• Title/Summary/Keyword: Analytical ability

Search Result 260, Processing Time 0.027 seconds

A Study on the Elements(MORT-TAC) of Situation Assessment at Disaster Sites (재난현장 상황평가 고려요소(MORT-TAC)에 관한 연구)

  • Kim, Sung-Geun;Lee, Young-Jai
    • Journal of Digital Convergence
    • /
    • v.15 no.1
    • /
    • pp.117-127
    • /
    • 2017
  • Even well trained personnel may fall victim to panic, and a wrong assessment of the situation can turn a small accident into a huge disaster. At the disaster site, the event is commonly broadcasted in real time and is unfiltered. Thus, the commander of the site must be able to accurately assess the scene while not missing out on key considerations. Despite the necessity of good situational assessment, there is barely any research on this topic. This study utilizes METT-TC(Mission, Enemy, Troops, Terrain and weather, Time available, and Civil considerations) which is used by militaries to assess combat situations, and proposes MORT-TAC(Mission, Object, Resources available, Terrain and weather, Time available, Ability, and Civil considerations) as factors to consider in effectively controlling the disaster site. The standard model is used for assessing disaster scenes by applying the Delphi analytical method on each sub-factor of MORT-TAC.

Digital Competencies Required for Information Science Specialists at Saudi Universities

  • Yamani, Hanaa;AlHarthi, Ahmed;Elsigini, Waleed
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.2
    • /
    • pp.212-220
    • /
    • 2021
  • The objectives of this research were to identify the digital competencies required for information science specialists at Saudi universities and to examine whether there existed conspicuous differences in the standpoint of these specialists due to years of work experience with regard to the importance of these competencies. A descriptive analytical method was used to accomplish these objectives while extracting the required digital competency list and ascertaining its importance. The research sample comprised 24 experts in the field of information science from several universities in the Kingdom of Saudi Arabia. The participants in the sample were asked to complete a questionnaire prepared to acquire the pertinent data in the period between January 5, 2021 and January 20, 2021. The results reveal that the digital competencies required for information science specialists at Saudi universities encompass general features such as the ability to use computer, Internet, Web2, Web3, and smartphone applications, digital learning resource development, data processing (big data) and its sharing via the Internet, system analysis, dealing with multiple electronic indexing applications and learning management systems and its features, using electronic bibliographic control tools, artificial intelligence tools, cybersecurity system maintenance, ability to comprehend and use different programming languages, simulation, and augmented reality applications, and knowledge and skills for 3D printing. Furthermore, no statistically significant differences were observed between the mean ranks of scores of specialists with less than 10 years of practical experience and those with practical experience of 10 years or more with regard to conferring importance to digital competencies.

The Creator Economy on the Metaverse Platform (메타버스 플랫폼의 크리에이터 이코노미: 광고수입 모델과 수익배분 구조를 중심으로)

  • Kim, Eunjin
    • Journal of Intelligence and Information Systems
    • /
    • v.28 no.4
    • /
    • pp.275-286
    • /
    • 2022
  • The metaverse platform has been gaining popularity since the pandemic. It facilitates non-face-to-face interaction among creators, users, advertisers, various forms of organizations, and itself. Such interaction has brought light to the new forms of economy, which is called the "creator economy." By providing the virtual space, easy tools, and methods, the platform allows the creators to produce value for the users in the forms of virtual items, content, and experiences. At the same time, it provides audiences to the organizations that need attention. In the course, the platform and the creators generate revenue. Among the diverse revenue sources, this study focuses on revenue generated from advertising and studies how the revenue sharing between the platform and the creator is affected by the abilities of the metaverse platform. With an analysis of the analytical model, we show that if the platform has the ability to reduce advertising avoidance, it can reduce the revenue share of the creator without discouraging the creator from making the proper effort in content creation. Also, as the platform provides effective tools and methods for quality content creation, it can reduce the revenue share of the creator without damaging the creator's required motivation. The ability of the platform in increasing advertising effectiveness helps it to reduce the revenue share of the creator as well.

The expected teacher knowledge in elementary school teacher employment tests for mathematics (초등학교 교원 임용후보자 선정경쟁시험 수학과 문항에서 요구되는 지식 분석)

  • Eun Hyun Kim;Rae Young Kim
    • The Mathematical Education
    • /
    • v.63 no.1
    • /
    • pp.85-104
    • /
    • 2024
  • This study aims to analyze the mathematics items of the 2013-2024 elementary school teacher employment tests in order to identify the knowledge and characteristics required to teach mathematics, and discuss the future direction of improvement of the elementary school teacher employment tests. By using the revised analytical framework of TEDS-M, we found that the proportion of MCK and MPCK differed from year to year and MPCK was relatively dominant. We also observed that the items were heavily focused on particular knowledge domains, cognitive processes, and levels within MCK and MPCK, and a shortage of items desigend to asseess knowledge in the field of assessments and the ability to engage in higher-order thinking. The results from this study suggest the future direction of improvement of the elementary school teacher employment test to evaluate teacher knowledge and ability necessary in an increasingly diverse society.

Analytical Determination of Vitamin B12 Content in Infant and Toddler Milk Formulas by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

  • Lee, Jung-Hoon;Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • Food Science of Animal Resources
    • /
    • v.35 no.6
    • /
    • pp.765-771
    • /
    • 2015
  • The development of a sample preparation method and optimization of the analytical instrumentation conditions were performed for the determination of the vitamin B12 content in emulsified baby foods sold on the Korea market. After removal of the milk protein and fats by chloroform extraction and centrifugation, the vitamin B12 was water extracted from the sample. Following filtration of the solution through a nylon filter, the water-soluble extract was purified by solid-phase extraction using a Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS). The solution eluted from the cartridge was dried under a stream of nitrogen gas and reconstituted with 1 mL of water. The sample solution was injected into an LC-MS/MS system after optimizing the mobile phase for vitamin B12 detection. The calibration curve showed good linearity with the coefficient of correlation (r2) value of 0.9999. The limit of detection was 0.03 µg/L and the limit of quantitation was 0.1 µg/L. The method of detection limit was 0.02 µg/kg. The vitamin B12 recovery from a spiking test was 99.62% for infant formula and 99.46% for cereal-based baby food. The sample preparation method developed in this study would be appropriate for the rapid determination of the vitamin B12 content in infant formula and baby foods with emulsified milk characteristics. The ability to obtain stable results more quickly and efficiently would also allow governments to exercise a more extensive quality control inspection and monitoring of products expected to contain vitamin B12. This method could be implemented in laboratories that require time and labor saving.

Study on identification of plastic used for modern artwork (플라스틱류 작품의 동정 기술 연구)

  • Yu, Ji A;Chung, Yong Jae;Ham, Seung Wook
    • Analytical Science and Technology
    • /
    • v.27 no.2
    • /
    • pp.100-107
    • /
    • 2014
  • Plastic has been widely used in modern artworks' materials due to its merits of process ability and mass production. In the country, value of plastic artifact is increasing but the field of plastic study is limited to industrial purpose. In this study, Identification methods of plastic were performed by SPME-GC/MS and pyrolysis-GC/MS using trace of samples. As a result of identification using SPME-GC/MS, aromatic compounds were identified from polyvinyl chloride. And alkane compounds were identified from polyethylene, and polypropylene. Aromatic compounds were identified from polystyrene, and diethylene glycol appeared in polyurethane based on polyester was identified from polyurethane. As a result of identification using pyrolysis- GC/MS, aliphatic alkenes compounds and phthalate(DEHP) were identified from polyvinyl chloride. Aliphatic alkenes compounds and phthalate(DIBP) were detected from polyethylene. 1-hexene, etc., were detected from polypropylene, aromatic compounds were identified from polystyrene, and methylene diphenyl diisocyanate which is polyurethane basic material was confirmed from polyurethane. This study suggested that non-destructive SPME and pyrolysis-GC/MS are useful to identify compounds particularly polystyrene and polyurethane. These two analytical methods were expected to be applied for identification of unidentified plastic artworks before conservation treatment.

Inter-laboratory Comparison for Analyses of Heavy Metals and Organic Solvent Metabolites in Biological Samples (생체시료 중 중금속 및 유기용제 대사물 분석의 실험실간 정도관리 프로그램)

  • Yang, Jeong Sun;Lee, Mi Young;Park, In Jeong;Kang, Seong-Kyu
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.258-267
    • /
    • 2000
  • The result of five year's experience on Inter-laboratory Comparison for Analyses of Heavy Metals and Organic Solvent Metabolites in Biological Samples was described. Since 1995, around a hundred laboratories in the Occupational Health have participated this program twice per year by the Industrial Safety and Health Law. Four metals in blood and five organic solvent metabolites in urine were examined. Reference samples were made by spiking standard materials to human blood or urine pools treated previously to give homogeneity and stability for a specific time periods. Some reference samples for organic solvent metabolites were made from workers' urine who were exposed to the organic solvents. Some items such as Lead in blood and Hippuric acid in urine showed good accordance between participants while the other items such as Mercury and N-methylformamide in urine showed poor proficient rate. The results were published in the internet or newspaper to help the consumer of the laboratory's service to get the information on them and to make competition between them. The inter-laboratory's comparison program have done greate role to improve the ability of analysis and reliability of analytical data produced from each laboratory.

  • PDF

Comparison of the Quantulus 1220 and 300SL Liquid Scintillation Counters for the Analysis of 222Rn in Groundwater

  • Kim, Hyuncheol;Jung, Yoonhee;Lee, Wanno;Choi, Guen-Sik;Chung, Kun Ho;Kang, Mun Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.395-401
    • /
    • 2016
  • Background: Liquid scintillation counters (LSCs) are commonly used as an analytical method for detecting $^{222}Rn$ in groundwater because they involve a simple sample pretreatment and allow high throughout with an autosampler. The Quantulus 1220 is the best-selling LSC in Korea, but its production was stopped. Recently, a new type of LSC, the 300SL, was introduced. In this study, the 300SL was compared with the Quantulus 1220 in order to evaluate the ability of each apparatus to detect $^{222}Rn$ in groundwater. Materials and Methods: The Quantulus 1220 and 300SL were used to detect the presence of $^{222}Rn$. Radon gas was extracted from a groundwater sample using a water-immiscible cocktail in a LSC vial. The optimal analytical conditions for each LSC were determined using a $^{222}Rn$ calibration source prepared with a $^{226}Ra$ source. Results and Discussion: The optimal pulse shape analysis level for alpha and beta separation was 80 for the Quantulus 1220, and the corresponding pulse length index was 12 in the 300SL. The counting efficiency of the Quantulus 1220 for alpha emissions was similar to that of the 300SL, but the background count rate of the Quantulus 1220 was 10 times lower than that of the 300SL. The minimum detectable activity of the Quantulus 1220 was $0.08Bq{\cdot}L^{-1}$, while that of the 300SL was $0.20Bq{\cdot}L^{-1}$. The analytical results regarding $^{222}Rn$ in groundwater were less than 10% different between these LSCs. Conclusion: The 300SL is an LSC that is comparable to the Quantulus 1220 for detecting $^{222}Rn$ in groundwater. Both LSCs can be applied to determine the levels of $^{222}Rn$ in groundwater under the management of the Ministry of Environment.

An Empirical Study of the Analytical Measurement Range in Clinical Chemistry (분석측정범위의 실증적 평가)

  • Chang, Sang-Wu;Lee, Sang-Gon;Kim, Young-Hwan;Song, Eun-Young;Park, Yong-Won;Park, Byong-Ok;Lyu, Jae-Gi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.117-124
    • /
    • 2006
  • The analytical measurement range (AMR) is the range of analyte values that a method can directly measure on a specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. The linearity of the AMR is its ability to obtain test results which are directly proportional to the concentration of analyte in the sample from the upper and lower limit of the AMR. The AMR validation is the process of confirming that the assay system will correctly recover the concentration or activity of the analyte over the AMR. The test specimen must have analyte values which, at a minimum, are near the low, midpoint, and high values of the AMR. The AMR must be revalidated at least every six months, at changes in major system components, and when a complete change in reagents for a procesure is introduced; unless the laboratory can demonstrate that changing the reagent lot number does not affect the range used to report patient test results. The AMR linearity was total protein (0-16.6), albumin (0-8.1), total bilirubin (0-18.1), alkaline phosphatase (0-1244.3), aspartate aminotransferase (0-1527.9), alanine aminotransferase (0-1107.9), gamma glutamyl transpeptidase (0-1527.7), creatine kinase (0-1666.6), lactate dehydrogenase (0-1342), high density lipoprotein cholesterol (0.3-154.3), sodium (35.4-309), creatinine (0-19.2), blood urea nitrogen (0.5-206.2), uric acid (0-23.9), total cholesterol (-0.3-510), triglycerides (0.7-539.6), glucose (0-672.7), amylase (0-1595.3), calcium (0-23.9), inorganic phosphorus (0.03-17.0), potassium (0.1-116.5), chloride (3.3-278.7). We are sure that materials for the AMR affect the evaluation of the upper limit of the AMR in the process system.

  • PDF

A Study on the Cleanliness Evaluation Methods for the Selection of Alternative Cleaning Agents (대체 세정제의 선정을 위한 세정성 평가방법 연구)

  • Shin, Jin-Ho;Lee, Jae-Hoon;Bae, Jae-Heum;Lee, Min-Jae;Hwang, In-Gook
    • Clean Technology
    • /
    • v.15 no.2
    • /
    • pp.81-90
    • /
    • 2009
  • In this study various cleaning evaluation methods were tested and comparatively evaluated to help cleaning industry. In order to select alternative cleaning agents objectively and systematically, various cleaning evaluation methods such as gravimetric, optically simulated electron emission (OSEE), contact angle, and analytical instrument methods were employed for cleaning contaminants such as flux, solder and grease. The analytical instruments used in this work were Fourier transform infrared spectroscopy (FTIR), ultraviolet visible spectroscopy (UV-VIS) and high performance liquid chromatography (HPLC). The gravimetric method was able to measure cleaning efficiencies easily and simply, but it was not easy to analyze them precisely because of its limitation in the gravimetric measurement. However, the OSEE technique was able to measure quickly and precisely the clean ability of cleaning agents in comparison with the gravimetric method. The contact angle method was found to be necessary for taking special precaution in its application to the cleaning evaluation due to possible formation of tiny organic film on the substrate surface which might be generated from contaminants and cleaning agents. In case of precision analysis that cannot be done by gravimetric method, fine analytical instruments such as UV-VIS, FTIR and HPLC could be used in analyzing trace amount of flux, solder and grease quantitatively, which were extracted from the surface by special solvents.