• Title/Summary/Keyword: Angle fracture

Search Result 636, Processing Time 0.029 seconds

Characterizing Fracture System Change at Boreholes in a Coastal Area in Korea for Monitoring Earthquake (지진감시를 위한 국내 해안지역 시추공 내 단열계 변화 특성)

  • Cheong, Jae-Yeol;Hamm, Se-Yeong;Ok, Soon-Il;Cho, Hyunjin;Kim, Soo-Gin;Yun, Sul-Min
    • The Journal of Engineering Geology
    • /
    • v.29 no.1
    • /
    • pp.1-12
    • /
    • 2019
  • Earthquake can change underground stress condition around the hypocenter and affect the fracture systems of the rocks. In Korea, the M5.8 Gyeongju earthquake on September 12, 2016 and M5.4 Pohang earthquake on November 15, 2017 occurred inside the Yangsan fault zone and possibly affected the fracture systems in the Yangsan fault zone and nearby rock masses. In this study, the characteristics of the fracture system (fracture orientation, number of the fractures, fracture spacing and aperture, dip angle, fracture density along depth, and relative rock strength) of the rocks in the low/intermediate level radioactive waste repository site located in the coastal area of the East Sea are analyzed by the impact of the Gyeongju and Pohang earthquakes using acoustic televiewer data taken from the boreholes at the radioactive waste repository site in 2005 and 2018. As a result of acoustic televiewer logging analysis, the fracture numbers, fracture aperture, and fracture density along depth overall increased in 2018 comparing to those in 2005. This increase tendency may be due to changes in the fracture system due to the impact of the earthquakes, or due to weathering of the wall of the boreholes for a long period longer than 10 years after the installation of the boreholes in 2005. In the borehole KB-14, on the whole, the orientation of the fractures and the average fracture spacing are slightly different between 2005 and 2018, while dip angle and relative rock strength in 2005 and 2018 are similar each other.

Penetration Characteristic of CFRP laminate shell by the curvature -A focus of fracture mode by the penetration- (곡률을 고려한 CFRP 복합재 적층쉘의 관통특성 -관통에 의한 파괴모드를 중심으로-)

  • 조영재;김영남;심재기;양인영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1434-1439
    • /
    • 2004
  • CFRP composite materials have wide application in structure materials of airplane, ships, and aero space vehicles because of their high strength and stiffness. This paper is to study the effects of curvature and orientation angle on the penetration characteristics of CFRP laminate shell. They are staked with 8 Ply specimens [0$_2$/90$_2$]$_{s}$, [0/90$_2$/0]$_{s}$ and the stacked of outer plates degree with 12 Ply specimens [0$_3$/90$_3$]$_{s}$, [0$_2$/90$_2$/0]$_{s}$ and [90$_3$/0$_3$], [90$_2$/0$_2$/90]S. They are manufactured to varied curvature radius (R=100,150,200mm and $\infty$). They are cured by heating to the appropriate harding temperature(13$0^{\circ}C$) by mean of a heater at the vaccum bag of the autoclave. Test specimens were prepared with dimensions 100mm$\times$140mm. When the specimen is subjected to transverse impact by a steel ball, the velocity of the steel ball was measured both before and after impact by determining the time for it to pass two ballistic-screen sensor located a known distance apart. In general, kinetic energy after impact-kinetic energy before impact rised in all specimens. This study observed a fracture mode inside the specimen after a penetration test using a digital camera and it examined a fracture mode and a penetration mode to stack of outer orientation angle and curvature.rvature.

  • PDF

Relationship between mandibular condyle and angle fractures and the presence of mandibular third molars

  • Mah, Deuk-Hyun;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;You, Jae-Seek
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.1
    • /
    • pp.3-10
    • /
    • 2015
  • Objectives: We retrospectively evaluated the impact of mandibular third molars on the occurrence of angle and condyle fractures. Materials and Methods: This was a retrospective investigation using patient records and radiographs. The sample set consisted of 440 patients with mandibular fractures. Eruption space, depth and angulation of the third molar were measured. Results: Of the 144 angle fracture patients, 130 patients had third molars and 14 patients did not. The ratio of angle fractures when a third molar was present (1.26 : 1) was greater than when no third molar was present (0.19 : 1; odds ratio, 6.58; P<0.001). Of the 141 condyle fractures patients, the third molar was present in 84 patients and absent in 57 patients. The ratio of condyle fractures when a third molar was present (0.56 : 1) was lower than when no third molar was present (1.90 : 1; odds ratio, 0.30; P<0.001). Conclusion: The increased ratio of angle fractures with third molars and the ratio of condyle fractures without a third molar were statistically significant. The occurrence of angle and condyle fractures was more affected by the continuity of the cortical bone at the angle than by the depth of a third molar. These results demonstrate that a third molar can be a determining factor in angle and condyle fractures.

Diagnostic Radiology and Conservative Management of L1 Lumbar Spine with Compression Fracture (L1 요추 압박골절에 대한 진단방사선학 및 보존적 치료)

  • 김재웅
    • The Korean Journal of Food And Nutrition
    • /
    • v.11 no.2
    • /
    • pp.165-170
    • /
    • 1998
  • Diagnostic radiology and conservative management for S75 patient with L1 lumbar fracture by traffic accidents were discussed with references, and then the obtained results were as follows ; 1. Wedging compression fractures with 10% deformity was confirmed at anterior vertebral body of L1 lumbar spine through lateral plain X-ray film. 2. Irregular bony fractures were observed at anterior vertebral body of L1 lumbar spine by CT scans, anatomically T12-L1 sites showed highly frequency of injuries, Denis's fracture type was classified as multiple compression fracture at anterior column without abnormal middle and posterior column, also no Cobb's angle, and then Frankel's neurological classification was E grade. 3. Orthopaedic treatments were performed with conservative methods. With rest on the bed, anti-in-flammatory medication, electrolyte and nutritional solution, the pain diminished. 4. After 3 weeks, rehabilitation was worked with putting on polyethylene back corset, although pains remained slightly until after 8 weeks, thereafter the spine showed gradually stability.

  • PDF

A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS WITH CAVITY DESIGN ON FRACTURE OF COMPOSITE RESIN INLAY RESTORED TOOTH (복합레진 인레이 수복시 와동형태에 따른 치아파절에 관한 유한요소법적 연구)

  • Kim, Chull-Soon;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.231-254
    • /
    • 1994
  • Fracture of cusp, on posterior teeth, especially those carious or restored, is major cause of tooth loss. Inappropriate treatments, such as unnecessarily wide cavity preparations, increase the potential of further trauma and possible fracture of the remaining tooth structures. Fracture potential may be directly related to the stresses exerted upon the tooth during masticatory function. The purpose of this study is to evaluate the fracture resistance of tooth, restored with composite resin inlay. In this study, MOD inlay cavity prepared on maxillary first premolar and restored with composite resin inlay. Three dimensional finite element models with eight nodes isoparametric solid element, developed by serial grinding-photographing technique. These models have various occlusal isthmus and depth of cavity, 1/2, 1/3 and 1/4 of isthmus width and 0.7, 0.85 and 1.0 of depth of cavity. The magnitude of load was 474 N and 172 N as presented to maximal biting force and normal chewing force. These loads applied onto ridges of buccal and lingual cusp. These models analyzed with three dimensional finite element method. The results of this study were as follows : 1. There is no difference of displacement between width of occlusal isthmus and depth of cavity. 2. The stress concentrated at bucco-mesial comer, bucco-disal comer, pulpal line angle and the interface area between internal slopes of cusp and resin inlay. 3. The vector of stress direct to buccal and lingual side from center of cavity, to tooth surface going on to enamel. The magnitude of vector increase from occlusal surface to cervix. 4. The crack of tooth start interface area, between internal slop of buccal cusp and resin inlay. It progresses through buccopulpal line angle to cervix at buccomesial and buccodistal comer. 5. The influence with depth of cavity to fracture of tooth was more than width of isthmus. 6. It would be favorable to make the isthmus width narrower than a third of the intercuspal distance and depth of cavity is below 1 : 0.7.

  • PDF

An Experimental Study on the Evaluaiton of Elastic-Plastic Fracture Toughness under Mixed Mode I-II-III Loading Using the Optical PSD (PSD를 이용한 혼합모드 하중하에서 탄소성 파괴인성평가에 관한 실험적인 연구)

  • Kim, Hei-Song;Lee, Choon-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1263-1274
    • /
    • 1996
  • In this paper, as elastic-plastic fracture toughness test under mixed mode loading was proposed using a single edge-cracked specimen subjected to bending moment(M), shearing force(F), and twisting moment(T). The J-integral of a crack in the specimen is expressed in the form J=$J_I$+ $J_II$$J_III$, where $J_I$, $J_II$ and $J_III$ are the components of mode I, mode II and mode III deformation, respectively. $J_I$, $J_II$ and $J_III$ can be estimated from M-$\theta$ ($\theta$;crack opening angle), F-U(U; crack shear displacement) and T-$\alpha$ ($\alpha$;crack twisting angle). In order to obtain the the M<-TEX>$\theta$, F-U and T-$\alpha$ diagram inreal time, a new deformaiton gage for mixed mode loading was proposed using the optical position sensing device(PSD). The elastic-plastic fracture toughness test was carried out with an aluminum alloy. The loading apparatus was designed and manufactured for this experiment. For the loading condition of the crack initatio in the mixed mode, the MMT -3(mode I+ mode II+ mode III) has the lowest values out of the all specimens. This implies that MMT-3 is possible of the crackinitation at lower load, if the specimen acts on together with the torque under the same loading condition. An elastic-plastic fracture toughness test using the PSD brings a successful experimentation in measuring the crack deformation(mode I+ mode II+ mode III).

Bending 30-gauge needles using a needle guide: fatigue life evaluation

  • Jared Joseph Tuttle;Andrew Doran Davidson;Gregory Kent Tuttle
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.23 no.5
    • /
    • pp.281-285
    • /
    • 2023
  • Background: Dentists bend needles prior to certain injections; however, there are concerns regarding needle fracture, lumen occlusion, and sharps handling. A previous study found that a 30-gauge needle fractures after four to nine 90° bends. This fatigue life study evaluated how many 90° bends a 30-gauge dental needle will sustain before fracture when bent using a needle guide. Methods: Two operators at Element Materials Technology, an independent testing, inspection, and certification company tested 48 30-gauge needles. After applying the needle guide, the operators bent the needle to a 90° angle and expressed the anesthetic from the tip. The needle was then bent back to a 0° angle, and the functionality was tested again. This process was repeated until the anesthetic failed to pass through the end of the needle due to fracture or obstruction. Each operator tested 24 needles (12 needles from each lot), and the number of sustained bends before the needle fracture was recorded. Results: The average number of sustained bends before needle failure was 40.33 (95% confidence interval = 37.41-43.26), with a minimum of 20, median of 40, and a maximum of 54. In each trial, the lumen remained patent until the needle fractured. The difference between the operators was statistically significant (P < 0.001). No significant differences in performance between needle lots were observed (P = 0.504). Conclusion: Our results suggest that using a needle guide increases the number of sustained bends before needle fracture (P < 0.000001) than those reported in previous studies. Future studies should further evaluate the use of needle guides with other needle types across a variety of operators. Furthermore, additional opportunities lie in exploring workplace safety considerations and clinical applications of anesthetic delivery using a bent needle.

Generalized fracture toughness for specimens with re-entrant corners: Experiments vs. theoretical predictions

  • Carpinteri, Alberto;Cornetti, Pietro;Pugno, Nicola;Sapora, Alberto;Taylor, David
    • Structural Engineering and Mechanics
    • /
    • v.32 no.5
    • /
    • pp.609-620
    • /
    • 2009
  • In this paper the results of a series of experimental tests upon three-point bending specimens made of polystyrene and containing re-entrant corners are firstly described. Tests involved different notch angles, different notch depths and finally different sizes of the samples. All the specimens broke at the defect, as expected because of the material brittleness and, hence, the generalized stress intensity factor was expected to be the governing failure parameter. Recorded failure loads are then compared with the predictions provided by a fracture criterion recently introduced in the framework of Finite Fracture Mechanics: fracture is assumed to propagate by finite steps, whose length is determined by the contemporaneous fulfilment of energy balance and stress requirements. This fracture criterion allows us to achieve the expression of the generalized fracture toughness as a function of the tensile strength, the fracture toughness and the notch opening angle. Comparison between theoretical predictions and experimental data turns out to be more than satisfactory.

The Influence of Microstructures on the Change of Monotonic Tensile Fracture Mode in Al-Li-Cu-Zr Alloy with Ageing (Al-Li-Cu-Zr합금의 시효에 따른 인장파괴모드변화에 미치는 미세조직의 영향)

  • Chung, D.S.;Lee, S.J.;Cho, H.K.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.9 no.3
    • /
    • pp.212-218
    • /
    • 1996
  • To clarify the influence of precipitation microstructure and inclusion on the monotonic tensile fracture behaviors in 2090 alloy aged at $180^{\circ}C$, the detailed measurement of hardness, tensile strength, elongation and the observation of scanning electron micrography, transmision electron micrography have been carried out. The transgranular shear ductile fracture has been observed in specimen quenched after solution treatment at $500^{\circ}C$ for 45min. While the under-aged specimen was fractured in both transgranular shear ductile and intergranular fracture mode, the fracture mode of peak-aged and over-aged alloy was predominantly intergranular fracture. The fracture behavior of each ageing condition was influenced by the change of precipitation microstructural features. In the case of peak-aged and over-aged alloys, the coarse and heterogeneous slip band caused by both shearable nature of the ${\delta}^{\prime}(Al_3Li)$ precipitates and PFZ along the high angle grain boundary aid the localization of deformation, resulting in low energy intergranular fracture. It was also estimated that the fractured T-type intermetallic phases (inclusion) and the equilibrium ${\delta}$(AlLi) phases which were formed at grain boundaries palyed an important role in promoting intergranular fracture mode.

  • PDF