Vascular Morphometric Changes During Tumor Growth and Chemotherapy in a Murine Mammary Tumor Model Using OCT Angiography: a Preliminary Study

  • Kim, Hoonsup;Eom, Tae Joong;Kim, Jae Gwan
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.54-65
    • /
    • 2019
  • To develop a biomarker predicting tumor treatment efficacy is helpful to reduce time, medical expenditure, and efforts in oncology therapy. In clinics, microvessel density using immunohistochemistry has been proposed as an indicator that correlates with both tumor size and metastasis of cancer. In the preclinical study, we hypothesized that vascular morphometrics using optical coherence tomography angiography (OCTA) could be potential indicators to estimate the treatment efficacy of breast cancer. To verify this hypothesis, a 13762-MAT-B-III rat breast tumor was grown in a dorsal skinfold window chamber which was applied to a nude mouse, and the change in vascular morphology was longitudinally monitored during tumor growth and metronomic cyclophosphamide treatment. Based on the daily OCTA maximum intensity projection map, multiple vessel parameters (vessel skeleton density, vessel diameter index, fractal dimension, and lacunarity) were compared with the tumor size in no tumor, treated tumor, and untreated tumor cases. Although each case has only one animal, we found that the vessel skeleton density (VSD), vessel diameter index and fractal dimension (FD) tended to be positively correlated with tumor size while lacunarity showed a partially negative correlation. Moreover, we observed that the changes in the VSD and FD are prior to the morphological change of the tumor. This feasibility study would be helpful in evaluating the tumor vascular response to treatment in preclinical settings.

Data Mining for Detection of Diabetic Retinopathy

  • Moskowitz, Samuel E.
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.372-375
    • /
    • 2003
  • The incidence of blindness resulting from diabetic retinopathy has significantly increased despite the intervention of insulin to control diabetes mellitus. Early signs are microaneurysms, exudates, intraretinal hemorrhages, cotton wool patches, microvascular abnormalities, and venous beading. Advanced stages include neovascularization, fibrous formations, preretinal and vitreous microhemorrhages, and retinal detachment. Microaneurysm count is important because it is an indicator of retinopathy progression. The purpose of this paper is to apply data mining to detect diabetic retinopathy patterns in routine fundus fluorescein angiography. Early symptoms are of principal interest and therefore the emphasis is on detecting microaneurysms rather than vessel tortuosity. The analysis does not involve image-recognition algorithms. Instead, mathematical filtering isolates microaneurysms, microhemorrhages, and exudates as objects of disconnected sets. A neural network is trained on their distribution to return fractal dimension. Hausdorff and box counting dimensions grade progression of the disease. The field is acquired on fluorescein angiography with resolution superior to color ophthalmoscopy, or on patterns produced by physical or mathematical simulations that model viscous fingering of water with additives percolated through porous media. A mathematical filter and neural network perform the screening process thereby eliminating the time consuming operation of determining fractal set dimension in every case.

  • PDF

Evaluation of Factors Affecting Glomerular Filtration Rate by Contrast Media in Patients with Coronary Angiography (심혈관 조영술 시행 환자의 조영제 사용 시 사구체여과율 변화에 영향을 미치는 인자들 평가)

  • Kim, Eun-Young;Lee, Ok-Sang;Lim, Sung-Cil
    • Korean Journal of Clinical Pharmacy
    • /
    • v.22 no.2
    • /
    • pp.103-112
    • /
    • 2012
  • Performance of coronary angiography for exact diagnosis and treatments of cardiovascular disease have been increased recently and it also brings increase of the contrast-induced nephropathy (CIN) referred from increasing use of radiological contrast agents. The variation of estimated glomerular filtration rate (eGFR) is an indicator of CIN, which is known to increase when renal function is decreased. Therefore, this study was to evaluate the affecting factors including concomitant drug on variation of eGFR of patients who underwent coronary angiography according to the conditions of renal function. Medical records of 66 patients were evaluated retrospectively and the patients underwent coronary angiography or angioplasty with nonionic and isotonic contrast media (iodixanol) at Chungnam national university hospital from 1 Jan 2008 to 30 Jul 2010. Patients group was divided into 2 groups; the patients in stages 3-4 chronic kidney disease (CKD) and the patients in stage 2 CKD. Each group was researched about the effect of concomitant drug and clinical characteristics on eGFR variation. The change of eGFR was compared among baseline and 2 or 3 day after coronary angiography. In results, the eGFR variation in group over age 75 was significantly decreased after radiological contrast agents exposure (p $$\leq_-$$ 0.05). The eGFR variation in anemia was significantly decreased after radiological contrast agents exposure in stage 2 CKD (p > 0.05). The eGFR variation in group under $HbA_{1c}$ 6.5% was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). The eGFR variation by taking statins, angiotensin converting enzyme inhibitors, calcium channel blockers and nitroglycerin was increased after radiological contrast agents exposure in stage 2 CKD (p $$\leq_-$$ 0.05). The eGFR variation by using of diuretics was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). The eGFR variation by taking statins, nitroglylcerin was increased after radiological contrast agents exposure in stages 3-4 CKD(p > 0.05). The eGFR variation in group over contrast dosage 150 ml was significantly decreased after radiological contrast agents exposure in stages 3-4 CKD (p $$\leq_-$$ 0.05). Therefore, when undergoing coronary angiography, contrast dosage should be minimized less than 150 ml, and diuretics should be restricted as possible in stages 3-4 CKD. Patients over age 75 require special attention to prevent CIN, and if patients undergo coronary angiography in stages 3-4 CKD, $HbA_{1c}$ is also requried to maintain below 6.5% to prevent CIN.

Advanced Treatment Planning Method for Gamma Knife Radiosurgery of Cerebral Arteriovenous Malformations (뇌동정맥기형의 감마나이프 방사선 수술 -치료 계획 방법의 개선을 중심으로-)

  • Jang Geon-Ho;Lim Young Jin;Hong Seong Eon;Leem Won
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.87-94
    • /
    • 1995
  • Since March 1992, total 200 patients who visited our hospital as functional or organic lesions of central nervous system were treated by gamma knife stereotactic radiosurgery for 27 months. Thirty-nine patients of total cases was diagnosed as cerebral arteriovenous malformation. The rate of magnification on X-ray film was reduced by cutting fixation adaptor from 1.0 to below 1.45 times. In order to treat the deep- and lateral-seated cerebral arteriovenous malformation, we slightly modified the angiographic indicator, the commercial Leksell system, by cutting each inner sides about 5mm, We performed the more distinction of the scales by adapting 0.5mm or 1mm copper filter to angiographic indicator. The center point of indicator(X=100mm, Y=100mm, Z=100mm) is corrected by adjusting scales of X-, Y-, Z-axis to each inner 100 and outer 100 point within 1-2mm by repeated exposure of X-ray on films in trial-and-errors. We have developed the 'GKANGIO' programed as the Fortran-77 in Microvax - 3100, which can save treatment planning time and perform accurate pretreatment planning using the theoretical target metrix center. The theoretical description of the simplified method is presented for the reduction of experimental and numerical errors in treatment planning of radiosurgery.

  • PDF

Incremental Image Noise Reduction in Coronary CT Angiography Using a Deep Learning-Based Technique with Iterative Reconstruction

  • Jung Hee Hong;Eun-Ah Park;Whal Lee;Chulkyun Ahn;Jong-Hyo Kim
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1165-1177
    • /
    • 2020
  • Objective: To assess the feasibility of applying a deep learning-based denoising technique to coronary CT angiography (CCTA) along with iterative reconstruction for additional noise reduction. Materials and Methods: We retrospectively enrolled 82 consecutive patients (male:female = 60:22; mean age, 67.0 ± 10.8 years) who had undergone both CCTA and invasive coronary artery angiography from March 2017 to June 2018. All included patients underwent CCTA with iterative reconstruction (ADMIRE level 3, Siemens Healthineers). We developed a deep learning based denoising technique (ClariCT.AI, ClariPI), which was based on a modified U-net type convolutional neural net model designed to predict the possible occurrence of low-dose noise in the originals. Denoised images were obtained by subtracting the predicted noise from the originals. Image noise, CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were objectively calculated. The edge rise distance (ERD) was measured as an indicator of image sharpness. Two blinded readers subjectively graded the image quality using a 5-point scale. Diagnostic performance of the CCTA was evaluated based on the presence or absence of significant stenosis (≥ 50% lumen reduction). Results: Objective image qualities (original vs. denoised: image noise, 67.22 ± 25.74 vs. 52.64 ± 27.40; SNR [left main], 21.91 ± 6.38 vs. 30.35 ± 10.46; CNR [left main], 23.24 ± 6.52 vs. 31.93 ± 10.72; all p < 0.001) and subjective image quality (2.45 ± 0.62 vs. 3.65 ± 0.60, p < 0.001) improved significantly in the denoised images. The average ERDs of the denoised images were significantly smaller than those of originals (0.98 ± 0.08 vs. 0.09 ± 0.08, p < 0.001). With regard to diagnostic accuracy, no significant differences were observed among paired comparisons. Conclusion: Application of the deep learning technique along with iterative reconstruction can enhance the noise reduction performance with a significant improvement in objective and subjective image qualities of CCTA images.

A Study on the Angle between the Abdominal Aorta and the Superior Mesenteric Artery by 3D Image Reconstruction (3D 영상 재구성을 통한 복부대동맥과 상장간막동맥과의 각도에 관한 연구)

  • Kim, Young-Keun;Choi, Sung-Kwan
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.63-70
    • /
    • 2003
  • SMAS(Superior Mesenteric Artery Syndrome) is a disease caused by a chronic obstruction of the duodenum(transverse portion), which is hardly detectable. However, it is known that when the superior mesenteric artery and abdominal aorta form a narrow angle, that the transverse portion of the duodenum is pressed down between the superior mesenteric artery and the abdominal aorta, and that this can lead to obstruction of the duodenum. Measuring this angle is a complicated job using conventional angiography, and results often turns out to be inaccurate. In addition, no attempt has been made to determine the value of this angle in Koreans. In this study, we conducted abdominal CT angiography using MIP(maximum intensity projection) on patients with no clinical evidence of SMAS in order to determine the angle at which the superior mesenteric artery branches from the abdominal aorta by using PC based software(Rapidia ver. 1.2) for the image reconstruction. Accordingly, we found that the mean angle between the abdominal aorta and the superior mesenteric artery was $50.05{\pm}15.87^{\circ}$ on average, and that the angle in men($53.64{\pm}16.57^{\circ}$) is higher than in women($46.46{\pm}14.98^{\circ}$). We hope that the angles determined by our study will serve as an important indicator for detecting SMAS.

  • PDF

Usefulness of Myocardial Perfusion SPECT after Percutaneous Coronary Intervention (PCI) (경피적 관상동맥 중재술(Percutanerous Coronary Intervention; PCI) 후 심근 관류 SPECT의 유용성)

  • Lee, Jong-Jin;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.114-117
    • /
    • 2005
  • As the indication of percutaneous coronary intervention (PCI) has expanded to the more difficult and complicated cases, frequent restenosis is still expected after PCI. According to AHA/ACC guideline of the present time, routine use of myocardial perfusion single photon emission tomography (SPECT) is not recommended after coronary intervention, but symptom itself or exercise EKG is not enough for the detection of restensis or for the prediction of event-free survival. In high risk and/or symptomatic subjects, direct coronary angiography is required myocardial perfusion SPECT could detect restenosis in 79% of the patients if performed 2 to 9 months after PCI. Reversible perfusion decrease in the myocardial perfusion SPECT is known to be the major prognostic indicator of major adrerse cardiac event in PCI patients and also the prognosis is benign in the patients without reversible perfusion decrease. Though the cumulated specificity is 79% in the literature and optimal timing of myocardial perfusion SPECT is in controversy, SPECT is recommended even in asymptomatic patients at 3 to 9 months after PCI. Considering the evidences recently reported in the literature, myocardial perfusion SPECT is useful for risk stratification and detection of coronary artery restenosis requiring re-intervention in the asymptomatic patients after PCI.

Characteristics of Focused Ultrasound Mediated Blood-Brain Barrier Opening in Magnetic Resonance Images

  • Kyung Won Chang;Seung Woo Hong;Won Seok Chang;Hyun Ho Jung;Jin Woo Chang
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.2
    • /
    • pp.172-182
    • /
    • 2023
  • Objective : The blood-brain barrier (BBB) is an obstacle for molecules to pass through from blood to the brain. Focused ultrasound is a new method which temporarily opens the BBB, which makes pharmaceutical delivery or removal of neurodegenerative proteins possible. This study was demonstrated to review our BBB opening procedure with magnetic resonance guided images and find specific patterns in the BBB opening. Methods : In this study, we reviewed the procedures and results of two clinical studies on BBB opening using focused ultrasound regarding its safety and clinical efficacy. Magnetic resonance images were also reviewed to discover any specific findings. Results : Two clinical trials showed clinical benefits. All clinical trials demonstrated safe BBB opening, with no specific side effects. Magnetic resonance imaging showed temporary T1 contrast enhancement in the sonication area, verifying the BBB opening. Several low-signal intensity spots were observed in the T2 susceptibility-weighted angiography images, which were also reversible and temporary. Although these spots can be considered as microbleeding, evidence suggests these are not ordinary microbleeding but an indicator for adequate BBB opening. Conclusion : Magnetic resonance images proved safe and efficient BBB opening in humans, using focused ultrasound.

Radiation Dose and Estimate of Lifetime Attributable Risk of Cancer from Coronary Angiography and Percutaneous Coronary Intervention (관상동맥조영술과 경피적관상동맥중재술에서 환자 선량과 암 발생 생애귀속위험 평가)

  • Kang, Yeong-Han;Kim, Bu-Sun;Park, Jong-Sam
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.213-221
    • /
    • 2010
  • The Purpose of this study was to determine the effective dose to an average patient from Coronary Angiography (CA) and Percutaneous Coronary Intervention (PCI). And to estimate the lifetime attributable risk (LAR) of cancer associated with radiation exposure from CA and PCI. The dose-area product (DAP) values to the patient were recorded from 60 CA and 58 PCI. A Monte Carlo based program PCXMC was used to calculate the effective dose from DAP values for each patient. Lifetime attributable risks were estimated with models developed in the National Academies' Biological Effects of Ionizing Radiation VII report. The mean DAP values was $53.76\;Gy{\cdot}cm^2$ for CA and $165.82\;Gy{\cdot}cm^2$ for PCI. Mean effective dose were 1.28 mSv in CA, 3.94 mSv in PCI. Results of Calculate organ dose, lung doses was 2.17 mSv in CA and 6.71 mSv in PCI. Female breast doses was 5.45 mSv in CA and 16.82 mSv in PCI. LAR estimates for CA varied from 1 in 1,508 for man to 1 in 1,357 for women. In PCI procedure varied from 1 in 553 for man to 1 in 482 for women. DAP can be used as the dose indicator to calculate the organ dose and effective dose of patient based on Monte Carlo simulation. These dose estimates derived from our simulation models suggest that CA and PCI are associated with a nonnegligible LAR of cancer. This risk varies markedly and is considerably greater for women, PCI than for man, CA.

Study on the Contrast Media Volume according to Scan Time during Brain Angiography Examination (Brain Angiography 검사 시 Scan Time에 따른 Contrast Media Volume에 대한 연구)

  • Lee, Ju Ryeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.29-35
    • /
    • 2021
  • The purpose of this study was to investigate whether there is a difference in image quality before and after reducing the amount of contrast medium in cerebral hemorrhagic patients who periodically follow up CT, and after reducing the amount of contrast medium, the image before and after reduction was examined, and the image quality was assessed by setting ROI at each vessel location using MMWP program. First Rt. CCA, Lt.CCA. Rt.MCA, Lt.MCA and Basilar Artery each got an ROI. Second, the mean and standard deviation values for the ROI were obtained. Third, SNR and CNR were obtained through the average and standard deviation values obtained. T-test statistics show that the SNR and CNR values obtained show that the result values for SNR are Rt.CCA 0.765, Ltd.CCA 0.871, Rt.MCA 0.343 LT.MCA 0.235, Basilar alternative 0.916, result value for CNR Rt.CCA 0.088, Ltd.CCA 0.069, Rt.MCA 0.818, Let's...MCA 0.579 and Basilar Artery 0.878. The results obtained through the obtained SNR and CNR values showed no difference in the quality of the images before and after reducing contrast medium. Therefore, we hope that this study will be an indicator that reduces the burden on contrast agents on patients who do CT examinations periodically.