• Title/Summary/Keyword: Analog Test

Search Result 528, Processing Time 0.027 seconds

Thermal and telemetry module design for satellite camera

  • Kong, Jong-Pil;Yong, Sang-Soon;Heo, Haeng-Pal;Kim, Young-Sun;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.229-234
    • /
    • 2002
  • Under the hostile influence of the extreme space environmental conditions due to the deep space and direct solar flux, the thermal control in space applications is especially of major importance. There are tight temperature range restrictions for electro-optical elements while on the other hand there are low power consumption requirements due to the limited energy sources on the spacecraft. So, we usually have strong requirement of thermal and power control module in space applications. In this paper, the design concept of a thermal and power control module in the MSC(Multi-Spectral Camera) system which will be a payload on KOMPSATII is described in terms of H/W & S/W. This thermal and power control module, called THTM(Thermal and Telemetry Module) in MSC, resides inside the PMU(Payload Management Unit) which is responsible for the proper management of the MSC payload for controlling and monitoring the temperature insides the EOS(Electro-Optic System) and gathering all the analog telemetry from all the MSC sub-units, etc. Particularly, the designed heater controller has the special mode of "duty cycle" in addition to normal closed loop control mode as usual. THTM controls heaters in open loop according to on/off set time designed through analysis in duty cycle mode in case of all thermistor failure whereas it controls heaters by comparing the thermistor value to temperature based on closed loop in normal mode. And a designed THTM provides a checking and protection method against the failure in thermal control command using the test pulse in command itself.

  • PDF

An Analog Predistortion Linearizer using Series Feedback Structure (직렬 궤환을 이용한 아날로그 전치왜곡 선형화기)

  • Kim, Ell-Kou;Jeon, Ki-Kyung;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.3
    • /
    • pp.256-262
    • /
    • 2006
  • This paper proposes a new predistortion linearizer to compensate for AM/AM and AM/PM in the nonlinear characteristics of amplifier. This consists of common-emitter amplifier and schottky diode that is connected between emitter and ground. When effective resistance of the schottky diode with bias condition varies, common-emitter amplifier with series feedback has a increase of amplitude and expansion of phase. This makes a amplifier nonlinear characteristics are to be improved. The proposed linearizer and amplifier has been manufactured and tested to operate in cellular base station frequency (869~894MHz). The test results show that third order intermodulation distortion (IMD3) cab be removed by more than 10.4dB in case of CW 2-tone signals ${\Delta}f$=1MHz, and the adjacent channel power ratio (ACPR) also can be improved by more than 9.6dB for CDMA IS-95 1FA signals.

  • PDF

Real-time Parallel Processing Simulator for Modeling Portable Missile System and Performance Analysis (휴대용 유도탄 체계의 모델링과 성능분석을 위한 실시간 병렬처리 시뮬레이터)

  • Kim Byeong-Moon;Jung Soon-Key
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.4 s.42
    • /
    • pp.35-45
    • /
    • 2006
  • RIn this paper. we describe real-time parallel processing simulator developed for the use of performance analysis of rolling missiles. The real-time parallel processing simulator developed here consists of seeker emulator generating infrared image signal on aircraft, real-time computer, host computer, system unit, and actual equipments such as auto-pilot processor and seeker processor. Software is developed according to the design requirements of mathematic model, 6 degree-of-freedom module, aerodynamic module which are resided in real-time computer. and graphic user interface program resided in host computer. The real-time computer consists of six TI C-40 processors connected in parallel. The seeker emulator is designed by using analog circuits coupled with mechanical equipments. The system unit provides interface function to match impedance between the components and processes very small electrical signals. Also real launch unit of missiles is interfaced to simulator through system unit. In order to use the real-time parallel processing simulator developed here as a performance analysis equipment for rolling missiles, we perform verification test through experimental results in the field.

  • PDF

Development of Ground-Based Search-Coil Magnetometer for Near-Earth Space Research

  • Shin, Jehyuck;Kim, Khan-Hyuk;Jin, Ho;Kim, Hyomin;Kwon, Jong-Woo;Lee, Seungah;Lee, Jung-Kyu;Lee, Seongwhan;Jee, Geonhwa;Lessard, Marc R.
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.509-515
    • /
    • 2016
  • We report on development of a ground-based bi-axial Search-Coil Magnetometer (SCM) designed to measure time-varying magnetic fields associated with magnetosphere-ionosphere coupling processes. The instrument provides two-axis magnetic field wave vector data in the Ultra Low Frequency or ULF (1 mHz to 5 Hz) range. ULF waves are well known to play an important role in energy transport and loss in geospace. The SCM will primarily be used to observe generation and propagation of the subclass of ULF waves. The analog signals produced by the search-coil magnetic sensors are amplified and filtered over a specified frequency range via electronics. Data acquisition system digitizes data at 10 samples/s rate with 16-bit resolution. Test results show that the resolution of the magnetometer reaches $0.1pT/{\sqrt{Hz}}$ at 1 Hz, and demonstrate its satisfactory performance, detecting geomagnetic pulsations. This instrument is scheduled to be installed at the Korean Antarctic station, Jang Bogo, in the austral summer 2016-2017.

A real-time sorting algorithm for in-beam PET of heavy-ion cancer therapy device

  • Ke, Lingyun;Yan, Junwei;Chen, Jinda;Wang, Changxin;Zhang, Xiuling;Du, Chengming;Hu, Minchi;Yang, Zuoqiao;Xu, Jiapeng;Qian, Yi;She, Qianshun;Yang, Haibo;Zhao, Hongyun;Pu, Tianlei;Pei, Changxu;Su, Hong;Kong, Jie
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3406-3412
    • /
    • 2021
  • A real-time digital time-stamp sorting algorithm used in the In-Beam positron emission tomography (In-Beam PET) is presented. The algorithm is operated in the field programmable gate array (FPGA) and a small amount of registers, MUX and memory cells are used. It is developed for sorting the data of annihilation event from front-end circuits, so as to identify the coincidence events efficiently in a large amount of data. In the In-Beam PET, each annihilation event is detected by the detector array and digitized by the analog to digital converter (ADC) in Data Acquisition Unit (DAQU), with a resolution of 14 bits and sampling rate of 50 MS/s. Test and preliminary operation have been implemented, it can perform a sorting operation under the event count rate up to 1 MHz per channel, and support four channels in total, count rate up to 4 MHz. The performance of this algorithm has been verified by pulse generator and 22Na radiation source, which can sort the events with chaotic order into chronological order completely. The application of this algorithm provides not only an efficient solution for selection of coincidence events, but also a design of electronic circuit with a small-scale structure.

Correlation Analysis between Lumbar Instability Test Positive Response Number and Breathing Pattern Change Rate and Pain in Young Peoples with Chronic Low Back Pain (젊은 만성허리통증자의 허리부위 불안정성 검사 양성반응 수와 호흡패턴변화율, 통증 간의 상관관계분석)

  • Ki, Chul;Nam, Ki-Won
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.14 no.3
    • /
    • pp.73-80
    • /
    • 2019
  • PURPOSE: This study examined the correlation between the visual analog scale (VAS) and the rate of change in the respiration patterns according to the result of Lumbar Instability Tests (LITs) in young people with chronic low back pain (CLBP) METHODS: Thirty-six adults, aged 20-40 years with CLBP, participated in this study. The general characteristics and VAS of the participants were recorded by the subjects themselves and seven structure and functional LITs were conducted. According to the positive response number, the positive group was divided into four groups (group 1: n=8, group 2: n=9, group 3: n=10, group 4: n=9). The breathing pattern change tests were performed in three states: during forced breathing exercise and motor control tests. A total of 13 positive lists were set, each of which was scored by 1 or 2 points according to the severity. After the positive lists were scored, the breathing pattern changing rate (BPCR) and VAS were compared according to the positive response number of LITs, and the correlation between them was analyzed. RESULTS: A strong correlation was observed between the number of positive of LITs and BPCR (r= .863, p= .000) and a moderate correlation between the positive number of LITs and VAS (r= .508, p= .002). In addition, there was a poor correlation between the BPCR and VAS (r= .434, p= .008). CONCLUSION: In young CLBP people, when the structural and functional instability are both present, the changes in the respiratory pattern of the whole body can be varied and broader, and the pain scale also increases.

Effects of Ultrasound, Laser and Exercises on Temporomandibular Joint Pain and Trismus Following Head and Neck Cancer

  • Elgohary, Hany Mohamed;Eladl, Hadaya Mosaad;Soliman, Ashraf Hassan;Soliman, Elsadat Saad
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.846-853
    • /
    • 2018
  • Objective To compare the effects of low intensity ultrasound (LIUS), traditional exercise therapy (TET), low level laser therapy (LLLT) and TET on temporomandibular joint (TMJ) pain and trismus following recovery from head and neck cancer (HNC). Methods Sixty participants following, who had experienced HNC, were randomly allocated to three groups of 20 people each. Each group received different therapy. Group A received LIUS and TET; group B received LLLT and TET; while group C received TET. All 60 participants were evaluated under the visual analog scale (VAS), the University of Washington Quality of Life questionnaire (UW-QOL) and the Vernier caliper scale (VCS) at the beginning of the therapies and after 4 weeks. Results ANOVA test revealed significant improvements across all three groups with outcomes of p<0.05. The results of the UW-QOL questionnaire showed a significant difference between groups A, B and C in favor of group A (p<0.05). The VAS results showed a more improvement in group A as compared to group B (p<0.05), while there was no statistical difference between groups B and C (p>0.05). The VCS results showed more improvement for the individuals in group B as compared to those in group C (p<0.05), while there was minimal difference between groups A and B (p>0.05). Conclusion The LIUS and TET are more effective than LLLT and/or TET in reducing TMJ pain and trismus following HNC.

An Overview of Korean Medicine Research for Pompholyx - Literature Review based on recently published studies in Korea - (한포진에 대한 최근 한의학적 연구 동향 - 국내 학술지를 중심으로 -)

  • Jeong, Jong Min;Oh, Yong Taek;Kim, Kyeong Han;Lee, Myoung sun;Song, Beom Yong;Kim, Jong Uk;Yook, Tae-han
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.61-72
    • /
    • 2018
  • Objectives : This study was conducted to review the research trends in Korean Medicine of pompholyx based on publications in Korea. Methods : Literature published after 2000 were collected using OASIS, NDSL, KISS, and key words searched were "한포진" "발한이상" "pompholyx" "dyshidrotic eczema". Results : 10 case reports and 4 patient studies were selected for study. Conclusions : Korean medicine treatments included acupuncture, pharmacopuncture, venesection therapy, herbal medicine, ointments and carbon arc lamp therapy. The most commonly used diagnostic method for pompholyx was inspection along with pulse diagnosis, abdominal diagnosis, tongue diagnosis, culture test, and KOH smear screening. The most frequently used treatment evaluation method was Likert scale while VAS(Visual Analog Scale) and Visual&Subjective symptoms were each used in 4 studies. Among 29 patients in 14 papers who showed clinical manifestations of pompholyx, there were 15 male patients (52%), 14 female patients (48%), and the male to female ratio showed 1.07:1. Symptoms were improved using Korean Medicine treatments including acupuncture and herbal medicine. Concurrent treatment using special treatments such as pharmacopuncture, jiyang-go, bojungikgi-tang(ex), external applications showed higher treatment effects. Korean medical treatment of pompholyx was effective in all studies, but the lack of numbers of research on Korean medicine of pompholyx was witnessed compared to other diseases such as psoriasis. Also considering the number of patients suffering from pompholyx, further studies should be conducted.

An in vivo study comparing efficacy of 0.25% and 0.5% bupivacaine in infraorbital nerve block for postoperative analgesia

  • Saha, Aditi;Shah, Sonal;Waknis, Pushkar;Aher, Sharvika;Bhujbal, Prathamesh;Vaswani, Vibha
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.4
    • /
    • pp.209-215
    • /
    • 2019
  • Background: Pain is an unpleasant sensation ranging from mild localized discomfort to agony and is one of the most commonly experienced symptoms in oral surgery. Usually, local anesthetic agents and analgesics are used for pain control in oral surgical procedures. Local anesthetic agents including lignocaine and bupivacaine are routinely used in varying concentrations. The present study was designed to evaluate and compare the efficacy of 0.25% and 0.5% bupivacaine for postoperative analgesia in infraorbital nerve block. Methods: Forty-one patients undergoing bilateral maxillary orthodontic extraction received 0.5% bupivacaine (n = 41) on one side and 0.25% bupivacaine (n = 41) on the other side at an interval of 7 d. The parameters evaluated for both the bupivacaine concentrations were onset of action, pain during procedure (visual analog scale score [VAS]), and duration of action. The results were noted, tabulated, and analyzed using the Wilcoxon signed rank test. Results: The onset of action of 0.5% bupivacaine was quicker than that of 0.25% bupivacaine, but the difference was not statistically significant (P = 0.306). No significant difference was found between the solutions for VAS scores (P = 0.221) scores and duration of action (P = 0.662). Conclusion: There was no significant difference between 0.25% bupivacaine and 0.5% bupivacaine in terms of onset of action, pain during procedure, and duration of action. The use of 0.25% bupivacaine is recommended.

A Design of Receiver Modem That Can Be Applied to Real-Time Target Change Guided Weapon (실시간 목표물 변경 유도무기에 적용 가능한 수신 모뎀 설계)

  • Maeng, Sung-jae;Lee, Jong-hyuk;Kim, Kang-san
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.97-103
    • /
    • 2019
  • In this paper, we designed and fabricated a receiving modem that can be applied to guided weapons can change real-time targets with little effect of fading. The designed modem consists of synchronous detector, timing error estimator, timing recovery, differential decoder and viterbi decoder, and it's implemented in FPGA so that it can be redesigned and modified according to requirements. The modem board was directly converted from IF frequency to baseband and converted into digital data through ADC. It is confirmed that it is applicable to the guided weapons that changing real-time targets through simulations, measurements and test.