• Title/Summary/Keyword: Angioplasty, balloon, coronary

Search Result 26, Processing Time 0.024 seconds

Treatment of Coronary Artery Perforation and Tamponade Complicating Balloon Angioplasty by PTFE-Covered Stent. A Case Report

  • Park, Jong-Seon;Hong, Gu-Ru;Bae, Jun-Ho;Cho, Ihn-Ho;Shim, Bong-Sup;Kim, Young-Jo;Shin, Dong-Gu
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.90-95
    • /
    • 2005
  • A coronary artery perforation is a rare but often fatal complication of angioplasty. We experienced a coronary artery perforation and cardiac tamponade during balloon angioplasty. A polytetrafluorethylene (PTFE)-covered stent was used to successfully close the perforation.

  • PDF

Surgical Angioplasty of the Left Main Coronary Artery Stenosis Following Double Valve Replacement -One Cases Report- (중복판막치환술후 발생한 좌주관상동맥협착의 외과적 치료 -1례 보고-)

  • 이광숙
    • Journal of Chest Surgery
    • /
    • v.28 no.4
    • /
    • pp.409-411
    • /
    • 1995
  • One patient developing left main coronary stenosis following double valve replacement is reviewed. Angina pectoris developed 5 months postoperatively. Coronary perfusion with a balloon tip perfusion catheter was performed during previous operation and was considered technically satisfactory. Coronary angiography confirmed stenosis of the left main coronary artery. There was no further coronary arterial disease. An anterior approach between the aorta and pulmonary artery to expose the left main coronary artery was used and patch angioplasty was done. Repeat coronary angiography showed a widely patent left main coronary artery with excellent runoff. A careful search for coronary arterial injury should be made in all symptomatic patients following aortic valve replacement.

  • PDF

Dosimetry and Medical Internal Radiation Dose of Re-188-DTPA for Endovascular Balloon Brachytherapy Against Restenosis after Coronary Angioplasty (혈관성형술 후 재협착 방지 치료에 사용하기 위한 원통형 풍선 Re-188-DTPA의 선량 분포와 내부피폭 선량)

  • Lee, Jin;Lee, Dong-Soo;Shin, Seung-Ae;Jeong, Jae-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.163-171
    • /
    • 1999
  • Purpose: Liquid beta emitter filled in angioplasty balloon could be used to perform endovascular balloon brachytherapy to prevent coronary artery restenosis. We investigated the dosimetry for Re-188-DTPA liquid-filled balloon and medical internal radiation dosimetry in case of balloon leakage. Materials and Methods: We estimated radiation dose from an angioplasty balloon (20 mm length, 3 mm diameter cylinder) to the adjacent vessel wall using Monte Carlo EGS4 code. We obtained time-activity curves of kidneys in normal dog and calculated $T_{max},\;T_{1/2}$. Using MIRDOSE3 program, we estimated absorbed doses to the major organs (kidneys, bladder) and the whole body when we assumed that balloon leaked all the isotope contained. Results: The radiation dose was 17.5 Gy at the balloon surface when we applied 3,700 MBq/ml of Re-188 for 100 seconds, Fifty percent of the energy deposited within 1 mm from the balloon surface. The estimated internal dose to the whole body was 0.005 mGy/MBq and 18.5 mGy for the spillage of 3,700 MBq of Re-188. Conclusion: We suggest that Re-188-DTPA can be used for endovascular balloon brachytherapy to inhibit coronary artery restenosis after angioplasty with tolerable whole body radiation dose in case of balloon rupture.

  • PDF

Changes of Blood Flow Characteristics due to Catheter Obstruction during the Coronary Angioplasty

  • Suh, Sang-Ho;Roh, Hyung-Woon;Kwon, Hyuck-Moon;Lee, Byoung-Kwon
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.2 no.1
    • /
    • pp.25-30
    • /
    • 2004
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Uses of catheters during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. Catheters in blood vessels cause pressure gradient rise and blood flow drop during the measurements. In this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter obstructions during the coronary angioplasty. The computer simulation models are generated by the data, which are measured by coronary angiogram, and the blood is treated as non-Newtonian fluid. The velocity, pressure, and wall shear stress variations are observed for the estimate of damages of blood vessel. This study is also extended to investigate the effects of stenotic vessel size, and shape and catheter size and location.

  • PDF

Blood Flow Characteristics due to Catheter Insertion in the Eccentric Stenosed Coronary Artery (편심협착부가 있는 관상동맥내 카테터삽입에 따른 혈액유동특성)

  • Roh Hyung-Woon;Suh Sang-Ho;Kwon Hyuk-Moon;Lee Byung-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.707-708
    • /
    • 2002
  • Catheters are used to measure translesional pressure gradients in the stenosed coronary arteries. Catheter insertions during coronary angioplasty cause flow obstructions. A narrowed flow cross section with catheter present effectively introduced a tighter stenosis than the enlarged residual stenoses after balloon angiplasty. In general, the form of stenoses are no uniform. Sometimes, these are occurred the irregularly eccentricity If the analyses are conducted for uniform stenosed artery, the results will be underestimated. Thus, in this study, three dimensional computer simulations are conducted to investigate the flow blockage effects due to the catheter insertion during the coronary angioplasty. The results for the eccentric stenosed artery are compared with those of the concentric stenosed artery.

  • PDF

Clinical Experience with IABP in Cardiac Surgery (개심술시 Intra-aortic balloon pump (IABP)의 임상적 적용)

  • 옥창석;지현근
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.34-39
    • /
    • 1997
  • Between May, 1994 and December, 1995, 122 adult cardiac surgical procedures requiring cardiopulmonary bypa s were performed at Kang Dong Sacred Heart Hospital, including 18 cases(14.8%) that were associated with preoperative(n:9), intraoperative(n=7), postoperative(n:2) use of an IABP (intra-aortic balloon pump). The reasons for IABP were low cardiac output and PTCA(percutaneous transluminal coronary angioplasty) failure in preoperative period, CPB(cardiopulmonary bypass) weaning difficulty in intraoperative period, and intractable arrhythmia in postoperative period. The mean age of the IABP patients was 61.8 $\pm$ 6.9 years(range, 39 to 75years). The overall hospital mortalities in patients with preoperative and intraoperative IABP insertion were 3 and 42.9% respectively. Two patients with postoperative IABP insertion are alive. The rate of IABP weaning is 66.7% for preoperative group, 85.7% for intraoperative group and 100% for postoperative group . In conclusion, if there were no irreversible myocardial damages, IABP could be used safely and emergently at any perioperative period for hemo ynamic stability, CPB weaning, and to overcome low cardiac output syndrome.

  • PDF

Difference in Healthcare Utilization for Percutaneous Transluminal Coronary Angioplasty Inpatients by Insurance Types: Propensity Score Matching Analysis (의료보장유형에 따른 Percutaneous Transluminal Coronary Angioplasty 입원 환자의 의료이용 차이 분석: Propensity Score Matching을 이용하여)

  • Seo, Eun-Won;Lee, Kwang-Soo
    • Health Policy and Management
    • /
    • v.25 no.1
    • /
    • pp.3-10
    • /
    • 2015
  • Background: Previous studies showed differences in healthcare utilization among insurance types. This study aimed to analyze the difference in healthcare utilization for percutaneous transluminal coronary angioplasty inpatients by insurance types after controlling factors affecting healthcare utilization using propensity score matching (PSM). Methods: The 2011 national inpatient sample based on health insurance claims data was used for analysis. PSM was used to control factors influencing healthcare utilization except insurance types. Length of stay and total charges were used as healthcare utilization variables. Patients were divided into National Health Insurance (NHI) and Medical Aid (MA) patients. Factors representing inpatients (gender, age, admission sources, and Elixhauser comorbidity index) and hospitals (number of doctors, number of beds, and location of hospitals) were used as covariates in PSM. Results: Tertiary hospitals didn't show significant difference in length of stay and total charges after PSM between two insurance types. However, MA patients showed significantly longer length of stay than that of NHI patients after PSM in general hospitals. Multivariate regression analysis provided that admission sources, Elixhauser comorbidity index, insurance types, number of doctors, and location of hospitals (province) had significant influences on the length of stay in general hospitals. Conclusion: Study results provided evidences that healthcare utilization was differed by insurance types in general hospitals. Health policy makers will need to prepare interventions to influence the healthcare utilization differences between insurance types.

Restenosis and Remodeling (관동맥성형술 후의 혈관 재협착 및 재형성)

  • Chae, Jei-Keon
    • 대한핵의학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.205-208
    • /
    • 1999
  • Percutaneous Transluminal Coronary Angioplasty (PTCA) remains limited by restenosis that occurs in 30 to 50% of patients with coronary artery disease. During the last decade, numerous agents have been used to prevent restenosis. Despite positive results in animal models, no pharmacological therapy has been found to significantly decrease the risk of restenosis in humans. These discrepancies between animal models and clinical situation were probably related to an incomplete understanding of the mechanism of restenosis. Neointimal thickening occurs in response to experimental arterial injury with a balloon catheter. Neointimal formation involves different steps: smooth muscle cell activation, proliferation and migration, and the production of extracellular matrix. The factors that control neointimal hyperplasia include growth factors, humoral factors and mechanical factors. Arterial remodeling also plays a major role in the restenosis process. Studies performed in animal and human subjects have established the potentials for "constrictive remodeling" to reduce the post-angioplasty vessel area, thereby indirectly narrowing the vessel lumen and thus contributing to restenosis. The reduction of restenosis rate in patients with intracoronary stent implantation has been attributed to the preventive effect of stent itself for this negative remodeling. In addition to these mochanisms for restenosis, intraluminal or intra-plaque thrombus formation, reendothelialization and apoptosis theories have been introduced and confirmed at least in part.

  • PDF

Spontaneous resolution of new coronary artery aneurysm following guideline-directed medical therapy after drug-eluting stent implantation

  • Jae-Geun Lee;Ki Yung Boo
    • Journal of Medicine and Life Science
    • /
    • v.20 no.3
    • /
    • pp.131-134
    • /
    • 2023
  • Here, we present a case of a 56-year-old man with acute myocardial infarction. The patient underwent percutaneous coronary intervention (PCI) at the left main bifurcation and mid-left anterior descending artery using drugeluting stents. Four months after the PCI, the patient was readmitted for cardiac arrest. Coronary angiography (CAG) revealed stent thrombosis in the left main-to-proximal left anterior descending artery and in-stent restenosis in the left main-to-proximal left circumflex artery. We performed balloon angioplasty at the left main to mid-left anterior descending artery and left main to proximal left circumflex artery stents; subsequently, blood flow was fully restored. However, contrast agent extravasation was observed outside the mid-portion of the left main artery to the proximal left anterior descending artery stent, indicating the presence of a coronary artery aneurysm (CAA) outside the stent. After guideline-directed medical therapy with dual antiplatelet agents and high-intensity statins, follow-up CAG revealed near-resolution of the CAA, absence of stenotic lesions, and good blood flow.

A Case of Renovascular Hypertension Controlled by Percutaneous Transluminal Renal Angioplasty with Balloon Dilatation (경피적 신동맥 혈관 성형술로 치료한 신혈관 고혈압증 1례)

  • Park, Sung-Woo;Jeong, Su-Ho;Jeong, Young-Sun;Jun, Yong-Hoon;Hong, Young-Jin;Lee, Ji-Eun
    • Childhood Kidney Diseases
    • /
    • v.12 no.1
    • /
    • pp.105-110
    • /
    • 2008
  • Renovascular hypertension results from a lesion that impairs blood flow to a part of or all, of one or both kidneys. Renal artery stenosis is the major cause of renovascular hypertension and the most common cause of treatable secondary hypertension. Recently, percutaneous transluminal renal angioplasty(PTRA) with or without stent placement, has become the preferred choice for correcting symptomatic renal artery stenosis since it is less invasive than surgical reconstruction. PTRA with balloons designed for the dilatation for the dilatation of the coronary artery can be tried in small sized renal artery stenosis. We report a case of renovascular hypertension in a 13-year-old male who had small sized renal artery stenosis. Hypertension was controlled by PTRA with balloon dilatation.