, 볼록면에서 평면충격파의 반사)

  • JEON, Heung-Kyun;KWON, Jin-Kyung;KWON, Soon-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1473-1480
    • /
    • 1999
  • In the case of Impingement of plane moving shock wave over concave or convex double wedges (pseudo-stationary flow) and cylindrical walls (truly non-stationary flow), it Is expected that there are transitions from regular reflection to Mach reflection or vice versa In shock wave reflections. In these connections, it is necessary to verify the various of reflection process and transition angle for the reflection problems In double wedges, and to verify the transition angle, effects of curvature radius and initial wall angle on it for the reflection problems In cylindrical walls. Especially, we focused our attention to confirm the existence of hysteresis phenomenon induced by the different transition processes, and Neumann paradox, which is a small discrepancy between theoretical and experimental transition angles. Experiments were carried out by using the shock tube of $6{\times}6cm^2$, and high speed photographic technique consisted of delay unit, triggering system, light source of Xe lamp and so on was used for flow visualization.

Correct Posture Guidance System using 3-axis Acceleration Sensor for Scoliosis Patient (3축 가속도 센서를 이용한 자세 교정 유도 시스템)

  • An, Yang-Soo;Kim, Keo-Sik;Seo, Jeong-Hwan;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.220-224
    • /
    • 2010
  • In this study, we designed a device for consecutively observing position, utilizing 3-axises acceleration sensor. This method offer to check his or her wrong position and developed could to help derived a position appliance. And, we developed a Cobb's angle value in three dimensional using 3-axises acceleration sensor. A proposed device with integrated accelerometers, which can detect postural changes in terms of curvature variation of the spine in the sagittal and coronal planes, has been developed with intention to facilitate posture training. The proposed device was evaluated with 3 normal subjects daily activities. We evaluated the performance of our designed device as calculating the correlation coefficients and mean errors between the angle measured by an electro-goniometer and that estimated by a gravity accelerometer and verified the accuracy and sensitivity. The results showed that the angle obtained from the proposed device revealed a linear characteristic at the range of $\pm60^{\circ}$(correlation coefficient 0.99, error range $\pm2^{\circ}$). We demonstrated that our device could detect the changes of the motion in upper trunk accurately. Also, our device showed good potential for treatment of the patients with scoliosis and prevention of the unbalance position during a daily life.

Turbulent Heat Transfer of an Oblique Impinging Jet on a Concave Surface (오목표면에 분사되는 경사충돌제트의 난류열전달 현상에 관한 연구)

  • 임경빈;최형철;이세균;최상경;김학주
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.4
    • /
    • pp.371-380
    • /
    • 2000
  • The turbulent heat transfer from a round oblique impinging jet on a concave surface were experimentally investigated. The transient measurement method using liquid crystal was used in this study. In this measurement, a preheated wall was suddenly exposed to an impinging jet while recording the response of liquid crystals to measure surface temperature. The Reynolds numbers were 11000, 23000 and 50000, nozzle-to-surface distance ratio was from 2 to 10 and the surface angles were a =$0^{\circ}\;15^{\circ},\;30^{\circ}and\;40^{\circ}$. Correlations of the stagnation point Nusselt numbers with Reynolds number, jet-to-surface distance ratio and dimensionless surface angle, which account for the surface inclined angle, are presented. The maximum Nusselt numbers, in this experiment, occurred in the direction of upstream. The displacement of the maximum Nusselt number from the stagnation point increases with increasing surface angle or decreasing nozzle-to-surface distance. In this experiment, the maximum displacement is about 0.7 times of the jet nozzle diameter when surface curvature, D/d is 10.

  • PDF