• 제목/요약/키워드: Amplitude and Latency

검색결과 144건 처리시간 0.028초

주파수 통과대역필터가 작업 기억 관련 사건관련전위 P300에 미치는 영향 (Effects of the Frequency Band Pass Filter on the P300 Event-related Potential in the Working Memory)

  • 박웅식;이정우
    • 대한통합의학회지
    • /
    • 제8권2호
    • /
    • pp.131-138
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effects of the frequency band pass filter on the P300 event-related potential in the working memory. Methods : The subjects were 20 women in their 20s who applied for participation in the experiment. Event-related potentials (ERPs) were elicited using 3-back tasks for the working memory, and were recorded from Fz, Cz, and Pz scalp electrodes. The high-pass filters were set to 0.01, 0.1, and 0.3 Hz for analysis purposes, and the low-pass filters were set to 30 and 15 Hz. The 3-back task was presented for a total of 100 times, among which 30 times were designated for the target stimulation (a matched number) and 70 times for the non-target stimulation (an unmatched number). The temporal interval between each stimulation was set at 1 second, while each time duration was randomly presented between 2 to 4 seconds. ERP were analyzed for the P300 recorded from Fz, Pz and Cz scalp electrodes. Results : Latency and amplitude had no significant interaction effects in both the high- and low-pass filters. For the main effects, the latency and amplitude of the P300 event-related potential had no significant difference in the high-pass filters, but the latency had a significant difference in the low-pass filter of Fz, and the amplitude had a significant difference in the low-pass filter of Pz. Conclusion : The results of this study showed that the less than 0.3 Hz high filters had no effects on the differences between the latency and amplitude of the P300 event-related potential in the working memory. The 30Hz low-pass filter, however, was found to be useful for recording the P300 event-related potential in the working memory.

조현병 환자의 치료 반응에 따른 Mismatch Negativity 변화 (Association of Therapeutic Response and Change of Mismatch Negativity in Schizophrenia Patients)

  • 이소연;이의혁;김종우;강원섭
    • 생물정신의학
    • /
    • 제24권4호
    • /
    • pp.188-195
    • /
    • 2017
  • Objectives Schizophrenia is characterized by disturbances in perception and cognition. Attenuated mismatch negativity (MMN) reflects central auditory dysfunction in schizophrenia. The aim of this study is to compare MMN changes before and after treatment in schizophrenia patients and to assess their association with treatment response. Methods Twenty-three schizophrenia patients underwent an oddball paradigm. MMN was calculated by the difference waveforms of the event-related potentials (ERPs) elicited by subtracting standard from deviant stimulus. The clinical symptoms were measured by the Positive and Negative Syndrome Scale (PANSS), the Psychotic Symptom Rating Scale (PSYRATS). Follow-up evaluation was conducted when the PANSS total score decreased by 30% or more (treatment response group) or before discharge (non-response group). Results The treatment response group showed significantly larger MMN amplitude improvement and latency reduction than the non-response group after treatment (Fz ; mean amplitude p = 0.035, FCz ; p = 0.041). The auditory hallucination group showed shorter latency than that of the group without hallucinations. Additionally, auditory hallucination was associated with prolonged MMN latency and shortened after treatment in the auditory hallucination response group (Fz ; p = 0.048). Conclusions These results suggest that the attenuated MMN amplitude reflects the progression of the disease. The increment of MMN amplitude and shortening of latency after treatment may reflect cognitive functional recovery of central auditory sensory processing.

Electrodermal Activity at the Left Palm and Finger in Accordance with the Pressure Stimuli Applied to the Left Scapula

  • Kim, Jae Hyung;Kim, Su Sung;Son, Jung Man;Kim, Yung Jae;Baik, Sung Wan;Jeon, Gye Rok
    • 센서학회지
    • /
    • 제25권4호
    • /
    • pp.235-242
    • /
    • 2016
  • A system for measuring the electrodermal activity (EDA) signal occurring at the sweat glands in the left palm and left finger of the human body was implemented in this study. The EDA measurement system (EDAMS) consisted of an algometer, a biopotential measurement system (BPMS), and a PC. Two experiments were performed to evaluate the function and clinical applicability of EDAMS. First, an experiment was carried out on the linearity of the voltage and the pressure that comprised the output signals of the algometer used for applying a pressure stimulus. Second, the amplitude of the EDA signal acquired from the electrode attached to the left palm or finger was measured while increasing the pressure stimulus of the algometer. When the pressure stimulus of the algometer applied to the left scapula was increased, the amplitude of the EDA signal increased. The amplitude of the EDA signal at the left palm was observed to be greater than that at the left finger. The amplitude of the EDA signal was observed to increase in a relatively linear relation with the intensity of the pressure stimuli. In addition, the latency of the EDA signal acquired from the electrode attached to the left palm or finger was measured while increasing the pressure stimulus of the algometer. When the pressure stimulus of the algometer applied to the left scapula was increased, the latency of the EDA signal decreased. The latency of the EDA signal at the palm was observed to be less than that at the finger. The latency of the EDA signal was observed to decrease nonlinearly with the pressure stimuli.

신경 신장 적용 강도에 따른 신경흥분성 변화 (Changes in Nerve Excitability Depending on Intensity of Neural Stretching)

  • 김종순
    • PNF and Movement
    • /
    • 제19권2호
    • /
    • pp.195-203
    • /
    • 2021
  • Purpose: Neurodynamic tests are used to examine neural tissue in patients with neuro-musculoskeletal disorders, although this has not yet been established in the intensity of nerve tension application. This study aimed to investigate the acute effects of neural stretching intensity on nerve excitability using the latency and amplitude of nerve conduction velocity test (NCV) analysis. Methods: Thirty young, healthy male and female subjects (mean age = 21.30 years) voluntarily participated in this study. Nerve excitability was assessed using the median sensory NCV test. The latency and amplitude of the NCV test were measured under four different conditions: reference phase (supra-maximal stimulus, without neural stretching), baseline phase (2/3 of the supra-maximal stimulus, without neural stretching), weak stretch phase (2/3 of the supra-maximal stimulus, with weak neural stretching), and strong stretch phase (2/3 of the supra-maximal stimulus, with strong neural stretching). Results: The NCV latency was significantly delayed after one minute of neural stretching at the baseline, weak phase, and strong phase in comparison with the reference phase. The NCV latency was significantly delayed by increasing the strength of neural stretching. Furthermore, the NCV amplitude was significantly increased at the weak and strong phases, which were under neural stretching, in comparison with the baseline phase. The NCV amplitude was significantly increased by increasing the strength of the neural stretching. Conclusion: Transient neural stretching as a neurodynamic test can increase the sensitivity of the nerve without negatively affecting the nervous system. However, based on the results of this study, strong neural stretching in the neurodynamic test may delay the transmission of nerve impulses and hypersensitivity.

정상 성인에서 청성유발 피부전위 (Auditory Evoked Skin Potential in Normal Subjects)

  • 허승덕;정동근;서덕준;김광년;김기련;강명구;김리석
    • 음성과학
    • /
    • 제12권2호
    • /
    • pp.81-88
    • /
    • 2005
  • Electrodermal activity(EDA) is a bio-electric signal which occurs at the skin surface during the sweating. EDA reflects the activity of the sympathetic axis of the autonomic nervous system. EDA is associated with the eccrine sweat gland at the palmar and plamar surface. This study was aimed to characterize the relationship between EDA and auditory stimulus intensities. Acoustic stimulus used in this study were 500 Hz, 1 kHz, 2 kHz of narrow band noise, which were representative of speech frequencies in audible range. Stimulus intensity between 90 and 30 dB in 10 dB within dynamic range. After deriving the minimum stimulus intensity(threshold of skin potential) which elicited skin potential, and then the latency and amplitude were derived from waveform of skin potential, each latency and amplitude were compared to stimulus intensity. The waveform of skin potential were recorded stably, and the threshold of skin potential appeared nearly the hearing threshold level of the participant. The latency was decreased and the amplitude was increased according to the increase of the stimulus intensity. These results suggest that auditory evoked skin potential can be applicable to auditory assessment and audiological diagnosis tool.

  • PDF

T-반사 응답의 분석을 위한 디지탈 신호 처리 시스템의 설계 (Design of a Digital Signal Processing System for Analysis of Tendon Reflex Response)

  • 김재국;권도철
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.221-226
    • /
    • 1996
  • Tendon reflex responses generated from mechanical stimulus had been studied for quantitative analysis of activity of tendon reflex, especially patellar tendon reflex responses are known to be a criterion for diagnosing the L3 or L4 radiculopathy. In this paper, we developed a digital signal processing system for analysis of the tendon reflex response. The system parameter, i.e., $\textit{sampling frequency, pre-amplification gain, input channel and filter bank}$ are selected by Using software switches. From the view points of flexibility, the system hardware is connected to an IBM PC for analyzing the tendon reflex parameters, amplitude, latency duration We applied the proposed system to the analysis of the patellar tendon reflex reponses. In the experiment, we measured latency, duration, amplitude of the reflex action potentials generated from vastus medialis, vastus lateralis and rectus femoris that compose quadriceps, and the measured data are analyzed througll the ANOVA test which has 5% significant level. As a result, we showed that the mean amplitude of reflex action potential at the vastus lateralis is larger than any other muscle and the mean latency of the reflex action potential at the rectus femoris is shorter than any other muscle.

  • PDF

근전도 전자 망치를 이용한 깊은힘줄반사의 측정자 간 신뢰도 (Inter-Rater Reliability of the Deep Tendon Reflex by using EMG Electric Reflex Hammer)

  • 이정우;서태화
    • 대한통합의학회지
    • /
    • 제10권4호
    • /
    • pp.137-143
    • /
    • 2022
  • Purpose : The purpose of this study was to evaluate the reliability analysis of the deep tendon reflex by using electromyography (EMG). Methods : The study was tested on 30 volunteers who are women in their 20s. Using an electronic reflective hammer of EMG, deep tendon reflex was measured on all subjects with the participation of three trained physical therapists as raters. First, the subjects were comfortably seated on a table with their knees bent at 90 °. The three raters tapped the electric hammer at intervals of 10 seconds to avoid habituation until a total of 10 compound muscle action potential records were collected. Intraclass correlation coefficients (ICCs) were calculated to assess the inter-rater reliability of the deep tendon reflex with the use of EMG. The items of analysis included amplitude (mV), latency (ms), duration (ms), and area (mV × ms) of the compound evoked potentials. Results : Based on the average records of 10 compound muscle action potential, excellent reliability (ICC: .912) was achieved in terms of area, and there was good reliability in terms of latency (ICC: .795) and duration (ICC: .800). In the shortest latency of the compound muscle action potential, good reliability was achieved in terms of amplitude (ICC: .865), duration (ICC: .781), and area (ICC: .832). In the amplitude of peak-to-peak of compound muscle action potential, excellent reliability was recorded in terms of amplitude (ICC: .924), and good reliability was recorded in terms of duration (ICC: .801) and area (ICC: .874). Conclusion : The findings in this study indicate that electromyography via an electric hammer is a reliable method of assessing and measuring deep tendon reflexes. Especially, it may be an excellent gauge in the area of average values of the compound muscle action potentials and the amplitude of peak-to-peak of compound muscle action potentials.

정신분열증의 사건관련유발전위에 대한 연구(I) -정신분열증 환자의 사건관련유발전위- (P3 in the Auditory Event-Related Evoked Potential of Schizophrenia(I) -P3 in the Schizophrenics-)

  • 오동재;장환일
    • 수면정신생리
    • /
    • 제1권1호
    • /
    • pp.87-98
    • /
    • 1994
  • 연구배경 : 정신분열증 환자들이 정보처리 과정의 문제가 있을 것이라는 가설을 지지해 주는 사건관련유발 전위인 P3의 이상을 보고하는 연구들이 있어 저자들은 정신분열증 환자들에게 청각사건관련유발 전위를 실시하여 P3의 이상을 확인하고자 하였다. 또한, 음성 및 양성 정신분열증환자에 P3의 차이가 있는지 비교하였으며, 가족력이나 전기충격경련요법, 밖에 임상양상과 P3와의 연관성을 알아보기 위하여 본 연구를 실시하였다. 방법 : DSM-III-R 진단기준에 맞는 정신분열증 환자 54명 (남자 31, 여자 23) 과 그 대조군 75 명 (남자 33, 여자 42) 을 대상으로 oddball paradigm 을 이용한 사건관련유발전위를 실시하여 P3의 잠복기와 진폭을 측정하였으며, 정신분열증의 인지기능이상을 알아볼 수 있는 프랑크푸르트 임상검사를 같이 실시하였다. 결과 : 정신분열증 환자의 P3 잠복기는 그 대조군에 비해 의미 있게 지연되어 있었으며, 또한 모든 진폭도 대조군에 비해 의미 있게 감소되어 있었다. 정신분열증 환자군에서 프랑크푸르트 임상검사의 10가지 임상증상 모두에서 통계적으로 유의하게 높은 점수를 보였다. PANSS의 종합점수에 따라 음성과 양성으로 나누어 비교한 결과, P3의 잠복기 및 진폭에서 의미 있는 차이가 발견되지 않았다. 또한, 정신과질환의 가족력의 유무에 따라, 전기 충격경련요법 유무에 따라 비교한 결과 의미 있는 차이를 발견할 수 없었다. 환자군에서 프랑크푸르트 임상검사의 임상증상, 그밖에 임상특성과 P3의 잠복기와 진폭 사이에 연관성을 발견할 수 없었다. 결론 : 본 연구의 결과로 정신분열증 환자들에서 선택적 주의집중 과정의 이상이 있을 것이고 추측할 수 있었으며, 임상양상이나 가족력 유무와 P3사이에 연관성이 없다는 것을 시사해 주었다.

  • PDF

건강하고 젊은 성인에서 주파수 차이를 이용한 불일치음전위: 잠복기와 전위 (Mismatch Negativity Using Frequency Difference in Healthy Young Adults: Latency and Amplitude)

  • 정석원;김영수;양태원;김도형;김민수;배상현;김가인;권오영
    • 대한임상검사과학회지
    • /
    • 제52권3호
    • /
    • pp.194-201
    • /
    • 2020
  • 잠복기와 전위는 MMN의 측정 매개변수이다. 이 매개변수의 수치는 자극방안에 따라 민감하게 변한다. MMN 검사를 위해 주파수 차이를 자극변이로 이용하는 자극방안이 잘 알려져 있다. 이 자극방안을 이용하여 건강하고 젊은 성인에서 MMN 검사를 하고 매개변수의 참고치를 구하는 것이 본 연구의 목적이다. 저자들은 10명의 정상성인을 모집하였다. 이들의 연령은 평균 25.5세이고, 3명은 여성 7명은 남성이었다. MMN 검사를 위한 청각 자극방안에서 표준소리의 주파수는 1,000 Hz, 변이소리의 주파수는 1,032 Hz였다. MMN의 평균잠복기와 평균전위가 Fz에서 202 ms 와 1.88 ㎶, Cz에서 207 ms와 1.46 ㎶, C3에서 212 ms와 1.10 ㎶, 그리고 C4에서 214 ms와 1.45 ㎶였다. MMN의 잠복기와 전위사이에 상관성은 관찰되지 않았다. 본 연구는 적용하기 쉬운 표준자극방안으로 검사한 MMN의 잠복기와 전위의 참고치를 제시하였다. 이 정보는 임상과 기초연구에서 MMN의 유용성을 높일 것이다.

조현병 환자의 인지기능과 뇌 사건유발전위의 관계 (Cognitive Abilities and Auditory Event Related Potentials in Patients with Schizophrenia)

  • 김가영;민정아;채정호
    • 생물정신의학
    • /
    • 제19권3호
    • /
    • pp.115-120
    • /
    • 2012
  • Objectives : Event-related potentials have been suggested as an objective marker for brain functions in psychiatric disorders. This study was aimed to investigate the relationships between P300, the mismatch negativity (MMN), the loudness dependence of the auditory evoked potential (LDAEP), demographic and clinical variables including neurocognitive abilities in patients with schizophrenia. Methods : P300, the MMN, and the LDAEP were measured and the Korean Stroop color-word test (K-stroop test) and the Wisconsin Card Sorting Test (WCST) were performed in 43 patients with schizophrenia. The relationship of the latency and amplitude of P300 and the MMN as well as regression slope of the LDAEP with demographic and clinical variables were analyzed by t-test and correlation analyses for categorical and continuous variables, respectively. Results : After controlling for age, the latency of central (Cz) and parietal (Pz) P300 posivitively correlated with GAF at admission (Cz ; ${\gamma}$ = 0.385, p = 0.047, Pz ; ${\gamma}$ = 0.421, p = 0.029). The amplitude of parietal P300 correlated with the correction rate of the K-stroop test (${\gamma}$ = 0.575, p = 0.002). In addition, the frontal (Fz) P300 latency tended to negatively correlated with the correction rate of the WCST (${\gamma}$ = -0.371, p = 0.057). Conclusions : Our findings suggest that the values of P300 latency and amplitude might be correlated with GAF at admission and working memory measured by the K-Stroop test and the WCST. Meanwhile, the MMN and the LDAEP did not correlate with demographic and clinical variables. These results support the results of previous studies showing associations with P300 and impaired cognitive ability.