• Title/Summary/Keyword: Analytical measurement range

Search Result 140, Processing Time 0.031 seconds

An Estimation of Springing Responses for Recent Ships

  • Park In-Kyu;Lee Soo-Mok;Jung Jong-Jin;Yoon Myung-Cheol
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.173-178
    • /
    • 2004
  • The estimation of springing responses for recent ships are carried out and application to a ship design are described. To this aim, springing effects on hull girder were re-evaluated including non-linear wave excitations and torsional vibrations of the hull. The Timoshenko beam model was used to calculate stress distribution on the hull girder by the superposition method. The strip method was employed to calculate the hydrodynamic forces and moments on the hull. In order to remove the irregular frequencies, we adopted 'rigid lid' on the hull free surface level and added asymptotic interpolation along the high frequency range. Several applications to the existing ships were carried out. They are Bishop and Price's container ship, S-175 container ship, large container, VLCC and ore carrier. One of them is compared with ship measurement result while another with that of model test. Comparison between analytical solution and numerical one for homogeneous beam type artificial ship shows good agreement. It is found that most springing energy came from high frequency waves for the ships having low natural frequency and North Atlantic route etc. Therefore, the high frequency tail of the wave spectrum should be increased by $\omega^{-3}\;instead\;of\;\omega^{-4}\;or\;\omega^{-5}$ for springing calculation.

  • PDF

Influencing factors on electrical conductivity of compacted kaolin clay

  • Lee, J.K.;Shang, J.Q.
    • Geomechanics and Engineering
    • /
    • v.3 no.2
    • /
    • pp.131-151
    • /
    • 2011
  • The electrical conductivity of a soil-water system is related to its engineering properties. By measuring the soil electrical conductivity, one may obtain quantitative, semi-quantitative, or qualitative information to estimate the in-situ soil behavior for site characterization. This paper presents the results of electrical conductivity measured on compacted kaolin clay samples using a circular two-electrode cell in conjunction with a specially designed compaction apparatus, which has the advantage of reducing errors due to sample handling and increasing measurement accuracy. The experimental results are analyzed to observe the effects of various parameters on soil electrical conductivity, i.e. porosity, unit weight, water content and pore water salinity. The performance of existing analytical models for predicting the electrical conductivity of saturated and unsaturated soils is evaluated by calculating empirical constants in these models. It is found that the Rhoades model gives the best fit for the kaolin clay investigated. Two general relationships between the formation factor and soil porosity are established based on the experimental data reported in the literature and measured from this study for saturated soils, which may provide insight for understanding electrical conduction characteristics of soils over a wide range of porosity.

Quantitative Immunoassay for Polychlorinated Biphenyl Compounds in Electrical Insulating Oils

  • Kim In Soo
    • Proceedings of the Microbiological Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.119-127
    • /
    • 2000
  • The development and performance of a competitive indirect immunoassay for the quantitative measurement of polychlorinated biphenyl compounds in insulating oils is presented. Reagent preparation and the assay characterisation, optimisation and validation steps are described. The dynamic range of the assay for Aroclors 1254 and 1260 in methanol was $50-800 {\mu}g\;ml^{-1}$ with $50\%$ signal inhibition values of 217 and $ 212 {\mu}g\;ml^{-1}$ respectively. Impending legislation in the UK is likely to decree that oils containing $ >50 {\mu}g\;ml^{-1}$ PCB be considered contaminated. Assay sensitivity increased with the degree of PCB chlorination. The assay of structurally related compounds of environmental concern yielded cross-reactivity values of under $0.6\%$. The immunoassay proved reliable for the analysis of transformer oils containing $>70{\mu}g\;ml^{-1}$ PCB, but over-estimated PCB levels in oils containing $<20{\mu}g\;ml^{-1}$ of the analyte with the oils requiring pre-treatment using either solid-phase extraction techniques or washing with KOH-ethanol/sulphuric acid to remove matrix interferents. The analytical performance of the assay was compared against a commercially available semi-quantitative immunoassay kit for PCBs in soil and water.

  • PDF

Free-strain solutions for two-dimensional consolidation with sand blankets under multi-ramp loading

  • Zan Li;Songyu Liu;Cuiwei Fu
    • Geomechanics and Engineering
    • /
    • v.35 no.4
    • /
    • pp.385-393
    • /
    • 2023
  • To analyze the consolidation with horizontal sand drains, the plane strain consolidation model under multi-ramp loading is established, and its corresponding analytical solution is derived by using the separation of variables method. The proposed solution is verified by the field measurement data and finite element results. Then, the effects of the loading mode and stress distribution on consolidation and dissipation of pore pressure are investigated. At the same time, the influence of hydraulic conductivity and thickness of sand blankets on soil consolidation are also analyzed. The results show that the loading mode has a significant effect on both the soil consolidation rate and generation-dissipation process of pore water pressure. In contrast, the influence of stress distribution on pore pressure dissipation is obvious, while its influence on soil consolidation rate is negligible. To guarantee the fully drained condition of the sand blanket, the ratio of hydraulic conductivity of the sand blanket to that of clay layer kd/kv should range from 1.0×104 to 1.0×106 with soil width varying from 100 m to 1000 m. A larger soil width correspondingly needs a greater value of kd/kv to make sure that the pore water can flow through the sand blanket smoothly with little resistance. When the soil width is relatively small (e.g., less than 100 m), the effect of thickness of the sand blanket on soil consolidation is insignificant. And its influence appears obvious gradually with the increase of the soil width.

Paper-based Electrochemical Sensor Using a Self-operated Paper Pump (자발 구동형 종이 펌프를 이용한 종이 전기화학 센서)

  • Si Hiep Hua;Chikwan Kim;Duc Cuong Nguyen;Yong Shin Kim
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.158-164
    • /
    • 2024
  • We developed a self-operated paper pump that can maintain a nearly constant flow rate of an aqueous solution along a paper strip channel in paper-based analytical devices (PADs). The quasi-stationary flow rate was controlled by increasing the crosssectional channel area (capillary force) using a fan-shaped absorption pad coupled with a paper strip channel. The flow rate is regulated by varying the fan angle of the circular absorbing pad. Furthermore, the flow rate can be increased by furnishing a hollow cavity at the center of a conventional paper strip channel. The rate was regulated by varying the length of the hollow paper channel in the flow rate range of 5.1-26.4 mm/min. As a preliminary work, a paper-pump-coupled PAD was fabricated, and its CV detection capability was evaluated for the redox reaction of Fe(CN)6+4/+3. The combination of a paper pump with a PAD resulted in an ideal CV curve with a higher limiting current and faster response time. These results are interpreted well by the Levich equation, which suggests that the paper pump is a very useful component in paper-based sensors.

Nondestructive Determination of Reinforcement Volume Fractions in Particulate Composites : Eddy Current Method (비파괴적 방법에 의한 입자 강화 복합재료의 부피분율 평가: 와전류법)

  • Jeong, Hyun-Jo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.2
    • /
    • pp.112-120
    • /
    • 1998
  • A nondestructive evaluation technique was developed for the quantitative determination of the reinforcement volume fractions in particulate reinforced metal matrix composites. The proposed technique employed a composite micromechanics which accounts for the microstructure of the composite medium together with the measurement of anisotropic electrical conductivity. When the measured conductivity was coupled with the theoretically predicted conductivity, the unknown reinforcement volume fraction was calculated. An analytical model based on the Mori-Tanaka method was described which relates the NDE signatures to the composite microstructure. The volume fractions were calculated using eddy current measurements made on a wide range of silicon carbide particulate ($SiC_p$) reinforced aluminum (Al) matrix composites. The calculated $SiC_p$ volume fractions were in good agreement with the measured volume fractions in the range of 0-30%. The technique was also found to be effective in estimating the total volume percentage of reinforcement and intermetallic compound formed during the processing stage.

  • PDF

Evaluation of Analytical Techniques for Some Gaseous Criteria Pollutants through a Field Measurement Campaign in Seoul, Korea (현장측정에 기초한 대기오염물질의 측정방식에 대한 비교연구-주요 기준성 오염물질을 중심으로)

  • 김세웅;김기현;김진석;이강웅;김경렬;문동민;김필수;손동헌
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.403-415
    • /
    • 1999
  • To properly assess air pollution levels, application of quality assurance and quality control(QA/QC) is believed to be an essential step. In order to cope with such scientific principle, a field study was designed with an aim of comparing: 1) the methods of calibration for airborne pollutants and 2) the protocols developed for their measurements. Measurements were made at Han Yang University, Seoul during 29 May through 1 June 1998 under the management of the Division of Measurements and Analysis(DMA) of Korean Society for Atmospheric Environment(KOSAE). In this work, we report our results of intercomparative measurements on several gaseous criteria pollutants that were investigated mainly by the two institutes-Seoul National University(SNU) and the Korean Research Institute for Standards and Science(KRISS). Although measurements of major gaseous pollutants had been made routinely by many scientific institutes and organizations in Korea, most scientists involved in those studieswere obliged to do their experiments on the basis of their own procedural steps spaning from the preparation of gaseous standards to the methodological selections for the calibration. Hence, this campaign offered a unique opportunity to examine many important aspects on the measurements of these important gaseous pollutants. In the course of our study, we investigated the compatibility of data sets obtained by the two institutes in concert with reference data sets collected concurrently from a government-managed monitoring station. On the basis of our study, we conclude that different data sets made by different participants during this campaign agree well within the reasonable range of uncertainties.low, which indicated that during this period the potential acidity of precipitation was high but the neutralizing capacity was low. For Spring, pAi was very low but pH was slightly high. This was likely due to the large amount of $CaCO_3$ in the soil particles transported over a long range from the Chinese continent that were incorporated into the precipitation, and then neutralized the acidifying species with its high concentraton.

  • PDF

Time Pickoff method using an Automatic Gain Control (자동 이득 조절(AGC) 기반의 Time pickoff 회로)

  • Lim, Han-Sang
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.4
    • /
    • pp.80-85
    • /
    • 2011
  • A time-pickoff circuit used for time measurement suffers from a timing error due to the dependence of the generation time of a timing pulse on the size of the input signal, i.e., time walk. In this study, a time-pickoff method, which employs an automatic gain control (AGC) circuit, is proposed for reducing the timing error. The AGC circuit is added to the input of the comparator, and it renders the sizes of input signals of the comparator relatively uniform. The performance of the proposed time-pickoff method is analyzed using the SPICE simulation, and experiments are performed to confirm the analytical results. The measured time walk is reduced to 2.000 ns by 65% for input signals with a dynamic range of 20 dB as compared to a typical leading-edge discriminator.

Development of relative radiometric calibration system for in-situ measurement spectroradiometers (현장관측용 분광 광도계의 상대 검교정 시스템 개발)

  • Oh, Eunsong;Ahn, Ki-Beom;Kang, Hyukmo;Cho, Seong-Ick;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.455-464
    • /
    • 2014
  • After launching the Geostationary Ocean Color Imager (GOCI) on June 2010, field campaigns were performed routinely around Korean peninsula to collect in-situ data for calibration and validation. Key measurements in the campaigns are radiometric ones with field radiometers such as Analytical Spectral Devices FieldSpec3 or TriOS RAMSES. The field radiometers must be regularly calibrated. We, in the paper, introduce the optical laboratory built in KOSC and the relative calibration method for in-situ measurement spectroradiometer. The laboratory is equipped with a 20-inch integrating sphere (USS-2000S, LabSphere) in 98% uniformity, a reference spectrometer (MCPD9800, Photal) covering wavelengths from 360 nm to 1100 nm with 1.6 nm spectral resolution, and an optical table ($3600{\times}1500{\times}800mm^3$) having a flatness of ${\pm}0.1mm$. Under constant temperature and humidity maintainance in the room, the reference spectrometer and the in-situ measurement instrument are checked with the same light source in the same distance. From the test of FieldSpec3, we figured out a slight difference among in-situ instruments in blue band range, and also confirmed the sensor spectral performance was changed about 4.41% during 1 year. These results show that the regular calibrations are needed to maintain the field measurement accuracy and thus GOCI data reliability.

A Study on the Factors Causing Analytical Errors through the Estimation of Uncertainty for Cadmium and Lead Analysis in Tomato Paste (불확도 추정을 통한 토마토 페이스트에서 카드뮴 및 납 분석의 오차 발생 요인 규명)

  • Kim, Ji-Young;Kim, Young-Jun;Yoo, Ji-Hyock;Lee, Ji-Ho;Kim, Min-Ji;Kang, Dae-Won;Im, Geon-Jae;Hong, Moo-Ki;Shin, Young-Jae;Kim, Won-Il
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.2
    • /
    • pp.169-178
    • /
    • 2011
  • BACKGROUND: This study aimed to estimate the measurement uncertainty associated with determination of cadmium and lead from tomato paste by ICP/MS. The sources of measurement uncertainty (i.e. sample weight, final volume, standard weight, purity, molecular weight, working standard solution, calibration curve, recovery and repeatability) in associated with the analysis of cadmium and lead were evaluated. METHODS AND RESULTS: The guide to the expression of uncertainty was used for the GUM (Guide to the expression of Uncertainty in Measurement) and Draft EURACHEM/CITAC (EURACHEM: A network of organization for analytical chemistry in Europe/Co-Operation on International Traceability in Analytical Chemistry) Guide with mathematical calculation and statistical analysis. The uncertainty components were evaluated by either Type A or Type B methods and the combined standard uncertainty were calculated by statistical analysis using several factors. Expected uncertainty of cadmium and lead was $0.106{\pm}0.015$ mg/kg (k=2.09) and $0.302{\pm}0.029$ mg/kg (k=2.16), on basis of 95% confidence of Certified Reference Material (CRM) which was within certification range of $0.112{\pm}0.007$ mg/kg for cadmium (k=2.03) and $0.316{\pm}0.021$ mg/kg for lead (k=2.01), respectively. CONCLUSION(s): The most influential components in the uncertainty of heavy metals analysis were confirmed as recovery, standard calibration curve and standard solution were identified as the most influential components causing uncertainty of heavy metal analysis. Therefore, more careful consideration is required in these steps to reduce uncertainty of heavy metals analysis in tomato paste.