• Title/Summary/Keyword: Analysis Response Spectrum

Search Result 751, Processing Time 0.028 seconds

Seismic Performance Evaluation According to Seismic Retrofit Techniques of Existing School Buildings (기존 학교건축물의 내진보강기법에 따른 내진성능평가)

  • Kang, Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.15 no.1
    • /
    • pp.29-36
    • /
    • 2012
  • Reinforced concrete shear walls and X-type steel braces were applied in seismic retrofit techniques for seismic performance evaluation of school buildings constructed in accordance with standard design announced by the ordinance of the ministry of construction in 1980s. Seismic performance evaluation was based on FEMA 356 using response spectrum as elastic analysis and conducted to pushover analysis with nonlinear static analysis. The maximum displacement ratio between floors in 4th and 3rd floors of the existing school buildings was less than 1.0%, which was functioning level in FEMA 356. However, because plastic hinge occurs somewhat in structural members according to the results of pushover analysis, partial reinforcement will be required. X-direction of the maximum lateral displacement of reinforced concrete shear walls than X-type steel braces was 45% and 32% in 4th and 3rd floors of school buildings, and Y-direction was 18% and 17%, respectively.

Multi-Step Analysis of Seismically Isolated NPP Containment Structures with Lead-Rubber Bearings (납-고무받침에 의해 면진된 원전 격납구조물의 다중단계해석)

  • Lee, Jin Hi;Song, Jong-Keol;Lee, Eun-Haeng
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.261-269
    • /
    • 2014
  • In order to increase the seismic safety of nuclear power plant (NPP) structures in high seismicity regions, seismic isolation techniques can be adapted to NPP structures. In this paper, the applicability of multi-step analysis of seismically isolated NPP containment structures with lead-rubber bearings (LRB) is evaluated. The floor response spectrum of NPP containment structures with equivalent linear LRB and nonlinear LRB are compared. In addition, the force-displacement relationships for equivalent linear LRB and nonlinear LRB are compared.

Seismic Qualification Analysis for the Power Transformer with IEEE Std 693-1997 (IEEE Std 693-1997을 적용한 전력용 변압기 내진 해석)

  • Yang J.C.;Roh H.C.;Kim H.Y.;Park K.S.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.12
    • /
    • pp.527-531
    • /
    • 2005
  • Because of increasing demand for safety of the power transformer, the seismic qualification process in accordance with the standard of IEEE Std 693-1997 is essentially required by customer. Dynamic analysis method and static analysis method were used to qualify the seismic withstanding of the power transformer at high seismic level. Maximum stress was detected at the connection between the main structure and appendages, and maximum displacement was detected at the point of appendage's end tip. Load path and substructure system can be considered as important elements to prevent over stress and over displacement.

Design of Viscous Dampers Using Nonlinear Static Analysis (비탄성 정적해석을 이용한 점성감쇠기의 설계)

  • 김진구;최현훈
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.10a
    • /
    • pp.257-264
    • /
    • 2000
  • Nonlinear dynamic time history analysis of a structure with energy dissipation devices is complicated and time consuming. In this regard the nonlinear static analysis is a practical alternative for evaluating the earthquake resisting capacity of a structure. In this study the nonlinear static response of a structure was obtained first, and the equivalent viscous modal damping ratio required to satisfy the performance objective was computed in the capacity spectrum format. Then proper amount of viscous dampers were installed to provide the required damping. Parametric study has been performed for the period of the structure, yield strength, and the stiffness after the first yield. According to the earthquake time history analysis results, the maximum displacement of the model structure with viscous dampers designed in accordance with the proposed method corresponds well with the target displacements that was used in the beginning of the design process.

  • PDF

Fluid effect on the modal characteristics of a square tank

  • Jhung, Myung Jo;Kang, Sung-Sik
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1117-1131
    • /
    • 2019
  • Tanks are used extensively in many engineering areas for spent fuel pool structures at nuclear power plants or for water storage tanks in bulk carriers. To ensure the structural integrity of such tanks when under dynamic loads, modal characteristics such as natural frequencies, participation factors and mode shapes should be known. Investigated in this study are the modal characteristics of a square tank by the finite element method. This approach can be used with subsequent dynamic analyses such as a response spectrum analysis or a harmonic analysis. Finite element models are prepared to determine the natural frequencies and mode shapes, which are easy to find the modal characteristics of a fluid-filled square tank. The effects of the fluid contained in the tank and the boundary conditions at top and bottom ends on the modal characteristics are assessed by several finite element analyses.

Comparing of the effects of scaled and real earthquake records on structural response

  • Ergun, Mustafa;Ates, Sevket
    • Earthquakes and Structures
    • /
    • v.6 no.4
    • /
    • pp.375-392
    • /
    • 2014
  • Time history analyses have been preferred commonly in earthquake engineering area to determine earthquake performances of structures in recent years. Advances in computer technology and structural analysis have led to common usage of time history analyses. Eurocode 8 allows the use of real earthquake records as an input for linear and nonlinear time history analyses of structures. However, real earthquake records with the desired characteristics sometimes may not be found, for example depending on soil classes, in this case artificial and synthetic earthquake records can be used for seismic analyses rather than real records. Selected earthquake records should be scaled to a code design spectrum to reduce record to record variability in structural responses of considered structures. So, scaling of earthquake records is one of the most important procedures of time history analyses. In this paper, four real earthquake records are scaled to Eurocode 8 design spectrums by using SESCAP (Selection and Scaling Program) based on time domain scaling method and developed by using MATLAB, GUI software, and then scaled and real earthquake records are used for linear time history analyses of a six-storied building. This building is modeled as spatial by SAP2000 software. The objectives of this study are to put basic procedures and criteria of selecting and scaling earthquake records in a nutshell, and to compare the effects of scaled earthquake records on structural response with the effects of real earthquake records on structural response in terms of record to record variability of structural response. Seismic analysis results of building show that record to record variability of structural response caused by scaled earthquake records are fewer than ones caused by real earthquake records.

Study of seismic performance of super long-span partially earth-anchored cable-stayed bridges

  • Zhang, Xin-Jun;Yu, Cong;Zhao, Jun-Jie
    • Structural Engineering and Mechanics
    • /
    • v.72 no.1
    • /
    • pp.99-111
    • /
    • 2019
  • To investigate the seismic performance of long-span partially earth-anchored cable-stayed bridge, a super long-span partially earth-anchored cable-stayed bridge scheme with main span of 1400m is taken as example, structural response of the bridge under E1 seismic action is investigated numerically by the multimode seismic response spectrum and time-history analysis, seismic behavior and also the effect of structural geometric nonlinearity on the seismic responses of super long-span partially earth-anchored cable-stayed bridges are revealed. The seismic responses are also compared to those of a fully self-anchored cable-stayed bridge with the same main span. The effects of structural parameters including the earth-anchored girder length, the girder width, the girder depth, the tower height to span ratio, the inclination of earth-anchored cables, the installation of auxiliary piers in the side spans and the connection between tower and girder on the seismic responses of partially ground-anchored cable-stayed bridges are investigated, and their reasonable values are also discussed in combination with static performance and structural stability. The results show that the horizontal seismic excitation produces significant seismic responses of the girder and tower, the seismic responses of the towers are greater than those of the girder, and thus the tower becomes the key structural member of seismic design, and more attentions should be paid to seismic design of these sections including the tower bottom, the tower and girder at the junction of tower and girder, the girder at the auxiliary piers in side spans; structural geometric nonlinearity has significant influence on the seismic responses of the bridge, and thus the nonlinear time history analysis is proposed to predict the seismic responses of super long-span partially earth-anchored cable-stayed bridges; as compared to the fully self-anchored cable-stayed bridge with the same main span, several stay cables in the side spans are changed to be earth-anchored, structural stiffness and natural frequency are both increased, the seismic responses of the towers and the longitudinal displacement of the girder are significantly reduced, structural seismic performance is improved, and therefore the partially earth-anchored cable-stayed bridge provides an ideal structural solution for super long-span cable-stayed bridges with kilometer-scale main span; under the case that the ratio of earth-anchored girder length to span is about 0.3, the wider and higher girder is employed, the tower height-to-span ratio is about 0.2, the larger inclination is set for the earth-anchored cables, 1 to 2 auxiliary piers are installed in each of the side spans and the fully floating system is employed, better overall structural performance is achieved for long-span partially earth-anchored cable-stayed bridges.

Lateral Load Distribution Factor for Pushover Analysis including Higher Mode Effects (고차모드 영향을 반영한 푸쉬오버 해석 횡력 분배계수)

  • Kim, Geon-Woo;Song, Jin-Gyu;Lee, Cheol-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.3
    • /
    • pp.203-210
    • /
    • 2006
  • A procedure for determining the lateral load pattern for pushover analysis which includes higher mode effects is presented in this study. It is well-known that the details of future earthquakes at particular site is almost impossible to predict accurately and that the code-design spectra try to represent at least the average nature of probable future earthquakes. Thus the code-design spectrum is directly used as the input earthquakes in this paper when incorporating higher mode effects in the pushover analysis so that the efforts for selecting input motions and constructing response spectrum needed in some existing method could be avoided. A case study based on the time history analysis of a irregular steel moment frame showed that the procedure proposed in this study generally outperforms various pushover analysis procedures of ATC-40 and FEMA 273. However, the proposed procedure tended to be conservative as compared with the time history analysis method.

Analysis of geotechnical Seismic Sensitivity in Kyeongju (경주 지역의 지반공학적 지진 민감도 분석)

  • 선창국
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.130-140
    • /
    • 2000
  • The earthquake hazard has been evaluated for 10km by 10km area around Kyeongju which is located near Yangsan fault and has abundant historical earthquake records. The ground motion potentials were determined based on equivalent linear analysis by using the data obtained from in situ and laboratory tests and the El centro eartqhuake record scaled to CLE and OLE of the region. The in situ tests include 9 boring investigations 2 crosshole 7 downhole 13 SASW tests and in the laboratory X-ray diffraction analyses and resonant column tests were performed. The peak ground accelerations range between 0.140g and 0.286g on CLE and between 0.051g and 0.116g on OLE respectively showing the good potential of amplification in the deep alluvial layer which is common in Kyeongju area. the response spectrum based on the Korea design guide was sometimes underestimate the motion. particularly near the natural period of the site and the importance of site-specific analysis and need for the improved site categorization method were introduced.

  • PDF

Parametric seismic evaluation of highway overpass bridges in moderate seismic areas

  • Simon, Jozsef;Vigh, Gergely L.
    • Earthquakes and Structures
    • /
    • v.12 no.3
    • /
    • pp.375-388
    • /
    • 2017
  • Prior to modern seismic provisions, several bridges were not designed for seismic actions in moderate seismic areas. Precast multi-girder and slab bridges are typical highway overpass structures; they have a significant contribution to national bridge stocks. Since the seismic behavior is questionable, a preliminary parametric study is conducted to determine critical configurations and components. The results indicate that the behavior of the abutments, backfill soil, superstructure and foundation is normally satisfactory; however, the superstructure-abutment joints are critical for both single- and multi-span bridges, while the piers are also critical for longer multi-span configurations. The parametric results provide a solid basis both for detailed seismic assessment and development of design concepts of newly built structures in moderate seismic zones.