• 제목/요약/키워드: Analog Test

Search Result 532, Processing Time 0.029 seconds

NDT Determination of Cement Mortar Compressive Strength Using SASW Technique

  • Cho, Young-Sang
    • KCI Concrete Journal
    • /
    • v.13 no.2
    • /
    • pp.10-18
    • /
    • 2001
  • The spectral analysis of surface waves (SASW) method, which is an in-situ seismic technique, has mainly been developed and used for many years to determine the stiffness profile of layered media (such as asphalt concrete and layered soils) in an infinite half-space. This paper presents a modified experimental technique for nondestructive evaluation of in-place cement mortar compressive strength in single-layer concrete slabs of rather a finite thickness through a correlation to surface wave velocity. This correlation can be used in the quality control of early age cement mortar structures and in evaluating the integrity of structural members where the infinite half space condition is not met. In the proposed SASW field test, the surface of the structural members is subjected to an impact, using a 12 mm steel ball, to generate surface wave energy at various frequencies. Two accelerometer receivers detect the energy transmitted through the medium. By digitizing the analog receiver outputs, and recording the signals for spectral analysis, surface wave velocities can be identified. Modifications to the SASW method includes the reduction of boundary reflections as adopted on the surface waves before the point where the reflected compression waves reach the receivers. In this study, the correlation between the surface wave velocity and the compressive strength of cement mortar is developed using one 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slab of 2,000 psi (140 kgf/$\textrm{cm}^2$) and two 36"x36"x4"(91.44$\times$91.44$\times$91.44 cm) cement mortar slabs of 3,000 psi (210 kgf/$\textrm{cm}^2$).

  • PDF

A Study on the Effects of I&C Systems by EMI Generating from Corona Discharge at Transformer Area (변압기 지역 코로나 전자파 간섭에 의한 계측제어설비 영향에 관한 연구)

  • Min, Moon-Gi;Lee, Jae-Ki;Park, Jin-Yeub;Kim, Hee-Je
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.266-271
    • /
    • 2014
  • The Electromagnetic Interference(EMI) generating from corona discharge of transformer area can interference the digital Instrument and Control(I&C) systems located nearby transformers. When the potential gradient of the electric field around the conductor is high enough to form a conductive region but not high enough to cause electrical breakdown to nearby objects, the EMI of corona discharge emits with the conducted and radiated noise and it interferences the signals of the I&C systems. Since digital I&C systems have an efficiency and competitive price, the analog I&C systems have been upgraded and displaced with the digital I&C systems but which have less EMI Immunity. There was no assessment to I&C systems by EMI generating corona discharge nearby transformers. When the safety-related I&C systems are installed in plants, the verification of equipment EMI should be done not in site-specific test but in test facilities. There are the need to do the site-specific EMI evaluation of corona discharge nearby transformers. This paper assesses the margin between plant emission limits and the highest composite plant emission of corona. When the non safety-related I&C systems are placed in transformer area, it suggests the appropriate radiated susceptibility level to EMI of corona discharge.

Chia seed (Salvia Hispanica L.) added yogurt reduces short-term food intake and increases satiety: randomised controlled trial

  • Ayaz, Aylin;Akyol, Asli;Inan-Eroglu, Elif;Cetin, Arzu Kabasakal;Samur, Gulhan;Akbiyik, Filiz
    • Nutrition Research and Practice
    • /
    • v.11 no.5
    • /
    • pp.412-418
    • /
    • 2017
  • BACKGROUND/OBJECTIVE: Several studies have reported that consumption of Salvia Hispanica L.,commonly known as chia seed, may exert beneficial effects on health outcomes. The main purpose of this study was to examine the influence of chia seed consumption as a mid-morning snack on short-term satiety. SUBJECTS/METHODS: Subjects (n = 24) were tested using a randomized, cross-over design consisting of three mid-morning snacks. Yogurt with no chia seed, yogurt with 7 g chia seed, and yogurt with 14 g chia seed were given to subjects on different test days. After subjects were asked to report visual analog scale (VAS) scores on sensory outcomes, ad libitum lunch was served, and energy intake of individuals was measured. RESULTS: VAS scores indicated that participants reported significantly lower scores for hunger (P = 0.033), prospective food consumption (P = 0.031), amounts of food that could be consumed (P = 0.017), desire for sugary foods (P = 0.015), and higher scores for satiety (P = 0.031) on the test days with 7 g and 14 g chia seed. Energy intake of individuals during ad libitum lunch was significantly lower when they consumed yogurt with 7 g or 14 g chia seed (P = 0.037). CONCLUSIONS: The study demonstrated that chia seed consumption as a mid-morning snack may induce short-term satiety in healthy individuals.

Design of an eFuse OTP Memory of 8bits Based on a Generic Process ($0.18{\mu}m$ Generic 공정 기반의 8비트 eFuse OTP Memory 설계)

  • Jang, Ji-Hye;Kim, Kwang-Il;Jeon, Hwang-Gon;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.687-691
    • /
    • 2011
  • In this paper, we design an 8-bit eSuse OTP (one-time programmable) memory in consideration of EM (electro-migration) and eFuse resistance variation based on a $0.18{\mu}m$ generic process, which is used for an analog trimming application. First, we use an external program voltage to increase the program power applied an eFuse. Secondly, we apply a scheme of precharging BL to VSS prior to RWL (read word line) activation and optimize read NMOS transistors to reduce the read current flowing through a non-programmed cell. Thirdly, we design a sensing margin test circuit with a variable pull-up load out of consideration for the eFuse resistance variation of a programmed eFuse. Finally, we increase program yield of eFuse OTP memory by splitting the length of an eFuse link.

  • PDF

Usefulness of Morphine in the Periarticular Multimodal Drug Local Injection after Surgery for Hallux Valgus (무지 외반증 수술에서 관절 주위 다중 약물 국소 투여 시 Morphine의 유용성)

  • Cho, Jae Ho;Choi, Hong Joon;Kim, Yu Mi;Kim, Jae Young;Wang, Bae Gun;Lee, Woo Chun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • Purpose: Proximal metatarsal chevron osteotomy for hallux valgus is followed by significant amount of postoperative pain. Periarticular multimodal drug local injection can be an option for pain control. This study was attempted to evaluate the efficacy of the morphine as multimodal drug and to confirm the effect of periarticular multimodal drug local injection on controlling early postoperative pain. Materials and Methods: Between March 2012 and June 2012, 22 patients received proximal metatarsal chevron osteotomy for the correction of hallux valgus deformity. 10 patients (Group A) received periarticular injection of the test solution made with morphine, ropivacaine, ephinephrine and ketorolac. 12 patients (Group B) received periarticular injection of the test solution without morphine. The visual analog scale (VAS) was checked at 2, 4, 6, 8 hours, 1 day and 2 days each after surgery. Results: The VAS score at postoperative 2 hours to 1 day between two groups showed no significant difference, but the VAS score at postoperative 2 days was significantly higher in Group A compared to the VAS score of group B. The amount of additional pain control (tramadol HCL) between two groups showed no significant difference for 3 days after surgery. Conclusion: Periarticular multimodal drug local injection was effective in reducing pain after hallux valgus surgery regardless of mixing with morphine.

The Effect of Lumbar Stabilization Exercise and The Neurodynamic Technique on Patients with Low Back Pain and Lumbar Instability (요추부 불안정성을 가진 요통환자에게 요부안정화운동과 신경가동술의 치료적 효과)

  • Jeong, Eui-Young;Kim, Suhn-Yeop
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.4
    • /
    • pp.115-125
    • /
    • 2016
  • PURPOSE: This study aimed to compare the effects of lumbar stabilization exercise with those of the neurodynamic technique on low back pain in patients with lumbar instability. METHODS: The subjects included those with more than three tests with positive results for lumbar instability and those with a positive sign during the neurodynamic test, all of whom had low back pain. For the lumbar stabilization exercise group (n=15), lumbar stabilization exercise was performed using a sling system, while the neurodynamic technique group (n=15) performed the neurodynamic technique. The intervention was performed 5 days a week for 4 weeks. All measurement of each subject were measure at pre-intervention and post-intervention (after 4 weeks). SPSS/PC ver. 18.0 program was used to compile results. RESULTS: There was no significant difference in general characteristics of subjects between both groups (p>.05). Assessed items included the visual analog scale score (VAS), Korean version of the Oswestry Disability Index (KODI), lumbar instability test positive response counter (LIC) and Fear-Avoidance Beliefs Questionnaire score (FABQ), and a significant reduction was observed post-intervention compared to pre-intervention values in both groups (p<.01). Other assessed items such as trunk flexibility and lumbar extensor endurance and lumbar flexor endurance were significantly increased post-intervention in both groups compared to pre-intervention values (p<.01). There was no significant difference in all parameters between both groups (p>.05). CONCLUSION: Our results indicate that the neurodynamic technique may be useful for improving low back pain in patients with lumbar instability.

Limited Impact of Music Therapy on Patient Anxiety with the Large Loop Excision of Transformation Zone Procedure - a Randomized Controlled Trial

  • Kongsawatvorakul, Chompunoot;Charakorn, Chuenkamon;Paiwattananupant, Krissada;Lekskul, Navamol;Rattanasiri, Sasivimol;Lertkhachonsuk, Arb-Aroon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2853-2856
    • /
    • 2016
  • Background: Many studies have pointed to strategies to cope with patient anxiety in colposcopy. Evidence shows that patients experienced considerable distress with the large loop excision of transformation zone (LLETZ) procedure and suitable interventions should be introduced to reduce anxiety. This study aimed to investigate the effects of music therapy in patients undergoing LLETZ. Materials and Methods: A randomized controlled trial was conducted with patients undergoing LLETZ performed under local anesthesia in an out patient setting at Ramathibodi Hospital, Bangkok, Thailand, from February 2015 to January 2016. After informed consent and demographic data were obtained, we assessed the anxiety level using State Anxiety Inventory pre and post procedures. Music group patients listened to classical songs through headphones, while the control group received the standard care. Pain score was evaluated with a visual analog scale (VAS). Statistical analysis was conducted using Pearson Chi-square, Fisher's Exact test and T-Test and p-values less than 0.05 were considered statistically significant. Results: A total of 73 patients were enrolled and randomized, resulting in 36 women in the music group and 37 women in the non-music control group. The preoperative mean anxiety score was higher in the music group (46.8 VS 45.8 points). The postoperative mean anxiety scores in the music and the non-music groups were 38.7 and 41.3 points, respectively. VAS was lower in music group (2.55 VS 3.33). The percent change of anxiety was greater in the music group, although there was no significant difference between two groups. Conclusions: Music therapy did not significantly reduce anxiety in patients undergoing the LLETZ procedure. However, different interventions should be developed to ease the patients' apprehension during this procedure.

A Study on the Optimization of Image Quality and Dose in Chest PA Digital Radiography (디지털 흉부 방사선 검사의 화질과 선량의 최적화에 관한 연구)

  • Park, Han Sol;Kim, Myeong Seong;Jung, Hong-Moon;Lee, Jong Woong
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.55-61
    • /
    • 2017
  • There are no recommended test conditions for digital photography in Chest PA examinations. However, each company recommends shooting examinations of the high voltage applied to the previous analog examination. The condition that satisfies the value of 200 ~ 800 which is the recommended Exposure Index value recommended by Philips was selected, and the dose was evaluated by Monte Carlo simulation, and the SNR and CNR were compared. As a result, it was possible to reduce the effective dose up to 77% by controlling the tube voltage, tube current, and additional filter, not the conventional high voltage imaging method. Although there were some differences according to the test conditions, the image evaluation results were similar to the images. We will compare the exposure dose according to changes in tube voltage, tube current, and additional filter at the digital chest radiograph and evaluate the image quality of the image to propose optimal conditions.

Analysis on DTV Indoor Reception Environments (디지털 TV 실내수신 환경 분석)

  • Suh, Young-Woo;You, Ho-Jin;Park, Min-Ho;Park, Joon-Sung;Kim, Gyu-Young;Seo, Jong-Soo
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.636-650
    • /
    • 2008
  • DTV has a great advantage as compared to Analog TV in picture quality under low reception field strength. Various high quality tuners have been developed to result in much smaller Noise Figure of the receivers and many trials for receiving DTV signal through indoor antenna. In this paper, results of intensive field tests on the indoor reception of DTV are presented. Tests were carried out around Seoul-Gyeonggi Metropolitan area. Commercial directional and omni-directional antennas and 5th generation receiver were used for reception availability tests. The effects of heights, locations, and types of the house as well as the distance to the transmitter on the reception performances are analyzed. Our test results will be applied to improve the indoor reception environment of DTV.

FAULT DETECTION COVERAGE QUANTIFICATION OF AUTOMATIC TEST FUNCTIONS OF DIGITAL I&C SYSTEM IN NPPS

  • Choi, Jong-Gyun;Lee, Seung-Jun;Kang, Hyun-Gook;Hur, Seop;Lee, Young-Jun;Jang, Seung-Cheol
    • Nuclear Engineering and Technology
    • /
    • v.44 no.4
    • /
    • pp.421-428
    • /
    • 2012
  • Analog instrument and control systems in nuclear power plants have recently been replaced with digital systems for safer and more efficient operation. Digital instrument and control systems have adopted various fault-tolerant techniques that help the system correctly and safely perform the specific required functions regardless of the presence of faults. Each fault-tolerant technique has a different inspection period, from real-time monitoring to monthly testing. The range covered by each faulttolerant technique is also different. The digital instrument and control system, therefore, adopts multiple barriers consisting of various fault-tolerant techniques to increase the total fault detection coverage. Even though these fault-tolerant techniques are adopted to ensure and improve the safety of a system, their effects on the system safety have not yet been properly considered in most probabilistic safety analysis models. Therefore, it is necessary to develop an evaluation method that can describe these features of digital instrument and control systems. Several issues must be considered in the fault coverage estimation of a digital instrument and control system, and two of these are addressed in this work. The first is to quantify the fault coverage of each fault-tolerant technique implemented in the system, and the second is to exclude the duplicated effect of fault-tolerant techniques implemented simultaneously at each level of the system's hierarchy, as a fault occurring in a system might be detected by one or more fault-tolerant techniques. For this work, a fault injection experiment was used to obtain the exact relations between faults and multiple barriers of faulttolerant techniques. This experiment was applied to a bistable processor of a reactor protection system.