• 제목/요약/키워드: Amplitude ratio

검색결과 966건 처리시간 0.025초

Amplitude Dependency of Damping in Buildings and Critical Tip Drift Ratio

  • Tamura, Yukio
    • 국제초고층학회논문집
    • /
    • 제1권1호
    • /
    • pp.1-13
    • /
    • 2012
  • The importance of appropriate use of damping evaluation techniques and points to note for accurate evaluation of damping are first discussed. Then, the variation of damping ratio with amplitude is discussed, especially in the amplitude range relevant to wind-resistant design of buildings, i.e. within the elastic limit. The general belief is that damping increases with amplitude, but it is emphasized that there is no evidence of increasing damping ratio in the very high amplitude range within the elastic limit of main frames, unless there is damage to secondary members or architectural finishings. The damping ratio rather decreases with amplitude from a certain tip drift ratio defined as "critical tip drift ratio," after all friction surfaces between primary/structural and secondary/non-structural members have been mobilized.

선형동흡진기의 매개변수가 감쇠진동계의 진동특성에 미치는 영향 (Effects of parameters of a linear dynamic vibration absorber on the vibrational characteristics of damped vibrational systems)

  • 윤장상;이양우;송창섭
    • 한국정밀공학회지
    • /
    • 제6권4호
    • /
    • pp.136-144
    • /
    • 1989
  • This paper presents the vibrational characteristics of linear damped vibrational systems with a linear dynamic absorber. The amplitude ratios of main vibrational system are derived from the equation of motion for the system, and optimal natural frequency ratio and damping ratio of dynamic absorber are obtained by computer simu- lation, which minimize the amplitude ratio of main vibrational system for the whole range of the frequency ratio. And, the effects of the parameters on the amplitude ratios are investigated. As the results, the effect of the natural frequency ratio on the amplitude ratio of main vibrational system is more important than that of the damping ratio of dynamic absorber as damping ratio of main vibrational system becomes larger. For the case of large damping ration of main vibrational system becomes larger. For the case of large damping ratio of main vibration system, the amplitude ratios are not decreased dramationally in spite of inoreasing mass ratio.

  • PDF

순간주파수 분석기법의 응용 (2) -주파수의 부호를 결정하는 조건- (Application of Instantaneous Frequency Analysis(II) -Conditions of Existing Negative Frequency Components-)

  • 김정태;임병덕
    • 대한기계학회논문집
    • /
    • 제18권4호
    • /
    • pp.1057-1063
    • /
    • 1994
  • An instantaneous frequency analysis is a technique to examine a signature for the rotating machinery if the signal has several transitions within a cycle. This paper discusses the conditions of existing negative frequency components in the instantaneous frequency. By using a signal consisted of two frequency components, the instantaneous frequency analysis is conducted while the amplitude ratio between two frequency components has been changed. The analysis shows that, depending on the amplitude ratio, the instantaneous frequencies have averaged, zero-valued, or negative components. It turns out that the negative-valued instantaneous frequencies, which have been regarded as the noise effect, are the consequence of the calculation process for the multisignal components. The criteria of existing the negative values in instantaneous frequencies is given in terms of the relative amplitude ratio and the frequency difference. Especially when the amplitude ratio approaches to 1, the instantaneous frequency fluctuates ${\pm}\infty$ in theory, which implies that instantaneous frequency has unstable region around the amplitude ratio, 1.Also, as the frequency difference between major signal components is increased, the region of existing negative instantaneous becomes broader. In an instantaneous frequency analysis, therefore, a narrow band analysis is suggested, with extreme care if the amplitude ratio approaches to 1. In this paper, a vibration signal monitored from a rotating machinery is also examined as an application example in order to show the existence of negative instantaneous frequencies components.

국내 고층건물의 RD법에 의한 감쇠율의 진폭의존성 (Amplitude dependent damping ratio of domestic tall building by RD method)

  • 윤성원
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.89-95
    • /
    • 2004
  • The measured damping ratio was analysed to obtain amplitude dependence. Wind-induced vibration of 20 story steel-framed building was measured to investigate amplitude dependence by RD method. Micro-tremo vibrations of 20 RC bearing wall typed buildings were performed to analysis the amplitude dependence by formula proposed by Tamua and ESDU. Amplitude dependent damping in 17 story steel-framed building was showed clearly in the increasing rate of 9%. But Amplitude dependent damping of 17 RC bearing wall typed buildings was very low in the increasing rate of 2.5%. The tendency of dynamic properties of building obtained here are useful for the validation of dynamic properties of buildings in the evaluation of serviceability.

  • PDF

감쇠진동계에 부착된 복합동흡진기의 효과에 관한 연구 (A Study on the Effects of Dual Dynamic Vibration Absorber for Damped Vibration System)

  • 안찬우;최석창;김동영
    • 소음진동
    • /
    • 제7권6호
    • /
    • pp.1039-1048
    • /
    • 1997
  • This paper describes the effects of dual dynamic vibration absorbers attached to a primary vibration system with damping. The efficiency of dual dynamic vibration absorbers was investigated with the height of amplitude ratio at the resonance frequency ratio of the damped vibration system according to mass ratio, natural frequency ratio and damping ratio. The variation of amplitude ratio related to frequency ratio of primary vibration system is verified experimentally and theoretically according to dual dynamic vibration systems using computer program designed to find mutual relationship between two absorbers.

  • PDF

코일스프링과 오일댐퍼를 가지는 동흡진기의 특성에 관한 연구 (A Study on the Characteristics of Dynamic Vibration Absorber with Coil Spring and Oil Damper)

  • 김광식;안찬우
    • 한국해양공학회지
    • /
    • 제2권1호
    • /
    • pp.170-175
    • /
    • 1988
  • A study on the dynamic vibration absorber with coil spring and oil damper was carried out both theoretically and experimentally. A main mass is attached to a foundation using coil spring and oil damper. A harmonic motion was applied to the foundation. The effects of the dynamic vibration sbsorber are theoretically summarized in graphs, and tested on a vibratory model for the isolation of actual mechanical vibration. As a result, the first resonance amplitude ratio increased and the second resonance amplitude ratio decreased as the absorber spring constant increased. When the absorber mass increase, the first resonance amplitude ratio is decreased and the second resonace amplitude ratio is increased.

  • PDF

가진입력의 크기에 따른 동조액체기둥감쇠기의 비선형 특성 (Nonlinear Characteristic of a Tuned Liquid Column Damper under Various Excitation Amplitude)

  • 이성경;이혜리;민경원
    • 한국소음진동공학회논문집
    • /
    • 제19권11호
    • /
    • pp.1167-1176
    • /
    • 2009
  • The objective of this study is to investigate design parameters of a tuned liquid column damper(TLCD), which is affected by various excitation amplitude, through shaking table test. Design parameters of a TLCD are examined based on the equivalent tuned mass damper(TMD) model of a TLCD, in which the nonlinear damping of a TLCD is transposed to equivalent viscous damping. Shaking table test is carried out for a TLCD specimen subjected to harmonic waves with various amplitude. Transfer functions are ratios of liquid displacement of TLCD and control force produced by a TLCD, respectively, with respect to the acceleration excited by a shaking table. They are derived based on the equivalent TMD model of a TLCD. Then, the variation of design parameters according to the excitation amplitude is examined by comparing analytical transfer functions with experimental ones. Finally, the dissipation energy due to the damping of a TLCD, which is experimentally observed from the shaking table test, is examined according to the excitation amplitude. Comparisons between test results and analytical transfer functions showed that natural frequencies of TLCD and the ratio of the liquid mass in a horizontal column to the total liquid mass do not depend on the excitation amplitude, while the damping ratio of a TLCD increases with larger excitation amplitude.

비동기 히브 및 피치 운동에 따른 에어포일 비정상 공력 특성 Part 2 : 피치 진동운동 진폭 (Unsteady Aerodynamic Characteristics of an Non-Synchronous Heaving and Pitching Airfoil Part 2 : Pitching Amplitude)

  • 지승환;한철희
    • 항공우주시스템공학회지
    • /
    • 제17권6호
    • /
    • pp.63-71
    • /
    • 2023
  • 본 연구에서는 NACA 0012 에어포일을 사용하여 히브와 피치 진동운동의 주파수가 다른 경우에 대하여 피치진동운동의 진폭에 에어포일의 비정상 공력 특성에 미치는 영향을 수치적으로 연구했다. 양력계수는 주파수비가 1.0인 경우 피치진동운동의 진폭이 30°와 20°인 경우 양력계수 값이 크지 않았으나 10°인 경우 양력계수값이 크게 증가했다. 주파수비가 0.5인 경우 양력계수값은 전체적으로 주파수비가 1.0인 경우보다 큰 값을 가졌으며, 진폭이 감소할수록 양력이 크게 증가하였다. 항력계수는 주파수비가 1.0인 경우 전체적으로 추력이 크게 발생하였으며 진폭이 감소할수록 추력의 크기가 감소하였다. 주파수비가 0.5인 경우 피치진동운동의 진폭이 30°인 경우 항력이 발생하였으나 진폭이 10°인 경우 추력이 발생하였다. 향후 본 연구를 확장하여 에어포일의 히브진동운동의 진폭변화에 따른 비정상 공력 특성 변화를 연구할 계획이다.

미터링 오리피스 압력 진폭을 이용한 방향제어밸브 대역폭 주파수에 관한 연구 (A Study on the Bandwidth Frequency of Directional Control Valves based on the Amplitude of the Metering-Orifice Pressure)

  • 김성동;전세형;신대영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제14권2호
    • /
    • pp.1-8
    • /
    • 2017
  • The spool displacement of a directional control valve can be considered as the standard signal for the measurement of its bandwidth frequency. When the spool displacement is not available, the metering-orifice system is suggested in this study as an alternative way to measure the - 3 dB amplitude-ratio bandwidth frequency of the hydraulic directional-control valve. The amplitude ratio of the metering-orifice pressure can be adjusted to equal that of the spool displacement through the controlling of the metering-orifice opening area. A series of experiments were conducted to verify the effectiveness of the metering-orifice system. The metering orifice was confirmed as adequate for the measurement of the - 3 dB amplitude-ratio bandwidth frequency.

다중 과하중에 의한 A1 7075-T6 합금의 피로균열 성장지연현상에 관한 연구 (A Study on Fatigue Crack Growth Retardation Phenomena of Al 7075--T6 Alloy under Multiple overload(I))

  • 이택순;이유태
    • 한국해양공학회지
    • /
    • 제6권1호
    • /
    • pp.96-104
    • /
    • 1992
  • Aircraft structures and engineering structures are always subject to variable amplitude loads. Variable amplitude loads include some kind of loading history; for example, constant amplitude load, single peak overload and block overload etc. Crack growth under variable amplitude loading exhibits retardation effect. In this study, the 4 point bending fatigue test was performed by hydrolic servo fatigue testing machine on 7075-T6 Al-alloy. The retardation effect of overload ratio and numbers of overload cycle was quantitatively studied. 1) Change of retardation effect against increment of overload ratio is more evident when the multiple overload is applied than single overload is done. 2) The number of overload cycle is very important factor about the crack growth retardation effect when the overload ratio is more than 1.75; that is not when the overload ratio is less than 1.75. 3) Overload affected zone size increased gradually by increment of crack growth retardation effect. 4) Crack driving force is more greatly reduced when the crack tip branched off two direction than it sloped to one direction.

  • PDF