• 제목/요약/키워드: Amount of Circulation

검색결과 274건 처리시간 0.025초

양문형 냉장고 냉동실 결빙원인해석 및 최소화 방안 (Investigation on Freezing in the Freezing Compartment of a Side by Side Refrigerator)

  • 김윤규;정호윤;최윤환;이연원
    • 동력기계공학회지
    • /
    • 제14권1호
    • /
    • pp.34-39
    • /
    • 2010
  • A side by side refrigerator is popularly used one among electric home appliances according to the rise of the customer's living standard. But the frost problem in freezing compartment comes out whenever we develop the high quality refrigerator. In this research, internal flow simulation and temperature measurement were carried out by using CFD and T-type thermocouple respectively in order to understand freezing mechanism. It was revealed that the amount of frost beneath the 1st and 2nd shelves is approximately 40% of total frost and the cause of frost generation is due to bad circulation of low speed cold flow. Using this analysis, the shapes of outlets under shelves are modified. So, the amount of frost in this modified model decreases 6% comparing to original one.

선박배출 오염물질의 영향을 고려한 부산지역 대기질 모델의 개발 (The Development of Air Quality Model Considering Shipping Source in Pusan Region)

  • 이화운;김유근;원경미
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.135-144
    • /
    • 1999
  • Air quality modeling about coastal urban region such as Pusan shoud be consider shipping source emmited from ships anchoraging and running. It has been proved at our previous studies that the ratios of air pollutants emission amount in coastal area to inland are 12.2% for NO$_2$ and 11.7% for $SO_2$ and the air qualify of coastal urban area consierably counts on ships. Also the dispersion pattern of the all pollutants followed local circulation system in this region. Therefore this study has been developed air quality model which can describe the formation, transport, transformation and deposition processes of air pollutants considering shipping source. Currently, restriction for emission amount of ships does not exist, so our study will be useful to set the omission standard and for devising air quality policy in coastal urban region.

  • PDF

발달 단계의 축대칭 열대저기압의 각운동량에 관한 연구 (Study on the Angular Momentum of Axisymmetric Tropical Cyclone in the Developing Stage)

  • 강현규;정형빈
    • 대기
    • /
    • 제23권1호
    • /
    • pp.1-11
    • /
    • 2013
  • The angular momentum transport of an idealized axisymmetric vortex in the developing stage was investigated using the Weather Research and Forecast (WRF) model. The balanced axisymmetric vortex was constructed based on an empirical function for tangential wind, and the temperature, geopotential, and surface pressure were obtained from the balanced equation. The numerical simulation was carried out for 6 days on the f-plane with the Sea Surface Temperature (SST) set as constant. The weak vortex at initial time was intensified with time, and reached the strength of tropical cyclone in a couple of days. The Absolute Angular Momentum (AAM) was transported along with the secondary circulation of the vortex. Total AAM integrated over a cylinder of radius of 2000 km decreased with simulation time, but total kinetic energy increased rapidly. From the budget analysis, it was found that the surface friction is mainly responsible for the decrease of total AAM. Also, contribution of the surface friction to the AAM loss was about 90% while that of horizontal advection was as small as 8%. The trajectory of neutral numerical tracers following the secondary circulation was presented for the Lagrangian viewpoint of the transports of absolute angular momentum. From the analysis using the trajectory of tracers it was found that the air parcel was under the influence of the surface friction continuously until it leaves the boundary layer near the core. Then the air parcel with reduced amount of angular momentum compared to its original amount was transported from boundary layer to upper level of the vortex and contributed to form the anti-cyclone. These results suggest that the tropical cyclone loses angular momentum as it develops, which is due to the dissipation of angular momentum by the surface friction.

분산식 빗물관리시설 적용에 따른 증발산 변화 연구 (Study on the Changes in Evapotranspiration according to the Decentralized Rainwater Management)

  • 한영해;이태구
    • KIEAE Journal
    • /
    • 제12권5호
    • /
    • pp.3-10
    • /
    • 2012
  • In this study, the influence of decentralized rainwater management over the changes in evapotranspiration was analyzed. The analysis method was obtained by establishing the decentralized rainwater management plan according to different scenarios, and subsequently examined evapotranspiration in the plan. Scenario 1 refers to the analysis of the existing situation, in which was 100% of a parking lot is asphalt pavement. In Scenario 2, the pavement of the parking surface in the parking lot is replaced with lawn blocks. In Scenario 3, some asphalt pavement was removed to establish a flower-bed type infiltration system to allow rainwater to permeate. In Scenario 4, infiltration and storage of rain water would be achieved by transforming the parking surface into lawn blocks, keeping the asphalt for the parking road while establishing a vegetation strip. The amount of evapotranspiration of the target site was analyzed with a water budget analysis program (CAT) using the 2001 meteorological data for each scenario According to the analysis values of S2 and S3, it was found that evapotranspiration is critically affected by the amount of area replaced with pervious area in the total target site. An energy equivalent to 680kWh is required for 1 ton of water to evaporate. Hence, it can be seen that the active inducement of evapotranspiration in urban area makes a positive contribution not only to heat island mitigation, but also to the small-scale water circulation process in a city.

자연형 및 설비형 태양열 온수기의 집열특성에 대한 실험적 연구 (The Experimental Research for the Collecting Characteristics of the Passive and Active type Domestic Solar Hot Water Systems)

  • 이동원;이경호
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.12-18
    • /
    • 2013
  • Domestic solar hot water system can be divided into a passive type and an active type. In a passive type the storage tank is horizontally mounted immediately above the solar collectors. No pumping is required as the hot water naturally rises into the storage tank from the collectors through thermo-siphon flow. While, in an active type the storage tank is ground- or floor-mounted and is below the level of the collectors; a circulating pump moves water or heat transfer fluid between the storage tank and the collectors. We installed two types solar hot water systems consisting of the same storage tank and collectors at the same place, and were measured and compared typical operating characteristics under the same external conditions. In particular, the daily system performance was presented through the stirring test after the sunset. The results show that the amount of solar radiation obtained for an active type were less than a passive type on a cloudy day, because the operation of the circulation pump stops frequently took place on that day. However, on a sunny day, depending on the stable operation of the circulation pump, the amount of solar radiation obtained for an active type were increased than a passive type.

개심술시 Activated Clotting Time 을 이용한 Heparin 및 Protamine 양 조절에 관한 임상적 관찰 (Monitoring of Heparin and Protamine Therapy by Activated Clotting Time During Open-Heart Surgery)

  • 김춘동;이성행
    • Journal of Chest Surgery
    • /
    • 제13권4호
    • /
    • pp.346-355
    • /
    • 1980
  • It has been proposed that wide individual variation in response to heparin be not considered in the conventional set protocol for the control of heparin and protamine during extracorporeal circulation. In this paper, two protocol of heparin and protamine therapy were compared to assess the role of the Activated Clotting Time [ACT] in relation to heparin, protamine, and postoperative blood loss and transfusion. The study groups consisted of the 31 patients [adults 15 and children 16] anticoagulated with the conventional heparin protocol and the 31 patients [adults 15 and children 16] anticoagulated with ACT protocol during extracorporeal circulation. In the conventional heparin protocol, two mg of heparin per kg was administered initially with an additional 0.75 mg of heparin per kg every 30 minutes of extracorporeal circulation, and reversal was accomplished with protamine in a dose of 1.5 times the total milligram of heparin. In the ACT protocol, two mg of heparin per kg was administered initially with an additional dose of heparin enough to reach an ACT of 480 seconds [within safe zone 300 to 600 seconds] from the patient`s dose response curve every 1 hour of extracorporeal circulation, and reversal was done with protamine in a dose of 1.3 times the milligram of the residual heparin. The results were summarized as follows. After a dose of 2 mg per kg of heparin, the patient`s ACT varied from 240 to 600 seconds in adults and from 240 t~ 660 seconds in children. In the ACT group the total amount of heparin administered was markedly reduced when compared to the conventional group, and less protamine was required to neutralize heparin. The dose of heparin administered decreased from 7.07 [SE 0.42] mg/kg of the conventional group to 4.92 [SE 0.32] mg/k8 of the ACT group in adults and from 10.17 [SE 1.15] mg/kg to 5.23 [SE 0.24] mg/kg in children, which represent 30.4% and 48.6% decrease respectively. The dose of protamine administered for reversal decreased from 10.6 [SE 0.63] mg/kg of the conventional group to 3.35 [SE 0.35] mg/kg of the ACT group in adults and from 15.7 [SE 1.70] mg/kg to 3.26 [SE 0.27] mg/kg in children, which represent 68.4% and 79.2% respectively. The ratio of protamine to heparin administered in the conventional group was 1.50:1 in adults and 1.54:1 in children, but in the ACT group 0.68:1 in adults and 0.62:1 in children. Postoperative blood loss and transfusion revealed no statistically significant difference between the two groups. Although six patients in the conventional group and one in the ACT group needed re-exploration for continuous hemorrhage, no case of generalized oozing was encountered, and in each case a definite bleeding site was identified. Author would like emphasizing the value of the ACT protocol in controlling heparin and protamine administration during extracorporeal circulation.

  • PDF

The Generative Mechanism of Cloud Streets

  • Kang Sung-Dae;Kimura Fujio
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • 제1권2호
    • /
    • pp.119-124
    • /
    • 1997
  • Cloud streets were successfully simulated by numerical model (RAMS) including an isolated mountain near the coast, large sensible heat flux from the sea surface, uniform stratification and wind velocity with low Froude number (0.25) in the inflow boundary. The well developed cloud streets between a pair of convective rolls are simulated at a level of 1 km over the sea. The following five results were obtained: 1) For the formation of the pair of convective rolls, both strong static instability and a topographically induced mechanical disturbance are strongly required at the same time. 2) Strong sensible heat flux from the sea surface is the main energy source of the pair of convective rolls, and the buoyancy caused by condensation in the cloud is negligibly small. 3) The pair of convective rolls is a complex of two sub-rolls. One is the outer roll, which has a large radius, but weak circulation, and the other is the inner roll, which has a small radius, but strong circulation. The outer roll gathers a large amount of moisture by convergence in the lower marine boundary, and the inner roll transfers the convergent moisture to the upper boundary layer by strong upward motion between them. 4) The pair of inner rolls form the line-shaped cloud streets, and keep them narrow along the center-line of the domain. 5) Both by non-hydrostatic and by hydrostatic assumptions, cloud streets can be simulated. In our case, non-hydrostatic processes enhanced somewhat the formation of cloud streets. The horizontal size of the topography does not seem to be restricted to within the small scale where non-hydrostatic effects are important.

  • PDF

치료적 방법을 연부조직 손상단계에 따라 사용하기 위한 지침에 관한 연구 (Study on Guidelines for Using Therapeutic Modalities According to Injury Phases of Soft Tissue)

  • 권원안;김식현;전경희
    • The Journal of Korean Physical Therapy
    • /
    • 제12권3호
    • /
    • pp.497-507
    • /
    • 2000
  • This study was performed to understanding on guidelines for using therapeutic modalities according to injury phases of soft tissue. Clinical decisions on how and when therapeutic modalities may be used should be based on recognition of signs and symptoms. as well as some awareness of the time frames associated with the various phases of the Healing process. The physical therapist must have a sound understanding of that process in terms of the sequence of the various process of healing stage. The results of this study are as follows: 1. Once an acute injury has occured, the healing process consists of the imflammatory response phase, the fibroblastic-repair phase, and the maturation-remodeling phase and can impede by various pathologic factors. 2. Modality use in the initial acute injury phase and the inflammatory response phase should be directed toward limiting the amount of swelling and reducing pain. 3. Modality use in the Fibroblastic repair phase may be change from cold to heat. The purpose of heat is to increase circulation to the injured area to promote healing. 4. During the Maturation-Remodeling phase, some type of heating modalities, ultrasound, or short wave and microwave diathermy should be used to increase circulation to the deeper tissue. In this phases, physical therapists must control training and conditioning habits to allow the injury to heal sufficiently.

  • PDF

Upcycling strategies for waste electronic and electrical equipment based on material flow analysis

  • Yi, Sora;Lee, Hisun;Lee, Jeongmin;Kim, Woong
    • Environmental Engineering Research
    • /
    • 제24권1호
    • /
    • pp.74-81
    • /
    • 2019
  • Upcycling generally refers to the conversion of waste materials to something useful or valuable and is a useful concept that can be applied not only to the waste design industry but also to waste recycling and resource circulation. Our study highlights upcycling as the key concept for improving the value of waste by redefining the concept as "the recycling of waste materials and discarded products in ways that enhance their value." Four upcycling strategies are linked to material flow analyses conducted on waste electronic and electrical equipment, specifically waste refrigerators and waste computers, to examine the technologies available for implementation and suggest guidelines for the promotion of upcycling. The amount of waste refrigerators collected by the formal sector was 121,642 tons/y and the informal sector, 63,823 tons/y. The current recycling ratio of waste refrigerators was estimated as 88.53%. A total of 7,585 tons/y of waste computers were collected by the formal sector and 3,807 tons/y by the informal sector after discharge. Meanwhile, the current recycling ratio of waste computers was estimated as 77.43%. We found that it is possible to introduce 28 upcycling technologies in the case of refrigerators, and 15 technologies are available to promote upcycling in the case of computers. By refining the broad concept of upcycling and looking at the stages of material flow, our approach presents universally applicable directions for incorporating upcycling in resource recovery and recirculation plans.

해양 조류발전단지 간섭 연구 (Ocean Current Power Farm Interaction Study)

  • 조철희;임진영;채광수;박노식
    • 한국해양공학회지
    • /
    • 제23권1호
    • /
    • pp.109-113
    • /
    • 2009
  • Several tidal current power plants are being planned and constructed in Korea utilizing the strong tidal currents along the west and south coasts. A tidal current reaches 9.7 m on the west coast; there are few potential regions for tidal current power generation. The construction of a dam to store water can prevent the circulation of water, causing a great environmental impact on the coast and estuary. The tidal barrage could produce a large amount of power, but it should be carefully considered. The purpose of developing renewable energies is to minimize the environmental impact and to maximize the utilization of clean energy. To produce a great quantity of power, tidal current farms require the placement of numerous units in the ocean. The power generation is very dependent on the size of the rotor and the incoming flow velocity. Also, the interactions between devices contribute greatly to the production of power. The efficiency of a power farm is estimated to determine the production rate. This paper introduces 3 D interaction problems between rotating rotors, considering the axial, transverse, and diagonal distances between horizontal axis tidal current devices.