• Title/Summary/Keyword: Anaerobic septic tank

Search Result 10, Processing Time 0.034 seconds

The Effect of Hydraulic Loading on the Performance of Biofilter System (수리부하량 변화에 따른 바이로필터의 처리효율에 관한 연구)

  • 방천희;김철성;권순국
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.789-794
    • /
    • 1999
  • The performance of a small on-site wastewater treatment system consisting of an anaerobic septic tank and upgraded absorbent biofilter was investgted . The anaerobic septic tank was used as a pre-treatment of the absorbent Biofitler instead of the primary clarifier. The treatment capacity of the system was examined by changing the hydraulinc loadings to the Absorbent Biofilter as 2.5㎥/day , 4.5㎥/day, 6.0㎥/day, respective. The effluent from the septic tank was fed into the Absorbent Bilfilter. Based on the experimental results, the quality of treated wastewater satisfied the regulation and the BOD and SS was removed down to approximately 5mg/$\ell$ and 1mg/$\ell$, respectively.

  • PDF

Development of Amalgamated Septic Tank using Mineral Sintered Body (광물 소결체를 이용한 합병정화조 개발에 관한 연구)

  • 김광수;김영훈;강헌찬
    • Resources Recycling
    • /
    • v.9 no.4
    • /
    • pp.56-62
    • /
    • 2000
  • This study was introduced an amalgamated septic tank system using mineral sintered body was made from non-metallic minerals with a ability being attached or accelerating a vitality of soil microorganism for the effective wastewater treatment. Experimentally, we made an amalgamated septic tank appling anaerobic-aerobic process experimental facilities to two personal houses for handling a residental sewage directly on a small scale from the place of origin. The results are shown as follows; The COD\ulcorner and BOD of effluent were about 10 mg/l after the treatments and T-N removal efficiency was 60-70%. Moreover these results suggested the possibility of denitrification without adding organics and more than 80% of T-P removal also showed the possibility of wastewater treatment biologically.

  • PDF

Treatability Study for the Nightsoil and Septic Tank Sludge by Anaerobic Digestion (혐기성(嫌氣性) 소화방식(消化方式)에 의한 분뇨(糞尿)와 정화조(淨化槽)슬러지의 혼합처리(混合處理) 실험(實驗)에 관한 연구(硏究))

  • Lee, Kwang Ho;Shin, Eung Bai;Ham, Kun Yeun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.2 no.1
    • /
    • pp.69-80
    • /
    • 1982
  • This study was performed to increase the treatment efficiency of the existing anaerobic digestion facilities of the nightsoil treatment plants. Bench-scale anaerobic digesters were operated to evaluate the effect of the ratio (7:3 and 9:1) of the mixture of nightsoil and septic tank sludge on treatment efficiency. The laboratory experiments have demonstrated that the ratio of the mixture does have an effect on the organic removal efficiency. The nightsoil to septage ratio of 7 to 3 appears to yield a higher efficiency than the ratio of 9 to 1. The percent removals of 7 to 3 ratio are 87 % BOD, 82 % COD, 66 % TS, and 78 %. VS whereas those of 9 to 1 ratio are 80 % BOD, 80 % COD, 63 % TS, and 76 % VS. This study also showed that the mixed treatment of the nightsoil and septic tank sludge will be possible at the nightsoil treatment plant.

  • PDF

Attached Treatment using Combined Septic Tank and Soil Filter of Treated Livestock and Farm House Wastewater (축산폐수 처리수 및 농가 생활잡배수의 합병정화조와 Soil Filter 에 의한 연계처리)

  • Kim, Eun-Ho;Park, Hyun-Geoun;Sung, Nak-Chang
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.4
    • /
    • pp.329-334
    • /
    • 1998
  • This study was conducted in order to investigate removal rate of organic matter, nitrogen and phosphorus to reduce environmental polluation with treatment to attach combined septic tank to 3 stage soil filter after mixing anaerobic treated water of livestock wastewater and low concentrated wastewater generated in farm house. Because anaerobic filter bed was packed in combined septic tank and a microorganism was accumulated in combined septic tank with increasing hydraulic retention time(HRT), if HRT $4{\sim}12day$, CODcr was removed $63.4{\sim}84.0%$. Also, $NH_4\;^+-N$ and $PO_4\;^{3-}-P$ were removed $3.9{\sim}5.4%$ and $18.3{\sim}29.0%$, respectively. In being re-treated by 3 stage soil filter, although hydraulic loading rate was gradually increased, CODcr, $NH_4\;^+-N$ and $PO_4\;^{3-}-P$ were removed above 90% due to filtration, adsorption, ion exchange, and action of soil microorganism. Generally, the attached treatment of combined septic tank and 3 stage soil filter did suitably treat livestock wastewater to water standard of discharge applied from '96 year, in view of decreasing pollution loading amount and recycling of agricultural water.

  • PDF

Treatability Study on the SepticTAnk Sludges

  • Byung Soo Yang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 1981
  • The characteristics of septic tank sludges were investigated and the kinetic coefficients in the aerobic biodegradation were evaluated from bach treatability tests. Using an unbiased statistical method, the estimated values, k (substrate removal rate coefficient) =0. 0175hr-1 at 17\ulcornerC, K. (Michaelis Menten constant) = 248mg/ e, a (cell yield coefficient)=0.625, and Kd (cell decay coefficient:' =0. 00192hr-1 were obtained based on biodegradable COD(mg/ \ulcorner) and volatile suspended solids(mg/\ulcorner). The relationship between COD and BOD, COD (mg/\ulcorner) =2. 1 BOD(mg/\ulcorner) +250, also was established for the septic tank sludges. Dilution was inevitable for the grit removal because of the high viscosity of the sludges. An aerobic activated sludge process rather than anaerobic processes was recommended for the removal of soluble organics after the removal of grit and suspended solids. A multi-stage activated sludge process was adapted for this highly concentrated and not easily-degradable waste. It was estimated that a four-stage activated sludge process would require 40 hours retention time compared to 92 hours for a single-stage process, 52 hours for a double-stage process, and 46 hours for a three stage process in order to achieve an effluent quality of 84mg/ e COD( 40mg/ e BOD) with about 4, OOOmg/ \ulcorner MLSS from an influent quality of I, 500mg/ t COD(714mg/.e BOD), while multi-stages beyond four stage would not save the required retention time significantly.

  • PDF

An Improved Treatment of Animal Wastewater

  • Oh, I.H.;Kim, B.S.;Lee, S.R.;W.J.Maeng
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.1379-1394
    • /
    • 1993
  • The purpose of this study is to examine the purification efficiency of the septic tank method which has been applied by the most of Korean livestock farms, in terms of anaerobic and aerobic treatment. Except several days in summer, BOD of effluent shows 1,500 -3,000 ppm by anaerobic process. In most cases , it exceeds according to the seasons show an increase by decrease of temperature. The removal effect on T-N is hardly found. The suspended solids contents of effluent are reduced to the level of 50-90%. Although BOD contents of effluent are kept high in the beginning, the removal rate of BOD shows 80 percent in the latter half by the aerobic treatment . The removal efficiency of total nitrogen does not appear through the experimental period, but the contents of T-N are not increased in the aerobic process unlike in the anaerobic process. The total phosphorous contents in effluent keep a constant level of 14 mg/L in average. The removal rate of phosphorous shows 91 percent i the last stage.

  • PDF

Removal of Nutrients Using an Upflow Septic Tank(UST) - Aerobic Filter(AF) System (부패조와 호기성 여과공정을 이용한 영양염류 제거)

  • Park, Sang-Min;Jun, Hang-Bae; Bae, Jong-Hun;Park, Woo-Kyun;Park, Noh-Back
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.3
    • /
    • pp.232-238
    • /
    • 2010
  • The objective of this study was to investigate a small sewage treatment system. This system was developed to improve a nitrogen and phosphorus removal efficiency and generate less solid using upflow septic tank(UST) - aerobic filter(AF) system. The UST equipped with an aerobic filter, the filter was fed with both raw sewage and recycled effluent from the UST to induce the denitrification and solid reduction simultaneously. Overall removal efficiencies of COD and total nitrogen(TN) were above 96% and 73% at recycle ratio of 200%, respectively. Critical coagulant dose without the biochemical activity was found to be 40 mg/L. Removal efficiency of total phosphorus(TP) in influent was above 90% by chemical and biological reactions. Although the phosphorus concentration was low under the high alkalinity in raw sewage, the pH value was unchanged by the coagulant dose.

Reuse of Treated Sewage Water from Absorbent Biofilter System as Agricultural Water Resources (농업수자원으로서의 흡수성 Biofilter 처리수 재이용)

  • 권순국;김현욱;권용웅;조영현;박상원;임경래
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.151-159
    • /
    • 2003
  • Absorbent Biofilter Systems (ABS), composed of an anaerobic septic tank, a pump chamber and an absorbent biofilter tank, have been found to economically provide rural on-site wastewater treatment. This study was conducted to assess the potential of ABS effluent as an alternative water resource for agricultural and environmental use, with respect to the removal of pathogenic microorganism and their fertilization effect. A pilot scale ABS was used to compare its removal efficiency of pathogens from effluent water. Overall, more than 95 percent of Salmonella and E. coli were removed. This result demonstrates that a significant reduction in the pathogenic microorganism of effluents can occur in ABS, which implies the feasibility for the use of ABS effluent in agriculture and environment, with the provision of a further simple disinfection step, in order to satisfy the WHO guidelines for the microbiological quality in agriculture. In addition, because of the abundant nutritional content of ABS effluent, the substitution effect of fertilizer (N, P and K) in paddy irrigation, i.e. 2/3 for nitrogen, l/3 for phosphorus and 1/5 for potassium would be expected. Based on the experimental data, the ABS effluent could be used as a new alternative water resource for paddy irrigation, as well as for environmental purposes, such as supplying water to ecological parks in rural villages.

Effects of Hydraulic Rentention Time on Anaerobic Digestion of the Mixture of Nightsoil and Septic Tank Sludge (소화조(消化槽)의 수리학적(水理學的) 체류시간(滯留時間)이 분뇨(糞尿)와 정화조(淨化槽)슬러지 혼합물(混合物)의 혐기성소화(嫌氣性消化)에 미치는 영향(影響))

  • Lee, Kwang Ho;Yang, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.117-127
    • /
    • 1983
  • An experimental research was performed employing the two stage anaerobic digestion of the mixture of the nightsoil and septic tank sludge to determine the effects of various hydraulic retention time of the digestion on chemical characteristics and treatment effeciency, thus determining the proper retention time. Results of the research are as follows, 1. Volatile-acid decreased as HRT increased. 2. Alklinity and ammonia-N tended to increase as HRT increased as did pH values, however, were observed to be constant at higher HRT values than 15 days. 3. The removal efficiencies of TBOD, TCOD and VS increased as HRT increased. 4. The removal efficiency of volatile solid decreased as VS loading increased. 5. It was observed that the rates of gas production were: 0.33 with HRT of 5 days, 0.58 with HRT of 15 days and $0.57m^3/kg$ VS fed/day with HRT of 25 days respectively. It is believed that the highest rate of gas production was at HRT of 15 days. 6. The sludge settling experiment showed that the minimum settling time required to ensure the desired underflow concentraton was estimated to be 8.6 days.

  • PDF

Characteristics of Municipal Sewage Sludge Affecting the Biodegradation of a Plastic Material Under Aerobic Condition (호기적 조건에서 플라스틱 생분해에 영향을 미치는 도시 하수 오니의 성질)

  • Seo, In-Sun;Lee, Myung-Cheon;Kim, Byung-Hong;Shin, Pyong-Kyun
    • Microbiology and Biotechnology Letters
    • /
    • v.22 no.4
    • /
    • pp.436-442
    • /
    • 1994
  • The characteristics of activated sludge affecting the biodegradation of plastic materials under aerobic condition were studied using cellophane film as a model system. The activated sludges of site 3, which treat a mixture of domestic sewage and supernatant of septic tank, obtained from December 1993 to April 1994 showed similar biodegradation activities. Biodegradations for 28 days reached around 80%. Viable cell number of inoculums maintained at a level of 10$^{6}$~10$^{7}$ /ml. In this range, viable cell number showed no relationship with biodegradation activities. The activa- ted sludges of site 2, which treat a mixture of domestic sewage and anaerobic digest of nightsoil, obtained four times from April 1993 to April 1994 showed very different biodegradation activities ranged from 20% to 80% for 28 days. Inoculum size affects biodegradation significantly. One percent inoculum showed the best biodegradation among the inoculum sizes of 0.1, 1.0 and 10%. Ten percent inoculum revealed inhibitory effects on the biodegradation activity which can be greatly reduced by centrifugation and filtration. Filtration was better than centrifugation in reducing inhibitory effects.

  • PDF