• Title/Summary/Keyword: Analytical Chromatography

Search Result 1,121, Processing Time 0.025 seconds

Monitoring of arsenic and arsenic species in fish collagen in Korea (국내 유통 어류 콜라겐의 총비소 및 비소화학종 함량 모니터링)

  • Yeo-Jae Shin;Mi-Ra Jang;Eun-Hee Kim;Yun-Hee Kim;Min-Jung Kim;Min-Jung Kim;Jae-Hoon Cha;Mi-Hyun Choi;Seok-Ju Cho;In-Sook Hwang;Yong-Seung Shin
    • Analytical Science and Technology
    • /
    • v.36 no.3
    • /
    • pp.135-142
    • /
    • 2023
  • The total arsenic and 6 arsenic species were investigated in 56 fish collagen products using ICP-MS (Inductively coupled plasma-mass spectrometer) and HPLC-ICP-MS(High performance liquid chromatography-Inductively coupled plasma-mass spectrometer). The mean concentrations of total arsenic and arsenic species were 40.103±81.133 ㎍/kg (N.D.~586.686) and 30.070±50.378 ㎍/kg (N.D.~313.871), respectively. The mean concentration of inorganic arsenic was 24.610±32.706 ㎍/kg (N.D.~129.331), and the As(V) (Arsenate) was the most dominant. The standards and specifications of arsenic have not been established for fish collagen products. Our study presents that arsenic levels are relatively safe compared with not only previous studies but also domestic and international standards. However, in one sample, the total arsenic concentration was 586.686 ㎍/kg, showing the inorganic was 8.119 ㎍/kg, and the DMA was 305.752 ㎍/kg, which was high than the Canadian standard for organic arsenic. In conclusion, it is necessary to monitor arsenic levels consistently and establish standards and specifications of arsenic in fish collagen products to assure consumer safety.

Analytical Method for Determination of Laccaic Acids in Foods with HPLC-PDA and Monitoring (식품 중 락카인산 성분 분리정제를 통한 분석법 확립 및 실태조사)

  • Jae Wook Shin;Hyun Ju Lee;Eunjoo Lim;Jung Bok Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.5
    • /
    • pp.390-401
    • /
    • 2023
  • Major components of lac coloring include laccaic acids A, B, C, and E. The Korean Food Additive Code regulates the use of lac coloring and prohibits its use in ten types of food products including natural food products. Since no commercial standards are available for laccaic acids A, B, C, and E, a standard for lac pigment itself was used to separate laccaic acids from the lac pigment molecule. A standard for each laccaic acid was then obtained by fractionation. To obtain pure lac pigment for use in food by High performance Liquid Chromatography Photo Diode Array (PDA), a C8 column yielded the best resolution among various tested columns and mobile phases. A qualitative analytical method using High Performance Liquid Chromatography (HPLC) Tandem Mass(LC-MS/MS) was developed. The conditions for fast and precise sample preparation begin with extraction using methanol and 0.3% ammonium phosphate, followed by concentration. The degree of precision observed for the analyses of ham, tomato juice and Red pepper paste was 0.3-13.1% (Relative Standard Deviation (RSD%)), degree of accuracy was 90.3-122.2% with r2=0.999 or above, and recovery rate was 91.6-114.9%. The limit of detection was 0.01-0.15 ㎍/mL, and the limits of quantitation ranged from 0.02 to 0.47 ㎍/mL. Lac pigment was not detected in 117 food products in the 10 food categories for which the use of lac pigment is banned. Multiple laccaic acids were detected in 105 food products in 6 food categories that are allowed to use lac color. Lac pigment concentrations range from 0.08 to 16.67 ㎍/mL.

Determination of Soluble Carbohydrates in Soybean Seeds Using High Performance Liquid Chromatography with Evaporative Light Scattering Detection (증기화광산란 검출기를 이용한 콩 함유 수용성 탄수화물의 분석)

  • Kim, Gyeong-Ha;Hwang, Young-Sun;Ahn, Kyung-Geun;Kim, Gi-Ppeum;Kim, Min-Ji;Hong, Seung-Beom;Moon, Jung-Kyeong;Choung, Myoung-Gun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.7
    • /
    • pp.1062-1067
    • /
    • 2014
  • In the present study, a new analytical method was devised for the simultaneous determination of soluble carbohydrates in soybean seeds using high performance liquid chromatography/evaporative light scattering detection (HPLC/ELSD). The limit of quantification (LOQ) for soybean soluble carbohydrates ranged from 5.6~7.6 mg/kg using the HPLC/ELSD method and from 16.2~33.9 mg/kg using the high performance liquid chromatography/refractive index detection (HPLC/RID) method. Therefore, the HPLC/ELSD method was more sensitive than HPLC/RID. The precision values for retention time and peak area of the HPLC/ELSD method were evaluated by inter-day (n=5) and intra-day (n=10) assays using a standard solution. All precision values (CV<2.5%) for soybean soluble carbohydrates were acceptable and fulfilled international acceptance criteria. All linear calibration curves were obtained with a correlation coefficient of $R^2$ >0.999. The contents of soluble carbohydrates for the "Shingikong" (yellow soybean) and "Cheongjakong 3" (black soybean) samples were analyzed using the HPLC/RID and HPLC/ELSD methods. The difference in carbohydrate contents between the two detection methods was significant. Carbohydrate contents in the HPLC/ELSD method were higher than those in the HPLC/RID method. Overall, the HPLC/ELSD method showed satisfactory resolution with a favorable LOQ and reproducibility. Therefore, these results indicate that the HPLC/ELSD method may be applied to determine the contents of soluble carbohydrates in soybean seeds and related food stuffs.

Analysis of ethyl glucuronide (EtG) in Hair for the diagnosis of chronic alcohol abuse of Korean (한국인의 만성 알코올 중독 진단을 위한 모발에서 Ethyl Glucuronide (EtG) 분석법 연구)

  • Gong, Bokyoung;Jo, Young-Hoon;Ju, Soyeong;Min, Ji-Sook;Kwon, Mia
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.151-158
    • /
    • 2020
  • Alcohol, which can easily be obtained in the same way as ordinary beverages, is harmful enough to cause death due to excessive drinking and chronic alcohol intake, so it is important to maintain a proper amount of drinking and healthy drinking habits. In addition, the incidence of behavioral disturbances and impaired judgments that can be caused by chronic alcohol drinking of more than adequate amounts of alcohol is also significant. Accordingly it is very useful for forensic science to check whether the person involved is drunken or is alcoholism state in various accidents. Currently, in Korea, alcohol consumption is determined by detecting the level of alcohol or alcohol metabolism 'ethyl glucuronide (EtG)' in blood or urine samples. However, analysis of alcohol or EtG in blood or urine can only provide information about the current state of alcohol consumption because of a narrow window of detection time. Therefore, it is important to analyze the EtG as a long-term direct alcohol metabolite bio-marker in human hair and to investigate relationship between alcohol consumption and EtG concentration for the evaluation of chronic ethanol consumption. In this study, we established an analytical method for the detection of EtG in Korean hair efficiently and validated selectivity, linearity, limits of detection (LOD), limits of quantification (LOQ), matrix effect, recovery, process efficiency, accuracy and precision using liquid chromatography tandem mass spectrometry (LC-MS/MS). In addition, the assay performance was evaluated in Korean social drinker's hair and the postmortem hair of a chronic alcoholism. The results of this study can be useful in monitoring the alcohol abuse of Korean in clinical cases and legal procedures related to custody and provide a useful tool to evaluate postmortem diagnosis of alcoholic ketoacidosis in forensics.

Determination of homogentisic acid in human plasma by GC-MS for diagnosis of alkaptonuria (GC-MS를 이용한 혈장 중 호모겐티식산의 분석;알캅톤뇨증의 진단)

  • Thapa, Maheshwor;Yu, Jundong;Lee, Wonjae;Islam, Fokhrul;Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.323-330
    • /
    • 2015
  • Alkaptonuria, a rare inherited metabolic disease, is characterized by a lack of homogentisate dioxygenase and accumulation of homogentisic acid (HGA), leading to homogentisic aciduria, arthritis, and ochronosis. In this study, a rapid analytical method, without an expensive and tedious solid phase extraction step, was developed to quantify HGA in plasma using GC-MS. HGA-spiked pooled plasma samples were subjected to liquid-liquid extraction (LLE) with ethyl acetate, followed by trimethylsilyl derivatization (TMS) and GC-MS quantification using selected ion monitoring. The formation of TMS derivative of the 1 carboxylic and 2 hydroxyl functional groups was performed by reacting BSTFA (with 10% TMCS) for 5 min at 80 ℃. For selected ion monitoring, quantification and confirmation ions were determined based on specific ions (m/z 384, m/z 341 and m/z 252) of the TMS derivative of HGA. Calibration curves of pooled normal plasma specimens showed a linear relationship in the range of 1-100 ng/µL. The precision and accuracy were within a relative standard deviation (RSD) of 1 to 15% and a bias of -5 to 25%. Recoveries were obtained in the range of 99-125% and 95-115% for intra-day and inter-day assay, respectively, at 2, 20 and 80 ng/µL. The limit of detection (LOD) and limit of quantification (LOQ) were 0.4 ng/µL and 4 ng/µL, respectively. No homogentisic acid was excreted from normal Korean plasma samples. Collectively, the results from the present study suggest that this method could be useful for routine diagnosis and therapeutic monitoring of alkaptonuria patients with excellent sensitivity and rapidity.

The analysis of ethylene glycol and metabolites in biological specimens (생체시료에서 에틸렌 글리콜과 그 대사체 분석에 관한 연구)

  • Park, Seh-Youn;Kim, Yu-Na;Kim, Nam-Yee
    • Analytical Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.69-77
    • /
    • 2011
  • Ethylene glycol (EG) is produced commercially in large amounts and is widely used as antifreeze or deicing solution for cars, boats, and aircraft. EG poisoning occurs in suicide attempts and infrequently, either intentionally through misuse or accidental as EG has a sweet taste. EG has in itself a low toxicity, but is in vivo broken down to higher toxic organic acids which are responsible for extensive cellular damage in various tissues caused principally by the metabolites glycolic acid and oxalic acid. The most conclusive analytical method of diagnosing EG poisoning is determination of EG concentration. However, victims are sometimes admitted at a late stage to hospitals or died during emergency treatment like a gastric lavage or found rotten dead, when blood EG concentrations are low or not detected. Therefore, in this study, the identification of EG was not only performed by gas chromatograpyc-mass spectrometry (GC-MS) following derivatization but also further toxicological analyses of metabolites, glycolic acid (GA) and oxalic acid (OA), were performed by ion chromatography in various biological specimens. A ranges of blood concentrations (3 cases) was $10\sim2,400\;{\mu}g/mL$ for EG, $224\sim1,164\;{\mu}g/mL$ for GA and ND $\sim40\;{\mu}g/mL$ for OA, respectively, In other biological specimens (liver, kidney, bile and pleural fluid), a range of concentrations (3 cases) was ND $\sim55,000\;{\mu}g/mL$ for EG, ND $\sim1,124\;{\mu}g/mL$ for GA and ND $\sim60\;{\mu}g/mL$ for OA, respectively. Liver and kidney tissues were recommended specimens including blood because OA, a final metabolite of EG, was identified large amounts in these despite no detectable EG caused by some therapy.

Establishment of an Analytical Method for Novobiocin in Livestock Products Using HPLC-UVD (HPLC-UVD를 이용한 축산식품 중 Novobiocin의 시험법 확립)

  • Park, Hee-Ra;Kwon, Chan-Hyeok;Lee, Jong-Goo;Kim, Hyung-Soo;Chae, Young-Sik;Oh, Jae-Ho;Kwon, Ki-Sung
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.3
    • /
    • pp.263-268
    • /
    • 2012
  • Novobiocin is a coumarin-containing antibiotic, and has a longer half-life in various animals than other veterinary medicines. A simple and rapid high-performance liquid chromatography assay for the determination of residual novobiocin levels in chicken, beef and milk has been developed and validated. The separation condition for HPLC/UVD was optimized by a MG II $C_{18}$ (4.6 mm $ID{\times}250$ mm, 5 ${\mu}m$) column with 0.1% formic acid in $H_2O$/0.1% formic acid in Acetonitrile (40/60, v/v) as the mobile phase at a flow rate of 1.0 mL/min and the detection wavelength was set at 340 nm. Residues were extracted from tissue by blending with methanol. After liquid-liquid partitioning, lipid materials were removed with n-hexane and purification as Silica (1 g, 6 mL) cartridge with 10 mL acetone/dichloromethane (10/90, v/v). Limit of quantification and linearity performed by the analytical method were 0.02 mg/kg and 0.999 ($r^2$), and the recovery range was $88.8{\pm}5.6-100.3{\pm}4.4$, $88.8{\pm}7.2-97.0{\pm}3.2$ and $88.1{\pm}4.3-92.8{\pm}3.6%$. It is expected that this analytical method with regards to novobiocin in chicken, beef and milk could be applied as an official method to administer food safety on veterinary medicines.

Development of Analytical Method for Ergot Alkaloids in Foods Using Liquid Chromatoraphy-Tandem Mass Spectrometry (LC-MS/MS를 이용한 식품 중 맥각 알칼로이드 시험법 개발)

  • Chun, So Young;Chong, Euna;Lee, Bomnae;Kwon, Jin-Wook;Park, Hye Young;Kim, Sheenhee;Gang, Giljin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.2
    • /
    • pp.158-169
    • /
    • 2019
  • Ergot alkaloids are mycotoxin produced by fungi of the Claviceps genus, mainly by Claviceps purpurea in EU. Recently obtained informations indicates necessity for control the ergot in imported grains. Recent occurrence data of ergot alkaloids from EU countries indicate the necessities of management and control these toxins from the imported grains like rye, wheat, oat etc. The aim of this study is to optimize the liquid chromatography-tandem mass spectrometry method for determination of ergot alkaloids (ergometrine, ergosine, ergotamine, ergocornine, ergocryptine, ergocristine and their epimers (-inines) from grain and grain-based food. The test method was optimized by extracting the sample with acetonitrile containing 2 mM ammonium carbonate, purification with Mycosep cartridge, and instrumental analysis by LC-MS/MS using Syncronis C18 column. The standard calibration curves showed linearity with correlation coefficents; $R^2$ >0.99. Mean recoveries ranged from 72.0 to 111.3% at three different fortified levels (20, 50, and $100{\mu}g/kg$). The correlation coefficient expressed as precision was within the range of 1.9-12.9%. The limit or quantifications (LOQ) ranged from 0.012 to $0.058{\mu}g/kg$. The developed analytical method met the criteria of AOAC Int. and CAC validation parameters like accuracy and sensitivity. As a result, it was confirmed that the test method developed in this study is suitable for the simultaneous analysis of six species of ergot alkaloid from grains and grain products.

Development of simultaneous analytical method for investigation of ketamine and dexmedetomidine in feed (사료 내 케타민과 덱스메데토미딘의 잔류조사를 위한 동시분석법 개발)

  • Chae, Hyun-young;Park, Hyejin;Seo, Hyung-Ju;Jang, Su-nyeong;Lee, Seung Hwa;Jeong, Min-Hee;Cho, Hyunjeong;Hong, Seong-Hee;Na, Tae Woong
    • Analytical Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.136-142
    • /
    • 2022
  • According to media reports, the carcasses of euthanized abandoned dogs were processed at high temperature and pressure to make powder, and then used as feed materials (meat and bone meal), raising the possibility of residuals in the feed of the anesthetic ketamine and dexmedetomidine used for euthanasia. Therefore, a simultaneous analysis method using QuEChERS combined with high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry was developed for rapid residue analysis. The method developed in this study exhibited linearity of 0.999 and higher. Selectivity was evaluated by analyzing blank and spiked samples at the limit of quantification. The MRM chromatograms of blank samples were compared with those of spiked samples with the analyte, and there were no interferences at the respective retention times of ketamine and dexmedetomidine. The detection and quantitation limits of the instrument were 0.6 ㎍/L and 2 ㎍/L, respectively. The limit of quantitation for the method was 10 ㎍/kg. The results of the recovery test on meat and bone meal, meat meal, and pet food showed ketamine in the range of 80.48-98.63 % with less than 5.00 % RSD, and dexmedetomidine in the range of 72.75-93.00 % with less than 4.83 % RSD. As a result of collecting and analyzing six feeds, such as meat and bone meal, prepared at the time the raw material was distributed, 10.8 ㎍/kg of ketamine was detected in one sample of meat and bone meal, while dexmedetomidine was found to have a concentration below the limit of quantitation. It was confirmed that the detected sample was distributed before the safety issue was known, and thereafter, all the meat and bone meal made with the carcasses of euthanized abandoned dogs was recalled and completely discarded. To ensure the safety of the meat and bone meal, 32 samples of the meat and bone meal as well as compound feed were collected, and additional residue investigations were conducted for ketamine and dexmedetomidine. As a result of the analysis, no component was detected. However, through this investigation, it was confirmed that some animal drugs, such as anesthetics, can remain without decomposition even at high temperature and pressure; therefore, there is a need for further investigation of other potentially hazardous substances not controlled in the feed.

Modification and Validation of an Analytical Method for Dieckol in Ecklonia Stolonifera Extract (곰피추출물의 지표성분 Dieckol의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Oh, Geon;Jin, Heegu;Oh, Hyun-Ji;Kim, Eunjin;Kim, Jongwook;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.143-148
    • /
    • 2022
  • This study was to investigate an analytical method for determining dieckol content in Ecklonia stolonifera extract. According to the guidelines of International Conference on Harmonization. Method validation was performed by measuring the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of dieckol using high-performance liquid chromatography-photodiode array. The results showed that the correlation coefficient of calibration curve (R2) for dieckol was 0.9997. The LOD and LOQ for dieckol were 0.18 and 0.56 ㎍/mL, respectively. The intra- and inter-day precision values of dieckol were approximately 1.58-4.39% and 1.37-4.64%, respectively. Moreover, intra- and inter-day accuracies of dieckol were approximately 96.91-102.33% and 98.41-105.71%, respectively. Thus, we successfully validated the analytical method for estimating dieckol content in E. stolonifera extract.