• Title/Summary/Keyword: Anaerobic Treatment

Search Result 772, Processing Time 0.023 seconds

Treatment of Starch Wastewater by Anaerobic Digestion Combined with Hollow Fiber UF

  • No, Seong-Hui;Na, Jae-Un;Kim, Seon-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.745-748
    • /
    • 2000
  • Anaerobic digester coupled with hollow fiber membrane unit. Treatment of starch waste with anaerobic digester-membrane system was studied. $0.17\;m^2$ area of hollow fiber membrane unit of known pore size was immersed into laboratory-scale anaerobic digestion system. The gas production was about $0.74\;m^3/kg$ COD treated. The COD removal efficient was about 80-95% depending on the hydraulic retention time. Crossflow ultrafiltration as Post treatment to anaerobic filter. The study conducted with different membrane pore size indicated that membrane with 1,000,000 molecular weight cut-off size gave a higher COD removal efficiency in the range of 83-87% while giving a study flux of $120-130\;L/m^2\;{\cdot}\;h$. A study was conducted to see the long term clogging effect of membrane also.

  • PDF

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • 이민규;서근학
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.509-516
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

  • PDF

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • Lee, Min-Gyu;Suh, Kuen-Hack
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.123-123
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

A Study on the Mixed-Food Wastewater Treatment in an Anaerobic Packed Bed Reactor and Sludge Bed Reactor (혐기성 고정상반응기와 슬러지 Bed반응기에서 혼합-식품폐수처리에 관한 연구)

  • 안재동;김재우;장인용
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.4
    • /
    • pp.38-43
    • /
    • 1993
  • The characteristics of food wastewater treatment in an anaerobic packed bed reactor (APBR) with polyurethane as a packing material and sludge bed reactor (ASBR) was studied. The reactor of 9cm-ID, 150cm-height was fed in a continuous mode from bottom of reactor. For the purpose of constant temperature of reactor, water jacket was installed. The used packing materials was polyurethane sponge foam. Methane which was produced by decomposed organics collected at the top of the reactor for using as a fuel. The substrates used were synthetic, mixed and food wastewater. For the acclimatization of microorganisms, mixed wastewater was used. The major analyses were gas production, COD, pH and volatile acids. Based upon the completed works, the results are as follows: When food wastewater was fed the quantity of produced gas was less than that of synthetic wastewater, but food process saw higher methane content than synthetic process. As well as COD removal efficiency of food process reached at about 85%. In aspect of effluent volatile acid, food process showed low concentration of below 500 mg/l, therefore anaerobic reaction stabled. Conclusively food wastewater used can be digested by anaerobic treatment, especially anaerobic packed bed reactor showed 82% of COD removal, 75% of methane content, 10 l of gas production, and anaerobic sludge bed reactor did 79% of COD removal, 75% of methane content, 81 of gas production at 4 kgCOD/m$^3$day, 36$\circ$C.

  • PDF

Improvement of Organic Substances Indicators by Linked Ultra Violet-Advanced Oxidation Process After Ozonation for Anaerobic Digested Wastewater (소화탈리액 대상 오존 전처리와 Ultra Violet-Advanced Oxidation Process 연계 처리를 통한 유기물질 지표 개선)

  • Jaiyeop Lee;Jesmin Akter;Ilho Kim
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.5
    • /
    • pp.253-259
    • /
    • 2023
  • Bioreactors are devices used by sewage treatment plants to process sewage and which produce active sludge, and sediments separated by solid-liquid are treated in anaerobic digestion tanks. In anaerobic digestion tanks, the volume of active sludge deposits is reduced and biogas is produced. After dehydrating the digestive sludge generated after anaerobic digestion, anaerobic digested wastewater, which features a high concentration of organic matters, is generated. In this study, the decomposition of organic carbon and nitrogen was studied by advanced oxidation process. Ozone-microbubble flotation process was used for oxidation pretreatment. During ozonation, the TOC decreased by 11.6%. After ozone treatment, the TOC decreased and the removal rate reached 80.4% as a result of the Ultra Violet-Advanced Oxidation Process (UV-AOP). The results with regard to organic substances before and after treatment differed depending on the organic carbon index, such as CODMn, CODCr, and TOC. Those indexes did not change significantly in ozone treatment, but decreased significantly after the UV-AOP process as the linkage treatment, and were removed by up to 39.1%, 15.2%, and 80.4%, respectively. It was confirmed that biodegradability was improved according to the ratio of CODMn to TOC. As for the nitrogen component, the ammonia nitrogen component showed a level of 3.2×102 mg/L or more, and the content was maintained at 80% even after treatment. Since most of the contaminants are removed from the treated water and its transparency is high, this water can be utilized as a resource that contains high concentrations of nitrogen.

Operational Characteristics of UBF -Anaerobic Digestion of Landfill Leachate- (상향류식 혐기성 생물막 여상(UBF)의 운전 특성 -침칠수 처리를 중심으로-)

  • Kim, Hyeong-Seok;Kim, Chul;Sung, Nak-Chang
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.4
    • /
    • pp.49-54
    • /
    • 1996
  • The anaerobic landfill leachate treatment can surmount dilution problem of high concentration landfill leachate, collect methane gas as byproduct, and treat low phosphate concentration leachate because of low nutrient salt requirement. The problems of conventional anaerobic treatment that are requirement of large reactor because of low microbial growth rate(HRT=20-30 days) and low volumetric loading rate(VLR=0.5-2.0 kg $COD/m^3\cdot day$) are able to surmount by introduction of high rate anaerobic treatment. In this study, the upflow blanket filter(UBF) which is high rate anaerobic process was applyed to the landfill leachate treatment. The acceptable volumetric loading rate and HRT were 18.23 kg $SCOD/m^3\cdot day$ and 13 hrs. SCOD removal rate was over 90% at VLR 18.23 kg $SCOD/m^3\cdot day$. The methane gas yield was $0.15 lCH_4/g$ SCOD added(at STP) at VLR 18.23 kg $SCOD/m^3\cdot day$. The solids accumulation yield was 0.40 g VSS/g COD removed.

  • PDF

Treating Swine Wastewater by Anaerobic Bioreactors (혐기성 생물반응기에 의한 축산폐수의 처리)

  • Lee, Gook-Hee;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.54-60
    • /
    • 1999
  • Three different types of lab-scale anaerobic bioreactors, AF and two-stage ASBF-PR and ASBF-SP, were evaluated in treating swine wastewater by operating at $1{\sim}2$ days of hydraulic retention time with increasing organic loading rate upto 6.3 $kg-COD/m^3{\cdot}d$ at $35^{\circ}C$. Seeding the anaerobic bioreactors with waste anaerobic digester sludge from a municipal wastewater treatment plant was effective and a 40-day acclimation period was required for steady-state operation. Three anaerobic bioreactors were effective in treating swine wastewater with COD removal efficiency of $66.4{\sim}84.9$% and biogas production rate of $0.333{\sim}0.796m^3/kg-COD_{removed}{\cdot}d$. Increases of organic loading rate by increasing influent COD concentration and/or decreasing hydraulic retention time caused decreases in COD removal efficiency and increases in biogas production rate. At relatively high organic loading rate employed in this study, the treatment efficiency of AF and ASBF-PR were similar but superior than that of ASBF-SP, indicating that porosity and pore size of the media packed in the bioreactors are more important factors contributing the performance of to bioreactors than specific surface area of the media. TKN in swine wastewater must be removed prior to the anaerobic processes when anaerobic process is considered as a major treatment process since influent TKN concentration of $1,540{\sim}1,870mg/L$ to the bioreactors adversely affect the activity of methanogenic bacteria, resulting in decreases of treatment efficiency and biogas production rate by 50%.

  • PDF

Effects of Temperature on Production of Hydrogen in Anaerobic Fermentation (혐기성 발효에서 수소 생산 시 온도의 영향에 관한 연구)

  • Kim, Choong-Gon;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.467-475
    • /
    • 2007
  • This study was conducted to examine temperature effects on hydrogen production in anaerobic fermentation. 18 batch reactors were operated at mesophilic ($35^{\circ}C$) and thermophilic conditions ($55^{\circ}C$) to achieve maximum hydrogen production in anaerobic fermentation. Optimum hydrogen production conditions were also investigated at each temperature. Different trends were observed regarding pH effects on hydrogen production. This effect was not significant for mesophilic fermentation ($35^{\circ}C$). In this case, pH may not drop to interfere hydrogen production during the test. However, hydrogen production decreased without pH control for thermophilic condition ($55^{\circ}C$). Effects of heat treatment were observed for both fermentation process. Hydrogen production with heat treatment was higher than hydrogen production without heat treatment for both fermentation processes. The amount of produced hydrogen for each substrate concentration with temperature changes showed that more hydrogen was produced at $35^{\circ}C$ than at $55^{\circ}C$.

Treatment of Organic Wastewater by the Anaerobic Fixed-Film Process (혐기성 생물막법에 의한 유기성 배수의 처리)

  • 김용대;정경훈
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.41-47
    • /
    • 1991
  • A study on the effects of volumetric loading rate, surface loading rate and hydraulic. retention time (HRT) for the anaerobic treatment was conducted with the anaerobic fixed-film process using synthetic wastewater at lower temperature than that of conventional anaerobic treatment. The results are as follows 1. Alkalinity and pH value decreased as the hydraulic retention time increased 2. Increase of the volumetric lodaing rate led to increasl of effluent COD concentration and decrease of COD removal efficiency. 3. The removed volumetric loading rate increased linearly according to the increase of the volumrtric loading rate. 4. Similarly, the linear increase of the removed surface loading rate was noticed with an increase of the surface loading rate.

  • PDF

A Study on Biological Treatment of Nitrogen and Phosphorus (생물학적 질소 및 인 제거에 관한 연구)

  • 이현동;유형열;김원만
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.1
    • /
    • pp.45-56
    • /
    • 1992
  • The Anaerbic Anoxic/oxic process is one of the biological treatment methods to remove nitrogen and phosphorus effectively which are nutritional elements for eutrophication. Supernatant of primary sediment of Anaerobic digester is used as a carbon source instead of methanol methanol supply in usual A$_{2}$/O process. The efficiency of the following treatment processes are as follow : 1) Changing recycle ratio in the usual A$_{2}$/O process without the stage of Anaerobic digester. 2) Changing recycle ratio in the usual A$_{2}$/O process with the supernatant supply of the Anaerobic digester. In the result of comparison, changing recycle ratio is almost no effect in the removal of phosphorus, however the effect of removal in nitrogenous substance are remarkable, and the effect of Anaerobic digester is not as effective as expected because the BOD removed in the digester partly, the rate of phosphorus to the BOD exceed pertinent range.

  • PDF