• Title/Summary/Keyword: Amount of horizontal solar radiation

Search Result 17, Processing Time 0.026 seconds

Comparative analysis of the global solar horizontal irradiation in typical meteorological data (표준기상데이터의 일사량 데이터 비교 분석)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Kang, Hyun-Gu
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.102-109
    • /
    • 2009
  • The research on meteorological data in Korea has been carried out but without much consistency and has been limited to some areas only. Of relatively more importance has been the area in the utilization of the solar energy, however, the measurement of the global solar horizontal irradiation has been quite limited. In the current study, the actually measured value of the global solar horizontal irradiation from the meteorological data and the theoretically calculated value of the global solar horizontal irradiation from the cloud amount will be analyzed comparatively. The method of analysis will employ the standard meteorological data drafted by the Korean Solar Energy Society, the standard meteorological data from the presently used simulation program and the corresponding results have been compared with the calculated value of the global solar horizontal irradiation from the cloud amount. The results of comparing the values obtained from MBE(Mean Bias Error), RMSE(Root Mean Squares for Error), t-Statistic methods and those from each of the standard meteorological data show that the actually measured value of the meteorological data which have been converted into standard meteorological data with the help of the ISO TRY method give the monthly average value of the global solar horizontal irradiation. These values compared with the monthly average value from the IWEC from the Department of Energy of the USA show that the value of the global solar horizontal irradiation in the USA is quite similar. In the case of the values obtained from calculation from the cloud amount, the weather data provided by TRNSYS, except only slight difference, which means that the actually measured values of the global solar horizontal irradiation are significant. This goes to show that in the case of Korea, the value of the global solar horizontal irradiation provided by the Korea Meteorological Administration is will be deemed correct.

Generation of monthly averaged horizontal Radiation based on a regional clearness estimating model (우리나라 지역별 청명도 예측 모델을 이용한 월평균 수평면 일사량 산출)

  • Kim, Jin-Hyo;Kim, Min-Hwi;Kwon, Oh-Hyun;Seok, Yoon-Jin;Jeong, Jae-Weon
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.72-80
    • /
    • 2010
  • The main thrust of this paper is to investigate a practical way of generating the monthly averaged daily horizontal solar radiation in Korea. For estimating the horizontal solar radiation, the clearness index($K_T$) and the clearness number($C_N$) which are required for the use of Liu and Jordan's model and ASHRAE Clear Sky model were derived based on the measured weather data. Third-order polynomials returning $K_T$ and��$C_N$ for a given location were derived as a function of cloud amount, month, date, latitude and longitude. The predicted monthly averaged daily horizontal solar radiation values were compared with those acquired from the established design weather data. The MBE(Mean Bias Error) and RMSE (Root Mean Squares for Error) between the predicted values and the measured data were near zero. It means that the suggested third-order polynomials for $K_T$ and $C_N$ have good applicability to Liu and Jordan's model and ASHRAE Clear Sky model.

Calculation of Solar radiation based on Cloud Data for Major cities of Korea (국내 주요도시의 운량데이터를 이용한 일사산출)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Park, So-Hee
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.142-147
    • /
    • 2008
  • Limited fossil fuels and unstable energy supply are considered as one of the critical problems in architecture requiring large amounts of energy. In order to this challenge, environment-friendly architecture design is required. Especially, Application of solar energy as a clean energy source and one kind of renewable energy. Many sites however are mainly concentrated in the developed countries, and are scarcer within the developing world. Simple radiation estimation models using meteorologically observed input parameters are often used in the applications requiring rough estimations of solar radiation. In this paper, measurements of global solar radiation and cloud data hours in climatological locations in South Korea are used to develop an estimation in solar radiation. The results of measured data are compared with the results obtained from equations, internationally accepted correlations.

  • PDF

Analysis of Maximum Solar Radiation on Inclined Surfaces for the Installation of Solar Thermal Systems in Korea Using the Optimum Installation Angle (국내 태양열시스템 설치를 위한 시스템 최적 설치각 산출을 통한 최대 경사면일사량 분석)

  • Jo, Dok-Ki;Kang, Young-Heack
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.47-54
    • /
    • 2009
  • The amount of incident rays over inclination according to direction has been widely utilized as important data m installing solar thermal systems. To optimize the incident solar radiation, the slope, that is the angle between the plane surface in question and the horizontal, and the solar azimuth angles are needed for these solar thermal systems. This is because the performance of the solar thermal systems in much affected by angle and direction of incident rays. Recognizing that factors mentioned above are of importance, actual experiment on the moving route of the sun have been performed in this research to obtain the angle of inclination with which the maximum incident rays can be absorbed. After all, the standard for designing highly optimized solar thermal systems will be provided for designers and employees working in the solar collector related industries.

Analysis of Maximum Solar Radiation on Inclined Surfaces in Korea (국내 최대 경사면일사량 분석)

  • Jo, Dok-Ki;Yun, Chang-Yeol;Kim, Kwang-Deuk;Kang, Young-Heack
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.3-7
    • /
    • 2009
  • The amount of incident rays over inclination according to direction has been widely utilized as important data in installing solar thermal systems. To optimize the incident solar radiation, the slope, that is the angle between the plane surface in question and the horizontal, and the solar azimuth angles are needed for these solar thermal systems. This is because the performance of the solar thermal systems in much affected by angle and direction of incident rays. Recognizing that factors mentioned above are of importance, actual experiment on the moving route of the sun have been performed in this research to obtain the angle of inclination with which the maximum incident rays can be absorbed. After all, the standard for designing highly optimized solar thermal systems will be provided for designers and employees working in the solar collector related industries.

  • PDF

Performance Analysis of Photovoltaic System for Greenhouse (태양광 발전시스템의 발전 성능 분석)

  • Kwon, Sun-Ju;Min, Young-Bong;Choi, Jin-Sik;Yoon, Yong-Cheol
    • Journal of agriculture & life science
    • /
    • v.46 no.5
    • /
    • pp.143-152
    • /
    • 2012
  • This study was performed to reduce the operating cost of a greenhouse by securing electric energy required for greenhouse operation. Therefore, it experimentally reviewed the performance analysis of photovoltaic system in terms of maximum amount of generated electric power based on the amount of horizontal solar radiation during daytime. That is to say, the maximum solar radiation at 300, 400, 500, 600, 700, 800 and 900 W. $m^{-2}$, respectively. The amount of momentary electric power of the photovoltaic system at any was about 970 W and we found that the momentary efficiency of the photovoltaic system that was used for this experiment was 97%. In the case of this system, we found that electric power will be generated when amount of horizontal solar radiation is more than 200 W. $m^{-2}$, at minimum. If the amount of horizontal solar radiation is increased, the maximum power generation is also increased. At that time, the maximum efficiencies were 30, 78, 86 and 90%, respectively. However, when the amount of insolation was about 800 W. $m^{-2}$, the maximum power generation tended to be lower than 700 W. $m^{-2}$. The efficiency which caused the maximum electric power was decreased to less than 97% of the momentary generated electric power. When the total amounts of horizontal solar radiation per day were 3.24, 8.10, 10, 90, 12.70, 14.33, 19.53 and $21.48MJ{\cdot}m^{-2}$ respectively, the total amounts of power energy were 0.03, 0.40, 3.60, 4.37, 4.71, 4.70 and 4.91 kWh. And it represented that the total amounts of power energy were either decreased or increased a bit on the border between some solar radiations. The temperature at the back of the array tended to be higher than the temperature at the front but it demonstrated an increased when the amount of solar radiation increased. In the case of this system, the performance of the module in terms of degradation has not been shown yet.

A Study on the Optimum Selection of Placing Photovoltaic Module In the Metropolitan City Using a TRNSYS (TRNSYS를 이용한 지역별 고정형 태양광모듈 배치안 검토)

  • Park, Sung-Hyun;Seo, Jang-Hoo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.297-302
    • /
    • 2011
  • In this study, used Trnsys and will apply metropolitan city distinguishes, fixations and BIPV systems the photovoltaic module arrangement environment which receives solar radiation quantity plentifully from the case design process which and most the outcome value simulation did analyzed. The climate data uses each metropolitan city distinguishes 20 average weather data, With measured values of horizontal solar radiation. The error scope appeared with 0.1%~6.7%. Variable of module arrangement Azimuth and angle of inclination of module and comparison group Module on due south direction angle of inclination $45^{\circ}$ day time set with the yearly average solar radiation quantity which receives. The result When the case comparison group which arranges a solar storehouse module with optimum environment and comparing until the minimum 1.4% - maximum 10.9% the solar radiation quantity difference appears with the thing, metropolitan city distinguishes considers the case solar radiation quantity which will arrange a photovoltaic module and that must establish with optimum environment judges.

  • PDF

Analysis of Solar Radiation on Inclined Surfaces with various Directions for the Installation of Solar Thermal Systems (태양열시스템 설치를 위한 방위별 경사면일사량 분석)

  • Jo, Dok-Ki;Kang, Young-Heak
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.171-173
    • /
    • 2008
  • The amount of incident solar rays on inclined surfaces with various directions has been widely utilized as important data in installing solar collector, hot water system, and designing solar buildings and house. This is because the performance of the solar energy applied systems is much affected by angle and direction of incident rays. Recognizing those factors mentioned above are of importance, actual experiment has been performed in this research to obtain the angle of inclination with which the maximum incident rays can be absorbed. The results obtained in this research could be used in designing optimal solar thermal systems.

  • PDF

Analysis of Data and Calculation of Global Solar Radiation based on Cloud Data for Major Cities in Korea (국내 주요도시의 운량데이터를 이용한 전일사 산출 및 비교)

  • Yoo, Ho-Chun;Lee, Kwan-Ho;Park, So-Hee
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.17-24
    • /
    • 2008
  • Estimation of typical solar radiation is very important for the calculations concerning many solar applications. But solar radiation measurements are not easily available because of the expensive measuring equipment and techniques required. Accordingly, for regions where no solar radiation is measured, solar radiation need to be estimated using other meteorological data. However, currently in Korea, there is no study on how to do this. In this paper, the global radiation of the six major cities in South Korea where the global radiation is measured using comparatively simple CRM model was calculated compared and analyzed. The comparison between the original coefficient and the site-fitted coefficient for these cities are as follows. Differences between the site-fitted coefficient and the original coefficient for six cities are small. Except for Gwangju, both calculations show strong correlation. In case of Seoul, the $R^2$(coefficient of determination) were 0.747 and 0.749. In case of Busan and Daegu the figures were 0.817, 0.819 and 0.820, 0.821 respectively. For Gwangju, these were 0.618 and 0.622, Thus, the site-fitted coefficients were slightly higher for these four cities. On the other hand, Daejeon and Incheon was reported 0.773, 0.772 and 0.785, 0.783, respectively.

Correlation Analysis between solar power generation and weather variables (태양광 발전량과 기상변수간 상관관계 분석)

  • Yoo, Hyun-jae;Gong, Seung-jun;Kim, Jong-min
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.704-706
    • /
    • 2022
  • In this study, we analyzed the correlation between the amount of photovoltaic power generation and the factors of meteorological changes. A total of 52,561 data were used in the correlation analysis from January 2018 to January 2020, and the variables used in the correlation analysis were time, horizontal plane scattering solar radiation, direct solar radiation, wind velocity, and relative humidity. The temperature was used. Based on this data, we used the Google Colab platform to analyze the correlation, and the analysis revealed whether there was a correlation between solar power and meteorological change factors.

  • PDF