• 제목/요약/키워드: Angle measurements

검색결과 1,336건 처리시간 0.026초

Cone-Beam Computed Tomographic Assessment of Temporomandibular Joint Morphology in Patients with Temporomandibular Joint Disc Displacement and in Healthy Subjects: A Pilot Study

  • Choi, Hang-Moon;Park, Moon-Soo
    • Journal of Oral Medicine and Pain
    • /
    • 제41권2호
    • /
    • pp.41-47
    • /
    • 2016
  • Purpose: The purpose of this study was to analyze the size and morphology of mandibular condyle and mandibular fossa between temporomandibular joint (TMJ) disc displacement (DD) patients and healthy subjects using cone-beam computed tomography (CBCT). Methods: Twenty healthy subjects and twenty TMJ DD patients participated in this study respectively. We made five measurements in mandibular condyle (medio-lateral dimension, antero-posterior dimension, condyle height, intercondylar distance and intercondylar angle) and two measurements in mandibular fossa (mandibular fossa depth and articular eminence angle) using CBCT image. Results: There was no difference between two groups in medio-lateral dimension. In case of antero-posterior dimension, average of healthy controls was larger than that of TMJ DD patients, but that was not significant statistically. There were no significant differences between two groups in condyle height. Comparing intercondylar distance and intercondylar angle between two groups, there was no significant difference between two groups. In comparison of mandibular fossa depth and articular eminence angle, there was no significant difference between two groups. Conclusions: We couldn't find any definite relationship between TMJ morphology and TMJ DD.

Research on a Method for the Optical Measurement of the Rifling Angle of Artillery Based on Angle Error Correction

  • Zhang, Ye;Zheng, Yang
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.500-508
    • /
    • 2020
  • The rifling angle of artillery is an important parameter, and its determination plays a key role in the stability, hit rate, accuracy and service life of artillery. In this study, we propose an optical measurement method for the rifling angle based on angle error correction. The method is based on the principle of geometrical optics imaging, where the rifling on the inner wall of the artillery barrel is imaged on a CCD camera target surface by an optical system. When the measurement system moves in the barrel, the rifling image rotates accordingly. According to the relationship between the rotation angle of the rifling image and the travel distance of the measurement system, different types of rifling equations are established. Solving equations of the rifling angle are deduced according to the definition of the rifling angle. Furthermore, we added an angle error correction function to the method that is based on the theory of dynamic optics. This function can measure and correct the angle error caused by the posture change of the measurement system. Thus, the rifling angle measurement accuracy is effectively improved. Finally, we simulated and analyzed the influence of parameter changes of the measurement system on rifling angle measurement accuracy. The simulation results show that the rifling angle measurement method has high measurement accuracy, and the method can be applied to different types of rifling angle measurements. The method provides the theoretical basis for the development of a high-precision rifling measurement system in the future.

비폐쇄를 보이는 III급 부정교합아동의 기도 공간 형태와 안모 골격 형태와의 상관관계 연구 (A study on the correlation between airway space and facial morphology in Class III malocclusion children with nasal obstruction)

  • 정호림;정동화;차경석
    • 대한치과교정학회지
    • /
    • 제37권3호
    • /
    • pp.192-203
    • /
    • 2007
  • 본 연구는 비폐쇄를 보이는 III급 부정교합아동에서, 기도 공간의 형태와 안모 골격 형태 사이의 상관관계를 평가하였다. III급 부정교합을 보이며, 비폐쇄 소견을 보여 이비인후과로 의뢰된 환아 100명의 초진 측모 두부 규격 방사선 사진에서 상 인두기도 공간(upper PAS), 하 인두기도 공간(lower PAS), 편도의 크기, 구개-혀 공간을 측정하여 기도 공간 형태를 분석하였으며, 통상적인 계측점을 사용하여 안면 골격 분석을 시행하여 기도 공간 형태 계측항목과 안면 골격분성 항목간의 상관관계를 연구하여 다음과 같은 결과를 얻었다. Upper PAS는 ramal height, SNA, SNB, PFH, FHR, facial plane angle 항목과 양의 상관관계를 보였으며, saddle angle, articular angle, gonial angle의 sum, SN-GoGn, Y-axis to SN, FMA 항목과 음의 상관관계를 보였다. Lower PAS는 genial angle, FMA와 양의 상관관계를 보였으며, articular angle, facial depth, PFH, FHR와 음의 상관관계를 보였다. 편도의 크기는 PCBL, ramal height, Mn. body length, Mn. body length to ACBL, facial depth, facial length, PFH, AFH와 양의 상관관계를 보였다. 구개-혀 공간은 saddle angle, articular angle, genial angle의 합, facial length, AFH, FMA, LFH와 양의 상관관계를 보였으며, IMPA, overbite와 음의 상관관계를 보였다.

High-Frequency Bistatic Scattering from a Corrugated Sediment Surface

  • Cho, Hong-Sang;La, Hyoung-Sul;Yoon, Kwan-Seob;Na, Jung-Yul;Kim, Bong-Chae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제25권2E호
    • /
    • pp.60-68
    • /
    • 2006
  • High-frequency bistatic scattering measurements from a corrugated surface were made in an acoustic water tank. First the azimuthal scattering pattern was measured from an artificially corrugated surface which has varying impedance. The corrugated surface was installed both transverse to the direction of incident wave and longitudinal to the direction of incident wave. The angle between the corrugated surface and the direction of the incident wave was about $45^{\circ}$. Second, the scattering strengths were measured from the flat sediment and the corrugated sediment. A critical angle of about $37^{\circ}$ was calculated in the acoustic water tank. The measurements were made at three fixed grazing angles: $33^{\circ}$ (lower than critical angle), $37^{\circ}$ (critical angle), and $41^{\circ}$ (higher than critical angle). The scattering angle and the grazing angle are equal in each measurement. Frequencies were from 50 kHz to 100 kHz with an increment of 1 kHz. The corrugated sediment was made transverse to the direction of the incident wave. The first measurement indicates that the scattering patterns depend on the relations between the corrugated surface and the direction of the incident wave. In the second measurement, the data measured from the flat sediment were compared to the APL-UW model and to the NRL model. The NRL model's output shows more favorable comparisons than the APL-UW model. In case of the corrugated sediment, the model and the measured data are different because the models used an isotropic wave spectrum of sediment roughness in the scattering calculations. The isotropic wave spectrum consists of $w_2$ and ${\gamma}_2$. These constants derived from sediment names or bulk size. The model which used the constants didn't consider the effect of a corrugated surface. In order to consider a corrugated surface, the constants were varied in the APL-UW model.

개교(開咬)와 과개교합(過蓋咬合)의 골격요소에 관(關)한 두부방사선(頭部放射線) 계측학적(計測學的) 연구(硏究) (A ROENTGENOCEPHALOMETRIC STUDY ON THE SKELETAL FACTORS IN OPEN-BITE AND DEEP-BITE)

  • 박진성
    • 대한치과교정학회지
    • /
    • 제9권1호
    • /
    • pp.133-140
    • /
    • 1979
  • The author compared patients showing two extremes of incisor vertical relationship to find out differences in craniofacial morphology which might influence face height and incisor overbite. The subjects consisted of 53 open-bite cases and the same number of deep-bite cases. The results were as follows: 1. On the average, the lower face height was significantly greater in open-bite cases than in deep-bite cases. 2. In open-bite cases, gonin-menton length was significantly greater than in deep-bite cases. In deep-bite cases, anterior cranial base length and posterior cranial base length were significantly greater in open-bite cases. 3. The jaw angle was significantly greater in open-bite cases. 4. The gonion-menton-nasion angle was significantly greater in deep-bite cases. 5. From geometric standpoint, the increase of jaw and joint angle would increase lower face height, but these two showed negative correlation. 6. The sizes of the jaw and joint angle might be factors of open-bite or deep-bite, but these were not the only variables that determined lower face height. 7. In open-bite cases, there was a closer correlationship between lower face height and the other linear measurments than in deep-bite cases. In deep-bite cases, there was a closer correlationship between lower face height and the other angular measurements than in open-bite cases. 8. Considering both linear and angular measurements of facial polygon, all contributed significantly to the lower face height. The nonsignificant variables were jaw and joint angle in open-bite cases, and anterior cranial base length, jaw angle, and joint angle in deep-bite cases.

  • PDF

Producing a Semi-automatic Profile Measuring Program (SPMP) in Body Silhouette for Elderly Women

  • Oh, HeeKyung;Maruta, Naomi;Nagashima, Shinobu;Hirokawa, Taeko
    • 한국의류산업학회지
    • /
    • 제14권6호
    • /
    • pp.968-976
    • /
    • 2012
  • This study presents a new method called the SPMP (Semi-automatic profile measuring program) to efficiently measure body shape in elderly women. SPMP can automatically measure the angle of axis (19 items), surface (17 items), lengths (14 items), heights (16 items), widths (13 items), and depth (6 items). In total these 85 items are automatically measured very quickly, accurately, and easily after manually marking an initial 36 points. The utility of SPMP was evaluated using several tests. When SPMP measuring results were compared with manual methods (using a ruler and protractor) in thirteen elderly women using a paired t-test, there was no significant difference found between them. Furthermore, when measurements from SPMP were compared with actual measurement results in selected items from seven elderly women's measurements, smaller mean differences were found than those defined by ISO 20685, with the exception of the abdominal area which moves easily with breathing. Seven independent measurements of a single elderly woman were made by seven students using SPMP, and the values of coefficient of variation were less than 5% for all but 8 items. Finally, this study analyzed the correlation of all 85 item measurements, and found that the angle from the upper chest to the neck towards the front in the axis curved forward as much as the axis angle from the thigh to the waist (r=-0.876, $^{**}p$ < 0.01) bent backwards in elderly women. This detailed analysis helps to understand age-related changes in body posture, and will be useful in future studies.

하악운동 회전량과 과로의 형태에 관한 연구 (A Study on the Amount of Mandibular Rotation and Pattern of Condylar Path)

  • Kyung-Soo Han;You-Me Lee
    • Journal of Oral Medicine and Pain
    • /
    • 제21권2호
    • /
    • pp.369-382
    • /
    • 1996
  • The author performed this study to investige the relationship between condylar movements recorded with Pantronicⓡ and mandibular rotational torque movements with BioEGNⓡ. For this study 56 patients with Temporomandibular disorders(TMD) and 30 dental students without any masticatory signs and symptoms were selected as patients group and control group, respectively. The items recorded with Pantronicⓡ(Denar Corp., USA) were immediate side-shift, progressive side-shift, angle of orbiting path, protrusive path and PRI. BioEGNⓡ(Bioelectric gnathography, Bioresearch Inc., USA) were used to measure the amounts of mandibular rotational torque movements in frontal and horizontal plane, and the distance of mandibular translation at incisal area. Amount of mandibular rotational torque movement depicted between the condyles was automatically analysed by angle and difference in frontal and horizontal plane. The obtained data were processed with SAS program and the conclusion of this study were as follows : 1. Mean values of items between patients group and control group in Pantronic measurements were not significantly different except in left protrusive path and in Pantronic Reproducibility Index(PRI). There were no significant difference of condylar paths by preferred chewing side and affected side between the two groups. 2. The amount of mandibular rotational torque movements were differed in frontal angle and difference on protrusion, and in frontal and in horizontal difference on left excursion between the two groups. But the amounts of translatory movements were actually same on all eccentric movements. 3. The amount of mandibular rotational torque movements with splint mere almost not changed from those without splint, with the exception of in horizontal measurements on protrusion. 4. The correlations of items between in Pantronic measurements and in BioEGN measurements wert not consistently, significant, however, generally the ISS related significantly with horizontal torque movement positively, and with frontal torque movement negatively on the contrary, the PSS showed positive correlation with frontal torque movement, and negative correlation with horizontal torque movement.

  • PDF

순열ㆍ구개열 환자 부모와 정상 성인의 두개안면 형태에 관한 비교 연구 (A COMPARATIVE STUDY OF CRANIOFACIAL MORPHOLOGY OF PARENTS WITH AND WITHOUT CLEFT LIP AND/OR PALATE CHILDREN)

  • 임숙영;고광준
    • 치과방사선
    • /
    • 제23권1호
    • /
    • pp.103-114
    • /
    • 1993
  • The purpose of this study was to determine whether any difference existed in craniofacial morphology between parents of children with cleft lip and/or palate and parents of children without cleft lip and/or palate as well as the characteristics of craniofacial morphology in parents of children with cleft lip and/or palate. Thirty three measurements of the various regions of cranium and face were obtained from lateral cephalometric radiograms in parents of 28 children with cleft lip and palate, 18 children with cleft lip, and 22 children with cleft palate. There were 28 couples and 40 single parents in this sample. There were 92 individuals including 41 males and 51 females. The measurements were compared with those in control subjects, including 40 adult males and 40 adult females, who had no history of craniofacial abnormalities. The total sample was compared for the sex independently. The obtained results were as follows. 1. In the cranium, both parents of cleft children had significantly shorter posterior cranial base length(S-Ba). 2. In the upper face, a significantly shorter anteroposterior length of maxilla(A'-Ptm'), particularly in the anterior region (A'-K), anterior facial depth(A-SBaL), posterior facia! height(Ptm'-SNL) and relation of subnasale to the cranial base (∠BaN'Sn) were noted in fathers of cleft children. But, all measurements were not found to be significantly different between experimental group and control group in all mothers. 3. In the lower face, both parents of cleft children showed a significantly greater Y axis angle(∠NSGn) and ramal plane angle(∠SNL-RP) in fathers of cleft children. Thus both patents showed a posteriorly rotation of mandible. The thickness of the lower lip(B-B') was significantly thicker in fathers of cleft children. 4. In the facial profile, a significantly shorter posterior facial height(S-Go) and greater angle of soft tissue facial convexity (∠BaN'Pog') were noted in the fathers of cleft children. But, all measurements were not found to be significantly different between experimental group and control group in all mothers.

  • PDF

Another Glenoid Measurements for Shoulder Surgery

  • Jeong, Yeon-Seok;Yum, Jae-Kwang;Lee, Jun-Seok
    • Clinics in Shoulder and Elbow
    • /
    • 제21권4호
    • /
    • pp.179-185
    • /
    • 2018
  • Background: We analyzed the angle between the glenoid anterior surface and glenoid axis, the range of the glenoid apex and the location of the glenoid apex for assistance during shoulder surgery. Methods: Sixty-two patients underwent a computed tomography of the shoulder with a proximal humerus fracture. In the range of the glenoid apex, the ratios of the distribution of triangles with a Constant anterior and posterior area of the glenoid were measured. The location of glenoid apex was confirmed as the percentage of the position with respect to the upper part of the glenoid with the center of the part, analyzed the angle between the glenoid anterior surface and glenoid axis was measured. Results: The angle between the glenoid anterior surface and glenoid axis was $19.80^{\circ}{\pm}3.88^{\circ}$. The location of the glenoid apex is $60.36%{\pm}9.31%$, with the upper end of the glenoid as the reference. The range of the glenoid apex was $21.16%{\pm}4.98%$. When the height of the glenoid becomes smaller, the range of the glenoid apex tends to become larger (p=0.001) and the range of the glenoid apex becomes wider (p=0.001) as the glenoid width narrows. Conclusions: We believe the anatomical measurements of the glenoid will be helpful for a more accurate insertion in glenoid component. It is thought that more accurate insertion is possible if we can set other anatomical measurements using computed tomography imaging of the glenoid which can develop into the study of other anatomical measurements.

조립오차의 광학식 측정에 의한 VCR HEAD 조정 SYSTEM (Adjustment System by Optical Measurements of Assembly Tolerancies of VCR HEAD)

  • 윤병한;윤종순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.849-851
    • /
    • 1995
  • Magnetic heads on vcr drum are adjusted for protrusion, rotational angle, setting angle between two symmetrically positioned heads and height difference. Developed adjustment system covered assembly spec., namely ${\pm}2{\mu}m$ and ${\pm}30{\mu}m$ in rotational angle by using the image processing to determine head positions and S/W algorithm to compensate mechanical errors.

  • PDF