제습기능을 구비한 열펌프의 성능개선에 관한 연구 (A Study on the Performance Improvement of a Heat Pump System with a Dehumidification Function)

  • 고광수;김태형;박윤철
    • 설비공학논문집
    • /
    • 제26권11호
    • /
    • pp.529-534
    • /
    • 2014
  • This research developed a hybrid heat pump system with the functions of dehumidification and heating, which uses simulated air that is like underground air, from an environmental chamber as a heat source. The system consisted of three evaporators and three condensers that were installed in series in the air passage, between the underground and load space. As results, the total amount of dehumidification was 2.726 kg/h, and the heating $COP_h$ was 1.84 at air intake temperature $17^{\circ}C$ and relative humidity 70%, which is a similar condition to underground air. We found that the total amount of dehumidification also increased with the air temperature and humidity. The system $COP_s$ was reached at 2.5, if we include the latent heat of dehumidification in the conventional heat pump system's COP.

Indoor air quality evaluation in intercity buses in real time traffic

  • Kazim O. Demirarslan;Serden, Basak
    • Advances in environmental research
    • /
    • 제11권1호
    • /
    • pp.17-30
    • /
    • 2022
  • Road transport allows all forms of land conditions to be met at less cost. Because of this function, despite numerous disadvantages, it becomes the most frequently used method of transport, especially in underdeveloped or developing countries. One of the most significant factors used in evaluating the atmosphere's air quality is the amount of CO2, increasing people's density in indoor spaces. The amount of CO2 indoors is, therefore, vital to determine. In this study, CO2 and temperature measurements made on nine different bus journey was made in Turkey. The minimum and maximum values were recorded as 555 ppm and 3000 ppm CO2, respectively, in the measurements. On all journeys, the average concentration is 1088.72 ppm. The minimum and maximum values were measured as 17.4℃ and 32.7℃ in the temperature measurements, and the average of all trips was calculated to be 25.76℃. In this study conducted before the Covid-19 pandemic, it was determined that the amount of CO2 increased with the density and insufficient ventilation in the buses. The risk of infection increases in places with high human density and low clean air. For situations such as pandemics, CO2 measurement is a rapid indicator of determining human density.

활성탄관법을 이용한 공기중 이황화탄소 농도 측정법에 관한 연구 (Evaluation of the Charcoal Tube Sampling Method for Carbon Disulfide in Air)

  • 이나루;백남원
    • 한국산업보건학회지
    • /
    • 제3권1호
    • /
    • pp.22-36
    • /
    • 1993
  • This study was conducted to evaluate the charcoal tube sampling method for carbon disulfide in the air. Breakthrough was investigated according to flow rate, sampling time and air volume. Also the storage stability by storage method and time was investigated. The results are summarized as follows. 1. The samples stored at room temperature($28.2^{\circ}C$), refrigerator($3.8^{\circ}C$) and freezer($-15.6^{\circ}C$) were analyzed every week to five weeks. At one week storage at room temperature, 3.5% of $CS_2$ in the front section of the charcoal tube migrated into the back section and 57.7% at five weeks. The amount of $CS_2$ in the back section of the charcoal increased continuously by storage time. Migration of $CS_2$ was slow at refrigerator, and stopped occur at freezer. Recovery rate $CS_2$ was 52-82% at room temperature and 92-101% at refrigerator, based on the amount at freezer as a reference value. Thus loss was observed at room temperature. 2. When 6-48 L of fresh air were passed through tubes with spiked amounts of 0.379 and 0.759mg sample, the amounts of $CS_2$ in the back section of charcoal were 5.7-132.4 and 0-92% of the amount in the front section, respectively. The total recovery rates of$CS_2$ from 0.379 and 0.759mg spiked sample were 35.7-101.0% and 9l.3-100.1%, respectively. $CS_2$ loss was observed in 0.379mg spiked sample, but not in 0.759mg spiked sample. In the spiked samples, the amount of $CS_2$ in the back section of charcoal was not affected by flow rate when the air volume was controlled. The amount of $CS_2$ in the back section of charcoal increased over sampling time. And the faster the flow rate, the more the migration amount when the sampling time was the same. 3. A known concentration, 10 ppm of $CS_2$, was produced in a 200 L Tedlar bag. When the air volume was 24, 36, 48 L, breakthrough was 5.8, 16.9, 47.4%, respectively. The sampling flow rate of 0.05, 0.1, 0.2 Lpm did not change the breakthrough rate. Breakthrough increased over sampling time. And the faster the flow rate, the more the breakthrough, when the sampling time was the same.

  • PDF

지열원 히트펌프 시스템에 적용되고 있는 난방용 적산열량계의 신뢰성 평가에 관한 연구 (A Study on the Reliability of District Heat Measuring Devices for Ground Source Heat Pump Systems)

  • 강희정;이현수;장명훈
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 2018
  • A ground source heat pump system should be equipped with devices to measure the generated heating or cooling heat amount in Korea. Generally, the heat measuring devices have been developed to estimate consumed heat amount in residential or commercial buildings from a central air-conditioning system or a district heating system. In this study, two representive heat measuring devices used for buildings were selected, and the accuracy of them were experimentally estimated at the ground source heat pump operating conditions. The obtained heat amounts from the heat measuring devices were deviated within 4.3% comparing with the precise values calculated from an accredited test facility. Even though the accumulated heat amount values of the heat measuring devices had a small difference comparing with the precise values, the temperatures of heat measuring devices showed greatly different values comparing with the precise temperature. Therefore, it is highly recommended to develop the heat measuring devices which is appropriate for the ground source heat pump systems.

지형적 특성을 고려한 우리나라의 농업기후지대 구분 (Classification of Agroclimatic Zones Considering the Topography Characteristics in South Korea)

  • 김용석;심교문;정명표;최인태;강기경
    • 한국기후변화학회지
    • /
    • 제7권4호
    • /
    • pp.507-512
    • /
    • 2016
  • This study was conducted to classify agroclimatic zones in South Korea. To classify the agroclimatic zones, such climatic factors as amount of rainfall from April to May, amount of rainfall in October, monthly average air temperature in January, monthly average air temperature from April to May, monthly average air temperature from April to September, monthly average air temperature from December to March, monthly minimum air temperature in January, monthly minimum air temperature from April to May, Warmth Index were considered as major influencing factors on the crop growth. Climatic factors were computed from monthly air temperature and precipitation of climatological normal year (1981~2010) at 1 km grid cell estimated from a geospatial climate interpolation method. The agroclimatic zones using k-means cluster analysis method were classified into 6 zones.

송풍 시스템의 공기유량측정 방법에 관한 연구 (Research on Air Flow Rate Test Method for Blower System)

  • 이준식
    • 한국산업융합학회 논문집
    • /
    • 제25권1호
    • /
    • pp.55-60
    • /
    • 2022
  • This study conducted the measurements of air flow rate for blower systems with experiment and numerical. A new airflow rate test method is suggested, with which it is possible to accurate measurements and calculate the air flow rate for blower systems. The blower(axial fan) is an industrial fluid machine device that supplies a large amount of air by driving an impeller with an electric motor, and it is widely used throughout the industry such as steel, power plant, chemical, semiconductor, LC D, food, and cement. The airflow from the blower is for exchanging the heat in the cooling unit or heat exchanger. The temperature of coolants and hydraulic oil primarily depends on the amount of airflow rate through the cooling package so its accurate estimation is very important. Moreover, it required a larger investment in time and cost since it could not be executed until the system is actually made. Therefore, this research is intended to examine the phenomenon of air flow pattern when testing air flow rate, suggested new test method, and show the result of the validation test.

탄소섬유 시트 방전극의 입자 크기 별 집진 특성 및 공기청정기로의 응용 (Particle collection characteristics of carbon fiber sheet discharge electrode by particle size and application to air cleaner)

  • 신동호;우창규;홍기정;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제14권3호
    • /
    • pp.81-88
    • /
    • 2018
  • The market for improving the indoor air quality is continuously increasing, and air cleaners are the representative products. As interest in indoor air quality increases, so are the ultrafine particle which are harmful to the human body. Despite its many advantages, electrostatic precipitators are less used in indoor air due to ozone production. In this study, the carbon fiber sheet was applied to the discharge electrode and compared with the conventional tungsten wire discharge electrode. The particle collection efficiency and the amount of ozone generation were measured for 10-100 nm particles. Furthermore, it was applied to commercial air purifier with electrostatic precipitator to compare particle removal performance. The carbon fiber sheet type discharge electrode generates a small amount of ozone, and thus it can be applied to improve indoor air quality.

항공기 배출가스가 대기환경에 미치는 영향 (Effect of Emission gas from Air craft to Ambient Air)

  • 신찬기
    • 환경위생공학
    • /
    • 제10권3호
    • /
    • pp.124-130
    • /
    • 1995
  • Air pollution problem by air craft was reviewed from emission gas components from air craft and pollutants amount generated in airport with the compareness of domestic transportation data by airplane and foreign data. It is reported that concentration of emission gas from air craft is lower than that of pollutants from automobile and factory. But transportation frequency is increasing rapidly in Korea. It is recommended that concerns should be taken on long- term of counterplan device about it.

  • PDF

고로쇠나무 수액의 출수에 미치는 영향 인자 분석 : (I) 광양지역 (Factors Affecting Acer mono sap Exudation : Kwangyang Region in Korea)

  • 최원실;박미진;이학주;최인규;강하영
    • Journal of the Korean Wood Science and Technology
    • /
    • 제38권1호
    • /
    • pp.66-74
    • /
    • 2010
  • 본 연구는 전라남도 광양시 백운산의 고로쇠나무 수액의 출수와 영향인자들을 분석하여 최적의 수액출수 조건을 얻고자 출수량, 고로쇠나무 흉고직경, 시험지의 기온과 상대습도를 2008년 1월 15일~3월 28일의 기간에 측정하여 출수량과 다른 측정값들과의 상관성 분석을 수행하였다. 수액 출수량은 고로쇠나무의 직경이 클수록 증가하였으며 출수에 필요한 최소 흉고직경은 17.1 cm로 분석되었고, 출수 시기는 직경별로 차이가 없었다. 수액 출수가 관찰될 때 일최저기온은 $-2.4{\pm}1.5^{\circ}C$, 그리고 일최고기온은 $6.0{\pm}1.8^{\circ}C$로 영상과 영하의 기온이 교차 하였고, 반면에 하루 종일 영상 혹은 영하의 기온을 유지시 출수가 관찰되지 아니하였다. 수액 출수량과 기온 및 대기습도와의 상관분석에서 수액출수량은 일최고기온, 일교차, 일최고습도, 일최저습도, 일평균습도에 유의성이 있었으며, 수액출수량과 일최고기온의 상관계수는 0.768 (P < 0.01)로 가장 높게 나타났다. 줄이들 인자들에 대한 편상관 분석결과 일최고기온이 주요 영향인자이었다. 수액 출수에는 일중 영하와 영상의 기온이 교차해야 하고 일최고기온이 높을수록, 그리고 고로쇠나무의 흉고직경이 클수록 출수량이 높았다.

사각 채널 내에서 열원이 부착된 수평 평판에서 자연대류의 수치해석 (A Numerical Analysis on the Natural Convect ion of the Square Channel inner from the Horizontal Plate with Protruding Heat Source)

  • 김병철;주동인
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.487-490
    • /
    • 2002
  • The real chip and similarity model were used to investigate the thermal behavior and velocity distribution of air from the heat source with the location and the amount of heat experimentally and numerically, and compared. The heat generated in the block is not cooled by convection and show the high temperature by the stagnation of heat flow. After maintaining the high temperature of block by the natural convection, the sudden drop of temperature with the air flow was shown in the channel but the decreasing rate was small with the time. The inward block was effected by infinitesimal air flow generated between block and channel and outward block was effected by the entry condition.