• Title/Summary/Keyword: Analog Test

Search Result 534, Processing Time 0.028 seconds

An Audio Comparison Technique for Verifying Flash Memories Mounted on MP3 Devices (MP3 장치용 플래시 메모리의 오류 검출을 위한 음원 비교 기법)

  • Kim, Kwang-Jung;Park, Chang-Hyeon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.5
    • /
    • pp.41-49
    • /
    • 2010
  • Being popularized the use of portable entertainment/information devices, the demand on flash memory has been also increased radically. In general, flash memory reveals various error patterns by the devices it is mounted, and thus the memory makers are trying to minimize error ratio in the final process through not only the electric test but also the data integrity test under the same condition as real application devices. This process is called an application-level memory test. Though currently various flash memory testing devices have been used in the production lines, most of the works related to memory test depend on the sensual abilities of human testers. In case of testing the flash memory for MP3 devices, the human testers are checking if the memory has some errors by hearing the audio played on the memory testing device. The memory testing process like this has become a bottleneck in the flash memory production line. In this paper, we propose an audio comparison technique to support the efficient flash memory test for MP3 devices. The technique proposed in this paper compares the variance change rate between the source binary file and the decoded analog signal and checks automatically if the memory errors are occurred or not.

A Clinical Study of Carthmi-Flos Herbal Acupuncture Treatment on Cervical Disc Herniation Patients (경추추간판(頸椎椎間板) 탈출증(脫出症) 환자(患者)의 홍화약침치료(紅花藥鍼治療)에 대한 임상적(臨床的) 고찰(考察))

  • Yeom, Seung-Chul;Kim, Do-Ho;Ryu, Sung-Won;Kim, Dae-Joong;Cho, Nam-Geun;Yun, Ju-Young;Lee, Geon-Mok
    • Journal of Acupuncture Research
    • /
    • v.23 no.3
    • /
    • pp.21-35
    • /
    • 2006
  • Objectives : Herniation of Nucleus Pulposus(HNP) of Cervical is the most important reason that causes Cervical pain. The aim of this study is to investigate the effectiveness of Carthmi-Flos Herbal acua-acupuncture therapy for Cervical disc Herniation patients. Methods : To evaluate the effectiveness of Carthmi-Flos Herbal acua-Acupuncture Therapy, 20 patients were treated by Carthmi-Flos Herbal acua-acupuncture therapy. To estimate the efficacy of treatment, we used Quardruple Visual Analog Scale (QVAS). Results & Conclusion : 1. As a objectivity treatment record, they test treatment record good 35%, fair 35%, excellent 30%. 2. After Carthmi-Flos acua-acupuncture therapy, pain rate changed from 8.80 to 5.40 3. By the results which puts out the statistics in sex , a pain rate of male changed from 8.57$({\pm}1.51)$ to 2.71$({\pm}2.63)$, a pain rate of female 8.92$({\pm}0.95)$ to 3.77$({\pm}2.09)$. Intentional difference is none as a therapy. 4. By the results which puts out the statistics in age, after forties changed from 9.07$({\pm}0.88)$ to 3.80$({\pm}2.43)$ and before forties changed from 8.00$({\pm}1.58)$ to 2.20$({\pm}1.30)$. Intentional difference is none as a therapy. 5. By the results which puts out the statistics in Duration, pain rate of the acutest group changed from 8.36$({\pm}1.12)$ to 2.18$({\pm}1.08)$, pain rate of the subacute group changed from 9.80$({\pm}0.45)$, to 5.20$({\pm}2.68)$, pain rate of the chronic group changed from 8.67$({\pm}1.53)$ to 3.33$({\pm}1.53)$. Intentional difference is none as a therapy. 6. By the results which puts out the statistics in the reading of Lumbar MID, pain rate of the Bulging type changed from 9.00$({\pm}1.05)$ to 4.30$({\pm}2.67)$, pain rate of the Protruded type changed from 8.50$({\pm}1.00)$, to 3.50$({\pm}1.29)$, pain rate of the Extruded type changed from 6.00 to 1.00, pain rate of the Mixed type changed from 9.20$({\pm}0.84)$ to 2.00$({\pm}1.23)$, Intentional difference is none as a therapy.

  • PDF

Practicability Assessment of Spherical Mechanical Check Device(SMCD) (Mechanical Check용 Spherical device의 제작 및 특성 평가)

  • Lee, Byung-Koo;Yang, Dae-Sik;Kweon, Young-Ho;Ko, Shin-Gwan;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Digital medical image commenced with an introduction of PACS has become more popular today in the radiation diagnosis and radiation treatment and made great progress, in particular, for medical testing field, whereas it has made slow progress for radiation treatment field. In order to accommodate the current trend of digital from analog, a spherical mechanical check device(SMCD) that is the form of spherical differing from the existing form of flat or cube has been designed and tested its practicability to replace the part in mechanical check with digital image from QA operation. If the distance maintains constance between source(target) and image detector with constant distance to the center of spherical mechanical check device(SMCD), the size will be shown as a constant image at all times regardless of its direction exposed. For the test, two accurate hemispheres are made and put together which results in a sphere of the equilateral circle. It enables a variety of implementation of the existing mechanical check using digital image as follows: congruity level of radiation field and light field, size accuracy of radiation field and collimation field, gantry rotation isocenter check, collimation rotation isocenter check, room laser accuracy check, collimation rotation angle check, couch rotation angle check, and more. In addition, it has proved its practicability in checking isocenter congruity level as real time at the time of simultaneous rotation between gantry and couch that is applied to the non-coplanar field, which had been hard to apply as a device formed of existing flat or cube.

  • PDF

A Clinical study of Bee-venom acupuncture treatment on protrusion disc Patients (봉약침(蜂藥鍼)을 위주로 한 요추추간판탈출증(腰椎椎間板脫出症)의 돌출형(突出型) 환자(患者)(protrusion disc patients)에 대한 임상적(臨床的) 고찰(考察))

  • Lee, Geon-mok;Lee, Kil-soong;Yeom, Seong-chul;Jang, Jae-ho;Yun, Ju-young;Hwang, Byung-chun;Kug, Yu-suk;Jang, Ji-yeon;Choi, Jeong-seon;Kim, Yang-jung;Park, Jong-un;Cho, Nam-geun
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.13-25
    • /
    • 2004
  • Objective : Herniation of Nucleus Pulpous(HNP) of Lumbar is the most important reason that causes low back pain. The aim of this study is to investigate the effectiveness of Bee-venom acua-acupuncture therapy for protrusion disc patients. Methods : To evaluate the effectiveness of Bee-Venom Acupuncture Therapy, 20 patients were treated by bee-venom acua-acupuncture therapy. To estimate the efficacy of treatment, we used Quardruple Visual Analog Scale(QVAS). Results : 1. As a objectivity treatment record, they test treatment record good 60%, fair 25%, excellent 15%. 2. After bee-venom therapy, pain rate changed from 8.25 to 2.15. 3. By the results which puts out the statistics in sex, a pain rate of male changed from 8.75 to 2.50, a pain rate of female 7.92 to 1.92. Intentional difference is none as a therapy. By the results which puts out the statistics in age, after forties changed from 7.78 to 2.22 and before forties changed from 7.90 to 1.92. By the results which puts out the statistics in disc herniation, pain rate of central type changed from 8.29 to 2.29, pain rate of left type changed from 8.20 to 1.40, pain rate of Right type changed from 8.00 to 4.00.

  • PDF

Research on Broadband Signal Processing Techniques for the Small Millimeter Wave Tracking Radar (소형 밀리미터파 추적 레이더를 위한 광대역 신호처리 기술 연구)

  • Choi, Jinkyu;Na, Kyoung-Il;Shin, Youngcheol;Hong, Soonil;Park, Changhyun;Kim, Younjin;Kim, Hongrak;Joo, Jihan;Kim, Sosu
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.49-55
    • /
    • 2021
  • Recently, a small tracking radar requires the development of a small millimeter wave tracking radar having a high range resolution that can acquire and track a target in various environments and disable the target system with a single blow. Small millimeter wave tracking radar with high range resolution needs to implement a signal processor that can process wide bandwidth signals in real time and meet the requirements of small tracking radar. In this paper, we designed a signal processor that can perform the role and function of a signal processor for a small millimeter wave tracking radar. The signal processor for the small millimeter wave tracking radar requires the real-time processing of input signal of OOOMHz center frequency and OOOMHz bandwidth from 8 channels. In order to satisfy the requirements of the signal processor, the signal processor was designed by applying the high-performance FPGA (Field Programmable Gate Array) and ADC (Analog-to-digital converter) for pre-processing operations, such as DDC (Digital Down Converter) and FFT (Fast Fourier Transform). Finally, the signal processor of the small millimeter wave tracking radar was verified via performance test.

The Usefulness of a Wearable Device in Daily Physical Activity Monitoring for the Hospitalized Patients Undergoing Lumbar Surgery

  • Kim, Dong Hwan;Nam, Kyoung Hyup;Choi, Byung Kwan;Han, In Ho;Jeon, Tae Jin;Park, Se Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.5
    • /
    • pp.561-566
    • /
    • 2019
  • Objective : Functional outcomes have traditionally been evaluated and compared using subjective surveys, such as visual analog scores (VAS), the Oswestry disability index (ODI), and Short Form-36 (SF-36), to assess symptoms and quality of life. However, these surveys are limited by their subjective natures and inherent bias caused by differences in patient perceptions of symptoms. The Fitbit $Charge^{(R)}$ (Fitbit Inc., San Francisco, CA, USA) provides accurate and objective measures of physical activity. The use of this device in patients after laminectomy would provide objective physical measures that define ambulatory function, activity level, and degree of recovery. Therefore, the present study was conducted to identify relationships between the number of steps taken by patients per day and VAS pain scores, prognoses, and postoperative functional outcomes. Methods : We prospectively investigated 22 consecutive patients that underwent laminectomy for spinal stenosis or a herniated lumbar disc between June 2015 and April 2016 by the same surgeon. When patients were admitted for surgery and first visited after surgery, preoperative and postoperative functional scores were recorded using VAS scores, ODI scores, and SF-36. The VAS scores and physical activities were recorded daily from postoperative day (POD) 1 to POD 7. The relationship between daily VAS scores and daily physical activities were investigated by simple correlation analysis and the relationship between mean number of steps taken and ODI scores after surgery was subjected to simple regression analysis. In addition, Wilcoxon's signed-rank test was used to investigate the significance of pre-to-postoperative differences in VAS, ODI, and SF-36 scores. Results : Pre-to-postoperative VAS (p<0.001), ODI (p<0.001), SF-36 mental composite scores (p=0.009), and SF-36 physical composite scores (p<0.001) scores were found to be significantly different. Numbers of steps taken from POD 1 to POD 7 were negatively correlated with daily VAS scores (r=-0.981, p<0.001). In addition, the mean number of steps from POD 3 to POD 7 and the decrease in ODI conducted one month after surgery were statistically significant (p=0.029). Conclusion : Wearable devices are not only being used increasingly by consumers as lifestyle devices, but are also progressively being used in the medical area. This is the first study to demonstrate the usefulness of a wearable device for checking patient physical activity and predicting pain and prognosis after laminectomy. Based on our experience, the wearable device used to provide measures of physical activity in the present study has the potential to provide objective information on pain severity and prognosis.

A Pilot Study to Evaluate the Reliability of Pattern Identification Tool for Knee Osteoarthritis and to Analyze Correlation between Pattern Identification Tool and Knee Range of Motion, Visual Analog Scale and Western Ontario & Mcmaster Universities Osteoarthritis Index (퇴행성 무릎관절염 변증도구의 신뢰도 평가 및 무릎 ROM, VAS, WOMAC과의 상관관계에 대한 탐색적 연구)

  • Oh, Seung-Joon;Jang, Eunsu;Oh, Young-Seon;Kang, Wee-chang;Lee, Eun-Jung;Jung, In Chul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.29 no.3
    • /
    • pp.113-128
    • /
    • 2019
  • Objectives To evaluate the pattern identification tool for knee osteoarthritis and to investigate the relationship between pattern identification tool and knee ROM (range of motion), VAS (visual analog scale) and WOMAC (Western Ontario & McMaster Universities osteoarthritis index). Methods We studied 50 patients who are diagnosed as degenerative osteoarthritis. With one patient dropping out, total of 49 patient went through pattern identification tool. Re-test of the pattern identification tool was implemented after about a week. The reliability was analyzed by calculating ICC (intraclass correlation coefficient). Also, reliability of each pattern identification score was calculated along with influence factor and correlation between knee ROM, VAS and WOMAC. Results Reliability of the pattern identification tool was evaluated as 'poor agreement beyond chance' with ICC value of 0.396. Reliablility of each pattern identification score was calculated and four out of five were measured 'good' with one 'moderate' reliability. Two of inter-item consistency were 'good', two were 'acceptable' and one was 'questionable'. Correlation between each pattern identification and knee ROM showed 'clear negative linear relationship' with two patterns. VAS showed 'clear positivie linear relationship' with all five patterns. WOMAC showed 'positivie linear relationship' with all five patterns. Conclusions According to the results, pattern identification tool for knee osteoarthritis seems to have meaningful relationship with other agnedas. Also, further research is needed to develop the tool.

Development of DCPT Equipment based on IoT for Rod Tamping in Smart Construction (스마트건설 토공사 다짐 측정을 위한 IoT 기반의 DCPT 기술개발)

  • Park, Hong-Gi;Bae, Kyoung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.501-509
    • /
    • 2020
  • Earthwork in the construction field is a core process of construction, and it is used in almost all processes and is connected to the safety of the structure directly. Therefore, it is essential to analyze and confirm the road tamping through a plate bearing test and a field density test. The current analog measurement methods for road tamping measurement is difficult to check in real-time, accurate location information, time information, and the history management of workers in the field. Therefore, IoT (Internet of Things)-based DCPT (Dynamic Cone Penetration Test) was developed for a smart construction environment with a solution to the problem. The Smart DCPT system operated in a smartphone environment is IoT-based. The Smart DCPT system can apply various applications and has advantages of flexibility, low cost, and high efficiency. The IoT-based DCPT records the digital road tamping information, location information, time information, and worker information per measurement count. In addition, the various information is transmitted in real-time to the management center through a smartphone. This system is expected to contribute to the management of the construction process.

Psychosomatic Symptoms of Rotating Shift and Daytime Working Nurses in a General Hospital (일 병원의 순환교대근무와 주간고정근무 여성 간호사의 근무형태에 따른 정신신체 증상)

  • Kim, Byoung-Jo;Choi, Mal-Rye;Kim, Tae-Hyung;Kim, Hyeong-Wook;Eun, Hun-Jeong
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.22 no.2
    • /
    • pp.79-86
    • /
    • 2014
  • Objectives : Shift work disorder occurs when you have difficulties adjusting to a work schedule that takes place during a time which most people sleep. Some people may have diverse psychosomatic symptoms, such as sleep problems, depression, anxiety, and headaches even after the shift work schedule ends. The aims of this study are to compare difference of psychosomatic symptoms between rotating shift and daytime working nurse groups. Methods : Volunteer nurses working in a general hospital were recruited in a general hospital. We collected sociodemographic data. We used questionnaires for headache type, headache frequency, and VAS(Visual Analog Scale) for headache intensity, BDI(Beck depression Inventory) and GSAQ(Global Sleep Assessment Questionnaire). We used Mann-Whitney test and Chi-square test for hypothesis testing. Results : Data collected from 84 women nurses. Rotating shift(N=37) working nurses showed younger, more unmarried, and shorter work periods than daytime working nurses (N=47). Also rotating shift group showed more problems of headache, insomnia, excessive daytime sleepiness, depression and anxiety than daytime group. The above results were statistically significant. Conclusions : The rotating shift work women nurses produced more headache, insomnia, excessive daytime sleepiness, depression, and anxiety than daytime working ones.

  • PDF

Intravenous caffeine citrate vs. magnesium sulfate for reducing pain in patients with acute migraine headache; a prospective quasi-experimental study

  • Baratloo, Alireza;Mirbaha, Sahar;Kasmaei, Hossein Delavar;Payandemehr, Pooya;Elmaraezy, Ahmed;Negida, Ahmed
    • The Korean Journal of Pain
    • /
    • v.30 no.3
    • /
    • pp.176-182
    • /
    • 2017
  • Background: Current evidence suggests that intravenous magnesium sulfate might be effective for reducing migraine pain. In a recent pilot study, we showed that intravenous caffeine citrate could reduce the severity of migraine headache. The objective of this study is to investigate the efficacy of intravenous caffeine citrate vs. magnesium sulfate for management of acute migraine headache. Methods: We conducted a prospective quasi-experimental study from January until May 2016 in two educational medical centers of Shahid Beheshti University of Medical Sciences (Shoahadaye Tajrish Hospital and Imam Hossein Hospital), Tehran, Iran. The study included patients who were referred to the emergency department and met the migraine diagnosis criteria of the International Headache Society. Patients were allocated into 2 groups receiving either 60 mg intravenous caffeine or 2 g intravenous magnesium sulfate. The pain scores, based on the visual analog scale, were recorded on admission, as well as one and two hours after receiving the drug. A Chi-Square test and student t-test were used for analysis of baseline characteristics. A Mann-Whitney U test and Wilcoxon singed rank test were used to analyze differences in the visual analogue scale (VAS) score between and within the groups respectively. Results: In total, 70 patients (35 patients in each group) with the mean age of $33.1{\pm}11.3years$ were included (64.3% female). For the Caffeine citrate group, the median pain score decreased from 9.0 (2.0) to 5.0 (4.0) after one hour and to 3.0 (4.0) after two hours. For the magnesium sulfate group, the pain score decreased from 8.0 (2.0) to 2.0 (2.0) after one hour and to 0.0 (1.0) after two hours. Both intravenous caffeine citrate and intravenous magnesium sulfate reduced pain scores significantly but the magnesium sulfate group showed more improvement than the Caffeine citrate group after one hour (P < 0.001) and after two hours (P < 0.001). Conclusions: It is likely that both intravenous caffeine and intravenous magnesium sulfate can reduce the severity of migraine headache. Moreover, intravenous magnesium sulfate at a dose of 2 g might be superior to intravenous caffeine citrate 60 mg for the short term management of migraine headache in emergency departments.