• Title/Summary/Keyword: Amplicor PCR

Search Result 7, Processing Time 0.018 seconds

Clinical Utility of Bronchial Washing PCR for IS6110 and Amplicor for the Rapid Diagnosis of Active Pulmonary Tuberculosis in Smear Negative Patients (객담도말 음성인 폐결핵환자의 기관지세척액에서 Amplicor PCR과 IS61110 PCR의 임상적 유용성에 관한 비교 연구)

  • Lee, Jun-Gu;Kim, Young-Sam;Park, Jae-Min;Ko, Won-Ki;Yang, Dong-Goo;Kim, Se-Kyu;Chang, Joon;Kim, Sung-Kyu;Choi, Jong-Rak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.2
    • /
    • pp.213-221
    • /
    • 2001
  • Background : There is a well recognized interlaboratory variation in the results using the polymerase chain reaction(PCR) to detect the IS6110 sequence. The clinical utility of a commercially developed PCR test(Amplicor) in bronchial washings for detecting pulmonary tuberculosis in smear negative patients was evaluated. The sensitivity and specificity of Amplicor was compared with that of an in-house PCR test used for detecting the IS6110 sequence of Mycobacterium tuberculosis(M.tbc) in the bronchial washing fluid. Methods : 66 patients whose sputum smear for M. tbc were negative or who could not produce any sputum were recruited from January 1999 to July 1999. They all had a bronchoscopy performed to determine if there were signs of hemoptysis, patients who could not cough up sputum, lung lesion that exclude pulmonary tuberculosis. Pulmonary tuberculosis was diagnosed on the basis of a positive culture or a response to anti-tuberculosis therapy. Results : 19 patients with tuberculosis were identified and samples from 16 patients were later confirmed by culture. Bronchial washing for Amplicor PCR revealed a sensitivity, specificity, positive and negative predictive values of 94.7%, 97.9%, 94.7%, 97.9%, respectively. Using IS6110 based PCR, the sensitivity, specificity, positive and negative predictive values were of 73.7%, 87.2%, 70%, 89.1% respectively. Conclusion : Bronchial washing for Amplicor PCR proved to be more useful than IS6110 based PCR in rapidly diagnosing smear negative pulmonary pulmoary tuberculosis in patients where tuberculosis was likely to be differential and rapid diagnosis was essential for optimal treatment.

  • PDF

Sensitivity of Polymerase Chain Reaction for Pleural Tuberculosis according to the Amount of Pleural Effusion Specimens (흉막 결핵의 진단에 있어서 흉수 검체양에 따른 중합효소연쇄반응 검사의 민감도)

  • Moon, Jin Wook
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.3
    • /
    • pp.184-191
    • /
    • 2007
  • Background: For the diagnosis of pleural tuberculosis, polymerase chain reaction (PCR) of pleural effusion specimens has shown very low sensitivity, which might be due to the small number of bacilli in the samples. The purpose of this investigation is to determine whether the sensitivity of PCR testing can be improved when increasing the amount of pleural effusion specimens. Methods: We prospectively analyzed pleural effusion specimens obtained from 53 patients for whom the exclusion of the possibility of tuberculous pleural effusion was necessary. We performed Mycobacterium tuberculosis PCR testing using the Cobas Amplicor MTB test (Roche Diagnostic Systems) with three different amounts (10ml, 25ml, and 50ml) of pleural effusion specimen in each patient. Pleural tuberculosis was defined as having one of the following: culture-positive pleural fluid sample, histopathologic finding consistent with tuberculosis on pleural biopsy, culture-positive sputum specimen, and/or positive response to anti-tuberculous medication without other possible causes of pleural effusion. Results: Of the 53 patients, 26 received the diagnosis of pleural tuberculosis. The sensitivities of AFB smearing, Mycobacterium tuberculosis culture of pleural effusion specimen, pleural biopsy, and measurement of ADA were 3.8%, 15.4%, 84.6%, and 88.5%, respectively. The results of PCR testing were positive for 3 (11.5%), 4 (15.4%), and 3 (11.5%) of the 26 patients when using 10ml, 25ml, and 50ml of pleural effusion specimens, respectively. These results did not show a statistically significant difference in the sensitivity of PCR testing when increasing the amount of pleural effusion samples (p>0.05, symmetry exact test). Conclusion: For specimens such as pleural effusion, in which the bacillary load is very low, the clinical utility of PCR testing seems highly limited with the kits designed for the diagnosis of pulmonary tuberculosis. An increased amount of pleural effusion sample does not improve the sensitivity of PCR testing.

A Nucleic Acid Amplification Tests for Reliable HCV RNA Detection Method for Plasma-Derived Products (핵산증폭시험을 이용한 혈장분획물질에서 HCV RNA 검출)

  • Hong, Seung-Hee
    • Korean Journal of Microbiology
    • /
    • v.44 no.4
    • /
    • pp.293-298
    • /
    • 2008
  • HCV is transmitted via various plasma derived products. Current methods to detect hepatitis C virus (HCV) are based on its antibody detection in the donated blood and plasma. Viral contamination can potentially escape such detection during the window period of infection, when no antibody is present or the level of antibody is too low to detect. It is trying to application of nucleic acid amplification tests (NAT) for the direct detection of HCV. The objective of this study was to develop a reliable NAT for the HCV RNA detection from plasma-derived products. The most useful primers was selected for NAT among 5 sets of primers. We have also found that QIAamp viral RNA isolation kit was the most efficient for HCV RNA isolation. The highest sensitivity and specificity was appeared in $48^{\circ}C$ annealing temperature and 30 pmol of primers. With a spiking of HCV to albumin, immunoglobulins and coagulation factors, NAT can detect up to 100 IU/ml. Meanwhile, COBAS amplicor HCV 2.0 afforded a lower sensitivity in high concentrated intramuscular immunoglobulins to below 500 IU/ml. Our results suggested that NAT appears to be a highly sensitive and specific method for HCV RNA detection in plasma-derived products.

Comparison of Acid-Fast Staining, PCR, LCR, PCR-Hybridization for Detection of Mycobacterum Tuberculosis in Clinical Specimens (임상 검체에서 결핵균 검출을 위한 항산성염색, PCR, LCR, PCR-Hybridization 검사법 간의 비교)

  • Choi, Jong-Rak;Lim, Jong-Baeck;Kim, Hyung-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.3
    • /
    • pp.281-289
    • /
    • 2000
  • Background : Mycobacterial culture is a confirmatory test to detect. M. tuberculosis, but it takes at least 6 weeks to diagnose. PCR is a rapid and sensitive method, but it is known that PCR has a high false positive rate due to contamination, and a high false negative rate due to inhibitors. It is also known that LCR and PCR-Hybridization, recently developed methods, are more specific methods than PCR in terms of detecting M. tuberculosis. In this study, we estimated the clinical utility of in house PCR, LCR and PCR-Hybridization for the detection of M. tuberculosis. Methods : We evaluated 75 specimens, upon which M. tuberculosis culture based testing was requested, by PCR LCR, and PCR-Hybridization and compared results. Mycobacterial culture was performed on 3% Ogawa media for 8 weeks, and an in house PCR, LCx Mycobacterium tuberculosis assay kit (Abbott Laboratories, North Chicago, III) and the AMPLICOR M. tuberculosis test kit (Roche Molecular Systems, Inc. Branchburg, NJ. USA). Results : In the view of the culture results, the sensitivities of the three tests were 40%, 80%, and 100% and their specificities were 98.6%, 94.3%, and 94.3%. Conclusion : LCR and PCR-Hybridization are rapid and sensitive methods for detecting M. tuberculosis in clinical laboratories.

  • PDF

Usefulness of Automated PCR Test for the Detection of Mycobacterium Tuberculosis in Fresh Biopsy Tissues (신선조직 검체에서 결핵균 검출을 위한 자동화 중합효소연쇄반응 검사의 유용성)

  • Choi, Woo Soon;Shin, So Young;Kim, Jong Ok;Kim, Myung Sook;Lee, Hye Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.54-59
    • /
    • 2006
  • Background: Although there have been several studies regarding the clinical value of an automated TB-PCR study using sputum, bronchial washing, and other body fluid samples for the detection of pulmonary tuberculosis, there are only a few reports on the use of fresh tissue samples. Materials and methods: The acid-fast bacilli stain(AFB), tuberculosis culture, automated TB-PCR study, and histopathology examination were performed in 42 fresh tissue samples. Results: Among the 42 cases, 18 cases were diagnosed with tuberculosis based on the clinical findings. Sixteen of the 18 cases were TB-PCR positive and of these 16 cases, only 2 cases were positive in the AFB stain or culture study. However, all 18 cases showed the histopathology findings of chronic granulomatous inflammation that was compatible with tuberculosis. Based on the clinical findings, the sensitivity, specificity, positive predictability, and negative predictability of the automated TB-PCR study were 88.9%, 100%, 100%, and 92.3% respectively. Conclusion: An automated TB-PCR assay is an important diagnostic tool for diagnosing tuberculosis in fresh tissue samples.

Validation of One-Step Real-Time RT-PCR Assay in Combination with Automated RNA Extraction for Rapid Detection and Quantitation of Hepatitis C Virus RNA for Routine Testing in Clinical Specimens

  • KIM BYOUNG-GUK;JEONG HYE-SUNG;BAEK SUN-YOUNG;SHIN JIN-HO;KIM JAE-OK;MIN KYUNG-IL;RYU SEUNG-REL;MIN BOK-SOON;KIM DO-KEUN;JEONG YONG-SEOK;PARK SUE-NIE
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.3
    • /
    • pp.595-602
    • /
    • 2005
  • A one-step real-time quantitative RT-PCR assay in combination with automated RNA extraction was evaluated for routine testing of HCV RNA in the laboratory. Specific primers and probes were developed to detect 302 bp on 5'-UTR of HCV RNA. The assay was able to quantitate a dynamic linear range of $10^7-10^1$ HCV RNA copies/reaction ($R^2=0.997$). The synthetic HCV RNA standard of $1.84{\pm}0.1\;(mean{\pm}SD)$ copies developed in this study corresponded to 1 international unit (IU) of WHO International Standard for HCV RNA (96/790 I). The detection limit of the assay was 3 RNA copies/reaction (81 IU/ml) in plasma samples. The assay was comparable to the Amplicor HCV Monitor (Monitor) assay with correlation coefficient r=0.985, but was more sensitive than the Monitor assay. The assay could be completed within 3 h from RNA extraction to detection and data analysis for up to 32 samples. It allowed rapid RNA extraction, detection, and quantitation of HCV RNA in plasma samples. The method provided sufficient sensitivity and reproducibility and proved to be fast and labor-saving, so that it was suitable for high throughput HCV RNA test.

Clinical Utility of Polymerase Chain Reaction for the Differentiation of Nontuberculous Mycobacteria in Patients with Acid-fast Bacilli Smear-positive Specimens (객담 항산균 도말 양성 환자에서 비결핵항산균과의 감별을 위한 결핵균 중합효소연쇄반응 검사의 유용성)

  • Lee, Jae Seung;Ji, Hyun Shuk;Hong, Sang Bum;Oh, Yeon-Mok;Lim, Chae-Man;Lee, Sang Do;Koh, Younsuck;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Shim, Tae Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.5
    • /
    • pp.452-458
    • /
    • 2005
  • Background : In Korea, polymerase chain reaction (PCR) test for M. tuberculosis has been used for the diagnosis of acid-fast bacilli (AFB) smear-negative tuberculosis in order to increase diagnostic sensitivity. However, there have been no data dealing with the clinical utility of PCR in AFB smear-positive patients to differentiate between M. tuberculosis and nontuberculous mycobacteria. Method : We retrospectively analyzed the PCR test results which have been performed in patients who had AFB smear-positive sputum but had ambiguous clinical manifestations of active tuberculosis. PCR test was done using $AMPLICOR^{\hat{a}}$ M. tuberculosis kit. The sensitivity, specificity, and positive and negative predictive values of the PCR test were calculated based on culture and final clinical diagnosis result. Results : Fifty-six consecutive patients (62 PCR tests) were included in the study. Active tuberculosis was diagnosed in 23 patients (41.0%), while 9 patients had NTM infection (16.0%). The sensitivity, specificity, positive- and negative-predictive value of PCR test were 88.8%, 86.8%, 76.1% and 94.3%, respectively, according to the culture result. In comparison, they were 91.3%, 100%, 100%, 94.3%, respectively, according to the final clinical diagnosis. All 15 patients with NTM isolates, including 6 patients who had other lung diseases but expectorated NTM isolate, were negative for PCR test. Conclusion : Even though tuberculosis is still prevalent in Korea, PCR test is useful to differentiate between M. tuberculosis and NTM in patients with AFB-smear positive sputum but with ambiguous clinical manifestations of active tuberculosis.