• Title/Summary/Keyword: Anchor Unit

Search Result 42, Processing Time 0.025 seconds

Monetary Unification in North East Asian Economies and Setting an Anchor Currency by CNY and JPY (한중일 3개국의 화폐통합과 기축통화 설정에 관한 연구)

  • Rhee, Hyun-Jae
    • International Area Studies Review
    • /
    • v.14 no.2
    • /
    • pp.61-78
    • /
    • 2010
  • The paper is basically attempted to reveal a possibility of monetary unification and setting an anchor currency in North East Asian economies such as South Korea, China, and Japan. The Cobb-Douglas utility function is tentatively built by a Walrasian economic framework. Korean Won(KRW) is represented for a numeraire in a structural model, and the estimation of a parameter is performed by 2SLS and GARCH-M models. Empirical evidence is found that not only monetary unification itself in this regime seems not to be practicable, but also setting an anchor currency by Chinese Yuan(CNY) or Japanese Yen(JPY) is also inappropriated due to the fact that the estimated parameter is not converged to a unity. Walrasian equilibria are enhanced by the convergence to a unity in the model. It also has to be mentioned that a number of necessary and sufficient conditions should be fulfilled prior to discuss a monetary unification in North East Asian economies. Instead, Asia currency unit(ACU) is more feasible in reality.

Behavior of Mechanical Anchorage Surface-Embedded in Concrete for Post-tensioning CFRP Strips (외부 프리스트레스트 탄소섬유판 정착장치의 콘크리트에 대한 정착성능)

  • You, Young-Chan;Choi, Ki-Sun;Park, Young-Hwan;Park, Jong-Sup;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.226-229
    • /
    • 2006
  • Strengthening with externally post-tensioned CFRP strips is more effective in increasing load carrying capacity of existing structures as well as reducing crack width and deflection. This study developed concrete embedded anchorages system for externally post-tensioned CFRP strips, and carried out experimental study to verify anchoring performance quantitatively. Through experimental results, anchoring strength of concrete embedded anchorage were quantified into shear strength of anchor bolt, bearing strength of concrete at the front of anchor plate and bond strength between anchor plate and concrete surface. In addition, overall anchoring performances according to combination of each unit force are examined in this study.

  • PDF

Performance Evaluation of the Cast-in-place Anchor Bolt in Non-cracked Concrete used in Power Plant Facilities (비균열 콘크리트에 매립된 발전설비 정착부 선 설치 앵커의 구조성능 평가)

  • Kim, Dong-Ik;Jong, Woo-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.250-258
    • /
    • 2019
  • The seismic performance and stability of operating facilities installed in domestic power plants need to be verified because of the increased incidence of earthquakes resulting in power plant damage due to the overturning failure of electric operating facilities. In this study, a structural performance evaluation of the anchor bolts constructed to setup the operating facilities on concrete slabs was carried out through an on-site inspection of power plants, called Daechung-Dam. M10 J hook and M12 J hook anchor bolts were installed in the field unit. According to the ASTM E 488-96 specifications, anchor bolt pullout and shear tests were carried out and compared with the anchor-bolt design standards. The results from the tension and shear pullout tests showed that the M10 and M12 J hook anchor bolts had higher performance than the required design load. Thus, they were found to be safe enough. Nevertheless, more research in the field of analytical study will be needed in the near future.

Structural Performance of the Cast-in-place Anchor in Cracked Concrete used in Power Plant Facilities (균열 콘크리트에 매립된 발전설비 현장설치용 선 설치 앵커의 구조성능 평가)

  • Kim, Dong-Ik;Jung, Woo-young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.120-128
    • /
    • 2019
  • It is very important to verify the seismic performance and stability of the power plant fixture in the domestic power plant, because earthquakes have increased in frequency around the world which resulted in the frequent occurrence of power plant damage caused by the failure of electric power facilities. In this study, through the on-site inspection of power plant fixation unit installed in domestic power plants, we carried out structural performance evaluation of the fixation unit anchor bolts installed on the concrete slabs. The field survey showed M12 J hook anchor bolts were used. Anchor bolt pullout and shear performance evaluation were performed based on ASTM E 488-96 standard. Moreover, artificial crack with the width of 0.5 mm was applied during the experiment based on ATM355.4 and ETAG 001. The comparison of M12 J hook anchor bolt pullout and shear test result to design value required in domestic and international design standard, show a satisfactory result. M12 J hook anchor pullout and shear performance was found to be about 35% and 7%, respectively, higher than the required design value.

Evaluation of Vibration Characteristics of Operating Rotational Machines Depending of Types of Foundation (기초형식에 따른 회전기기의 가동중 진동특성 분석)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.63-72
    • /
    • 2007
  • The Emergency Diesel Generator (EDG) is a very important equipment for the safety of a Nuclear Power Plant (NPP). In this study, the operating vibration of three kinds of EDG systems was measured. The target EDG systems are Yonggwang 5 unit and Ulchin 2 and 3 units. The Yonggwang 5 and Ulchin 3 unit EDG systems are the same type but the foundation systems are different. One is an anchor bolt type and the other is a spring and viscous-damper type. The purpose of these measurements is for a verification of the vibration isolation effect depending on the foundation system. As a result, It can be said that the spring and viscous damper system of the EDG performed better for the vibration isolation than that of anchor bolt type.

Heat Loss the Case Study of Office Building (사무소 건축물의 열손실 사례연구)

  • Kim, Kyeong-A;Kim, Bongl-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.51-54
    • /
    • 2011
  • In this study, It has the purpose to evaluate the insulation of the curtain wall of a building on the construction from 1990 to 2011 by measuring the inside and outside surface temperature of the curtain wall. The outside frame surface(mullion bar or spandrel bar) temperature of the curtain wall is 6℃~10℃ higher than that of the surface of glasses or insulation panel of curtain wall in winter. Furthermore the outside surface of frame anchor unit is 2℃~3℃ higher than section of other frame, so it was verified lossing lots of heating.

  • PDF

Monitoring of Floating Fish Reef Installed in Koje Coastal Waters

  • Kim, Chang-Gil;Kim, Ho-Sang;Kim, Tae-Ho;Baik, Chul-In
    • Ocean and Polar Research
    • /
    • v.23 no.3
    • /
    • pp.305-310
    • /
    • 2001
  • This paper describes a floating fish reef technology for enhancement of fisheries productivity in the muddy areas. The floating fish reef was composed of main fish cage, anchor rope and concrete anchor blocks. Main fish cage was made up of 12 steel buoys measuring 0.37m in diameter and 1.5m long, polyethylene (PE) netting and circular steel rings. Each steel buoy had buoyancy of 110kgf. The size of main fish cage was 1.96 m in diameter and 3.75m in length. Monitoring on its durability was made for eight months after installation. The steel buoys fixed on main fish cage and nettings were observed to be kept safely. The wet weight of fouling organisms per unit area$(m^2)$ was 26.6kgf after eight months. Reduction in the cross-section of steel buoys and circular steel rings of main fish cage were not found. In addition, any cracks on the concrete anchor blocks were not observed.

  • PDF

Structural and Layout Design Optimization of Ecosystem Control Structures(1) -Characteristics of Mooring Force and Motion Control of the Longline Type Scallop Culturing Facility- (생태계 제어 시설물의 설계 및 배치 최적화(1) -연승식 양식시설의 계류력 특성 및 동요저감에 관한 연구-)

  • RYU Cheong-Ro;KIM Hyeon-Ju
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.1
    • /
    • pp.35-48
    • /
    • 1995
  • To develop the optimal design method for the longline type scallop culturing facilities in the open sea numerical calculations and hydraulic model experiments are carried out for the stability and function optimization. Using the results for the motion and tension of the facilities, stable design concepts and effects of motion control system by vertical anchor and resistance discs art discussed. The results of this study that can be applied to the design are as follows: 1) Total external forces by design wave $(H_{1/3}\;=\;6,7\;m,\;T_{1/3}\;=\;12sec)$ at the coastal waters of Jumunjin for unit facility (one main line) are estimated to 5-20 tons, and required anchor weights are 10-40 tons in the case of 2-point mooring system. Though the present facilities are stable to steady currents, but is unstable to the extreme wave condition of return period of 10 years. 2) The dimensions and depth of array systems must be designed considering the ecological environments as well as the physical characteristics including the mooring and holding forces that are proportional to the length and relative depth of main line to wave length, and the number of buoys and nets. 3) Oscillation of the facility is influenced by water particle motion and the weight of hanging net, and is excited at both edge, especially at the lee side. To reduce the motion of the nets, the vertical anchoring system and the resistence disc method are recommended by the experimental results, 4) The damage of rope near the anchor by abrasion should be prevented using the ring-type connection parts or anchor chains.

  • PDF

Conceptual design of cooling anchor for current lead on HTS field coils

  • Hyeon, C.J.;Kim, J.H.;Quach, H.L.;Chae, S.H.;Yoon, Y.S.;Lee, J.;Han, S.H.;Jeon, H.;Choi, Y.H.;Lee, H.G.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.38-43
    • /
    • 2017
  • The role of current lead in high-temperature superconducting synchronous machine (HTSSM) is to function as a power supply by connecting the power supply unit at room temperature with the HTS field coils at cryogenic temperature. Such physical and electrical connection causes conduction and Joule-heating losses, which are major thermal losses of HTSSM rotors. To ensure definite stability and economic feasibility of HTS field coils, quickly and smoothly cooling down the current lead is a key design technology. Therefore, in this paper, we introduce a novel concept of a cooling anchor to enhance the cooling performance of a metal current lead. The technical concept of this technology is the simultaneously chilling and supporting the current lead. First, the structure of the current lead and cooling anchor were conceptually designed for field coils for a 1.5 MW-class HTSSM. Then, the effect of this installation on the thermal characteristics of HTS coils was investigated by 3D finite element analysis.

Effects of External Pop-up Satellite Archival Tag (PSAT) Tagging Method on Blood Indices and PSAT Attachment Efficiency of Yellowtail Seriola quinqueradiata (Pop-up Satellite Archival Tag (PSAT) 체외 부착방법에 따른 방어(Seriola quinqueradiata)의 혈액성상 및 PSAT 부착효율)

  • Oh, Sung-Yong;Jeong, Yu-Kyung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.1
    • /
    • pp.38-45
    • /
    • 2021
  • This study aimed to determine the effect of the pop-up satellite archival tag (PSAT) tagging method on the blood indices and PSAT attachment efficiency of yellowtail Seriola quinqueradiata (mean body weight 10.2 kg). Based on tagging method, the fishes were divided in four different groups: untagged (control), single anchor (SA), dual anchor (DA), and silicon tube (ST). The blood indices and PSAT attachment efficiency were investigated on days 1, 14, and 28 after tagging PSAT on the muscle below the dorsal fin for each tagging method in triplicates. After 28 days of tagging with PSAT, a significant increase was observed in plasma glucose level in the ST group and in total protein level in the DA and ST groups. The levels of glucose, total protein, and total cholesterol in the SA group after 28 days of tagging were significantly lower than in the control group. The efficiencies of PSAT attachment were 0% in the SA and DA groups on 14 days post-tagging, and 66.7% in the ST group on 28 days post-tagging. The study results indicate that the proper PSAT tagging method is the ST type. The information obtained in this study presents valuable data that provide the required PSAT operational tool for industrial development and ecological monitoring of yellowtail.