• Title/Summary/Keyword: Amount of water evaporation

Search Result 141, Processing Time 0.028 seconds

Establishing the Models for Optimized Design of Water Injection in Boilers with Waste-heat-recovery System (가습연소 폐열회수 보일러의 물분사 설계모델 구축에 관한 연구)

  • Shin, Jaehun;Moon, Seoksu
    • Journal of ILASS-Korea
    • /
    • v.26 no.2
    • /
    • pp.96-103
    • /
    • 2021
  • In order to improve the overall efficiency and meet the emission regulations of boiler systems, the heat exchanging methods between inlet air and exhaust gas have been used in boiler systems, named as the waste-heat-recovery condensing boiler. Recently, to further improve the overall efficiency and to reduce the NOx emission simultaneously, the concept of the water injection into the inlet air is introduced. This study suggests the models for the optimized design parameters of water injection for waste-heat-recovery condensing boilers and performs the analysis regarding the water injection amount and droplet sizes for the optimized water injection. At first, the required amount of the water injection was estimated based on the 1st law of thermodynamics under the assumption of complete evaporation of the injected water. The result showed that the higher the inlet air and exhaust gas temperature into the heat exchanger, the larger the amount of injected water is needed. Then two droplet evaporation models were proposed to analyze the required droplet size of water injection for full evaporation of injected water: one is the evaporation model of droplet in the inlet air and the other is that on the wall of heat exchanger. Based on the results of two models, the maximum allowable droplet sizes of water injection were estimated in various boiler operating conditions with respect to the residence time of the inlet air in the heat exchanger.

Effects of Evaporation Water Flow Rate on the Performance of an Indirect Evaporative Cooler (증발수 유량이 간접 증발식 냉각기 성능에 미치는 영향)

  • Choo, Hyun-Seon;Lee, Kwan-Soo;Lee, Dea-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.714-721
    • /
    • 2006
  • In evaporative cooling applications, the evaporation water is supplied usually sufficiently larger than the amount evaporated to enlarge contact surface between the water and the air. Especially in indirect evaporative coolers, however, if the evaporation water flow rate is excessively large, the evaporative cooling effect is not used for heat absorption from the hot fluid but spent to the sensible cooling of the evaporation water itself. This would result in a decrease in the cooling performance of the indirect evaporative cooler. In this study, the effects of the evaporation water flow rate on the cooling performance are investigated theoretically. The cooling process in an indirect evaporative cooler is modeled into a set of linear differential equations and solved to obtain the exact solutions to the temperatures of the hot fluid, the moist air, and the evaporation water. Based on the exact solutions, it is analyzed how much the cooling performance is affected by the evaporation water flow rate. The results show that the decrease in the cooling effectiveness is substantial even for a small flow rate of the evaporation water and the relative decrease is more serious for a high-performance evaporative cooler.

Short-term Variation in Class A Pan Evaporation (대형증발계 증발량의 일 변화)

  • 이부용
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.4
    • /
    • pp.197-202
    • /
    • 2002
  • A new method is used to estimate the amount of water evaporation from Class A Pan with higher precision and accuracy. The principle of method is to detect the weight change of a buoyant sinker resulting from a change in water level of Class A Pan. A strain-gauge load cell is used to measure the weight change. Field observation of evaporation was done at Pohang Meteorological Station from June 24 to August 4, 2002. By using this new method, it is possible to measure hourly evaporation accurately even under a strong solar radiation and wind disturbance, enabling a direct comparison of evaporation with other meteorological elements. At night, under low humidity and high wind speed conditions, more evaporation was recorded than during daytime. Maximum evaporation rates observed during this period exceed 1.0 mm/hour under the sunny and windy conditions with low humidity. To understand relationships between meteorological elements and latent heat flux at ground level, we suggest intensive held experiments using high accuracy evaporation recording instruments with hourly time interval.

A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan (대형증발계용 매시간 증발 기록계 개발에 관한 연구)

  • Bu-Yong Lee
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF

Fundamental study on the evapo-transpiration requirements of paddy rice plant (수도용수량계획상의 엽면증발량 및 주간수면증발량에 관한 기초적인 연구)

  • 김철기
    • Journal of the Korean Professional Engineers Association
    • /
    • v.2 no.6_7
    • /
    • pp.12-23
    • /
    • 1969
  • The purpose of this study is to find out the reasonable amount of evapo-transpiration required for the paddy rice plant during the whole growing season. So, on the basis of the 3year experimental data concerning the evapo-transpiration from 1966 to 1968, the author obtained the following results. 1) The leaf area index in the densely planted plot is generally higher than that in the conventionally planted one during the first half of growing season. So, the coefficient of transpiration in the former plot is some what higher than in the latter, and the coefficient of water surface evaporation under the plant cover has the inverse relation between both plots. 2) It is unreasonable that coefficient of evapo-transpiration is applied to the calculation of the evapo-transpiration requirments of each growing stage, because a certain degree of variation in meteorological factors and in the thickness of the plant growth is involved in it. 3) It is most reasonable that the rate of transpiration and of the water surface evaporation is applied to the calculation of the transpirated amount and evaporated one in each growing stage because it shows almost constant value in spite of any meteorological conditions in so far as the variety of rice, planted density and control of applying fertilizer are same and the disease and blight are negligible. 4) The ratio of the amount of transpiration to the weight of the whole air dried yields has the tendency of decreasing as that of the yields increase, having almost constant value despite the amount of pan evaporation; and the value is about 210 when the weight of root parts is included to that of the yields. 5) Although the required amount of transpiration during the whole growing season can be calculated with the above ratio, fig. 7 showing the relation between the amount of transpiration and the weight of the yields is more reasonable and will be convinient to find it. And the requirements of water surface evaporation during the same season can also be directly found with the weight of air dried straw refering to fig.8.

  • PDF

A Study on the Estimation of Zoysia matrella's Evaporation Using Makkink Model (인공지반에서 금잔디의 증발산량 예측에 관한 연구 -퍼라이트 배합토에서 Makkink의 일사법을 이용하여-)

  • 김도경;황지환
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.29 no.1
    • /
    • pp.161-167
    • /
    • 2001
  • The purpose of this study is to find out the difference of Zoysia matrella's evaporation in between 100 percent soil and mixed soil with 50 percent of perlite to create green spaces on the artificial ground. It is believed that the weight against the artificial ground will be reduced, provided the vegetation is possible in the circumstance of the mixed sol with 50 percent of perlite. The study employed a modified Makkink's model by Iwasa who had developed the model for estimating Zoysia matrella's evaporation in the natural ground using the Makkink's formula in 1997 at Chiba University, Japan. The parameter of Makkink's formula is the solar radiation. For that reason, the Makkink's formula is simple and easy to measure the parameter and has a high utility. If the outcomes from mixed soil are close to modified Makkinks formula, the modified Makkink's formula will be applied to estimate in the artificial ground with mixed soil with 50 percent of perlite. Weather observation and actual amount of evaporation of Zoysia matrella have been measured, and the relation between weather condition and actual amount of evaporation had been also investigated. In line with this, we found out that there is a relevant relationship between daily average temperature, the modified Makkink's model by Iwasa, and the actual amount of evaporation. As the results of the experiment, the outcomes from mixed soil with 50 percent of perlite have very high relation to 100 percent soil. In addition, mixed soil has more adhesion with water than natural soil. However, it needs to be adequately maintained in terms of fertilization and damage from disease and harmful insects until the gras fastens its roots into the soil. By using mixed soil with 50 percent of perlite, the load from soil on the artificial ground can be reduced. The study on the growth of the grass throughout the plant vegetation and the actual amount of evaporation in the mixed soil with 50 percent of perlite should be performed in the future.

  • PDF

Experimental Validation on Performance of Waste-heat-recovery Boiler with Water Injection (물분사 폐열회수 보일러의 효용성에 대한 실험적 검증)

  • Jaehun Shin;Taejoon Park;Hyunseok Cho;Junsang Yoo;Seoksu Moon;Changeon Lee
    • Journal of ILASS-Korea
    • /
    • v.28 no.1
    • /
    • pp.43-48
    • /
    • 2023
  • The waste-heat-recovery boiler with water spray (HR-B/WS) applies the heat exchange between the inlet air and exhaust gas with the water spray into the inlet air. The evaporation of water in the inlet air promotes heat recovery from the exhaust gas so that thermal efficiency can be improved by the enhanced condensing effect. The NOx emission can also be reduced by lowering the flame temperature due to the dilution effect of the water. In this study, the validity of this concept is examined by the practical boiler test performed with a 24 kW condensing boiler under the full load condition according to the water injection amount. The theoretical amount of water injection is calculated under the assumption of full evaporation of the sprayed water, which is calculated as 50 g/min. Since the injected water cannot evaporate fully in the actual system, the maximum water spray amount is set as 100 g/min. The results showed that the water injection can increase the thermal efficiency up to 95.59% and reduce NOx and CO emissions simultaneously to 8.9 ppm and 35 ppm at 0% of O2. Although the heat energy loss increased due to the unevaporated water, the increase in water injection amount caused higher thermal efficiency due to the increased amount of the evaporated water.

A Fundamental Study for The Possibility of Charcoal as Green Infrastructure Materials

  • Choi, Jaehyuck;Shin, Soo-Jeong;Kim, Byung-Ro
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.691-699
    • /
    • 2015
  • To evaluate the possibility of charcoal as Green Infrastructure (GI) materials, data such as moisture content, amount of adsorbed water, and amount of evaporation were collected. Some data from previous study were referenced to find out if correlations exist between results in this study and previous study. Only porosity was directly related to moisture content. Two mechanical charcoal had better abilities than traditional charcoal in all three categories. Mechanical black charcoal chips produced by National Forestry Cooperative Federation (NFCFC) adsorbed 333.3% of water in thirty minutes, 297.5% in five minutes, and evaporated around 75% water in four days. This ability is much higher than other five charcoal. Even though results of test showed various degrees and NFCFC was the best as GI materials, data of charcoal were also within acceptable range based on generally accepted characteristics of GI materials.

Evaluation of Passive Cooling Effect on Roof Pond through Field Observation (관측에 의한 옥상 수공간의 자연냉각효과 평가)

  • Jeong, Seong-Jin;Choi, Dong-Ho;Lee, Bu-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.11a
    • /
    • pp.85-89
    • /
    • 2008
  • This study carried out field observations of measuring thermal environment, especially evaluating amount of water evaporation at roof Pond by field observations during the summer. Thermal environment measuring was categorized as air temperature, water temperature of roof pond, surface temperature, globe temperature, short and long wave radiation, net radiation, and amount of water evaporation by water level measurement. Results from this study could be used as fundamental for reducing heat Island phenomena.

  • PDF

Comparison of the Ion-exchange Method and Evaporation Method for the Detection of Radioactivity in Water (수중 방사능 측정시 이온교환농축법과 증발건조법의 비교)

  • Ji, Pyung-Gook;Park, Chong-Mook;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.52-56
    • /
    • 1988
  • An ion-exchange method for the detection of radioactivity in water using ion-exchange resin in concentrating radioactive nuclides was compared with an evaporation method. The loss of the radioactive materials in the sample treated by the ion-exchange method was less by about 20% than that by the evaporation method. In addition, the evaporation method needed about 20 hours for evaporating one liter of the sample at $70^{\circ}C$, while the ion-exchange method spent 6 hours to adsorb and adsorb the same amount of the sample on the resin. Consequently, the ion-exchange method is more effective than the evaporation method for the treatment of the radioactively contaminated water and is especially suitable for detecting the low-level radioactivity in water.

  • PDF