• Title/Summary/Keyword: Angle fracture

Search Result 631, Processing Time 0.025 seconds

Determination of CTOD & CTOA Curve for Structural Steel Hot-Rolled Thin Plates (일반 구조용강 열간압연 박판에 대한 CTOD와 CTOA 곡선 결정)

  • 이계승;이억섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.729-732
    • /
    • 2003
  • The K-R design curve is an engineering method of linear-elastic fracture analysis under plane-stress loading conditions. By the way, linear-elastic fracture mechanics (LEFM) is valid only as long as nonlinear material deformation is confined to a small region surrounding the crack tip. Like general steels, it is virtually impossible to characterize the fracture behavior with LEFM, in many materials. Critical values of J contour integral or crack tip opening displacement (CTOD) give nearly size independent measures of fracture toughness, even for relatively large amounts of crack tip plasticity. Furthermore, the crack tip opening displacement is the only parameter that can be directly measured in the fracture test. On the other. the crack tip opening angle (CTOA) test is similar to CTOD experimentally. Moreover, the test is easier to measure the fracture toughness than other method. The shape of the CTOA curve depends on material fracture behavior and, on the opening configuration of the cracked structure. CTOA parameter describes crack tip conditions in elastic-plastic materials, and it can be used as a fracture criterion effectively. In this paper, CTOA test is performed for steel JS-SS400 hot-rolled thin plates under plane-stress loading conditions. Special experimental apparatuses are used to prevent specimens from buckling and to measure crack tip opening angle for thin compact tension (CT) specimens.

  • PDF

A STUDY OF CORRELATION BETWEEN MANDIBULAR ANGLE FRACTURE AND THE MANDIBULAR THIRD MOLAR (하악 제3대구치와 하악 우각부 골절과의 상관관계에 대한 연구)

  • Park, Sun-Hye;Choi, Jun-Young;Kim, Seong-Il;Yoo, Jun-Yeol;Leem, Dae-Ho;Shin, Hyo-Keun;Ko, Seung-O
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.6
    • /
    • pp.420-425
    • /
    • 2009
  • Purpose: The aim of this study is to analyze the correlation between incidence of mandibular angle fracture and eruption state of mandibular third molar using clinical and radiographic findings. Materials and Methods: The data were obtained from the clinical and radiographic records of 205 patients who visited the Department of Oral and Maxillofacial Surgery, Chonbuk National University Hospital for treatment of the mandibular fracture. Panoramic radiographies were taken for radiographic examination and the mandibular third molars were classified according to age, gender, position and eruption state. Data were analyzed by a chi-square statistics. Results: In this study, the incidence of mandibular angle fracture had a tendency to be greater when a mandibular third molar was present(p>0.05), but there was not a statistically significant difference. Of the 255 cases with a mandibular third molar, 67 had an angle fractures. Of the 155 cases without a mandibular third molar, 138 had not angle fracture. And the incidence of mandibular angle fracture was high at class BII(by Pell & Gregory system)(p<0.05). Conclusion: Although there was not a statistically significant difference, mandibular third molar was more susceptible to mandibular angle fracture. When the reduction of mandibular angle fracture, it was recommended that mandibular third molar should be extracted especially in case of pericoronitis, periodontitis and other infections.

Marginal accuracy and fracture strength of Targis/Vectris Crowns prepared with different preparation designs

  • Song, Ho-Yong;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.6
    • /
    • pp.791-799
    • /
    • 2000
  • Statement of problem. Targis/Vectris restorations provide excellent esthetics. Marginal accuracy is significantly influenced by the preparation design. There were no studies to examine the effect of preparation design on the marginal discrepancy and fracture strength of Targis / Vectris crowns. Purpose. This study evaluated the marginal accuracy before and after cementation, and the fracture strength of FRC/Ceromer(Targis / Vectris) crowns according to different preparation design. Material and method. Three metal dies with different convergence angles($6^{\circ},\;10^{\circ},\;15^{\circ}$) were prepared. Total 30 (10 for each angle) Targis/Vectris crowns were made. The restorations were evaluated for adaptation of the margin before and after cementation, then were compressively loaded to failure. Fracture surfaces of the crowns were examined using a SEM. Results. The mean marginal gap was $49{\yen}m\;for6^{\circ},\;55{\S}>for\;10^{\circ}\;and\;70{\S}>for\;15^{\circ}$ and in clinically acceptable level. The mean marginal gap increased significantly after cementation. The increasing amount during cementation was the largest in the $6^{\circ}$ group. The crowns on 60 convergence angle had a significantly higher fracture strength than the crowns on $15^{\circ}$ angle. Mean fracture strength of total crowns regardless of convergence angle was 1390 N, which was higher than all-ceramic crowns. SEM observation showed two-mode fracture pattern. Conclusion. From the results of this study, all of the FRC/Ceromer crowns had clinically acceptable marginal accuracy and could withstand the bite force. Moreover, less convergent angle than all-ceramic crown might be recommended for preparation procedure.

  • PDF

A Study on the Prepreg Treatment to Improve Interlaminar Fracture Behavior of Graphite/Epoxy Composites (Graphite/Epoxy 적층복합재의 층간파괴 향상을 위한 프리프레그의 전처리 연구)

  • Kim, Min-Ho;Rhee, Kyong-Yop;Paik, Young-Nam;Kim, Hyeon-Ju;Jung, Dong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.10
    • /
    • pp.68-73
    • /
    • 2006
  • In this study, the graphite/epoxy prepregs were surface-treated using oxygen plasma, and optimal treatment time was determined measuring the contact angle on the prepreg surface. Interlaminar fracture behavior of surface-treated graphite/epoxy composites was compared with that of regular (untreated) graphite/epoxy composites. The results showed that the contact angle was a minimum when treated for 30 minutes. The interlaminar fracture toughness of surface-treated specimen was improved about 15% compared with that of regular specimen.

Broden photographing method for Calcaneus Subtentaculum tali observation of Ankle plaster patient (발목부상을 당한 석고환자의 발꿈치뼈·목말받침돌기 관찰을 위한 Broden 촬영법 연구)

  • An, Byeongju
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • There is an Ankle Oblique(Broden' low) as an examination for the patient whose ankle was encased in orthopedic plaster. Some types of Ankle Joint coalition - Calcaneonavicular coalition, Talocalcaneal coalition and Naviculocuneiform coalition. This study is focused on the relation between Ankle Joints and the structural change of soft tissues, also finding the most proper angle to obtain good images of Ankle Joint from the patient who wore a plaster on his ankle, when we x-ray with Harris-Beath View($30^{\circ}{\sim}55^{\circ}$) - for observing Subtalar joint, Calcaneus Fracture, Subtentaculum, Tali Fracture and Talocalcaneal coalition. We intend to get the angle which makes us achieve the good image that shows Calcaneus Fracture, Subtentaculum, and Tali Fracture by changing internal angles of the patient's ankle. We evaluated the images obtained from 51 patients with PACS monitor. The result of the evaluation, subtalar joint was not seperated but opened, and Subtentaculum Tali Fracture was seen overlaid. at the angle 30, we could observe Calcaneus Fracture, Subtentaculum Tali Frature and the front part of behind side of subtalar joint well. And Calcaneo Navicularcoalition, Talocal Canealcoalition, Naviculo Cuneiform coalition condition were clearly seen at that angle. At the angle 35, we could achieve the clear images of subtalar comminuted fracture, talus, the behind joint of heel bone and get the high definition image on the degree of talocalcaneal joint separation. In addition to, We could obtain the good wide image of Sinus Tarsi. At the area of 45, We can distinguish the soft tissues from gyps separation. The outer-talus and density of the bone were definitely seen and Calcaneus is more separated than that of at the angle of 35, but this image is distorted. Calcaneus, Subtentaculum Tali show $1.20{\pm}0.414$ at the angle 25, $2.47{\pm}0.516$ at the angle 30, $2.27{\pm}0.458$ at the angle 45. This difference is statistically meaningful. (p<0.05). Including the degree of distortion, The distortion appears less at the area of $30^{\circ}$ but at the area of 40, there is heavy distortion. So, We could get the best image for making a diagnosis. At the $30{\sim}35^{\circ}$ degree for X-raying ankle. and at the $30{\sim}40^{\circ}$ for Calcaneus Fracture, Subtentaculum Tali Fracture.

The Relationship between Foot Arch Structure and March Fractures - Comparative study between 15(30feet) normal person and the 15(30feet) patients with march fracture - (행군골절 발생과 발아치 구조의 연관성에 대한 연구보고)

  • Bae, Young-Jae;Yoon, Sung-Il
    • Journal of Korean Foot and Ankle Society
    • /
    • v.2 no.2
    • /
    • pp.71-75
    • /
    • 1998
  • The fact that, under similar training activities performed in the same environment, march fractures develop in only a certain percentage of the trainees indicates that intrinsic factors are affecting the prevalence of these fractures. Among these intrinsic factors, the relation between foot arch type and the occurance of march fractures was investigated in this study. From 1997 to 1998, at one infantry medical company of infantry corps in Korea, 15 march fracture patients were detected among infantry soldiers. Quantitative measures of the foot arch (longitudinal) structure of 15(30feet) march fracture patients were established and compared with those of 15(30feet) normal person. The results were as follows. 1. From the lateral X-ray film, three parameters (i.e. calcaneal angle, forefoot angle, height to length ratio)were defined to describe the structure of the longitudinal arch of the foot. 2. The mean value of the calcaneal angle of march fracture group and normal control group showed 16.4 degree, 20.5 degree respectively. The difference between two groups was statistically significant (P>0.006), but those of forefoot angle and height to length ratio were not. 3. In the calcaneal angle twenty-six feet(87%) of march fracture group were lower than 17 degrees but twenty-five feet(83%) of normal control group were more than 17 degrees. That is, march fracture were more prevalent in feet with low calcaneal angle. 4. In the low arch foot, the orthotic device might relieve the energy load carried by the foot, thus reducing the incidence of march fractures, and should be analyzed in further study.

  • PDF

Evaluation of postoperative complications according to treatment of third molars in mandibular angle fracture

  • Lim, Hye-Youn;Jung, Tae-Young;Park, Sang-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.1
    • /
    • pp.37-41
    • /
    • 2017
  • Objectives: The aim of this study was to evaluate the implication of third molars in postoperative complications of mandibular angle fracture with open reduction and internal fixation (ORIF). Materials and Methods: Data were collected on patients who presented with mandibular angle fracture at our Department of Oral and Maxillofacial Surgery between January 2011 and December 2015. Of the 63 total patients who underwent ORIF and perioperative intermaxillary fixation (IMF) with an arch bar, 49 patients were identified as having third molars in the fracture line and were followed up with until plate removal. The complications of postoperative infection, postoperative nerve injury, bone healing, and changes in occlusion and temporomandibular joint were evaluated and analyzed using statistical methods. Results: In total, 49 patients had third molars in the fracture line and underwent ORIF surgery and perioperative IMF with an arch bar. The third molar in the fracture line was retained during ORIF in 39 patients. Several patients complained of nerve injury, temporomandibular disorder (TMD), change of occlusion, and postoperative infection around the retained third molar. The third molars were removed during ORIF surgery in 10 patients. Some of these patients complained of nerve injury, but no other complications, such as TMD, change in occlusion, or postoperative infection, were observed. There was no delayed union or nonunion in either of the groups. No statistically significant difference was found between the non-extraction group and the retained teeth group regarding complications after ORIF. Conclusion: If the third molar is partially impacted or completely nonfunctional, likely to be involved in pathologic conditions later in life, or possible to remove with the plate simultaneously, extraction of the third molar in the fracture line should be considered during ORIF surgery of the mandible angle fracture.

A STUDY ON THE EFFECTS OF CAVITY FORMS ON FRACTURE OF AMALGAM RESTORATION IN DECIDUOUS MOALRS (유구치 와동형성이 아말감 파절에 미치는 영향에 관한 연구)

  • Ha, Dae-Song;Kim, Chong-Kwan;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.11 no.1
    • /
    • pp.159-167
    • /
    • 1984
  • In this experiments, the fracture loads were measured and analysed by using of Instron universal testing machine (Model 1132). With 80 upper and lower deciduous molars that were free of dental caries. Isthmus of teeth were prepared to 1/3 and 1/4 of intercuspal width, and internal line angles with round and sharp shape, and then amalgam restoration were performed. The results of this study were as follows; 1. Resistance to fracture loads were greater with isthmus of 1/3 intercuspal width than of 1/4 intercuspal width, especially, statistically significant difference on upper and lower second deciduous molars. 2. Resistance to fracture loads were greater with rounded internal line angle than sharp internal line angle. The above results were as follows, the fracture loads had greater resistance on isthmus of 1/3 intercuspal width, and rounded internal line angle, but normal physiological occlusal forces could permit isthmus of 1/4 intercuspal width and rounded internal line angle.

  • PDF

Predisposing Factors and Treatment for the Fifth Proximal Metatarsal Fracture (제5 중족골 기저부 골절의 유발인자 및 치료)

  • Shin, Hun-Kyu;Choi, Jae-Yeol;Lee, Ji-Won
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.67-71
    • /
    • 2007
  • Purpose: To evaluate clinical results of the 5th proximal metatarsal intraarticular fracture (Zone I) with displacement treated operatively and to evaluate predisposing factors of the 5th proximal metatarsal fracture (Zone I). Materials and Methods: 11 patients treated for the 5th proximal metatarsal fracture (Zone I) operatively and 10 patients treated conservatively between Jan 2003 and Dec 2005, were followed for more than one year. Functions were graded by AOFAS foot scoring system and union time and postoperative complications were also evaluated. Calcaneal pitch angle was also evaluated. Results: Clinically there were no much difference in results. Clinical points were 94.5 in the operative group and 92.3 in the conservative group. At the last follow-up, the radiographic results showed union in all cases. During the follow-up period, there were no significant complications. But in the conservative group, displaced fracture with calcaneal pitch angle over 30 degree tends to show delayed union and time to loss of pain tends to be prolonged. Conclusion: Calcaneal pitch angle is thought to predisposing factor for 5th metatarsal base fracture. Operative treatment is viable option for the 5th proximal metatarsal intraarticular fracture with displacement and with calcaneal pitch angle over 30 degree. In cases of cavovarus foot deformity, we think operative treatment should be considered with deliberation and long term follow-up study for peroneal tendinopathy should be needed.

  • PDF

Optimization of Kiln Process Parameters of Low-Temperature Sintering Lightweight Aggregate by Response Surface Analysis (반응표면분석법에 따른 저온소성 경량골재의 킬른공정변수 최적화)

  • Lee, Han-Baek;Seo, Chee-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.5
    • /
    • pp.365-372
    • /
    • 2010
  • This paper was to evaluate the influence of kiln process parameter(kiln angle, kiln rotating speed) of lightweight aggregate using waste glass and bottom ash with industrial by-products on thermal conductivity, density, water absorption, fracture load and porosity by response surface analysis. In the results of surface plot and contour plot, it has verified that kiln residence time of lightweight aggregate increase as kiln angle and rotating speed decreases. For this reason, pore size and quantity tend to increase by active reaction of forming agent. It seems to be that increase in pore size and quantity have caused decreasing density, fracture load and thermal conductivity, and increasing water absorption. In conclusion, optimization of kiln process parameter on thermal conductivity, density, water absorption, fracture load and porosity by response surface analysis are kiln angle 2.4646%, kiln rotating speed 40.7089 rpm.