• Title/Summary/Keyword: Analog performance

Search Result 688, Processing Time 0.036 seconds

The Performance Improvement of a Linear CCD Sensor Using an Automatic Threshold Control Algorithm for Displacement Measurement

  • Shin, Myung-Kwan;Choi, Kyo-Soon;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1417-1422
    • /
    • 2005
  • Among the sensors mainly used for displacement measurement, there are a linear CCD(Charge Coupled Device) and a PSD(Position Sensitive Detector) as a non-contact type. Their structures are different very much, which means that the signal processing of both sensors should be applied in the different ways. Most of the displacement measurement systems to get the 3-D shape profile of an object using a linear CCD are a computer-based system. It means that all of algorithms and mathematical operations are performed through a computer program to measure the displacement. However, in this paper, the developed system has microprocessor and other digital components that make the system measure the displacement of an object without a computer. The thing different from the previous system is that AVR microprocessor and FPGA(Field Programmable Gate Array) technology, and a comparator is used to play the role of an A/D(Analog to Digital) converter. Furthermore, an ATC(Automatic Threshold Control) algorithm is applied to find the highest pixel data that has the real displacement information. According to the size of the light circle incident on the surface of the CCD, the threshold value to remove the noise and useless data is changed by the operation of AVR microprocessor. The total system consists of FPGA, AVR microprocessor, and the comparator. The developed system has the improvement and shows the better performance than the system not using the ATC algorithm for displacement measurement.

  • PDF

A 1.8V 50-MS/s 10-bit 0.18-um CMOS Pipelined ADC without SHA

  • Uh, Ji-Hun;Kim, Won-Myung;Kim, Sang-Hun;Jang, Young-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.143-146
    • /
    • 2011
  • A 50-MS/s 10-bit pipelined ADC with 1.2Vpp differential input range is proposed in this paper. The designed pipelined ADC consists of eight stage of 1.5bit/stage, one stage of 2bit/stage, digital error correction block, bias & reference driver, and clock generator. 1.5bit/stage is consists of sub-ADC, DAC and gain stage, Specially, a sample-and hold amplifier (SHA) is removed in the designed pipelined ADC to reduce the hardware and power consumption. Also, the proposed bootstrapped switch improves the Linearity of the input analog switch and the dynamic performance of the total ADC. The reference voltage was driven by using the on-chip reference driver without external reference. The proposed pipelined ADC was designed by using a 0.18um 1-poly 5-metal CMOS process with 1.8V supply. The total area including the power decoupling capacitor and power consumption are $0.95mm^2$ and 60mW, respectively. Also, the simulation result shows the ENOB of 9.3-bit at the Nyquist sampling rate.

  • PDF

Performance Evaluation of Analog-digital Beamforming for Uplink Multi-User Millimeter Wave Systems (다수 사용자를 지원하는 상향링크 밀리미터 파 시스템을 위한 아날로그-디지털 빔포밍의 성능 평가)

  • Kim, Seong Hwan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 2017
  • This paper considers hybrid beamforming for millimeter wave system in uplink transmission where multiple users send their data streams simultaneously. Hybrid beamforming has low-cost and low power consumption features compared to conventional digital beamforming schemes. We assume that each user uses one transmit antenna and sends one data stream, while the base station has multiple receive antennas and multiple radio frequency chains. Therefore, hybrid beamforming is performed only at the base station. We also assume that each user does not know instantaneous channel side information (CSI), while the base station is able to estimate the CSI from all users accurately. Under this channel assumption, the outage probability is not zero. We evaluate the outage probability of the considered hybrid beamforming as a performance metric through computer simulations. We show that the outage probability of hybrid beamforming approaches that of digital beamforming in some cases.

Range-Scaled 14b 30 MS/s Pipeline-SAR Composite ADC for High-Performance CMOS Image Sensors

  • Park, Jun-Sang;Jeong, Jong-Min;An, Tai-Ji;Ahn, Gil-Cho;Lee, Seung-Hoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.1
    • /
    • pp.70-79
    • /
    • 2016
  • This paper proposes a low-power range-scaled 14b 30 MS/s pipeline-SAR composite ADC for high-performance CIS applications. The SAR ADC is employed in the first stage to alleviate a sampling-time mismatch as observed in the conventional SHA-free architecture. A range-scaling technique processes a wide input range of 3.0VP-P without thick-gate-oxide transistors under a 1.8 V supply voltage. The first- and second-stage MDACs share a single amplifier to reduce power consumption and chip area. Moreover, two separate reference voltage drivers for the first-stage SAR ADC and the remaining pipeline stages reduce a reference voltage disturbance caused by the high-speed switching noise from the SAR ADC. The measured DNL and INL of the prototype ADC in a $0.18{\mu}m$ CMOS are within 0.88 LSB and 3.28 LSB, respectively. The ADC shows a maximum SNDR of 65.4 dB and SFDR of 78.9 dB at 30 MS/s, respectively. The ADC with an active die area of $1.43mm^2$ consumes 20.5 mW at a 1.8 V supply voltage and 30 MS/s, which corresponds to a figure-of-merit (FOM) of 0.45 pJ/conversion-step.

Locker Management System using Smartphone and Arduino (스마트폰과 아두이노를 이용한 사물함 개폐 관리 시스템)

  • Lee, Seungjun;Jun, Hyunwook;An, Beongku
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.89-95
    • /
    • 2016
  • In this paper, we propose a locker system that can remotely control and manage locker. The main features of the proposed system are follows. First, connect the locker with server and then open the locker after passing through the certification process in server. Second, locker manager can more systematically manage a locker by using locker management system based on smart phone. Third, provide an instant locker for temporary using lockers to increase the ease of use. Fourth, unlike traditional analog locker, can support better security by using authentication process and log data. Performance evaluation is performed via simulation by making the dummy model. The results of performance evaluation show the proposed system can support efficiently the locker management.

Emulated Vision Tester for Automatic Functional Inspection of LCD Drive Module PCB (LCD 구동 모듈 PCB의 자동 기능 검사를 위한 Emulated Vision Tester)

  • Joo, Young-Bok;Han, Chan-Ho;Park, Kil-Houm;Huh, Kyung-Moo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.22-27
    • /
    • 2009
  • In this paper, an automatic functional inspection system EVT (Emulated Vision Tester) for LCD drive module PCB has been proposed and implemented. Typical automatic inspection system such as probing methods and vision-based systems are widely known and used, however, there exist undetectable defects due to critical timing factors which they may miss to catch from LCD equipments. Especially typical vision-based systems have inconsistency on acquisition of images so that distinction between gray scales can be difficult which results in low level of performance and reliability on the inspection results. The proposed EVT system is pure hardware solution. It directly compares pattern signals from a pattern generator to output signals from LCD drive module. It also inspects variety of analog signals such as voltage, resistance, wave forms and so forth. The EVT system not only shows high performance in terms of reliability and processing speed but reduces costs on inspection and maintenance. Also, full automation of entire production line can be realized when EVT is applied in in-line inspection processes.

Analysis of Intermodulation Distortion for Wavelength-Dependence Transmission Experiment of a Feedforward Analog Optical Transmitter with External Light Injection Method in WDM/SCM RoF Systems (WDM/SCM RoF 시스템에서 광 주입 기술을 적용한 피드포워드 아날로그 광송신기의 파장차이에 따른 상호변조 왜곡성분의 특성 분석)

  • Moon, Yon-Tae;Choi, Young-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.33-39
    • /
    • 2008
  • We have experimentally demonstrated the transmission performance of a feedforward optical transmitter using an external light injection technique. The feedforward compensation method shows 31 dB intermodulation distortion suppression and 2.2 dB noise reduction. A high side-mode suppression ratio exceeding 35 dB of the wavelength of the locked Fabry-Perot laser diode was obtained over 12 nm ranges. The suppression characteristics of the intermodulation distortion for various wavelength differences and transmission lengths were measured and analyzed as the evaluation criteria for the system performance in WDM/SCM based radio-over-fiber systems.

A natural analog study on the cover-layer performance for near-surface LILW disposal by considering the tomb of historical age (역사시대 고분을 이용한 중저준위 방사성폐기물의 천층처분 덮개성능 자연유사연구)

  • Park Jin-Beak;Park Joo Wan;Kim Chang-Lak;Yang Si Eun;Lee Sun Bok
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.279-291
    • /
    • 2005
  • To support the design concept and the performance assessment of the cover system for low- and intermediate-level radioactive waste(LILW) disposal facility, a pioneering study is conducted for the tomb of historical age. Research status of the art are investigated and the characteristics of tomb cover are summarized based on the preservation status of historical remains. On-site soil samples are prepared and their unsaturated hydraulic conductivities are measured by an one-step outflow method. Visiting the excavation site of historical tomb and communication with Korean archeological society are required for the further understanding and for the extension to the radioactive waste disposal research.

  • PDF

Implementation of the adaptive Local Sigma Filter by the luminance for reducing the Noises created by the Image Sensor (이미지 센서에 의해 발생하는 노이즈 제거를 위한 영상의 조도에 따른 적응적 로컬 시그마 필터의 구현)

  • Kim, Byung-Hyun;Kwak, Boo-Dong;Han, Hag-Yong;Kang, Bong-Soon;Lee, Gi-Dong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.3
    • /
    • pp.189-196
    • /
    • 2010
  • In this paper, we proposed the adaptive local sigma filter reducing noises generated by an image sensor. The small noises generated by the image sensor are amplified by increased an analog gain and an exposure time of the image sensor together with information. And the goal of this work was the system design that is reduce the these amplified noises. Edge data are extracted by Flatness Index Map algorithm. We made the threshold adaptively changeable by the luminance average in this algorithm that extracts the edge data not in high luminance, but just low luminance. The Local Sigma Filter performed only about the edge pixel that were extracted by Flatness Index Map algorithm. To verify the performance of the designed filter, we made the Window test program. The hardware was designed with HDL language. We verified the hardware performance of Local Sigma Filter system using FPGA Demonstration board and HD image sensor, $1280{\times}720$ image size and 30 frames per second.

The long-term Effects after Self-help Program for Fibromyalgia (섬유조직염환자를 위한 자조관리과정 지속효과에 관한 연구)

  • Han, Sang-Sook
    • Journal of muscle and joint health
    • /
    • v.9 no.2
    • /
    • pp.154-165
    • /
    • 2002
  • Purpose: The purpose of this study was to find out long-term effects of the self-help program including the stretching exercise of patient with fibromyalgia, Our findings will have the way for the nursing intervention for reduction of fibromyalgia symptoms and physical disability. Method: The research design was pre-post test design of an experimental group. 41 subjects with fibromyalgia were subjected to our study. Participants of this program were participated with a group of 8 to 12 members with duration of two and half hours for two years(March. 1998 to January. 2000). The Self-efficacy was measured by the Self-efficacy scale. Symptom was converted to scores based on visual analog scale. Physical disability was measured with questionnaires prepared by researchers of this study. Data were collected by the structured interview using questionnaires after self-help program and after 8 months. Data were analyzed by frequency, $x^2$-test and repeated t-test using SPSS 11.0 for windows. Result: Daily activities were not changed but self-described symptom was changed after 8 months. After 8 months, exercise performance along with taking drugs showed significantly lowering trend with respect to self-help program. Relieved symptom of patient with fibromyalgia has continued until 8months after 6weeks program of self-help. Also Promoted self-efficacy of patient with fibromyalgia continued after 8months. After 8 months, in self-described physical disability has showed significantly worse off than after self-help program. Conclusion: In this study, the long-term effects after self-help program for fibromyalgia have showed all symptoms and self-efficacy except exercise performance and physical disability. Therefore, it will be desirable that application of the follow up program with peer group meeting.

  • PDF