• Title/Summary/Keyword: Analytical reagent

Search Result 117, Processing Time 0.024 seconds

Green flow injection spectrophotometric system for lead ion (II) evaluation in vegetables samples using new azo reagent

  • Fatimah Lateef Al-Zubaidi;Khdeeja Jabbar Ali
    • Analytical Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • A new, sensitive, and reliable flow injection methodology was investigated for the determination of lead ion (II) in vegetables' samples using a laboratory-prepared reagent 2-[(6-methoxy-2-benzothiazoly)azo]-4-methoxy phenol (6-MBTAMP). Infrared spectroscopy, UV-visible spectrophotometry, Energy dispersive X-ray spectroscopy (EDX), Elemental Analysis (CHN), nuclear magnetic resonance spectroscopy 1HNMR, and 13CNMR techniques were used to characterize the reagent and lead (II) complex. The method is based on lead ion (II) reacting with the reagent (6-MBTAMP) in a neutral solution to produce a green-red complex with a maximum absorbance at 670 nm. The optimum conditions, such as flow rate, lead ion (II) volume, reagent volume, medium pH, reagent concentration, and reaction coil length were thoroughly examined. The limits of detection (LOD) and quantification (LOQ) were determined to be 0.621 mg·L-1 and 2.069 mg·L-1 , respectively, while Sandell's sensitivity was determined to be 0.345 ㎍·cm-2.

Development of a New Method for Total Isocyanate Determination Using the Reagent 9-Anthracenylmethyl 1-Piperazinecarboxylate(PAC):Part 1 - The reaction condition and stability (9-Anthracenylmethyl 1-Piperazinecarboxylate(PAC)을 이용한 공기중 총이소시아네이트 분석방법 개발:제1부 반응조건 및 안전성)

  • Roh, Young-Man;Streicher, Robert P.
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.167-176
    • /
    • 1999
  • A new analytical procedure for the measurement of monomeric isocyanates and total isocyanate group in workplaces has been investigated. The method described herd involves derivatization of the isocyanate sample upon collection with the reagent 9-anthracenylmethyl 1-piperazinecarboxylate (PAC). Laboratory investigations have demonstrated that excess PAC reagent can be satisfactorily removed from PAC-derivatized monomeric isocyanates-a requirement for the success f the analytical procedure. After removal of excess PAC reagent, the PAC derivatives of butyl isocyanate, phenyl isocyanate, HDI, MDI, and TDI were reacted with sodium thiomethoxide to convert them all to 9-anthracenylmethyl methyl sulfide (AMMS). Total isocyanate group was determined by HPLC analysis and quantification of the single AMMS peak. This circumvents many of the disadvantages associated with current HPLC methods. There were no longer problems associated with quantifying late-eluting peaks and analysis times were very short. A single detector was used for quantification because a standard of the analyte existed and the retention time could be determined. Because all species were converted to a single analyte, the problem of variability of response factors among different species was averted. Finally, there were no complex chromatograms to interpret. Monomers of other individual species were measured by analysis of the sample before the individual species were converted to AMMS. The favorable performance of PAC warrants its further study as a reagent for the determination of total isocyanate group in air.

  • PDF

Direct Detection of Water-dissolved Ammonia Using Paper-based Analytical Devices

  • Yeong Beom Cho;Duc Cuong Nguyen;Si Hiep Hua;Yong Shin Kim
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.67-74
    • /
    • 2023
  • A microfluidic paper-based analytical device (µPAD) is proposed for the selective detection of ammonia in water by using the modified Berthelot reagent and a fluidic channel consisting of hollow paper. The modified Berthelot reagents were uniformly dispersed in cyclohexane and then immobilized in a detection zone of the µPAD. The loading position of the reagents and the type of a sample flow channel were optimized to achieve a sensitive ammonia detection within a short analytical time. The NH3 µPAD exhibits a linear colorimetric response to the concentration of ammonia dissolved in water in the range of 1-100 mg L-1, and its limit-of-detection is 1.75 mg L-1. In addition, the colorimetric response was not influenced by the addition of 100 mg L-1 nitrogen containing compounds (sodium nitrate, sodium nitrite, uric acid, hydroxylamine, butylamine, diethylamine) or inorganic salts (NaCl, Na2HPO4), presenting the enough selectivity in the detection of water-dissolved ammonia against possible interferents.

Evaluation of developing efficiency on latent fingerprint (잠재지문 현출효율 평가에 대한 연구)

  • Kim, Man-Ki;Park, Sung-Woo;Ohgami, Yusuke
    • Analytical Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.166-171
    • /
    • 2009
  • Powder method is simple and very effective method for developing latent finger and palm print in crime scene. This technique has been actively studied to enhance effectiveness. In general, the evaluation for developing powder is mainly performed by the subjective opinion of researcher from comparison of the results obtained with existing and new one to develope finger and palm deposition. The purpose of this work is to present objective method of powder-treated latent fingerprint for evaluating method by developing efficiency. We indicated three evaluating methods of objective developing efficiency, which are measuring the number of minutiae in same sections on print, scattering level of developing reagent and contrast between developing reagent and background materials.

Application of Gossypol Acetic Acid as a Reagent For Iron (Iii) Ions

  • U. K. Abdurakhmanova;M. R. Askarova;H. K. Egamberdiev
    • Journal of the Korean Chemical Society
    • /
    • v.68 no.1
    • /
    • pp.20-24
    • /
    • 2024
  • This article presents the advantages of utilizing gossypol and its derivatives as reagents for iron (III) (Fe (III)) ions. A novel spectrophotometric method has been developed for the determination of Fe (III) using gossypol derivatives in the presence of a universal buffer solution. Optimal conditions have been identified, and the composition and stability constants of the Fe (III) complex with gossypolacetic acid have been determined.

Separation and identification of selenoproteins in selenium-enriched yeast (셀레늄이 강화된 이스트에서 셀레늄 단백질의 분리 및 확인)

  • Kim, Kyong-Mi;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.357-363
    • /
    • 2013
  • Selenium-containing proteins were separated from selenium-enriched yeast (SEY) using Trizol$^{(R)}$ reagent followed by anion exchange (AE) chromatography. This method is simpler and less time consuming than electrophoresis. Five selenium containing proteins were identified by on-line AE HPLC-ICP/MS (high performance liquid chromatography-inductively coupled plasma/mass spectrometry). Each protein was enzymatically hydrolyzed to seleno-amino acids and separated with RP (reverse phase) HPLC for the identification of selenoproteins.

Determination of Memantine HCl by UV Spectrophotometry using MPCN as an UV-labelling Reagent (자외부 유도화제인 MPCN을 이용한 memantine HCl의 정량)

  • Jang, Sun-Sook;Choi, Jung-Kap;Yoo, Gyurng-Soo
    • Analytical Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.405-409
    • /
    • 1993
  • Spectrophotometric assay for memantine HCl was developed by using sodium 1-(4-methoxypheyl) cinnamonitrile-2-sulfonate (MPCN) as an UV labelling reagent. The optimum derivatizing condition was obtained by incubation for 30 min at pH 5.0 in the presence of 20-fold molar excess of the labelling reagent. The absorbance of reaction product was measured at 324.5 nm and detection limit was $0.43{\mu}g/ml$. A linear range was $5.0{\times}10^{-6}{\sim}6.5{\times}10^{-5}M$ of memantine HCl. The linear regression analysis of absorbance at various drug concentration was r=0.9998 (n=6). When applied to memantine HCl ampule and tablet, it gave the mean contents of $100.08{\pm}0.72%$ and $99.75{\pm}0.77%$, respectively.

  • PDF

Development of dry-origin latent footwear impression on non-porous and semi-porous surfaces using a 5-methylthioninhydrin and L-alanine complex

  • Hong, Sungwook;Kim, Yeounjeung;Park, Jihye;Lee, Hoseon
    • Analytical Science and Technology
    • /
    • v.30 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • 5-methylthioninhydrin (5-MTN) is an amino acid sensitive reagent used for the development of latent fingermarks deposited on porous surfaces such as paper and wood. The present study demonstrates that the 5-MTN can be used as a latent footwear impression enhancement reagent, by reacting with trace multivalent metal ions, which are the main components of the latent footwear impression. 5-MTN and L-alanine complex (MTN-ALA) used for the latent footwear impression development was prepared, by mixing $4.5{\times}10^{-3}M$ 5-MTN (in methanol) and $4.5{\times}10^{-3}M$ L-alanine (in methanol) in 1:1 ratio, and keeping undisturbed at room temperature for 24 h. The latent footwear impressions were deposited on white and black non-porous surfaces (glass plate, polyethylene panel, polypropylene panel, acryl panel, polyvinyl chloride (PVC) panel, poly(methyl methacrylate) (PMMA) panel, acrylonitrile-butadiene-styrene (ABS) panel, tile), and a semi-porous surfaces (painted wood). The latent footwear impressions on these surfaces were treated with MTN-ALA complex by spraying. The fluorescence of footwear impressions (occurred due to the reaction between MTN-ALA and metal complexes) was observed under a 505 nm forensic light source and an orange barrier filter. The enhancement of latent footwear impression was achieved from black surfaces without any blurring. However, the fluorescence (enhancement) of footwear impression was not observed on the white PVC, PMMA, and ABS surfaces, because the incident light interfered and reflected on the surface. The sensitivity of MTN-ALA was superior to 2,2'-dipyridil, which is a representative non-fluorescing footwear impression enhancement reagent, and similar to 8-hydroxyquinoline, which is a representative fluorescing footwear impression enhancement reagent.

Indirect Determination of Nitrite by Flame Atomic Absorption Spectrometry Using a Lead(IV) Dioxide Oxidant Microcolumn

  • Noroozifar, Meissam;Khorasani Motlagh, Mozhgan;Taheri, Aboozar;Homayoonfard, Marjan
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.875-880
    • /
    • 2006
  • A new, simple and fast flow injection analysis (FIA) method has been developed for the indirect determination of nitrite. The proposed indirect automatic method is based on the oxidation of nitrite to nitrate using a lead(IV) dioxide oxidant microcolumn where the flow of the sample through the microcolumn reduces the $PbO_2$ solid phase reagent to Pb(II), which is measured by flame atomic absorption spectrometry. The absorbance of Pb(II) are proportional to the concentration of nitrite in the samples. The calibration curve was linear up to 30 mg $L ^{-1}$, with a detection limit of 0.11 mg $L ^{-1}$ for a 400 mL injected sample volume and a sampling rate of about 80 $h ^{-1}$. The results exhibit no interference from the presence of large amounts of ions. The developed procedure was found to be suitable for the determination of nitrite in foodstuffs and wastewaters. A relative standard deviation better than 0.9% was obtained in a repeatability study. The reliability of the method was established by parallel determination against the standard method.

Comparison of Liquid-Liquid Extraction and Solid-Phase Extraction Coupled with GC/MS for Determination of Priority Pollutants in Water (액체 추출법과 고체상 추출법에 의한 수질 중 유해물질 농축법 비교)

  • Yook, Keun-Sung;Hong, Sa-Moon;Kim, Jong-Ho
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.441-453
    • /
    • 1994
  • Two extraction methods, liquid-liquid extraction(LLE) and solid-phase extraction(SPE), coupled with GC/MS were compared as preconcentration procedures for priority pollutants in water. Among the semi-volatile priority pollutants, 11 acid and 44 base/neutral compounds were spiked in reagent water. With LLE, which is a modification of EPA Method 625, the overall mean recovery of the 54 compounds was 91% with a mean relative standard deviation(RSD) of 4.6%. With SPE, the overall mean recovery of the 52 compounds was 53% with a mean RSD of 8.9%. The detection limits of both methods were in the range of $1{\sim}5{\mu}g/l$.

  • PDF